Włodzimierz Grabowicz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Włodzimierz Grabowicz has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Joanna Domienik-Andrzejewska
Nofer Institute of Occupational Medicine, Łódź, Poland (Department of Radiological Protection)
2 shared publications - Christelle Huet
Institut de Radioprotection et de Sreté Nucléaire (IRSN), Service de Dosimétrie Externe, Laboratoire de Dosimétrie des Rayonnements Ionisants, Fontenay-aux-Roses, France
1 shared publication - Filip Vanhavere
Institute of Advanced Nuclear Systems, Belgian Nuclear Research Centre SCK.CEN, Boeretang 200, B-2400 Mol, Mol, BELGIUM
1 shared publication - Izabela Warchoł
Department of Interventional Cardiology and Heart Rhythm Diseases, Teaching Hospital No.2 of Medical University of Lodz, Faculty of Medicine, Medical University of Lodz, Zermoskiego 114, 91-647 Lodz, Poland
1 shared publication - Jérémie Dabin
Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
1 shared publication Konrad Masiarek
Medical University of Lodz, Łódź, Poland (Department of Interventional Cardiology and Cardiac Arrythmias)
1 shared publication
Latest Publications
- Open Access
- 29 March 2022
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 35 (5) , 549-560
The effect of lead free cap on the doses of ionizing radiation to the head of interventional cardiologists working in haemodynamic room
Objectives: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap...
- 29 March 2022
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 35 (5) , 549-560
Open AccessThe effect of lead free cap on the doses of ionizing radiation to the head of interventional cardiologists working in haemodynamic room
Objectives: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap...
- Open Access
- 26 February 2022
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (2) , 293-300
Occupational exposure to physicians working with a Zero-Gravity™ protection system in haemodynamic and electrophysiology labs and the assessment of its performance against a standard ceiling suspended shield
A two centre clinical study was performed to analyse exposure levels of cardiac physicians performing electrophysiology and haemodynamic procedures with the use of state of the art Zero-Gravity™ radiation protective system (ZG). The effectiveness of ZG was compared against the commonly used ceiling suspended lead shield (CSS) in a haemodynamic lab. The operator’s exposure was assessed using thermoluminescent dosimeters (TLDs) during both ablation (radiofrequency ablation (RFA) and cryoablation (CRYA)) and angiography and angioplasty procedures (CA/PCI). The dosimeters were placed in multiple body regions: near the left eye, on the left side of the neck, waist and chest, on both hands and ankles during each measurement performed with the use of ZG. In total 29 measurements were performed during 105 procedures. To compare the effectiveness of ZG against CSS an extra 80 measurements were performed with the standard lead apron, thyroid collar and ceiling suspended lead shield during CA/PCI procedures. For ZG, the upper values for the average eye lens and whole body doses per procedure were 4 µSv and 16 µSv for the left eye lens in electrophysiology lab (with additionally used CSS) and haemodynamic lab (without CSS), respectively, and about 10 µSv for the remaining body parts (neck, chest and waist) in both labs. The skin doses to hands and ankles non-protected by the ZG were 5 µSv for the most exposed left finger and left ankle in electrophysiology lab, while in haemodynamic lab 150 µSv and 17 µSv, respectively. The ZG performance was 3 times (p < 0.05) and at least 15 times (p < 0.05) higher for the eye lenses and thoracic region, respectively, compared to CSS (with dosimeters on the apron/collar). However, when only ZG was used slightly higher normalised doses were observed for the left finger compared to CSS (5.88e − 2 Sv/Gym2 vs. 4.31 e − 2 Sv/Gym2, p = 0.016). The study results indicate that ZG performance is superior to CSS. It can be simultaneously used with the ceiling suspended lead shield to ensure the protection to the hands as long as this is not obstructive for the work.
- 26 February 2022
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (2) , 293-300
Open AccessOccupational exposure to physicians working with a Zero-Gravity™ protection system in haemodynamic and electrophysiology labs and the assessment of its performance against a standard ceiling suspended shield
A two centre clinical study was performed to analyse exposure levels of cardiac physicians performing electrophysiology and haemodynamic procedures with the use of state of the art Zero-Gravity™ radiation protective system (ZG). The effectiveness of ZG was compared against the commonly used ceiling suspended lead shield (CSS) in a haemodynamic lab. The operator’s exposure was assessed using thermoluminescent dosimeters (TLDs) during both ablation (radiofrequency ablation (RFA) and cryoablation (CRYA)) and angiography and angioplasty procedures (CA/PCI). The dosimeters were placed in multiple body regions: near the left eye, on the left side of the neck, waist and chest, on both hands and ankles during each measurement performed with the use of ZG. In total 29 measurements were performed during 105 procedures. To compare the effectiveness of ZG against CSS an extra 80 measurements were performed with the standard lead apron, thyroid collar and ceiling suspended lead shield during CA/PCI procedures. For ZG, the upper values for the average eye lens and whole body doses per procedure were 4 µSv and 16 µSv for the left eye lens in electrophysiology lab (with additionally used CSS) and haemodynamic lab (without CSS), respectively, and about 10 µSv for the remaining body parts (neck, chest and waist) in both labs. The skin doses to hands and ankles non-protected by the ZG were 5 µSv for the most exposed left finger and left ankle in electrophysiology lab, while in haemodynamic lab 150 µSv and 17 µSv, respectively. The ZG performance was 3 times (p < 0.05) and at least 15 times (p < 0.05) higher for the eye lenses and thoracic region, respectively, compared to CSS (with dosimeters on the apron/collar). However, when only ZG was used slightly higher normalised doses were observed for the left finger compared to CSS (5.88e − 2 Sv/Gym2 vs. 4.31 e − 2 Sv/Gym2, p = 0.016). The study results indicate that ZG performance is superior to CSS. It can be simultaneously used with the ceiling suspended lead shield to ensure the protection to the hands as long as this is not obstructive for the work.