MVMiroslav Vacek

Miroslav Vacek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Miroslav Vacek has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Vít Křivý

    VŠB-TU Ostrava, Faculty of Civil Engineering, Ludvíka Podéště 1875, 708 33 Ostrava, Czech Republic

    5 shared publications
  • Lucie Malíková

    Brno University of Technology, Faculty of Civil Engineering, Institute of Structural Mechanics Veveří 331/95, 602 00 Brno, Czech Republic and Czech Academy of Sciences; Institute of Physics of Materials, v. v. i., Žižkova 22, 616 00 Brno, Czech Republic

    3 shared publications
  • Mohammad Sami Al Khazali

    Brno University of Technology, Faculty of Civil Engineering, Institute of Structural Mechanics, Veveří 331/95, 602 00 Brno, Czech Republic

    3 shared publications
  • Stanislav Seitl

    Brno University of Technology, Faculty of Civil Engineering, Institute of Structural Mechanics Veveří 331/95, 602 00 Brno, Czech Republic and Czech Academy of Sciences; Institute of Physics of Materials, v. v. i., Žižkova 22, 616 00 Brno, Czech Republic

    3 shared publications
  • Dziuba Szymon

    Faculty of Mechanical Engineering, Wroclaw University of Science and Technology , Łukasiewicza 5/7, 50-370 Wrocław , Poland

    2 shared publications
  • Grzegorz Lesiuk

    Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland

    2 shared publications

Latest Publications

  • Open Access

    Microscopic Evaluation of Fatigue Damage Development in Welded S460 Steel Specimens after Accelerated Corrosion Exposure

    by Mohammad Sami Al Khazali, Lucie Maliková, Kamila Kozáková, Grzegorz Lesiuk, Dziuba Szymon, Miroslav Vacek, Stanislav Seitl

    The present study investigates the development of fatigue damage in welded S460 high-strength steel specimens subjected to different corrosion exposure conditions. Four surface conditions were considered: an uncorroded reference condition, 3-day exposure, 6-day exposure and combined 6+3-day exposure, hereafter referred to as 3D, 6D and 6+3D/9D, respectively. Fatigue tests were performed at a stress ratio of . Microscopic observations were carried out before and after fatigue testing using an Olympus DSX1000 digital microscope to evaluate surface degradation, crack/fracture localization and damage development in the welded region. The uncorroded reference condition showed fatigue damage that was predominantly localized in the welded region, thereby confirming the dominant role of weld geometry and the local notch effect. As the level of corrosion exposure increased, the surface condition changed progressively. The 3D condition exhibited limited early degradation, the 6D condition revealed more distinct surface defects, and the 6+3D/9D condition showed the most pronounced corrosion-product regions and pit-like surface damage. The fatigue results indicated a non-monotonic influence of corrosion exposure. The apparent improvement observed for the 3D and 6D conditions may be related to local modification of the weld-toe surface condition and partial mitigation of the original weld-induced notch effect. After fatigue testing, all representative specimens showed crack/fracture development near the weld toe and heat-affected zone (HAZ) vicinity. The findings indicate that fatigue damage was governed by the combined effect of weld-toe geometry, the visually distinguishable HAZ vicinity and corrosion-induced surface degradation.

  • Open Access

    Microscopic Evaluation of Fatigue Damage Development in Welded S460 Steel Specimens after Accelerated Corrosion Exposure

    by Mohammad Sami Al Khazali, Lucie Maliková, Kamila Kozáková, Grzegorz Lesiuk, Dziuba Szymon, Miroslav Vacek, Stanislav Seitl

    The present study investigates the development of fatigue damage in welded S460 high-strength steel specimens subjected to different corrosion exposure conditions. Four surface conditions were considered: an uncorroded reference condition, 3-day exposure, 6-day exposure and combined 6+3-day exposure, hereafter referred to as 3D, 6D and 6+3D/9D, respectively. Fatigue tests were performed at a stress ratio of . Microscopic observations were carried out before and after fatigue testing using an Olympus DSX1000 digital microscope to evaluate surface degradation, crack/fracture localization and damage development in the welded region.The uncorroded reference condition showed fatigue damage that was predominantly localized in the welded region, thereby confirming the dominant role of weld geometry and the local notch effect. As the level of corrosion exposure increased, the surface condition changed progressively. The 3D condition exhibited limited early degradation, the 6D condition revealed more distinct surface defects, and the 6+3D/9D condition showed the most pronounced corrosion-product regions and pit-like surface damage. The fatigue results indicated a non-monotonic influence of corrosion exposure. The apparent improvement observed for the 3D and 6D conditions may be related to local modification of the weld-toe surface condition and partial mitigation of the original weld-induced notch effect.After fatigue testing, all representative specimens showed crack/fracture development near the weld toe and heat-affected zone (HAZ) vicinity. The findings indicate that fatigue damage was governed by the combined effect of weld-toe geometry, the visually distinguishable HAZ vicinity and corrosion-induced surface degradation.

