Yuliya V. Druzhinina
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuliya V. Druzhinina has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Iliya V. Soldatov
Moscow Center for Diagnostics and Telemedicine
7 shared publications - Zoya A. Lantukh
Moscow Center for Diagnostics and Telemedicine
7 shared publications - Kirill V. Tolkachev
Research and Practical Clinical Centre of Diagnostics and Telemedicine Technologies of Moscow Healthcare Department
6 shared publications - Sergey A. Ryzhov
Association of Medical Physicists of Russia; Dmitry Rogachev National Medical Research Center of Pediatric Hematology, Oncology and Immunology of the Ministry of Health of the Russian Federation; Research and Practical Clinical Centre of Diagnostics and Telemedicine Technologies of Moscow Healthcare Department
6 shared publications - Alexandr Valerievich Vodovatov
Saint Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing; Saint Petersburg State Pediatric Medical University
5 shared publications - Maria P. Shatenok
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies
5 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) in Вестник НИЯУ МИФИ
- Vol. 15 (5) , 492-499
Калькуляторы эффективных доз при проведении рентгенорадиологических исследований
В рамках анализа качества учета данных о дозах облучения пациентов в медицинских организациях (МО) г. Москвы был выявлен ряд особенностей, требующих незамедлительного решения. Недостаточная автоматизация учета доз ограничивает возможности мониторинга и оптимизации протоколов исследований, создавая угрозу радиационной безопасности (РБ) пациентов. Для устранения выявленных проблем в рамках выполнения научно-исследовательской работы была поставлена задача разработки инструмента, который позволит стандартизировать и автоматизировать процесс расчета эффективных доз облучения пациентов. В настоящей работе разработаны предложения для совершенствования медицинской помощи при учете и контроле доз облучения пациентов при проведении компьютерной томографии (КТ), радионуклидной диагностике (РНД) и радионуклидной диагностики, совмещенной с компьютерной томографией в МО г. Москвы в соответствии с действующими нормативными документами. Внедрение данных инструментов способствует повышению общего уровня РБ пациентов, предоставляя медицинским учреждениям дополнительный надежный механизм для контроля дозовой нагрузки, что является важным шагом на пути к цифровизации процессов радиационного контроля и повышению безопасности пациентов в медицинских учреждениях.
- 2 November 2026
- Published by National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) in Вестник НИЯУ МИФИ
- Vol. 15 (5) , 492-499
Open AccessКалькуляторы эффективных доз при проведении рентгенорадиологических исследований
В рамках анализа качества учета данных о дозах облучения пациентов в медицинских организациях (МО) г. Москвы был выявлен ряд особенностей, требующих незамедлительного решения. Недостаточная автоматизация учета доз ограничивает возможности мониторинга и оптимизации протоколов исследований, создавая угрозу радиационной безопасности (РБ) пациентов. Для устранения выявленных проблем в рамках выполнения научно-исследовательской работы была поставлена задача разработки инструмента, который позволит стандартизировать и автоматизировать процесс расчета эффективных доз облучения пациентов. В настоящей работе разработаны предложения для совершенствования медицинской помощи при учете и контроле доз облучения пациентов при проведении компьютерной томографии (КТ), радионуклидной диагностике (РНД) и радионуклидной диагностики, совмещенной с компьютерной томографией в МО г. Москвы в соответствии с действующими нормативными документами. Внедрение данных инструментов способствует повышению общего уровня РБ пациентов, предоставляя медицинским учреждениям дополнительный надежный механизм для контроля дозовой нагрузки, что является важным шагом на пути к цифровизации процессов радиационного контроля и повышению безопасности пациентов в медицинских учреждениях.
