Sergey Zozulya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sergey Zozulya has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Larysa Levchenko
National Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute», Kyiv
3 shared publications - Iryna Aznaurian
Kyiv National University of Construction and Architecture
2 shared publications - Kyrylo Nikolaiev
Interregional Academy of Personnel Management
2 shared publications - Nataliia Burdeina
Kyiv National University of Construction and Architecture
2 shared publications - Oksana Tykhenko
National Aviation University
2 shared publications - Olena Panova
Kyiv National University of Construction and Architecture
2 shared publications
Latest Publications
- Open Access
- 25 October 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 5 (10 (131)) , 45-52
Applying heterogeneous building materials for the protection of people against electromagnetic radiation
The object of this study is the processes of shielding electromagnetic radiation by building and facing materials. The research is aimed at solving the problem of ensuring the electromagnetic safety of people by improving the composition and structures of building and facing materials. Means for improving the electromagnetic safety of people under industrial and domestic conditions using non-homogeneous building materials have been determined. The shielding properties of reinforced concrete structures were studied. A methodology for increasing their efficiency depending on the amplitude-frequency characteristics of the radiation that needs shielding has been devised. The efficiency of electromagnetic radiation shielding by heterogeneous dielectric building materials based on cement concrete and basalt fibers was determined. It was established that shielding through the refraction of electromagnetic waves on inhomogeneities does not give an acceptable effect. The expediency of covering basalt fibers with a conductive substance to increase the protective properties of materials was substantiated. The protective properties of flat facing material with carbonyl iron content were studied. It has been shown that the properties of materials can be effectively controlled by adjusting the filler. The material's transmission coefficient of ultra-high frequency electromagnetic radiation does not exceed 0.40, and the reflection coefficient – 0.25 with a filler content in the base of 14–15 % by volume. This makes it possible to simultaneously ensure the electromagnetic safety of people and the stable functioning of wireless communication devices. The advantage of the material is the low coefficients of reflection of electromagnetic waves, which does not lead to deterioration of the electromagnetic situation in other areas where people stay. It has been established that the addition of boron nitride to the facing material significantly increases the thermal insulation characteristics of the coating and contributes to the solution of energy saving problems. Adding a layer containing boron nitride to the material provides thermal conductivity coefficients of 0.030–0.031 W/m·K, which is better than known analogs
- 25 October 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 5 (10 (131)) , 45-52
Open AccessApplying heterogeneous building materials for the protection of people against electromagnetic radiation
The object of this study is the processes of shielding electromagnetic radiation by building and facing materials. The research is aimed at solving the problem of ensuring the electromagnetic safety of people by improving the composition and structures of building and facing materials. Means for improving the electromagnetic safety of people under industrial and domestic conditions using non-homogeneous building materials have been determined. The shielding properties of reinforced concrete structures were studied. A methodology for increasing their efficiency depending on the amplitude-frequency characteristics of the radiation that needs shielding has been devised. The efficiency of electromagnetic radiation shielding by heterogeneous dielectric building materials based on cement concrete and basalt fibers was determined. It was established that shielding through the refraction of electromagnetic waves on inhomogeneities does not give an acceptable effect. The expediency of covering basalt fibers with a conductive substance to increase the protective properties of materials was substantiated. The protective properties of flat facing material with carbonyl iron content were studied. It has been shown that the properties of materials can be effectively controlled by adjusting the filler. The material's transmission coefficient of ultra-high frequency electromagnetic radiation does not exceed 0.40, and the reflection coefficient – 0.25 with a filler content in the base of 14–15 % by volume. This makes it possible to simultaneously ensure the electromagnetic safety of people and the stable functioning of wireless communication devices. The advantage of the material is the low coefficients of reflection of electromagnetic waves, which does not lead to deterioration of the electromagnetic situation in other areas where people stay. It has been established that the addition of boron nitride to the facing material significantly increases the thermal insulation characteristics of the coating and contributes to the solution of energy saving problems. Adding a layer containing boron nitride to the material provides thermal conductivity coefficients of 0.030–0.031 W/m·K, which is better than known analogs
