Kirill V. Tolkachev
Research Subjects
Kirill V. Tolkachev has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Iliya V. Soldatov
Moscow Center for Diagnostics and Telemedicine
7 shared publications - Yuliya V. Druzhinina
Moscow Center for Diagnostics and Telemedicine
6 shared publications - Alexandr Valerievich Vodovatov
Saint Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing; Saint Petersburg State Pediatric Medical University
5 shared publications - Maria P. Shatenok
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies
5 shared publications - Sergey A. Ryzhov
Association of Medical Physicists of Russia; Dmitry Rogachev National Medical Research Center of Pediatric Hematology, Oncology and Immunology of the Ministry of Health of the Russian Federation; Research and Practical Clinical Centre of Diagnostics and Telemedicine Technologies of Moscow Healthcare Department
5 shared publications - Zoya A. Lantukh
Moscow Center for Diagnostics and Telemedicine
5 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) in Вестник НИЯУ МИФИ
- Vol. 15 (5) , 492-499
Калькуляторы эффективных доз при проведении рентгенорадиологических исследований
В рамках анализа качества учета данных о дозах облучения пациентов в медицинских организациях (МО) г. Москвы был выявлен ряд особенностей, требующих незамедлительного решения. Недостаточная автоматизация учета доз ограничивает возможности мониторинга и оптимизации протоколов исследований, создавая угрозу радиационной безопасности (РБ) пациентов. Для устранения выявленных проблем в рамках выполнения научно-исследовательской работы была поставлена задача разработки инструмента, который позволит стандартизировать и автоматизировать процесс расчета эффективных доз облучения пациентов. В настоящей работе разработаны предложения для совершенствования медицинской помощи при учете и контроле доз облучения пациентов при проведении компьютерной томографии (КТ), радионуклидной диагностике (РНД) и радионуклидной диагностики, совмещенной с компьютерной томографией в МО г. Москвы в соответствии с действующими нормативными документами. Внедрение данных инструментов способствует повышению общего уровня РБ пациентов, предоставляя медицинским учреждениям дополнительный надежный механизм для контроля дозовой нагрузки, что является важным шагом на пути к цифровизации процессов радиационного контроля и повышению безопасности пациентов в медицинских учреждениях.
- 2 November 2026
- Published by National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) in Вестник НИЯУ МИФИ
- Vol. 15 (5) , 492-499
Open AccessКалькуляторы эффективных доз при проведении рентгенорадиологических исследований
В рамках анализа качества учета данных о дозах облучения пациентов в медицинских организациях (МО) г. Москвы был выявлен ряд особенностей, требующих незамедлительного решения. Недостаточная автоматизация учета доз ограничивает возможности мониторинга и оптимизации протоколов исследований, создавая угрозу радиационной безопасности (РБ) пациентов. Для устранения выявленных проблем в рамках выполнения научно-исследовательской работы была поставлена задача разработки инструмента, который позволит стандартизировать и автоматизировать процесс расчета эффективных доз облучения пациентов. В настоящей работе разработаны предложения для совершенствования медицинской помощи при учете и контроле доз облучения пациентов при проведении компьютерной томографии (КТ), радионуклидной диагностике (РНД) и радионуклидной диагностики, совмещенной с компьютерной томографией в МО г. Москвы в соответствии с действующими нормативными документами. Внедрение данных инструментов способствует повышению общего уровня РБ пациентов, предоставляя медицинским учреждениям дополнительный надежный механизм для контроля дозовой нагрузки, что является важным шагом на пути к цифровизации процессов радиационного контроля и повышению безопасности пациентов в медицинских учреждениях.