- Open Access
- 4 December 2024
- Published by ECO-Vector LLC (Publications) in Digital Diagnostics
- Vol. 5 (3) , 491-504
Effect of X-ray scan quality on the collective effective dose in patients in telemedicine
BACKGROUND: The key objective of a healthcare provider is to ensure the quality and increase the efficiency of X-ray diagnostics in both municipal and private medical facilities. A poor-quality radiologic image requires repeated procedures, which results in further reputation, time, and economic losses for the medical organization. Moreover, repeated examinations further contribute to the patient’s total radiation exposure. AIM: To assess the contribution of poor-quality X-ray examinations to patient exposure in outpatient medical organizations with telemedicine services. MATERIALS AND METHODS: This study aimed to evaluate poor-quality X-ray examinations recorded by radiologists at the Moscow Reference Center in 2022 by applying a specially developed quality control system for diagnostic examinations based on information technology. In addition, during X-ray examinations, the methods for finding effective doses received by patients were applied in compliance with current regulatory requirements. Statistical methods were also used. RESULTS: In this study, 2,059 poor-quality examinations were recorded, accounting for 0.084% of the total number of examinations interpreted with telemedicine. The collective effective dose from poor-quality examinations was 3.613 man-Sv, which was 0.11% of the total collective dose of patients in outpatient medical organizations. CONCLUSION: The implementation of a quality control system for diagnostic examinations based on information technology proved to be efficient for medical organizations rendering telemedicine services.
- 4 December 2024
- Published by ECO-Vector LLC (Publications) in Digital Diagnostics
- Vol. 5 (3) , 491-504
Open AccessEffect of X-ray scan quality on the collective effective dose in patients in telemedicine
BACKGROUND: The key objective of a healthcare provider is to ensure the quality and increase the efficiency of X-ray diagnostics in both municipal and private medical facilities. A poor-quality radiologic image requires repeated procedures, which results in further reputation, time, and economic losses for the medical organization. Moreover, repeated examinations further contribute to the patient’s total radiation exposure. AIM: To assess the contribution of poor-quality X-ray examinations to patient exposure in outpatient medical organizations with telemedicine services. MATERIALS AND METHODS: This study aimed to evaluate poor-quality X-ray examinations recorded by radiologists at the Moscow Reference Center in 2022 by applying a specially developed quality control system for diagnostic examinations based on information technology. In addition, during X-ray examinations, the methods for finding effective doses received by patients were applied in compliance with current regulatory requirements. Statistical methods were also used. RESULTS: In this study, 2,059 poor-quality examinations were recorded, accounting for 0.084% of the total number of examinations interpreted with telemedicine. The collective effective dose from poor-quality examinations was 3.613 man-Sv, which was 0.11% of the total collective dose of patients in outpatient medical organizations. CONCLUSION: The implementation of a quality control system for diagnostic examinations based on information technology proved to be efficient for medical organizations rendering telemedicine services.
- Open Access
- 7 October 2024
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 17 (3) , 103-113
Diagnostic reference levels for the city of Moscow during X-ray examinations
Diagnostic reference levels are one of the effective tools for optimizing patient radiation doses in diagnostic radiology. The staff of domestic radiology departments does not have an understanding of the development process and use of diagnostic reference levels during X-ray examinations, although this tool is a generally accepted in practice abroad. The article shows the experience of forming regional diagnostic reference levels based on measurements provided by the accredited testing laboratory of the Scientific and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Healthcare Department. The diagnostic reference levels for radiography in Moscow were developed for eight of the most common types of examinations based on the operation of 216 digital X-ray machines. The resulting levels, expressed in the dose-area product (cGy-cm2) and effective dose (mSv), were compared with the local diagnostic reference levels for the Ryazan region, Russia, and national diagnostic reference levels for other countries. The analysis showed continuity in the values. Some types of studies have been optimized. The developed diagnostic reference levels are the quality performance indicators foe diagnostic radiology departments and will be used to optimize a patient radiation dose during diagnostic studies in Moscow.
- 7 October 2024
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 17 (3) , 103-113
Open AccessDiagnostic reference levels for the city of Moscow during X-ray examinations
Diagnostic reference levels are one of the effective tools for optimizing patient radiation doses in diagnostic radiology. The staff of domestic radiology departments does not have an understanding of the development process and use of diagnostic reference levels during X-ray examinations, although this tool is a generally accepted in practice abroad. The article shows the experience of forming regional diagnostic reference levels based on measurements provided by the accredited testing laboratory of the Scientific and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Healthcare Department. The diagnostic reference levels for radiography in Moscow were developed for eight of the most common types of examinations based on the operation of 216 digital X-ray machines. The resulting levels, expressed in the dose-area product (cGy-cm2) and effective dose (mSv), were compared with the local diagnostic reference levels for the Ryazan region, Russia, and national diagnostic reference levels for other countries. The analysis showed continuity in the values. Some types of studies have been optimized. The developed diagnostic reference levels are the quality performance indicators foe diagnostic radiology departments and will be used to optimize a patient radiation dose during diagnostic studies in Moscow.