- Open Access
- 30 April 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (10 (128)) , 26-33
Study of air deionization factors
The object of research is the dynamics in the concentration of air ions and suspended particles in atmospheric air and in supply-exhaust ventilation systems. An urgent task is to determine the factors and obtain quantitative data on the deionization of the atmospheric air that enters the environment where people live. Quantitative data on changes in the concentration of air ions depending on the time of day, temperature, and relative air humidity have been established. It was shown that even in the absence of significant man-made influence on the concentration of suspended particles, this indicator is at least 7000 cm-3. In the presence of wind, this indicator reaches 30000 cm-3 and higher. Measurement of the spectrum of suspended particles in the range of 0,3–6,0 μm showed that the predominant fraction is particles with sizes of about 3 μm. Studies have been conducted on changes in the concentrations of air ions in supply-exhaust ventilation systems. It was established that in the air duct made of galvanized iron, which has a length of 16 m, the concentration of negative air ions is reduced by 67 %, and positive by 78 %. Laboratory studies of air deionization in air ducts made of different materials were carried out. There is significant air deionization in metal and cardboard ducts while it is absent in wooden ducts. This indicates the electrical nature of deionization. A calculation method for forecasting the aero-ionic mode of premises, taking into account the factors of air deionization, is proposed. For rooms with supply-exhaust ventilation, a calculation apparatus is proposed taking into account the air exchange rate (the number of complete air changes per unit of time). The results make it possible to choose the required performance of artificial air ionization devices for normalizing the aero-ionic regimes in the premises
- 30 April 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (10 (128)) , 26-33
Open AccessStudy of air deionization factors
The object of research is the dynamics in the concentration of air ions and suspended particles in atmospheric air and in supply-exhaust ventilation systems. An urgent task is to determine the factors and obtain quantitative data on the deionization of the atmospheric air that enters the environment where people live. Quantitative data on changes in the concentration of air ions depending on the time of day, temperature, and relative air humidity have been established. It was shown that even in the absence of significant man-made influence on the concentration of suspended particles, this indicator is at least 7000 cm-3. In the presence of wind, this indicator reaches 30000 cm-3 and higher. Measurement of the spectrum of suspended particles in the range of 0,3–6,0 μm showed that the predominant fraction is particles with sizes of about 3 μm. Studies have been conducted on changes in the concentrations of air ions in supply-exhaust ventilation systems. It was established that in the air duct made of galvanized iron, which has a length of 16 m, the concentration of negative air ions is reduced by 67 %, and positive by 78 %. Laboratory studies of air deionization in air ducts made of different materials were carried out. There is significant air deionization in metal and cardboard ducts while it is absent in wooden ducts. This indicates the electrical nature of deionization. A calculation method for forecasting the aero-ionic mode of premises, taking into account the factors of air deionization, is proposed. For rooms with supply-exhaust ventilation, a calculation apparatus is proposed taking into account the air exchange rate (the number of complete air changes per unit of time). The results make it possible to choose the required performance of artificial air ionization devices for normalizing the aero-ionic regimes in the premises
- Open Access
- 30 March 2024
- Published by Kyiv National University of Construction and Architecture in Problems of Water supply, Sewerage and Hydraulic
- No. 46,p. 48-64
«Green» structures in the urbanized environment: studying the impact of «green» roofs on environmental parameters and rainwater quality. Bibliographic review