- Open Access
- 13 January 2025
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 17 (4) , 126-134
Determination of the conversion coefficients from the dose-length product to the effective dose for CT-examinations of the whole body including lower extremitie
Today in the Russian Federation, the existing method for assessing patients` effective doses during computed tomography in the form of conversion coefficients from the dose-length product provides for the area from the head to the upper third of the femur but does not consider the possibility of scanning the whole body including the lower extremities. In this case, for some nosologies, the lower extremities may be involved. The aim of the study was to develop conversion coefficients from the dose-length product to the effective dose for whole-body computed tomography scanning including the patient's lower extremities. The coefficients for whole-body computed tomography scans (including the lower extremities) were determined for a sample of computed tomography scanners that are part of positron emission tomography combined with computed tomography devices of different models for adults and children of different age groups. In NCICT 3.0 software absorbed organ doses were calculated taking into account the specific model of devices and scan length. Effective doses were determined in accordance with the methodology presented in Publication 60 of the International Commission on Radiological Protection and Radiation Safety Standards 99/2009. Separately, conversion coefficients were developed from the dose-length product to the absorbed dose in uterus to enable predictive assessment of doses in the fetus in pregnant women. The study presents the average values of the received effective doses, absorbed doses in uterus and conversion coefficients for all considered models of devices. Conversion coefficients for protocols with automatic tube current modulation were lower compared to those for protocols without automatic tube current modulation, especially for pediatric patients: for children with an average age of 0 years – 9 times, for children an average age of 1 year – 6 times, for children an average age of 5 years – 5 times, for children an average age of 10 years – 3 times, for children an average age of 15 years – 2 times; for adults the difference was 20%. Comparison of the conversion coefficients from the dose-length product to the effective dose for computed tomographic scanning of the whole body area limited to the upper third of the femur, presented in guidelines 2.6.1.3584-19, with the values obtained in this study for the whole body area with the lower extremities without automatic tube current modulation showed that for all age groups, with the exception of newborns, the conversion coefficients for the scanning area with the lower extremities are lower than those presented in the guidelines. Using the conversion coefficients from the Guideline 2.6.1.3584-19 for whole-body computed tomography scanning with the lower extremities will lead to a significant overestimation of patient doses. The calculated conversion coefficients from the dose-length product to the absorbed dose in uterus and from the dose-length product to the effective dose for computed tomography examination of the whole body with the lower extremities for different age groups of patients are suitable for assessing the effective doses of patients and for prognostic estimates of absorbed dose in the fetus in pregnant women.
- 13 January 2025
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 17 (4) , 126-134
Open AccessDetermination of the conversion coefficients from the dose-length product to the effective dose for CT-examinations of the whole body including lower extremitie
Today in the Russian Federation, the existing method for assessing patients` effective doses during computed tomography in the form of conversion coefficients from the dose-length product provides for the area from the head to the upper third of the femur but does not consider the possibility of scanning the whole body including the lower extremities. In this case, for some nosologies, the lower extremities may be involved. The aim of the study was to develop conversion coefficients from the dose-length product to the effective dose for whole-body computed tomography scanning including the patient's lower extremities. The coefficients for whole-body computed tomography scans (including the lower extremities) were determined for a sample of computed tomography scanners that are part of positron emission tomography combined with computed tomography devices of different models for adults and children of different age groups. In NCICT 3.0 software absorbed organ doses were calculated taking into account the specific model of devices and scan length. Effective doses were determined in accordance with the methodology presented in Publication 60 of the International Commission on Radiological Protection and Radiation Safety Standards 99/2009. Separately, conversion coefficients were developed from the dose-length product to the absorbed dose in uterus to enable predictive assessment of doses in the fetus in pregnant women. The study presents the average values of the received effective doses, absorbed doses in uterus and conversion coefficients for all considered models of devices. Conversion coefficients for protocols with automatic tube current modulation were lower compared to those for protocols without automatic tube current modulation, especially for pediatric patients: for children with an average age of 0 years – 9 times, for children an average age of 1 year – 6 times, for children an average age of 5 years – 5 times, for children an average age of 10 years – 3 times, for children an average age of 15 years – 2 times; for adults the difference was 20%. Comparison of the conversion coefficients from the dose-length product to the effective dose for computed tomographic scanning of the whole body area limited to the upper third of the femur, presented in guidelines 2.6.1.3584-19, with the values obtained in this study for the whole body area with the lower extremities without automatic tube current modulation showed that for all age groups, with the exception of newborns, the conversion coefficients for the scanning area with the lower extremities are lower than those presented in the guidelines. Using the conversion coefficients from the Guideline 2.6.1.3584-19 for whole-body computed tomography scanning with the lower extremities will lead to a significant overestimation of patient doses. The calculated conversion coefficients from the dose-length product to the absorbed dose in uterus and from the dose-length product to the effective dose for computed tomography examination of the whole body with the lower extremities for different age groups of patients are suitable for assessing the effective doses of patients and for prognostic estimates of absorbed dose in the fetus in pregnant women.