- Open Access
- 2 October 2023
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (3) , 67-80
Russian decision support systems in radiation diagnostics as an element of ensuring the radiation safety of patients
There is a well-established opinion that the radiation safety of the patient and staff lies within the scope of the activities and responsibilities of the radiation diagnostics departments. However, repeated referrals and unjustified X-ray examinations from clinicians can make a significant contribution to the radiation load of the patient and the workload of the staff. The radiation safety requirements formulated in the article are designed for an effective monitoring tool for unjustified studies – the Clinical Decision Support System. The modern park of domestic software in this area was also analyzed. It was found, that the existing domestic Clinical Decision Support Systems do not fully meet the formulated current radiation safety requirements. The majority of clinical decision support system do not offer a choice of the most sparing methods of X-ray examinations (only 31% offer), and do not contain information about the accumulated patient dose for making a decision on the appointment of studies (only 23% contain). The developed methodology for assessing the Clinical Decision Support Systems will allow choosing and implementing the most optimal system in terms of radiation safety into clinical practice.
- 2 October 2023
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (3) , 67-80
Open AccessRussian decision support systems in radiation diagnostics as an element of ensuring the radiation safety of patients
There is a well-established opinion that the radiation safety of the patient and staff lies within the scope of the activities and responsibilities of the radiation diagnostics departments. However, repeated referrals and unjustified X-ray examinations from clinicians can make a significant contribution to the radiation load of the patient and the workload of the staff. The radiation safety requirements formulated in the article are designed for an effective monitoring tool for unjustified studies – the Clinical Decision Support System. The modern park of domestic software in this area was also analyzed. It was found, that the existing domestic Clinical Decision Support Systems do not fully meet the formulated current radiation safety requirements. The majority of clinical decision support system do not offer a choice of the most sparing methods of X-ray examinations (only 31% offer), and do not contain information about the accumulated patient dose for making a decision on the appointment of studies (only 23% contain). The developed methodology for assessing the Clinical Decision Support Systems will allow choosing and implementing the most optimal system in terms of radiation safety into clinical practice.
- Open Access
- 12 July 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (2) , 142-155
Problems of personnel irradiation in modern medical technologies
BACKGROUND: The widespread use of radiation sources in medical practice (cardio-endovascular surgery, endoscopy, traumatology, urology, neurosurgery, dentistry, and radioisotope diagnostics departments) leads to irradiation of the lens of the eye and the skin of the hands. The introduction of new recommendations by the IAEA to reduce the limit of the annual equivalent dose to the lens (20 mSv) has led to an inaccurate dose assessment based on the effective dose. AIM: To analyze approaches and assess equivalent doses of irradiation of the lens of the eye and skin of the hands of medical personnel during various diagnostic studies under the influence of X-rays and radiopharmaceuticals studies and to compare the results obtained with previously published data. MATERIALS AND METHODS: Thermo-luminescent dosimetry was used. Dose assessment was performed by cardio-endovascular surgery, endoscopy, isotope diagnostics, dentistry, and urology personnel. RESULTS: The estimated annual equivalent doses to the lens of the eye for doctors of cardio-endovascular surgery departments, in most cases, ranging 3590 mSv, 619 mSv for the average medical staff (in some cases, the doctor [225 mSv] and the nurse [180 mSv]) and 4.59 mSv for the staff of the department of radioisotope diagnostics. The annual calculated equivalent doses to the skin of the hands for cardio-endovascular surgery personnel were 17100 and 24220 mSv for the staff working with radiopharmaceuticals. It is shown that the use of an estimate of the average dose per operation by cardio-endovascular surgery doctors, as a rule, inevitably leads to an excess of the equivalent dose to the lens of the eye after a certain number of operations. CONCLUSION: When a certain number of operations are exceeded (100200), equivalent doses to the eyes lens in cardio-endovascular surgery doctors above 20 mSv per year can be formed. At current radiation levels, a lesion of the eyes lens was found in a cardio-endovascular surgery doctor. The results indicate the need for further dosimetric measurements and epidemiological studies, based on which recommendations for radiation protection of the eyes lens and the skin of the hands of medical personnel working in low-intensity, scattered, gamma X-ray radiation can be developed.