  • Open Access

    Effect of Corrosion Damage on the Fatigue Behavior of S460NL High-Strength Steel under Cyclic Loading

    by Stanislav Seitl, Mohammad Sami Al Khazali, Lucie Malíková, Vít KřIvý, Miroslav Vacek

    The present study investigates the influence of corrosion exposure on the fatigue behavior of S460NL high-strength structural steel, a material that is frequently utilized in offshore and civil engineering structures. Accelerated corrosion was simulated under controlled laboratory conditions for exposure periods of 3 days, 6 days, and 6 + 3 days, in addition to specimens subjected to natural atmospheric corrosion. To this end, fatigue tests were performed to obtain S–N curves, and the results were evaluated using Basquin's law and the probabilistic Castillo–Canteli model. The findings indicate that corrosion has a substantial impact on fatigue resistance. The endurance limit exhibited a decline from 214 MPa for the reference specimens to 176 MPa following three days of corrosion, 135 MPa after six days, and approximately 92 MPa after combined corrosion exposure, signifying a reduction of up to 57%. Fractographic observations revealed that corrosion pits act as stress concentrators, thereby promoting early crack initiation. A discernible correlation was identified between corrosion mass loss and normalized endurance limit. These findings highlight the importance of considering corrosion effects in fatigue life assessment and structural design of high-strength steel components.


  • Open Access

    Testing the Corrosion Rate of Prestressed Concrete Beams Under Variable Temperature and Humidity Conditions

    by Zofia Szweda, Michał Krak, Szymon Czarniak, Artur Skórkowski, Jacek Małek, Jakub Sikorski, Jakub Trojan, Petr Konečný, Miroslav Vacek, Jakub Marek

    To date, many studies can be found in the literature attempting to explain the effects of temperature and humidity on the rate of corrosion processes. However, it is difficult to analyze the results of these studies and draw unambiguous conclusions due to the different test conditions as well as different electrochemical test methods for corrosion rates. Most of these studies concern concrete reinforced with ordinary steel. However, there is a lack of research and analysis conducted on prestressed elements. The purpose of this study was to evaluate the effect of temperature and humidity changes on the development of corrosion processes in prestressed concrete beams. Tests were performed both under conditions of increasing temperature and humidity, which were reproduced in a climatic chamber, as well as in an environment exposed to chloride ions. The process of migration of chloride ions into the concrete was accelerated by the application of an electric field. In addition, selected beams were subjected to prolonged loading to sustain the induced scratching. Corrosion rate tests were carried out using the non-destructive linear polarization method (LPR). Strength tests of the beams were also carried out, as well as displacement and deformation measurements using the Aramis system’s digital image correlation technique. The beams without chloride addition had a fairly stable low level of corrosion current density throughout the test period, indicating the passive state of the reinforcement, regardless of the environment in which they were placed and the additional loading. In an environment with a humidity of 30% and a temperature of 20 °C, the corrosion current density increment was much faster than for beams with chloride additives in an environment with a humidity of 90% and a temperature of 30 °C. A smaller increase in corrosion current density could be observed in beams that were scratched, compared to non-scratched beams. The results of the strength tests indicated that in beams subjected to accelerated migration of chloride ions, the deflection at scratching was significantly lower than in beams without chloride addition. Also in these beams, milder strains were registered on the surface of the elements at the time of scratching.


  • Open Access

    Research of the Existing Post - tensioned Roof Trusses and their Reliability

    by Petr Mynarcik, Vladislav Bures, Marek Johanides, Pavel Dobes, David Mikolasek, Miroslav Vacek, Martin Patrman

    The issue of insufficient reliability and, in some cases, the failure of post - tensioned bridge structures, footbridges, and roof trusses, particularly in industrial halls, is one of the current and serious problems of the construction industry in the Czech Republic. The most well - known failures of these structures include the collapse of the Morandi Bridge near Genoa, Italy, in August 2018, and the collapse of the Troja footbridge in Prague in December 2017. Less known are the failures of post - tensioned truss roof structures that occurred in the Czech Republic and Slovakia. Especially in the Czech Republic, there were failures in Tachov (2010 and 2018), Sluknov (December 2023), and Karlovy Vary (March 2024). A common feature of all these failures was the corrosion of the prestressing reinforcement in inadequately grouted cable ducts. Roof structures of this type have been used in more than 100 buildings that are still in operation in the Czech Republic. In response to this situation, the company Rada Building s.r.o., in cooperation with academic institutions, developed a method to reinforce trusses threatened by corrosion using an external steel structure. The company carries out the reinforcement work during normal operation in the hall below the trusses. Research on post - tensioned truss structures and the possibilities of their static securing is being conducted in cooperation with the Faculty of Civil Engineering at VSB – Technical University of Ostrava, the Faculty of Art and Architecture at the Technical University of Liberec, and the company Rada Building, s.r.o. The ambition of the research is to analyze the condition of as many trusses as possible embedded in buildings in the Czech Republic and Slovakia using building structure diagnostic methods and to evaluate these surveys. Furthermore, the research aims to verify the actual behavior of such structures through tests on real trusses taken from demolished buildings. VSB – TU Ostrava has several trusses available, and load tests are currently being carried out on them. An important and final part of the research is to find the optimal diagnostic method that would improve the ability to predict the risk of roof failures in operational buildings and to optimize the methods for securing these structures to ensure full static reliability with the lowest possible costs and minimal impact on the building.