- Open Access
- 4 December 2024
- Published by ECO-Vector LLC (Publications) in Digital Diagnostics
- Vol. 5 (3) , 491-504
Effect of X-ray scan quality on the collective effective dose in patients in telemedicine
BACKGROUND: The key objective of a healthcare provider is to ensure the quality and increase the efficiency of X-ray diagnostics in both municipal and private medical facilities. A poor-quality radiologic image requires repeated procedures, which results in further reputation, time, and economic losses for the medical organization. Moreover, repeated examinations further contribute to the patient’s total radiation exposure. AIM: To assess the contribution of poor-quality X-ray examinations to patient exposure in outpatient medical organizations with telemedicine services. MATERIALS AND METHODS: This study aimed to evaluate poor-quality X-ray examinations recorded by radiologists at the Moscow Reference Center in 2022 by applying a specially developed quality control system for diagnostic examinations based on information technology. In addition, during X-ray examinations, the methods for finding effective doses received by patients were applied in compliance with current regulatory requirements. Statistical methods were also used. RESULTS: In this study, 2,059 poor-quality examinations were recorded, accounting for 0.084% of the total number of examinations interpreted with telemedicine. The collective effective dose from poor-quality examinations was 3.613 man-Sv, which was 0.11% of the total collective dose of patients in outpatient medical organizations. CONCLUSION: The implementation of a quality control system for diagnostic examinations based on information technology proved to be efficient for medical organizations rendering telemedicine services.
- 4 December 2024
- Published by ECO-Vector LLC (Publications) in Digital Diagnostics
- Vol. 5 (3) , 491-504
Open AccessEffect of X-ray scan quality on the collective effective dose in patients in telemedicine
BACKGROUND: The key objective of a healthcare provider is to ensure the quality and increase the efficiency of X-ray diagnostics in both municipal and private medical facilities. A poor-quality radiologic image requires repeated procedures, which results in further reputation, time, and economic losses for the medical organization. Moreover, repeated examinations further contribute to the patient’s total radiation exposure. AIM: To assess the contribution of poor-quality X-ray examinations to patient exposure in outpatient medical organizations with telemedicine services. MATERIALS AND METHODS: This study aimed to evaluate poor-quality X-ray examinations recorded by radiologists at the Moscow Reference Center in 2022 by applying a specially developed quality control system for diagnostic examinations based on information technology. In addition, during X-ray examinations, the methods for finding effective doses received by patients were applied in compliance with current regulatory requirements. Statistical methods were also used. RESULTS: In this study, 2,059 poor-quality examinations were recorded, accounting for 0.084% of the total number of examinations interpreted with telemedicine. The collective effective dose from poor-quality examinations was 3.613 man-Sv, which was 0.11% of the total collective dose of patients in outpatient medical organizations. CONCLUSION: The implementation of a quality control system for diagnostic examinations based on information technology proved to be efficient for medical organizations rendering telemedicine services.