- 12 July 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (2) , 142-155
Open AccessProblems of personnel irradiation in modern medical technologies
BACKGROUND: The widespread use of radiation sources in medical practice (cardio-endovascular surgery, endoscopy, traumatology, urology, neurosurgery, dentistry, and radioisotope diagnostics departments) leads to irradiation of the lens of the eye and the skin of the hands. The introduction of new recommendations by the IAEA to reduce the limit of the annual equivalent dose to the lens (20 mSv) has led to an inaccurate dose assessment based on the effective dose. AIM: To analyze approaches and assess equivalent doses of irradiation of the lens of the eye and skin of the hands of medical personnel during various diagnostic studies under the influence of X-rays and radiopharmaceuticals studies and to compare the results obtained with previously published data. MATERIALS AND METHODS: Thermo-luminescent dosimetry was used. Dose assessment was performed by cardio-endovascular surgery, endoscopy, isotope diagnostics, dentistry, and urology personnel. RESULTS: The estimated annual equivalent doses to the lens of the eye for doctors of cardio-endovascular surgery departments, in most cases, ranging 3590 mSv, 619 mSv for the average medical staff (in some cases, the doctor [225 mSv] and the nurse [180 mSv]) and 4.59 mSv for the staff of the department of radioisotope diagnostics. The annual calculated equivalent doses to the skin of the hands for cardio-endovascular surgery personnel were 17100 and 24220 mSv for the staff working with radiopharmaceuticals. It is shown that the use of an estimate of the average dose per operation by cardio-endovascular surgery doctors, as a rule, inevitably leads to an excess of the equivalent dose to the lens of the eye after a certain number of operations. CONCLUSION: When a certain number of operations are exceeded (100200), equivalent doses to the eyes lens in cardio-endovascular surgery doctors above 20 mSv per year can be formed. At current radiation levels, a lesion of the eyes lens was found in a cardio-endovascular surgery doctor. The results indicate the need for further dosimetric measurements and epidemiological studies, based on which recommendations for radiation protection of the eyes lens and the skin of the hands of medical personnel working in low-intensity, scattered, gamma X-ray radiation can be developed.
- Open Access
- 4 April 2023
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (1) , 66-79
Unjustified referrals to radiological examinations and their impact on the collective effective dose of patients in outpatient medical organizations
In recent years, an increase in the collective dose from medical exposure has been recorded annually, which is associated with an increase in the availability of high-tech methods of medical care and an increase of their percentage in the structure of X-ray studies. However, any exposure to ionizing radiation on a patient is associated with an increased risk of stochastic effects. The justification principle is the most effective to ensure the radiation safety of patients. The article considers in detail the experiment on the application of the justification principle in medical organizations. The aim of the study was to evaluate the incidence of unjustified referrals to radiological examinations and their impact on the collective effective dose of patients in outpatient medical organizations. As a result, it was ound, that the collective dose from studies with unjustified referrals contributes 21% to the annual collective dose from X-ray studies in outpatient medical organizations. The result obtained confirms the need to ensure the availability of information on clinical recommendations, the accumulated effective dose and patient characteristics in medical information systems, and proves the importance of using this information when prescribing X-ray radiological studies.
- 4 April 2023
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (1) , 66-79
Open AccessUnjustified referrals to radiological examinations and their impact on the collective effective dose of patients in outpatient medical organizations
In recent years, an increase in the collective dose from medical exposure has been recorded annually, which is associated with an increase in the availability of high-tech methods of medical care and an increase of their percentage in the structure of X-ray studies. However, any exposure to ionizing radiation on a patient is associated with an increased risk of stochastic effects. The justification principle is the most effective to ensure the radiation safety of patients. The article considers in detail the experiment on the application of the justification principle in medical organizations. The aim of the study was to evaluate the incidence of unjustified referrals to radiological examinations and their impact on the collective effective dose of patients in outpatient medical organizations. As a result, it was ound, that the collective dose from studies with unjustified referrals contributes 21% to the annual collective dose from X-ray studies in outpatient medical organizations. The result obtained confirms the need to ensure the availability of information on clinical recommendations, the accumulated effective dose and patient characteristics in medical information systems, and proves the importance of using this information when prescribing X-ray radiological studies.