A quantitative analysis of the most cited articles published in the Scopus scientometric database by 2023 is carried out. It is shown that most of the publications, the object of study of which are "green" structures, focus on the study of "green" roofs. It is shown that since 1981, the number of studies on green roofs has been steadily increasing: approximately 45% of articles focus on the benefits in terms of thermal impact and thermal insulation, 18% on rainwater drainage, 15% on air quality, 5% on the noise-absorbing properties of green roofs, and 17% on the costs of building and operating green roofs, recreational facilities, fire protection, and other related issues. The requirements and commonly used materials for a standard green roof are described, as well as the percentage of scientific publications, depending on the functions and layers of green roof construction involved. An analysis of the most cited scientific studies on the impact of green roof systems on wastewater quality was conducted. It is shown that the results of the studies presented in these publications indicate the need for further study of the impact of a "green" roof on the amount of pollution in the water flowing from its surface. It is emphasized that further research should focus on the structural layers of the roof (thickness and materials used), namely the thickness and types of substrate layers, as well as on the conditions of plant care (e.g., fertilization), especially on intensive green roofs. In addition, it should be studied and analyzed how the retention of rainwater by plants and the soil layer of a green roof affects the relative humidity of the air near the building during periods without rain. The most cited scientific studies on the reduction of air pollutants by means of green roofs are analyzed. It is concluded that future research should focus on the study of plant species that are well adapted to growing on roofs (in temperate climates) and most effectively carry out the process of photosynthesis, absorbing CO2 and releasing O2 into the atmosphere around the building. The article analyzes the most cited scientific publications on the noise-absorbing properties of green roofs. It is substantiated that it is necessary to maximize the percentage of green roofs implementation on all buildings and structures in the city so that green roofs can significantly affect the quality of the environment in urbanized areas. Проведено кількісний аналіз найбільш цитованих статей, опублікованих у наукометричній базі даних Scopus до 2023 року. Показано, що більшість публікацій, об'єктом вивчення яких стали «зелені» конструкції, фокусуються на дослідженні «зелених» дахів. Наведено, що з 1981 року кількість досліджень «зелених» дахів неухильно зростає: приблизно 45% статей зосереджені на вивченні переваг у контексті термічного впливу та теплоізоляції, 18% – відведення дощової води, 15% – на якості повітря, 5% – на шумопоглинальних властивостях «зелених» дахів та 17% – витрати на будівництво та експлуатацію «зелених» дахів, рекреаційні об'єкти, протипожежний захист та інші супутні питання. Описано вимоги та загальновживані матеріали для стандартного «зеленого» даху, а також відсоткова частка наукових публікацій, залежно від функцій та задіяних шарів конструкції «зелених» дахів. Проведено аналіз найбільш цитованих наукових досліджень щодо впливу систем «зелених» дахів на якість дощового стоку. Показано, що результати досліджень, викладені в наведених публікаціях, свідчать про необхідність подальшого вивчення впливу «зеленого» даху на обсяг забруднення у воді, що стікає з її поверхні. Підкреслено, що подальші дослідження повинні бути зосереджені на конструктивних шарах даху (товщина і використовувані матеріали), а саме на товщині та видах шарів підкладки, а також на умовах догляду за рослинами (наприклад, внесення добрив), особливо на інтенсивних «зелених» дахах. Крім того, повинно бути вивчено та проаналізовано, як затримка дощової води рослинами та шаром ґрунту «зеленого» даху впливає на відносну вологість повітря поблизу будівлі в періоди без дощу. Виділено сукупність факторів, які відіграють головну роль в процесі впливу «зелених» дахів на якість дощового стоку. Здійснено аналіз найбільш цитованих наукових досліджень, присвячених зменшенню забруднюючих речовин повітря за допомогою «зелених» дахів. Зроблено висновок, що...
- 30 March 2024
- Published by Kyiv National University of Construction and Architecture in Problems of Water supply, Sewerage and Hydraulic
- No. 46,p. 48-64
Open Access«Green» structures in the urbanized environment: studying the impact of «green» roofs on environmental parameters and rainwater quality. Bibliographic review
A quantitative analysis of the most cited articles published in the Scopus scientometric database by 2023 is carried out. It is shown that most of the publications, the object of study of which are "green" structures, focus on the study of "green" roofs. It is shown that since 1981, the number of studies on green roofs has been steadily increasing: approximately 45% of articles focus on the benefits in terms of thermal impact and thermal insulation, 18% on rainwater drainage, 15% on air quality, 5% on the noise-absorbing properties of green roofs, and 17% on the costs of building and operating green roofs, recreational facilities, fire protection, and other related issues. The requirements and commonly used materials for a standard green roof are described, as well as the percentage of scientific publications, depending on the functions and layers of green roof construction involved. An analysis of the most cited scientific studies on the impact of green roof systems on wastewater quality was conducted. It is shown that the results of the studies presented in these publications indicate the need for further study of the impact of a "green" roof on the amount of pollution in the water