Ulf Lorenzen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ulf Lorenzen has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Almut Kalz
University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany
1 shared publication - Andrea Köser
Klinik für Anästhesiologie und Operative Intensivmedizin, Campus Kiel, Universitätsklinikum Schleswig-Holstein, Kiel, Deutschland
1 shared publication - Andreas Meinzer
Department of General, Visceral, Thoracic, Transplant and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
1 shared publication - Anna Saltner
Department of General-, Visceral-, Thoracic-, Transplant- and Pediatric Surgery, UKSH University Hospital of Schleswig-Holstein Kiel Campus, Arnold-Heller-Strasse 3, 24105 Kiel, Germany
1 shared publication - Arnold Kaltwasser
Fachbereichsleitung Weiterbildung an der Akademie der Kreiskliniken Reutlingen GmbH
1 shared publication - Bjarne Schmalbach
Berufsfeuerwehr Kiel, Kiel, Deutschland
1 shared publication
Latest Publications
- Open Access
- 12 March 2026
- Published by Wiley in Nursing in Critical Care
- Vol. 31 (2) , e70443
INPRESS : INvasive PRESSure Monitoring Knowledge and Practice Survey
Background: In patients on Intensive Care Units (ICU), invasive arterial pressure monitoring with closed transducer systems is widely used, yet the accuracy of measurement depends on correct zeroing, levelling and interpretation of arterial waveforms. Aim: The aim was to assess the knowledge and practice of clinicians (nurses, physicians, anaesthesia/operation technicians) working in critical care, operating theatres and emergency departments about arterial blood pressure assessment and managing the closed transducer system. Study Design: A cross‐sectional online survey was conducted in Germany in May 2025. The questionnaire included 26 single‐ and multiple‐response items on zeroing, transducer level, arterial waveform, phlebostatic axis and practical handling of the arterial line system. Data were analysed using descriptive statistics and Fisher's exact test to assess associations between knowledge and professional experience or institutional setting. Results: A total of 303 clinicians participated, the majority being ICU nurses n = 245 (81%), with n = 21 (7%) answering all questions correctly. The percentage of correct answers in multiple questions were in the sections about zeroing procedures n = 34–48 (11%–16%), transducer reference levels n = 5–232 (2%–77%), arterial pressure waveform n = 33–53 (11%–17%) and phlebostatic axis identification n = 11–101 (4%–33%). Recognition of hydrostatic, gravitational effects was higher n = 232 (77%), but scenario‐based questions were correctly answered by only half. Practical handling showed variation, with n = 147 (48%) reporting correct pressure bag inflation and n = 147 (48%) avoiding heparin in flush solutions. More years of experience and employment in tertiary centres were associated with higher accuracy. Conclusions: Clinicians demonstrated limited knowledge of invasive blood pressure monitoring, with significant variability across domains. Structured education, protocols and simulation‐based training are needed to improve accuracy and safety. Relevance to Clinical Practice: Strengthening haemodynamic monitoring competence is essential to ensure reliable, homogenous measurements, reduce errors and enhance patient safety.
- 12 March 2026
- Published by Wiley in Nursing in Critical Care
- Vol. 31 (2) , e70443
Open AccessINPRESS : INvasive PRESSure Monitoring Knowledge and Practice Survey
Background: In patients on Intensive Care Units (ICU), invasive arterial pressure monitoring with closed transducer systems is widely used, yet the accuracy of measurement depends on correct zeroing, levelling and interpretation of arterial waveforms. Aim: The aim was to assess the knowledge and practice of clinicians (nurses, physicians, anaesthesia/operation technicians) working in critical care, operating theatres and emergency departments about arterial blood pressure assessment and managing the closed transducer system. Study Design: A cross‐sectional online survey was conducted in Germany in May 2025. The questionnaire included 26 single‐ and multiple‐response items on zeroing, transducer level, arterial waveform, phlebostatic axis and practical handling of the arterial line system. Data were analysed using descriptive statistics and Fisher's exact test to assess associations between knowledge and professional experience or institutional setting. Results: A total of 303 clinicians participated, the majority being ICU nurses n = 245 (81%), with n = 21 (7%) answering all questions correctly. The percentage of correct answers in multiple questions were in the sections about zeroing procedures n = 34–48 (11%–16%), transducer reference levels n = 5–232 (2%–77%), arterial pressure waveform n = 33–53 (11%–17%) and phlebostatic axis identification n = 11–101 (4%–33%). Recognition of hydrostatic, gravitational effects was higher n = 232 (77%), but scenario‐based questions were correctly answered by only half. Practical handling showed variation, with n = 147 (48%) reporting correct pressure bag inflation and n = 147 (48%) avoiding heparin in flush solutions. More years of experience and employment in tertiary centres were associated with higher accuracy. Conclusions: Clinicians demonstrated limited knowledge of invasive blood pressure monitoring, with significant variability across domains. Structured education, protocols and simulation‐based training are needed to improve accuracy and safety. Relevance to Clinical Practice: Strengthening haemodynamic monitoring competence is essential to ensure reliable, homogenous measurements, reduce errors and enhance patient safety.
