Youichi Tsubota
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Youichi Tsubota has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Ishibashi
Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, Chiba, Japan
3 shared publications - Junichi H. Kaneko
Graduate School of Engineering, Hokkaido University
3 shared publications Mikio Higuchi
Hokkaido University
3 shared publicationsShusuke Nishiyama
Hokkaido University
3 shared publicationsFumiyuki Fujita
Graduate School of Engineering, Hokkaido University
2 shared publications- Hugo Laffolley
Japan Atomic Energy Agency 2-4 Shirakata Naka-Gun
2 shared publications
Latest Publications
- Open Access
- 19 July 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (30) , 45423-45438
Development of a 3D-Printed Two-Stage Virtual Impactor for Radioactive Aerosol Size Classification and Direct Analysis
Radioactive aerosol size classification is important for exposure assessment and decommissioning operations, particularly at the Fukushima Daiichi Nuclear Power Plant decommissioning site, where airborne particles may be generated or resuspended during remote inspection and debris retrieval. This study presents the development of a two-stage 3D-printed virtual impactor, called μSPLIT, designed to separate aerosols into three aerodynamic diameter classes (>10 μm, 1–10 μm, and <1 μm) while enabling direct postcollection analysis on integrated filters. The objective is to develop a virtual impactor that can be fabricated at a reduced cost and be disposed of easily after usage by incineration, without generating any hazardous human exposure during cleaning and decontamination activities, and free from metallic wastes that are not easily disposed of. The flow path was designed and optimized by computational fluid dynamics and Lagrangian particle tracking, and prototypes were fabricated by stereolithography. Numerical simulations predicted cutoff diameters of 9.0 and 1.3 μm for the first and second stages, respectively, with relatively sharp separation in both cases. The simulations also identified limitations of the current geometry, including small-particle contamination in the minor flow and large-particle contamination in the major flow of the second stage. Dimensional measurements of printed prototypes revealed contraction and corner rounding in the internal channels, confirming the need for fabrication compensation and quality control. Experimental tests with incense smoke provided a preliminary functional check, showing that submicrometric particles were mostly collected in the <1 μm particle class. Additional tests with Rn-progeny-bearing NaCl particles, characterized by a geometric mean aerodynamic diameter of 1.70 μm, produced the highest α activity on the middle filter (1–10 μm particle class), consistent with the expected classification. These results demonstrate the proof of concept of a lightweight and low-cost impactor for simultaneous aerosol size classification and direct radioactive particle analysis, while also identifying key areas requiring further optimization, particularly the second-stage geometry, quantitative wall loss assessment, and validation with standardized aerosols.
- 19 July 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (30) , 45423-45438
Open AccessDevelopment of a 3D-Printed Two-Stage Virtual Impactor for Radioactive Aerosol Size Classification and Direct Analysis
Radioactive aerosol size classification is important for exposure assessment and decommissioning operations, particularly at the Fukushima Daiichi Nuclear Power Plant decommissioning site, where airborne particles may be generated or resuspended during remote inspection and debris retrieval. This study presents the development of a two-stage 3D-printed virtual impactor, called μSPLIT, designed to separate aerosols into three aerodynamic diameter classes (>10 μm, 1–10 μm, and <1 μm) while enabling direct postcollection analysis on integrated filters. The objective is to develop a virtual impactor that can be fabricated at a reduced cost and be disposed of easily after usage by incineration, without generating any hazardous human exposure during cleaning and decontamination activities, and free from metallic wastes that are not easily disposed of. The flow path was designed and optimized by computational fluid dynamics and Lagrangian particle tracking, and prototypes were fabricated by stereolithography. Numerical simulations predicted cutoff diameters of 9.0 and 1.3 μm for the first and second stages, respectively, with relatively sharp separation in both cases. The simulations also identified limitations of the current geometry, including small-particle contamination in the minor flow and large-particle contamination in the major flow of the second stage. Dimensional measurements of printed prototypes revealed contraction and corner rounding in the internal channels, confirming the need for fabrication compensation and quality control. Experimental tests with incense smoke provided a preliminary functional check, showing that submicrometric particles were mostly collected in the <1 μm particle class. Additional tests with Rn-progeny-bearing NaCl particles, characterized by a geometric mean aerodynamic diameter of 1.70 μm, produced the highest α activity on the middle filter (1–10 μm particle class), consistent with the expected classification. These results demonstrate the proof of concept of a lightweight and low-cost impactor for simultaneous aerosol size classification and direct radioactive particle analysis, while also identifying key areas requiring further optimization, particularly the second-stage geometry, quantitative wall loss assessment, and validation with standardized aerosols.