flowing from its surface. It is emphasized that further research should focus on the structural layers of the roof (thickness and materials used), namely the thickness and types of substrate layers, as well as on the conditions of plant care (e.g., fertilization), especially on intensive green roofs. In addition, it should be studied and analyzed how the retention of rainwater by plants and the soil layer of a green roof affects the relative humidity of the air near the building during periods without rain. The most cited scientific studies on the reduction of air pollutants by means of green roofs are analyzed. It is concluded that future research should focus on the study of plant species that are well adapted to growing on roofs (in temperate climates) and most effectively carry out the process of photosynthesis, absorbing CO2 and releasing O2 into the atmosphere around the building. The article analyzes the most cited scientific publications on the noise-absorbing properties of green roofs. It is substantiated that it is necessary to maximize the percentage of green roofs implementation on all buildings and structures in the city so that green roofs can significantly affect the quality of the environment in urbanized areas. Проведено кількісний аналіз найбільш цитованих статей, опублікованих у наукометричній базі даних Scopus до 2023 року. Показано, що більшість публікацій, об'єктом вивчення яких стали «зелені» конструкції, фокусуються на дослідженні «зелених» дахів. Наведено, що з 1981 року кількість досліджень «зелених» дахів неухильно зростає: приблизно 45% статей зосереджені на вивченні переваг у контексті термічного впливу та теплоізоляції, 18% – відведення дощової води, 15% – на якості повітря, 5% – на шумопоглинальних властивостях «зелених» дахів та 17% – витрати на будівництво та експлуатацію «зелених» дахів, рекреаційні об'єкти, протипожежний захист та інші супутні питання. Описано вимоги та загальновживані матеріали для стандартного «зеленого» даху, а також відсоткова частка наукових публікацій, залежно від функцій та задіяних шарів конструкції «зелених» дахів. Проведено аналіз найбільш цитованих наукових досліджень щодо впливу систем «зелених» дахів на якість дощового стоку. Показано, що результати досліджень, викладені в наведених публікаціях, свідчать про необхідність подальшого вивчення впливу «зеленого» даху на обсяг забруднення у воді, що стікає з її поверхні. Підкреслено, що подальші дослідження повинні бути зосереджені на конструктивних шарах даху (товщина і використовувані матеріали), а саме на товщині та видах шарів підкладки, а також на умовах догляду за рослинами (наприклад, внесення добрив), особливо на інтенсивних «зелених» дахах. Крім того, повинно бути вивчено та проаналізовано, як затримка дощової води рослинами та шаром ґрунту «зеленого» даху впливає на відносну вологість повітря поблизу будівлі в періоди без дощу. Виділено сукупність факторів, які відіграють головну роль в процесі впливу «зелених» дахів на якість дощового стоку. Здійснено аналіз найбільш цитованих наукових досліджень, присвячених зменшенню забруднюючих речовин повітря за допомогою «зелених» дахів. Зроблено висновок, що...
- Open Access
- 1 January 2024
- Published by Wiley in Journal of Control Science and Engineering
- Vol. 2024 (1)
Computer‐Integrated Monitoring Technology with Support‐Decision of Unauthorized Disturbance of Methane Sensor Functioning for Coal Mines
In longwall coal mining, high methane concentrations pose a challenge. Cyber‐physical air and gas protection systems ensure operational safety. However, safeguarding methane sensors from unauthorized interference is a key issue. This research aims to develop an intelligent method for detecting disturbances in methane sensor operation, preventing mining emergencies. The methodological basis for achieving the research goal is an integrated approach using proven scientific methods: analysis of existing scientific and practical results; computer modeling, development, and creation of prototypes of computer‐integrated stands for studying the processes of external influence on measurement results. The primary advantage of the proposed method is the software implementation of the specified approach on the existing computer‐integrated modules and sensor hardware platform. This allows for the identification of unregulated modes of operation without the need for hardware redundancy during the implementation of measurement modules for information processing in cyber‐physical systems. The structure of computer‐aided monitoring with decision support has been substantiated and developed, which implements the mathematical apparatus of the proposed method for detecting unauthorized interference with sensor operation modes. The implementation of the developed method of detecting unauthorized interference in the regulated mode of the methane concentration sensor made it possible to detect such interference from 15 seconds, if the concentration is more than 1.45%, to 20 seconds during the action of the minimum methane concentration of 0.24%. The specified time interval from 15 to 20 seconds is approximately equal to the time constant of the transition process, which varies depending on the degree of tightness of its sensitive element.