- Open Access
- 7 March 2024
- Published by Springer Nature in Medizinische Klinik - Intensivmedizin und Notfallmedizin
- Vol. 120 (1) , 57-64
Arztbegleitete Interhospitaltransporte – eine Analyse aus Schleswig-Holstein
Zusammenfassung: Hintergrund: Durch Veränderungen in der Krankenhauslandschaft nehmen Interhospitaltransporte (IHT) einen immer höheren Stellenwert im Rettungsdienst ein. Durch die Spannbreite der Anforderungen hinsichtlich Personals und Rettungsmittel bedürfen diese Transporte einer sorgfältigen Einsatzplanung. Zielsetzung: Um den Status quo zu untersuchen, führten wir eine Analyse im Versorgungsbereich der Integrierten Regionalleitstelle Mitte (IRLS-Mitte) in Schleswig-Holstein durch. Material und Methoden: Im Zeitraum vom 01.10.2021 bis 30.09.2022 wurden arztbegleitete IHT analysiert. Ergebnisse: Von insgesamt 158.823 dokumentierten Einsätzen der ILRS-Mitte konnten 2264 (1,4 %) Datensätze als arztbegleitete IHT identifiziert und eingeschlossen werden. Es erfolgten 1389 Transporte (61,4 %) durch spezialisierte Rettungsmittel, sowie 875 (38,6 %) durch Rettungsmittel der Primärversorgung. Der Einsatz von Primärrettungsmittel erfolgte schwerpunktmäßig bei zeitkritischen Verlegungen und außerhalb der Dienstzeiten des Intensivtransportwagens (ITW)/Verlegungseinsatzfahrzeugs (VEF), 21,2 % erfolgten luftgebunden. Bei 43,1 % aller Transporte handelte es sich um Aufwärtsverlegungen. Diskussion: Arztbegleitete IHT nehmen einen relevanten Anteil am Einsatzspektrum des Rettungsdiensts ein und betreffen sowohl Rettungsmittel der Primärversorgung als auch spezialisierte Rettungsmittel. Außerhalb der Vorhaltezeiten von ITW/VEF übernehmen Notarzteinsatzfahrzeuge (NEF) und Rettungstransporthubschrauber (RTH) vorrangig die Transporte. Für die nächtlichen Notfalltransporte ist aufgrund des Zeitvorteils eine Ausweitung der luftgebundenen Verlegungskapazitäten zu erwägen. Für weniger dringliche Transporte könnte eine Anpassung der Kapazitäten spezialisierter bodengebundener Rettungsmittel in Schleswig-Holstein sinnvoll sein.