- Open Access
- 17 October 2022
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 3 (3) , 212-230
Patient dose monitoring software in radiology
An increase in the number of diagnostic procedures using ionizing radiation (computed tomography, interventional procedures, and the use of nuclear medicine) results in an increase in radiation exposure and, consequently, an increase in collective and individual doses of radiation to patients. Diagnostic studies from the international professional community are extensively focusing on issues such as management and dose optimization. Worldwide practice can resolve these issues using software for monitoring patient doses to automatically collect, analyze, and account for patient doses in various types of diagnostic studies. The software allows to obtain data on the doses of patients from X-ray procedures and detailed information about studies, track the total accumulated dose of the patient, and maintain statistics on the device, X-ray laboratory, and the medical organization. It also helps analyze the collected dosimetric data, deduce the causal relationship between dose indications and diagnostic procedure conditions, and monitor the effectiveness of the equipment. The basic capabilities of patient dose monitoring software (DMS) available on the global market were investigated. The major technical requirements for the software functional needed in practical work were defined. Modern DMS have a wide range of possibilities for automated collection, storage, and management of patient radiation exposure data in radiology departments. DMS increase the quality of healthcare services, provide patient safety, and optimize the workflow of medical organizations.
- 17 October 2022
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 3 (3) , 212-230
Open AccessPatient dose monitoring software in radiology
An increase in the number of diagnostic procedures using ionizing radiation (computed tomography, interventional procedures, and the use of nuclear medicine) results in an increase in radiation exposure and, consequently, an increase in collective and individual doses of radiation to patients. Diagnostic studies from the international professional community are extensively focusing on issues such as management and dose optimization. Worldwide practice can resolve these issues using software for monitoring patient doses to automatically collect, analyze, and account for patient doses in various types of diagnostic studies. The software allows to obtain data on the doses of patients from X-ray procedures and detailed information about studies, track the total accumulated dose of the patient, and maintain statistics on the device, X-ray laboratory, and the medical organization. It also helps analyze the collected dosimetric data, deduce the causal relationship between dose indications and diagnostic procedure conditions, and monitor the effectiveness of the equipment. The basic capabilities of patient dose monitoring software (DMS) available on the global market were investigated. The major technical requirements for the software functional needed in practical work were defined. Modern DMS have a wide range of possibilities for automated collection, storage, and management of patient radiation exposure data in radiology departments. DMS increase the quality of healthcare services, provide patient safety, and optimize the workflow of medical organizations.
- Open Access
- 24 April 2022
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 3 (1) , 5-15
Coronavirus disease-2019: Changes in computed tomography radiation burden across Moscow medical facilities
BACKGROUND: The spread of coronavirus disease-2019 (COVID-19) in Moscow has significantly increased the number of chest computed tomography examinations to establish a diagnosis and assess the treatment efficacy. In Moscow, the new approach to diagnostic imaging associated with COVID-19 caused divergent shifts in the volume and structure of the population radiation burden. This study aimed to bridge the gap in data, as no reliable information about the changes in the structure of diagnostic imaging and the current radiation burden due to COVID-19 in the Moscow population has been reported. AIMS: To evaluate the impact of the pandemic on the computed tomography radiation doses in Moscow medical facilities between 2017 and 2020. MATERIALS AND METHODS: We collected and analyzed the following data: forms No. 3-DOZ completed by the public and private Moscow medical facilities in 20172020; forms No. 30 completed in 20172020; data from the Unified Radiological Information Service for 2020. The study provides details about the annual population radiation exposure and the average individual radiation doses, with a breakdown by anatomic region. RESULTS: The statistical form evaluation elucidated the boost of computed tomography imaging in Moscow, accounting for 31% higher than anticipated. In 2020, the number of chest imaging studies increased almost two-fold compared to the previous periods. Thereby, causing a corresponding increase in the mean effective dose by over two times. CONCLUSION: The results show that the epidemiological situation of 2020 had a profound effect on the changes in the computed tomography-related radiation exposure, which helped us get insight into the diagnostic effect of certain types of computed tomography studies applied to various anatomic regions. The analysis contributed to a better understanding of the strengths and weaknesses of various statistical forms.