- 1 January 2024
- Published by Wiley in Journal of Control Science and Engineering
- Vol. 2024 (1)
Open AccessComputer‐Integrated Monitoring Technology with Support‐Decision of Unauthorized Disturbance of Methane Sensor Functioning for Coal Mines
In longwall coal mining, high methane concentrations pose a challenge. Cyber‐physical air and gas protection systems ensure operational safety. However, safeguarding methane sensors from unauthorized interference is a key issue. This research aims to develop an intelligent method for detecting disturbances in methane sensor operation, preventing mining emergencies. The methodological basis for achieving the research goal is an integrated approach using proven scientific methods: analysis of existing scientific and practical results; computer modeling, development, and creation of prototypes of computer‐integrated stands for studying the processes of external influence on measurement results. The primary advantage of the proposed method is the software implementation of the specified approach on the existing computer‐integrated modules and sensor hardware platform. This allows for the identification of unregulated modes of operation without the need for hardware redundancy during the implementation of measurement modules for information processing in cyber‐physical systems. The structure of computer‐aided monitoring with decision support has been substantiated and developed, which implements the mathematical apparatus of the proposed method for detecting unauthorized interference with sensor operation modes. The implementation of the developed method of detecting unauthorized interference in the regulated mode of the methane concentration sensor made it possible to detect such interference from 15 seconds, if the concentration is more than 1.45%, to 20 seconds during the action of the minimum methane concentration of 0.24%. The specified time interval from 15 to 20 seconds is approximately equal to the time constant of the transition process, which varies depending on the degree of tightness of its sensitive element.
- Open Access
- 25 March 2022
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 1 (168) , 129-133
FORECASTING THE AEROIN COMPOSITION OF AIR IN THE PRESENCE OF NATURAL AND ARTIFICIAL SOURCES OF IONIZATION
It is shown that for the design of buildings and individual rooms with normative concentrations of light air ions of both polarities, a preliminary estimated assessment of the dynamics of this indicator in space and time is appropriate. In the general case, it is possible to use the continuity equation for weakly ionized plasma for one direction. This is due to the low concentration of air ions in the air. The ratio of molecular kinetic theory of gases is used to determine the necessary indicators - the average lifetime of air ions, free path length. To determine the average speed - Maxwell's distribution. It is shown that the propagation of air ions due to diffusion processes is insignificant, and the corresponding calculations have large errors. Calculations on the propagation of air ions by directed air movement from the source of artificial ionization are given. The distribution of air ion concentrations can be most accurately calculated taking into account their recombination, deposition on heavy air ions and neutral suspended parts (fine dust and aerosols). Relevant coefficients are mostly issued from reference sources. If there are electrostatic fields in the premises, generated due to the triboelectric effect and other factors, it is necessary to take into account the deposition of air ions on these surfaces. In order to correctly determine the concentrations of air ions, in addition to the values of the mobility of negative and positive air ions, data on electrostatic field strengths are required. The values of such fields are unpredictable, so they are measured by appropriate instruments in similar conditions. Verification of calculated data using electrostatic charge meters and air ion counter proved the reasonable convergence of expected and actual data. It is advisable to develop two- and three-dimensional models of the propagation of air ions of both polarities in rooms of different purposes, configurations of equipment placement, the presence of artificial ionization sources and directional air movement.
- 25 March 2022
- Published by O.M.Beketov National University of Urban Economy in Kharkiv in Municipal economy of cities
- Vol. 1 (168) , 129-133
Open AccessFORECASTING THE AEROIN COMPOSITION OF AIR IN THE PRESENCE OF NATURAL AND ARTIFICIAL SOURCES OF IONIZATION
It is shown that for the design of buildings and individual rooms with normative concentrations of light air ions of both polarities, a preliminary estimated assessment of the dynamics of this indicator in space and time is appropriate. In the general case, it is possible to use the continuity equation for weakly ionized plasma for one direction. This is due to the low concentration of air ions in the air. The ratio of molecular kinetic theory of gases is used to determine the necessary indicators - the average lifetime of air ions, free path length. To determine the average speed - Maxwell's distribution. It is shown that the propagation of air ions due to diffusion processes is insignificant, and the corresponding calculations have large errors. Calculations on the propagation of air ions by directed air movement from the source of artificial ionization are given. The distribution of air ion concentrations can be most accurately calculated taking into account their recombination, deposition on heavy air ions and neutral suspended parts (fine dust and aerosols). Relevant coefficients are mostly issued from reference sources. If there are electrostatic fields in the premises, generated due to the triboelectric effect and other factors, it is necessary to take into account the deposition of air ions on these surfaces. In order to correctly determine the concentrations of air ions, in addition to the values of the mobility of negative and positive air ions, data on electrostatic field strengths are required. The values of such fields are unpredictable, so they are measured by appropriate instruments in similar conditions. Verification of calculated data using electrostatic charge meters and air ion counter proved the reasonable convergence of expected and actual data. It is advisable to develop two- and three-dimensional models of the propagation of air ions of both polarities in rooms of different purposes, configurations of equipment placement, the presence of artificial ionization sources and directional air movement.