- 7 March 2024
- Published by Springer Nature in Medizinische Klinik - Intensivmedizin und Notfallmedizin
- Vol. 120 (1) , 57-64
Open AccessArztbegleitete Interhospitaltransporte – eine Analyse aus Schleswig-Holstein
Zusammenfassung: Hintergrund: Durch Veränderungen in der Krankenhauslandschaft nehmen Interhospitaltransporte (IHT) einen immer höheren Stellenwert im Rettungsdienst ein. Durch die Spannbreite der Anforderungen hinsichtlich Personals und Rettungsmittel bedürfen diese Transporte einer sorgfältigen Einsatzplanung. Zielsetzung: Um den Status quo zu untersuchen, führten wir eine Analyse im Versorgungsbereich der Integrierten Regionalleitstelle Mitte (IRLS-Mitte) in Schleswig-Holstein durch. Material und Methoden: Im Zeitraum vom 01.10.2021 bis 30.09.2022 wurden arztbegleitete IHT analysiert. Ergebnisse: Von insgesamt 158.823 dokumentierten Einsätzen der ILRS-Mitte konnten 2264 (1,4 %) Datensätze als arztbegleitete IHT identifiziert und eingeschlossen werden. Es erfolgten 1389 Transporte (61,4 %) durch spezialisierte Rettungsmittel, sowie 875 (38,6 %) durch Rettungsmittel der Primärversorgung. Der Einsatz von Primärrettungsmittel erfolgte schwerpunktmäßig bei zeitkritischen Verlegungen und außerhalb der Dienstzeiten des Intensivtransportwagens (ITW)/Verlegungseinsatzfahrzeugs (VEF), 21,2 % erfolgten luftgebunden. Bei 43,1 % aller Transporte handelte es sich um Aufwärtsverlegungen. Diskussion: Arztbegleitete IHT nehmen einen relevanten Anteil am Einsatzspektrum des Rettungsdiensts ein und betreffen sowohl Rettungsmittel der Primärversorgung als auch spezialisierte Rettungsmittel. Außerhalb der Vorhaltezeiten von ITW/VEF übernehmen Notarzteinsatzfahrzeuge (NEF) und Rettungstransporthubschrauber (RTH) vorrangig die Transporte. Für die nächtlichen Notfalltransporte ist aufgrund des Zeitvorteils eine Ausweitung der luftgebundenen Verlegungskapazitäten zu erwägen. Für weniger dringliche Transporte könnte eine Anpassung der Kapazitäten spezialisierter bodengebundener Rettungsmittel in Schleswig-Holstein sinnvoll sein.
- Open Access
Evaluation of the Versius Robotic System for Infant Surgery—A Study in Piglets of Less than 10 kg Body Weight
Background: We were able to demonstrate the feasibility of a new robotic system (Versius, CMR Surgical, Cambridge, UK) for procedures in small inanimate cavities. The aim of this consecutive study was to test the Versius® system for its feasibility, performance, and safety of robotic abdominal and thoracic surgery in piglets simulating infants with a body weight lower than 10 kg. Methods: A total of 24 procedures (from explorative laparoscopy to thoracoscopic esophageal repair) were performed in 4 piglets with a mean age of 12 days and a mean body weight of 6.4 (7–7.5) kg. Additional urological procedures were performed after euthanasia of the piglet. The Versius® robotic system was used with 5 mm wristed instruments and a 10 mm 3D 0° or 30° camera. The setup consisted of the master console and three to four separate arms. The performance of the procedure, the size, position, and the distance between the ports, the external and internal collisions, and complications of the procedures were recorded and analyzed. Results: We were able to perform all surgical procedures as planned. We encountered neither surgical nor robot-associated complications in the live model. Whereas all abdominal procedures could be performed successfully under general anesthesia, one piglet was euthanized early before the thoracic interventions, likely due to pulmonary inflammatory response. Technical limitations were based on the size of the camera (10 mm) being too large and the minimal insertion depth of the instruments for calibration of the fulcrum point. Conclusions: Robotic surgery on newborns and infants appears technically feasible with the Versius® system. Software adjustments for fulcrum point calibration need to be implemented by the manufacturer as a result of our study. To further evaluate the Versius® system, prospective trials are needed, comparing it to open and laparoscopic surgery as well as to other robotic systems.
Open AccessEvaluation of the Versius Robotic System for Infant Surgery—A Study in Piglets of Less than 10 kg Body Weight
Background: We were able to demonstrate the feasibility of a new robotic system (Versius, CMR Surgical, Cambridge, UK) for procedures in small inanimate cavities. The aim of this consecutive study was to test the Versius® system for its feasibility, performance, and safety of robotic abdominal and thoracic surgery in piglets simulating infants with a body weight lower than 10 kg. Methods: A total of 24 procedures (from explorative laparoscopy to thoracoscopic esophageal repair) were performed in 4 piglets with a mean age of 12 days and a mean body weight of 6.4 (7–7.5) kg. Additional urological procedures were performed after euthanasia of the piglet. The Versius® robotic system was used with 5 mm wristed instruments and a 10 mm 3D 0° or 30° camera. The setup consisted of the master console and three to four separate arms. The performance of the procedure, the size, position, and the distance between the ports, the external and internal collisions, and complications of the procedures were recorded and analyzed. Results: We were able to perform all surgical procedures as planned. We encountered neither surgical nor robot-associated complications in the live model. Whereas all abdominal procedures could be performed successfully under general anesthesia, one piglet was euthanized early before the thoracic interventions, likely due to pulmonary inflammatory response. Technical limitations were based on the size of the camera (10 mm) being too large and the minimal insertion depth of the instruments for calibration of the fulcrum point. Conclusions: Robotic surgery on newborns and infants appears technically feasible with the Versius® system. Software adjustments for fulcrum point calibration need to be implemented by the manufacturer as a result of our study. To further evaluate the Versius® system, prospective trials are needed, comparing it to open and laparoscopic surgery as well as to other robotic systems.