- Open Access
- 7 October 2024
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 17 (3) , 103-113
Diagnostic reference levels for the city of Moscow during X-ray examinations
Diagnostic reference levels are one of the effective tools for optimizing patient radiation doses in diagnostic radiology. The staff of domestic radiology departments does not have an understanding of the development process and use of diagnostic reference levels during X-ray examinations, although this tool is a generally accepted in practice abroad. The article shows the experience of forming regional diagnostic reference levels based on measurements provided by the accredited testing laboratory of the Scientific and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Healthcare Department. The diagnostic reference levels for radiography in Moscow were developed for eight of the most common types of examinations based on the operation of 216 digital X-ray machines. The resulting levels, expressed in the dose-area product (cGy-cm2) and effective dose (mSv), were compared with the local diagnostic reference levels for the Ryazan region, Russia, and national diagnostic reference levels for other countries. The analysis showed continuity in the values. Some types of studies have been optimized. The developed diagnostic reference levels are the quality performance indicators foe diagnostic radiology departments and will be used to optimize a patient radiation dose during diagnostic studies in Moscow.
- 7 October 2024
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 17 (3) , 103-113
Open AccessDiagnostic reference levels for the city of Moscow during X-ray examinations
Diagnostic reference levels are one of the effective tools for optimizing patient radiation doses in diagnostic radiology. The staff of domestic radiology departments does not have an understanding of the development process and use of diagnostic reference levels during X-ray examinations, although this tool is a generally accepted in practice abroad. The article shows the experience of forming regional diagnostic reference levels based on measurements provided by the accredited testing laboratory of the Scientific and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Healthcare Department. The diagnostic reference levels for radiography in Moscow were developed for eight of the most common types of examinations based on the operation of 216 digital X-ray machines. The resulting levels, expressed in the dose-area product (cGy-cm2) and effective dose (mSv), were compared with the local diagnostic reference levels for the Ryazan region, Russia, and national diagnostic reference levels for other countries. The analysis showed continuity in the values. Some types of studies have been optimized. The developed diagnostic reference levels are the quality performance indicators foe diagnostic radiology departments and will be used to optimize a patient radiation dose during diagnostic studies in Moscow.
- Open Access
- 7 July 2024
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 17 (2) , 64-75
Improving the approach to calculating shielding in computed tomography rooms
The study assessed the acceptability of the currently existing approach to calculating shielding in computed tomography rooms and formulated proposals for its improvement, taking into account the parameters of research in domestic medical practice. It is proposed to use the dose-length product as the main measured parameter in the new approach to calculating shielding. Typical tomograph workload values of dose-length product, typical for examinations in the Russian Federation, were assessed. Using thermoluminescent detectors, the experimental assessment of the distribution of absorbed dose in the air in a computed tomography room was carried out. The experimental results showed that the distribution of of X-ray exposure in the central plane is not isotropic. Due to the attenuation of exposure by the gantry design, “shadow” zones are observed, where the absorbed dose reduction in the air reaches 10-13 times compared to its level in the direction of couch movement. Based on the results of measurements of the distribution of absorbed dose in air, the relative scatter coefficients were calculated. The workload was determined for 7 tomographs (1 in St. Petersburg and 6 in Moscow). For each tomograph, the average weekly number of head and body examinations and the values of dose-length product for these areas were assessed, taking into account the number of multiphase examinations. The obtained workload values turned out to be one or two orders of magnitude higher than those currently used in calculating shielding. Based on the results of the study and literature data, the work proposes a new approach to calculating shielding in computed tomography rooms, based on the value of measured dose-length product during the examination and allowing to take into account the specifics of the operation of the device.