- 13 November 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (16-18) , 1676-1680
Development of α-ray visualization survey meter in high gamma and neutron background environment
A survey meter was developed to reliably detect and visualize surface contamination of suits and objects by α-nuclides in high γ/n-rays background radiation environment. The survey meter features a semi-opaque ZnS:Ag scintillator mounted directly onto a multi-anode photomultiplier tube (MA-PMT) and amplification circuits, ensuring output gain equalization for all channels. α-ray events induce localized light emission in thin-film scintillators. By directly mounting the scintillator, diffusion of light before reaching the MA-PMT is suppressed, concentrating it in just a few channels, thereby facilitating discrimination from background radiation. This design also enables clear visualization of the shape of surface contamination. The prototyped survey meter is capable of responding up to 2.1 × 107 cpm, with no γ-ray response even in high-radiation environments exceeding 1 Sv/h. In actual environments with high background radiation, contamination of ~1/100th of the surface contamination density limit of 4 Bq/cm2 could be reliably detected.
- 13 November 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (16-18) , 1676-1680
Development of α-ray visualization survey meter in high gamma and neutron background environment
A survey meter was developed to reliably detect and visualize surface contamination of suits and objects by α-nuclides in high γ/n-rays background radiation environment. The survey meter features a semi-opaque ZnS:Ag scintillator mounted directly onto a multi-anode photomultiplier tube (MA-PMT) and amplification circuits, ensuring output gain equalization for all channels. α-ray events induce localized light emission in thin-film scintillators. By directly mounting the scintillator, diffusion of light before reaching the MA-PMT is suppressed, concentrating it in just a few channels, thereby facilitating discrimination from background radiation. This design also enables clear visualization of the shape of surface contamination. The prototyped survey meter is capable of responding up to 2.1 × 107 cpm, with no γ-ray response even in high-radiation environments exceeding 1 Sv/h. In actual environments with high background radiation, contamination of ~1/100th of the surface contamination density limit of 4 Bq/cm2 could be reliably detected.
- Open Access
- 14 February 2024
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61 (9) , 1239-1247
Experiences from the cutting of metallic blocks from simulant Fukushima Daiichi fuel debris
- 14 February 2024
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61 (9) , 1239-1247
Open AccessExperiences from the cutting of metallic blocks from simulant Fukushima Daiichi fuel debris
- 15 February 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1030
Development of an in-situ continuous air monitor for the measurement of highly radioactive alpha-emitting particulates (-aerosols) under high humidity environment- 15 February 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1030
Development of an in-situ continuous air monitor for the measurement of highly radioactive alpha-emitting particulates (-aerosols) under high humidity environment- 27 May 2015
- Published by IOP Publishing in Applied Physics Express
- Vol. 8 (6) , 062602
High-temperature scintillation properties of orthorhombic Gd2Si2O7aiming at well logging
- 27 May 2015
- Published by IOP Publishing in Applied Physics Express
- Vol. 8 (6) , 062602
High-temperature scintillation properties of orthorhombic Gd2Si2O7aiming at well logging
- Open Access
- 1 January 2012
- Published by The Atomic Energy Society of Japan in Progress in Nuclear Science and Technology
- Vol. 3, 109-111
Dependence of Crystal Structures and Scintillation Properties on Cerium Concentration in Gd2Si2O7:Ce Powder Synthesized by Solid State Reaction
- 1 January 2012
- Published by The Atomic Energy Society of Japan in Progress in Nuclear Science and Technology
- Vol. 3, 109-111
Open AccessDependence of Crystal Structures and Scintillation Properties on Cerium Concentration in Gd2Si2O7:Ce Powder Synthesized by Solid State Reaction
- Open Access
- 25 February 2011
- Published by The Atomic Energy Society of Japan in Progress in Nuclear Science and Technology
- Vol. 1, 288-291
Luminescence properties and Crystal structures of Pr-doped GPS
- 25 February 2011
- Published by The Atomic Energy Society of Japan in Progress in Nuclear Science and Technology
- Vol. 1, 288-291
Open AccessLuminescence properties and Crystal structures of Pr-doped GPS