- 21 April 2022
- Published by Georg Thieme Verlag KG in AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie
- Vol. 57 (04) , 246-262
Zielgerichtetes hämodynamisches Monitoring im OP: Wozu und womit?
Das zielgerichtete hämodynamische Monitoring und die Balance zwischen adäquater Flüssigkeits- und Volumentherapie und der Applikation vasoaktiver bzw. inotroper Medikamente sind die Grundelemente der modernen perioperativen Therapie [1] [2] [3]. Der Artikel soll einen Überblick zum derzeitigen Vorgehen und einen Ausblick auf die Zukunft des hämodynamischen Monitorings geben. Die aktuellen Möglichkeiten werden an einem Fallbeispiel diskutiert. Goal directed hemodynamic monitoring and the balance in goal directed therapy between adequate fluid/volume therapy and the application of vasoactive or inotropic drugs are the basic elements of modern perioperative therapy. Surgical procedures should be accompanied by as few side effects and complications as possible. Nevertheless, the number of postoperative complications remains surprisingly high, despite of the modern surgical procedures. Anticipation of potential complications in the perioperative period and their rapid treatment build a core competence of anesthesiological action. Thus, it is clear that anesthesia plays a central role in this balancing act. This article aims to provide an overview of the application of the currently available perioperative goal directed hemodynamic monitoring. The current possibilities are discussed by using a case example and an outlook on the future of hemodynamic monitoring is given. Publication Date: 21 April 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 21 April 2022
- Published by Georg Thieme Verlag KG in AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie
- Vol. 57 (04) , 246-262
Zielgerichtetes hämodynamisches Monitoring im OP: Wozu und womit?
Das zielgerichtete hämodynamische Monitoring und die Balance zwischen adäquater Flüssigkeits- und Volumentherapie und der Applikation vasoaktiver bzw. inotroper Medikamente sind die Grundelemente der modernen perioperativen Therapie [1] [2] [3]. Der Artikel soll einen Überblick zum derzeitigen Vorgehen und einen Ausblick auf die Zukunft des hämodynamischen Monitorings geben. Die aktuellen Möglichkeiten werden an einem Fallbeispiel diskutiert. Goal directed hemodynamic monitoring and the balance in goal directed therapy between adequate fluid/volume therapy and the application of vasoactive or inotropic drugs are the basic elements of modern perioperative therapy. Surgical procedures should be accompanied by as few side effects and complications as possible. Nevertheless, the number of postoperative complications remains surprisingly high, despite of the modern surgical procedures. Anticipation of potential complications in the perioperative period and their rapid treatment build a core competence of anesthesiological action. Thus, it is clear that anesthesia plays a central role in this balancing act. This article aims to provide an overview of the application of the currently available perioperative goal directed hemodynamic monitoring. The current possibilities are discussed by using a case example and an outlook on the future of hemodynamic monitoring is given. Publication Date: 21 April 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 28 March 2022
- Published by Springer Nature in BMC Anesthesiology
- Vol. 22 (1) , 1-12
Comparison of oscillometric, non-invasive and invasive arterial pressure monitoring in patients undergoing laparoscopic bariatric surgery – a secondary analysis of a prospective observational study
Background: Oscillometric, non-invasive blood pressure measurement (NIBP) is the first choice of blood pressure monitoring in the majority of low and moderate risk surgeries. In patients with morbid obesity, however, it is subject to several limitations. The aim was to compare arterial pressure monitoring by NIBP and a non-invasive finger-cuff technology (Nexfin®) with the gold-standard invasive arterial pressure (IAP). Methods: In this secondary analysis of a prospective observational, single centre cohort study, systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP) were measured at 16 defined perioperative time points including posture changes, fluid bolus administration and pneumoperitoneum (PP) in patients undergoing laparoscopic bariatric surgery. Absolute arterial pressures by NIBP, Nexfin® and IAP were compared using correlation and Bland