- 7 July 2024
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 17 (2) , 64-75
Open AccessImproving the approach to calculating shielding in computed tomography rooms
The study assessed the acceptability of the currently existing approach to calculating shielding in computed tomography rooms and formulated proposals for its improvement, taking into account the parameters of research in domestic medical practice. It is proposed to use the dose-length product as the main measured parameter in the new approach to calculating shielding. Typical tomograph workload values of dose-length product, typical for examinations in the Russian Federation, were assessed. Using thermoluminescent detectors, the experimental assessment of the distribution of absorbed dose in the air in a computed tomography room was carried out. The experimental results showed that the distribution of of X-ray exposure in the central plane is not isotropic. Due to the attenuation of exposure by the gantry design, “shadow” zones are observed, where the absorbed dose reduction in the air reaches 10-13 times compared to its level in the direction of couch movement. Based on the results of measurements of the distribution of absorbed dose in air, the relative scatter coefficients were calculated. The workload was determined for 7 tomographs (1 in St. Petersburg and 6 in Moscow). For each tomograph, the average weekly number of head and body examinations and the values of dose-length product for these areas were assessed, taking into account the number of multiphase examinations. The obtained workload values turned out to be one or two orders of magnitude higher than those currently used in calculating shielding. Based on the results of the study and literature data, the work proposes a new approach to calculating shielding in computed tomography rooms, based on the value of measured dose-length product during the examination and allowing to take into account the specifics of the operation of the device.
- Open Access
- 2 October 2023
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (3) , 67-80
Russian decision support systems in radiation diagnostics as an element of ensuring the radiation safety of patients
There is a well-established opinion that the radiation safety of the patient and staff lies within the scope of the activities and responsibilities of the radiation diagnostics departments. However, repeated referrals and unjustified X-ray examinations from clinicians can make a significant contribution to the radiation load of the patient and the workload of the staff. The radiation safety requirements formulated in the article are designed for an effective monitoring tool for unjustified studies – the Clinical Decision Support System. The modern park of domestic software in this area was also analyzed. It was found, that the existing domestic Clinical Decision Support Systems do not fully meet the formulated current radiation safety requirements. The majority of clinical decision support system do not offer a choice of the most sparing methods of X-ray examinations (only 31% offer), and do not contain information about the accumulated patient dose for making a decision on the appointment of studies (only 23% contain). The developed methodology for assessing the Clinical Decision Support Systems will allow choosing and implementing the most optimal system in terms of radiation safety into clinical practice.
- 2 October 2023
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (3) , 67-80
Open AccessRussian decision support systems in radiation diagnostics as an element of ensuring the radiation safety of patients
There is a well-established opinion that the radiation safety of the patient and staff lies within the scope of the activities and responsibilities of the radiation diagnostics departments. However, repeated referrals and unjustified X-ray examinations from clinicians can make a significant contribution to the radiation load of the patient and the workload of the staff. The radiation safety requirements formulated in the article are designed for an effective monitoring tool for unjustified studies – the Clinical Decision Support System. The modern park of domestic software in this area was also analyzed. It was found, that the existing domestic Clinical Decision Support Systems do not fully meet the formulated current radiation safety requirements. The majority of clinical decision support system do not offer a choice of the most sparing methods of X-ray examinations (only 31% offer), and do not contain information about the accumulated patient dose for making a decision on the appointment of studies (only 23% contain). The developed methodology for assessing the Clinical Decision Support Systems will allow choosing and implementing the most optimal system in terms of radiation safety into clinical practice.
- Open Access
- 4 April 2023
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (1) , 66-79
Unjustified referrals to radiological examinations and their impact on the collective effective dose of patients in outpatient medical organizations
In recent years, an increase in the collective dose from medical exposure has been recorded annually, which is associated with an increase in the availability of high-tech methods of medical care and an increase of their percentage in the structure of X-ray studies. However, any exposure to ionizing radiation on a patient is associated with an increased risk of stochastic effects. The justification principle is the most effective to ensure the radiation safety of patients. The article considers in detail the experiment on the application of the justification principle in medical organizations. The aim of the study was to evaluate the incidence of unjustified referrals to radiological examinations and their impact on the collective effective dose of patients in outpatient medical organizations. As a result, it was ound, that the collective dose from studies with unjustified referrals contributes 21% to the annual collective dose from X-ray studies in outpatient medical organizations. The result obtained confirms the need to ensure the availability of information on clinical recommendations, the accumulated effective dose and patient characteristics in medical information systems, and proves the importance of using this information when prescribing X-ray radiological studies.