  • Open Access

    Determination of the Chloride Ion Deposition by the Bresle Method

    by Miroslav Vacek, Vít Křivý, Barbora Křistková

    In corrosion science, accurate determination of chloride ion deposition rates is critical to mitigating the environmental impact on structures. Traditional methods, such as the wet candle and dry plate methods (ISO 9225), are often inaccurate in capturing localized conditions and are also time-consuming and costly. The Bresle method, which measures soluble salts directly on metal surfaces, offers a more targeted approach. This article examines the Bresle method as an alternative for determining average monthly chloride ion deposition rates, including a regression analysis comparing the Bresle method with the wet candle method, and examines the long-term salinity of exposed surfaces in comparison with the additive approach to surface salinity. This paper hypothesizes that the Bresle method can be used as an alternative to the wet candle method. Linear regression analysis shows a strong correlation in chloride ion deposition rates compared to those measured by the wet candle method. However, cumulative measurements using long-term exposed coupons are unreliable due to inconsistent trends.


  • Open Access

    CHANGES IN DEVELOPMENT OF PROTECTIVE PATINA ON WEATHERING STEEL

    by Kateřina KREISLOVÁ, Markéta Vlachová, Anna Píšková, Pavlína Fialová, Petr Pokorný, Vít Křivý, Miroslav Vacek

  • Open Access

    Experimental Measurement of Deposition Chloride Ions in the Vicinity of Road Cut

    by Miroslav Vacek, Vít Křivý, Kateřina Kreislová, Markéta Vlachová, Monika Kubzová

    Chloride ions are nowadays the main cause of the degradation of steel and reinforce concrete construction in the vicinity of the road. On the other hand, chloride ions, usually in the form of de-icing salts or brine, are very important for safe winter traffic on the roads. This creates a slightly schizophrenic situation where it is necessary to ensure safe traffic in the winter period and at the same time to affect the service life of the structure as little as possible. The effect of the roadway on chloride deposition is a long-studied, but still imprecisely understood, part of the effect of chloride ions on structures in the vicinity of the roadway. This paper discusses the experimental measurement of chloride deposition in the vicinity of the I/11 road in the Czech Republic by dry plate method, wet candle method and corrosion coupons. Statistical analysis of correlation and regression is performed on the results of measurements by wet candle and horizontal dry plate methods. The methods are interdependent. A detailed analysis of the surface and chemical properties of the corrosion products is performed on the corrosion coupons. Using the corrosion loss, the environmental category C2 is determined. Observation of the microclimate in the vicinity of the roads gives to engineers a basis for the correct design of structures around the roads. The conclusions of the experimental measurements are intended to help engineers to design a structure that is safe, serviceable and sufficiently resistant to chloride ions within its service life


  • Open Access

    Corrosion Damage to Joints of Lattice Towers Designed from Weathering Steels

    by Vít Křivý, Zdeněk Vašek, Miroslav Vacek, Lucie Mynarzová

    The article dealt with the load-bearing capacity and durability of power line lattice towers designed from weathering steel. Attention was paid in particular to the bolted lap joints. The article evaluates the static and corrosion performance of bolted lap joints in long-term operating towers, and also presents and evaluates design measures that can be applied in the design of new lattice towers, or in the reconstruction of already operating structures. Power line lattice towers are the most extensive realization of weathering steel in the Czech Republic. On the basis of the inspections carried out to evaluate the working life of the transmission towers in operation, it can be stated that a sufficiently protective layer of corrosion products generally developed on the bearing elements of the transmission towers. However, the development of crevice corrosion at the bolted joints of the leg members is a significant problem. In this paper, the corrosion damage of bolted joints was evaluated considering two basic aspects: (1) the influence of crevice corrosion on the bearing capacity of the bolted joint was evaluated, using experimental testing and based on analytical and numerical calculations; (2) appropriate design measures applicable to the rehabilitation of developed crevice corrosion of in-service structures, or the elimination of crevice corrosion in newly designed lattice towers, was evaluated. Calculation analyses and destructive tests of bolted joints show that the development of corrosion products in the crevice does not have a significant effect on the bearing capacity of the joint, provided that there is no significant corrosion weakening of the structural elements, and bolts of class 8.8 or 10.9 are used. The results of the long-term experimental programme, and the experience from the rehabilitations carried out, show that, thanks to appropriate structural measures, specified in detail in the paper, the long-term reliable behaviour of the lattice towers structures is ensured.