Altman analyses. Interchangeability was defined by a mean difference ≤ 5 mmHg (SD ≤8 mmHg). Percentage error (PE) was calculated as an additional statistical estimate. For hemodynamic trending, concordance rates were analysed according to the Critchley criterion. Results: Sixty patients (mean body mass index of 49.2 kg/m2) were enrolled and data from 56 finally analysed. Pooled blood pressure values of all time points showed a significant positive correlation for both NIPB and Nexfin® versus IAP. Pooled PE for NIBP versus IAP was 37% (SAP), 35% (DAP) and 30% (MAP), for Nexfin versus IAP 23% (SAP), 26% (DAP) and 22% (MAP). Correlation of MAP was best and PE lowest before induction of anesthesia for NIBP versus IAP (r = 0.72; PE 24%) and after intraoperative fluid bolus administration for Nexfin® versus IAP (r = 0.88; PE: 17.2%). Concordance of MAP trending was 90% (SAP 85%, DAP 89%) for NIBP and 91% (SAP 90%, DAP 86%) for Nexfin®. MAP trending was best during intraoperative ATP positioning for NIBP (97%) and at induction of anesthesia for Nexfin® (97%). Conclusion: As compared with IAP, interchangeability of absolute pressure values could neither be shown for NIBP nor Nexfin®, however, NIBP showed poorer overall correlation and precision. Overall trending ability was generally high with Nexfin® surpassing NIBP. Nexfin® may likely render individualized decision-making in the management of different hemodynamic stresses during laparoscopic bariatric surgery, particularly where NIBP cannot be reliably established. Trial registration: The non-interventional, observational study was registered retrospectively at (NCT03184285) on June 12, 2017.
- 28 March 2022
- Published by Springer Nature in BMC Anesthesiology
- Vol. 22 (1) , 1-12
Open AccessComparison of oscillometric, non-invasive and invasive arterial pressure monitoring in patients undergoing laparoscopic bariatric surgery – a secondary analysis of a prospective observational study
Background: Oscillometric, non-invasive blood pressure measurement (NIBP) is the first choice of blood pressure monitoring in the majority of low and moderate risk surgeries. In patients with morbid obesity, however, it is subject to several limitations. The aim was to compare arterial pressure monitoring by NIBP and a non-invasive finger-cuff technology (Nexfin®) with the gold-standard invasive arterial pressure (IAP). Methods: In this secondary analysis of a prospective observational, single centre cohort study, systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP) were measured at 16 defined perioperative time points including posture changes, fluid bolus administration and pneumoperitoneum (PP) in patients undergoing laparoscopic bariatric surgery. Absolute arterial pressures by NIBP, Nexfin® and IAP were compared using correlation and Bland Altman analyses. Interchangeability was defined by a mean difference ≤ 5 mmHg (SD ≤8 mmHg). Percentage error (PE) was calculated as an additional statistical estimate. For hemodynamic trending, concordance rates were analysed according to the Critchley criterion. Results: Sixty patients (mean body mass index of 49.2 kg/m2) were enrolled and data from 56 finally analysed. Pooled blood pressure values of all time points showed a significant positive correlation for both NIPB and Nexfin® versus IAP. Pooled PE for NIBP versus IAP was 37% (SAP), 35% (DAP) and 30% (MAP), for Nexfin versus IAP 23% (SAP), 26% (DAP) and 22% (MAP). Correlation of MAP was best and PE lowest before induction of anesthesia for NIBP versus IAP (r = 0.72; PE 24%) and after intraoperative fluid bolus administration for Nexfin® versus IAP (r = 0.88; PE: 17.2%). Concordance of MAP trending was 90% (SAP 85%, DAP 89%) for NIBP and 91% (SAP 90%, DAP 86%) for Nexfin®. MAP trending was best during intraoperative ATP positioning for NIBP (97%) and at induction of anesthesia for Nexfin® (97%). Conclusion: As compared with IAP, interchangeability of absolute pressure values could neither be shown for NIBP nor Nexfin®, however, NIBP showed poorer overall correlation and precision. Overall trending ability was generally high with Nexfin® surpassing NIBP. Nexfin® may likely render individualized decision-making in the management of different hemodynamic stresses during laparoscopic bariatric surgery, particularly where NIBP cannot be reliably established. Trial registration: The non-interventional, observational study was registered retrospectively at (NCT03184285) on June 12, 2017.