- 24 April 2022
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 3 (1) , 5-15
Open AccessCoronavirus disease-2019: Changes in computed tomography radiation burden across Moscow medical facilities
BACKGROUND: The spread of coronavirus disease-2019 (COVID-19) in Moscow has significantly increased the number of chest computed tomography examinations to establish a diagnosis and assess the treatment efficacy. In Moscow, the new approach to diagnostic imaging associated with COVID-19 caused divergent shifts in the volume and structure of the population radiation burden. This study aimed to bridge the gap in data, as no reliable information about the changes in the structure of diagnostic imaging and the current radiation burden due to COVID-19 in the Moscow population has been reported. AIMS: To evaluate the impact of the pandemic on the computed tomography radiation doses in Moscow medical facilities between 2017 and 2020. MATERIALS AND METHODS: We collected and analyzed the following data: forms No. 3-DOZ completed by the public and private Moscow medical facilities in 20172020; forms No. 30 completed in 20172020; data from the Unified Radiological Information Service for 2020. The study provides details about the annual population radiation exposure and the average individual radiation doses, with a breakdown by anatomic region. RESULTS: The statistical form evaluation elucidated the boost of computed tomography imaging in Moscow, accounting for 31% higher than anticipated. In 2020, the number of chest imaging studies increased almost two-fold compared to the previous periods. Thereby, causing a corresponding increase in the mean effective dose by over two times. CONCLUSION: The results show that the epidemiological situation of 2020 had a profound effect on the changes in the computed tomography-related radiation exposure, which helped us get insight into the diagnostic effect of certain types of computed tomography studies applied to various anatomic regions. The analysis contributed to a better understanding of the strengths and weaknesses of various statistical forms.
- 10 March 2022
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 101 (2) , 124-131
Comparative analysis of effective doses to patients undergoing examination on general-purpose X-ray machines, calculated by various methods
Purpose. Comparative evaluation of effective doses to patients calculated using various methods for the most common X-ray examinations performed on general-purpose digital X-ray machines. Materials and methods. Data collection on parameters of examinations was performed for seven digital X-ray machines located in several Moscow medical facilities. Parameters for the most common X-ray examinations were collected for 120 standard patients from October to December 2019. Results. For all X-ray machines, significant reliable discrepancies were revealed between effective doses from the protocols of accredited laboratories (calculated based on radiation output) and effective doses determined by the authors based on the collected values of the dose-area product. The differences, on average, did not exceed ± 100%. However, the discrepancies for the thoracic spine and chest X-ray on some devices were even more significant. Limitations. Lack of a unified, standardised methodology for collecting parameters of radiological studies. Conclusion. The parameters of standard X-ray studies, collected by accredited laboratories and presented in the current methodological guidelines for monitoring patients’ effective doses, significantly differ from the studies’ parameters obtained from our data collection results. The existing methods for calculating effective doses require to be updated and revised. It makes sense to give up using transition coefficients and specialised software that calculates the effective dose, taking into account the geometry of patients’ exposure and physical and technical parameters of the study.
- 10 March 2022
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Hygiene and sanitation
- Vol. 101 (2) , 124-131
Comparative analysis of effective doses to patients undergoing examination on general-purpose X-ray machines, calculated by various methods
Purpose. Comparative evaluation of effective doses to patients calculated using various methods for the most common X-ray examinations performed on general-purpose digital X-ray machines. Materials and methods. Data collection on parameters of examinations was performed for seven digital X-ray machines located in several Moscow medical facilities. Parameters for the most common X-ray examinations were collected for 120 standard patients from October to December 2019. Results. For all X-ray machines, significant reliable discrepancies were revealed between effective doses from the protocols of accredited laboratories (calculated based on radiation output) and effective doses determined by the authors based on the collected values of the dose-area product. The differences, on average, did not exceed ± 100%. However, the discrepancies for the thoracic spine and chest X-ray on some devices were even more significant. Limitations. Lack of a unified, standardised methodology for collecting parameters of radiological studies. Conclusion. The parameters of standard X-ray studies, collected by accredited laboratories and presented in the current methodological guidelines for monitoring patients’ effective doses, significantly differ from the studies’ parameters obtained from our data collection results. The existing methods for calculating effective doses require to be updated and revised. It makes sense to give up using transition coefficients and specialised software that calculates the effective dose, taking into account the geometry of patients’ exposure and physical and technical parameters of the study.