- Open Access
- 25 February 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (10(115)) , 24-30
Monitoring and management ion concentrations in the air of industrial and public premises
This paper reports a substantiated method and a designed device for controlling the concentrations of air ions in premises in accordance with the European standards SBM 2015. The use of an ultrasonic humidifier with a capacity of 25 W for two hours increases the concentration of negative ions around the device from 240 to 560 cm-3, positive ones ‒ from 260 to 410 cm-3. The intensity of the electrostatic field of a polymeric coating decreases from 5.1 to 0.2 kV/m. The disadvantage of the humidifier is a small radius of influence (1.0–1.5 m) and the inability to control the polarity of ions. It has been experimentally established that air cooling systems (split systems) deionize the air of the premises. Degrees of deionization and dominating polarity are unpredictable and different for devices of different manufacturers and brands. To control the ion composition of the air simultaneously with the maintenance of normative relative humidity and stresses of static fields, the structure was proposed and the effectiveness of a bipolar ultrasonic air ionizer with adjusted performance and dominating polarity has been tested. The maximum productivity of the ionizer is 4,000–5,000 cm-3. The radius of exposure is 5 m (reducing the concentration of ions with a distance to 500 cm-3). To pass the ionized air through an air capacitor, the number and predominant polarity of air ions are regulated by the polarity and voltage on the covers of the capacitor. It was established that in order to service a room with an area of 50 m2, an ultrasonic emitter with a capacity of 25 W would suffice. The adjustability of the device performance makes it possible to reduce or increase the service area. The ability to purify air from suspended particles is shown. During the two hours of operation of the ionizer, the dust content decreased from 4.3–4.4 mg/m3 to 1.4–1.6 mg/m3.
- 25 February 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (10(115)) , 24-30
Open AccessMonitoring and management ion concentrations in the air of industrial and public premises
This paper reports a substantiated method and a designed device for controlling the concentrations of air ions in premises in accordance with the European standards SBM 2015. The use of an ultrasonic humidifier with a capacity of 25 W for two hours increases the concentration of negative ions around the device from 240 to 560 cm-3, positive ones ‒ from 260 to 410 cm-3. The intensity of the electrostatic field of a polymeric coating decreases from 5.1 to 0.2 kV/m. The disadvantage of the humidifier is a small radius of influence (1.0–1.5 m) and the inability to control the polarity of ions. It has been experimentally established that air cooling systems (split systems) deionize the air of the premises. Degrees of deionization and dominating polarity are unpredictable and different for devices of different manufacturers and brands. To control the ion composition of the air simultaneously with the maintenance of normative relative humidity and stresses of static fields, the structure was proposed and the effectiveness of a bipolar ultrasonic air ionizer with adjusted performance and dominating polarity has been tested. The maximum productivity of the ionizer is 4,000–5,000 cm-3. The radius of exposure is 5 m (reducing the concentration of ions with a distance to 500 cm-3). To pass the ionized air through an air capacitor, the number and predominant polarity of air ions are regulated by the polarity and voltage on the covers of the capacitor. It was established that in order to service a room with an area of 50 m2, an ultrasonic emitter with a capacity of 25 W would suffice. The adjustability of the device performance makes it possible to reduce or increase the service area. The ability to purify air from suspended particles is shown. During the two hours of operation of the ionizer, the dust content decreased from 4.3–4.4 mg/m3 to 1.4–1.6 mg/m3.