- 4 April 2023
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (1) , 66-79
Open AccessUnjustified referrals to radiological examinations and their impact on the collective effective dose of patients in outpatient medical organizations
In recent years, an increase in the collective dose from medical exposure has been recorded annually, which is associated with an increase in the availability of high-tech methods of medical care and an increase of their percentage in the structure of X-ray studies. However, any exposure to ionizing radiation on a patient is associated with an increased risk of stochastic effects. The justification principle is the most effective to ensure the radiation safety of patients. The article considers in detail the experiment on the application of the justification principle in medical organizations. The aim of the study was to evaluate the incidence of unjustified referrals to radiological examinations and their impact on the collective effective dose of patients in outpatient medical organizations. As a result, it was ound, that the collective dose from studies with unjustified referrals contributes 21% to the annual collective dose from X-ray studies in outpatient medical organizations. The result obtained confirms the need to ensure the availability of information on clinical recommendations, the accumulated effective dose and patient characteristics in medical information systems, and proves the importance of using this information when prescribing X-ray radiological studies.
- Open Access
- 17 October 2022
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 3 (3) , 212-230
Patient dose monitoring software in radiology
An increase in the number of diagnostic procedures using ionizing radiation (computed tomography, interventional procedures, and the use of nuclear medicine) results in an increase in radiation exposure and, consequently, an increase in collective and individual doses of radiation to patients. Diagnostic studies from the international professional community are extensively focusing on issues such as management and dose optimization. Worldwide practice can resolve these issues using software for monitoring patient doses to automatically collect, analyze, and account for patient doses in various types of diagnostic studies. The software allows to obtain data on the doses of patients from X-ray procedures and detailed information about studies, track the total accumulated dose of the patient, and maintain statistics on the device, X-ray laboratory, and the medical organization. It also helps analyze the collected dosimetric data, deduce the causal relationship between dose indications and diagnostic procedure conditions, and monitor the effectiveness of the equipment. The basic capabilities of patient dose monitoring software (DMS) available on the global market were investigated. The major technical requirements for the software functional needed in practical work were defined. Modern DMS have a wide range of possibilities for automated collection, storage, and management of patient radiation exposure data in radiology departments. DMS increase the quality of healthcare services, provide patient safety, and optimize the workflow of medical organizations.
- 17 October 2022
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 3 (3) , 212-230
Open AccessPatient dose monitoring software in radiology
An increase in the number of diagnostic procedures using ionizing radiation (computed tomography, interventional procedures, and the use of nuclear medicine) results in an increase in radiation exposure and, consequently, an increase in collective and individual doses of radiation to patients. Diagnostic studies from the international professional community are extensively focusing on issues such as management and dose optimization. Worldwide practice can resolve these issues using software for monitoring patient doses to automatically collect, analyze, and account for patient doses in various types of diagnostic studies. The software allows to obtain data on the doses of patients from X-ray procedures and detailed information about studies, track the total accumulated dose of the patient, and maintain statistics on the device, X-ray laboratory, and the medical organization. It also helps analyze the collected dosimetric data, deduce the causal relationship between dose indications and diagnostic procedure conditions, and monitor the effectiveness of the equipment. The basic capabilities of patient dose monitoring software (DMS) available on the global market were investigated. The major technical requirements for the software functional needed in practical work were defined. Modern DMS have a wide range of possibilities for automated collection, storage, and management of patient radiation exposure data in radiology departments. DMS increase the quality of healthcare services, provide patient safety, and optimize the workflow of medical organizations.