Zi Qian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zi Qian has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Leila Pasandi3 shared publications
- Wai Lok Woo
School of Computer Science, Northumbria University, Newcastle upon Tyne NE1 8ST, UK
2 shared publications - Deo Prasad
School of Built Environment, University of New South Wales, Sydney, NSW 2052, Australia
1 shared publication - Ryan Hepple
School of Built Environment, Engineering and Computing, Leeds Beckett University, Leeds LS1 3HE, UK
1 shared publication - Sanober Khattak
Institute for Sustainable Futures, De Montfort University, Leicester LE1 9BH, UK
1 shared publication - Siliang Yang
Mott MacDonald, Leeds LS12 1BE, UK
1 shared publication
Latest Publications
- Open Access
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Physics-Informed Benchmarking of Multi-horizon Building Energy Forecasting Models to 2050: TFT, LSTM, XGBoost, and TimesFM under Urban Microclimate Forcing
Accurate long-horizon building energy forecasting is essential for climate-resilient retrofit planning and intelligent building operation. This study presents a physics-informed digital workflow that integrates urban microclimate forcing into AI-based prediction of hourly building energy demand to 2050. The framework combines urbanised weather generation, high-resolution microclimate simulation, EnergyPlus modelling, and multi-horizon forecasting within an automated workflow. Paired baseline and microclimate-informed datasets were constructed and evaluated using Temporal Fusion Transformer (TFT), LSTM, XGBoost, and TimesFM-XReg models under identical validation conditions. Results show that microclimate-informed training reduced RMSE by 44.2% overall and 41.8% during peak-hours, with TFT achieving the most robust performance across all regimes. The findings demonstrate that integrating realistic urban boundary conditions into AI workflows improves forecasting reliability more effectively than increasing model complexity alone, highlighting the importance of physics-informed digital frameworks for future intelligent and climate-responsive buildings.
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPhysics-Informed Benchmarking of Multi-horizon Building Energy Forecasting Models to 2050: TFT, LSTM, XGBoost, and TimesFM under Urban Microclimate Forcing
Accurate long-horizon building energy forecasting is essential for climate-resilient retrofit planning and intelligent building operation. This study presents a physics-informed digital workflow that integrates urban microclimate forcing into AI-based prediction of hourly building energy demand to 2050. The framework combines urbanised weather generation, high-resolution microclimate simulation, EnergyPlus modelling, and multi-horizon forecasting within an automated workflow. Paired baseline and microclimate-informed datasets were constructed and evaluated using Temporal Fusion Transformer (TFT), LSTM, XGBoost, and TimesFM-XReg models under identical validation conditions. Results show that microclimate-informed training reduced RMSE by 44.2% overall and 41.8% during peak-hours, with TFT achieving the most robust performance across all regimes. The findings demonstrate that integrating realistic urban boundary conditions into AI workflows improves forecasting reliability more effectively than increasing model complexity alone, highlighting the importance of physics-informed digital frameworks for future intelligent and climate-responsive buildings.
- Open Access
- 20 May 2026
- Published by Elsevier in SSRN Electronic Journal
Physics-Informed Benchmarking of Multi-horizon Building Energy Forecasting Models to 2050: TFT, LSTM, XGBoost, and TimesFM under Urban Microclimate Forcing
Accurate long-horizon forecasting of building energy demand is critical for retrofit planning, grid resilience, and climate adaptation. However, most forecasting approaches rely on standard weather inputs that neglect urban microclimate effects, introducing systematic errors, particularly under peak and extreme conditions. In dense urban environments, local boundary conditions can deviate substantially from reference-station data due to urban heat island effects, radiative exchange, and altered airflow.This study develops a physics-informed forecasting framework that integrates urban microclimate forcing into long-horizon prediction of hourly total building energy demand to 2050. A hybrid modelling strategy is implemented, combining annual urbanised weather generation with high-resolution microclimate simulations applied to representative periods. These conditions are incorporated into building energy simulations to generate paired datasets (baseline and microclimate-informed) with identical structure, enabling controlled evaluation of forecasting performance.Prediction is formulated as a 24-hour multi-horizon task and evaluated using the Temporal Fusion Transformer (TFT), benchmarked against LSTM, XGBoost, and TimesFM-XReg under shared validation conditions. Results show that microclimate-informed training reduces root mean square error by 44.2% overall, 41.8% during peak-hours, and 24.4% under extreme-load conditions, with improvements sustained across the full forecast horizon. Among the models, TFT achieves the most consistent performance across all regimes.The findings demonstrate that improving boundary-condition realism has a greater impact on forecasting accuracy than increasing model complexity. Incorporating urban microclimate effects is therefore essential for reliable long-term energy prediction and robust assessment of future building performance under climate change.
- 20 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPhysics-Informed Benchmarking of Multi-horizon Building Energy Forecasting Models to 2050: TFT, LSTM, XGBoost, and TimesFM under Urban Microclimate Forcing
Accurate long-horizon forecasting of building energy demand is critical for retrofit planning, grid resilience, and climate adaptation. However, most forecasting approaches rely on standard weather inputs that neglect urban microclimate effects, introducing systematic errors, particularly under peak and extreme conditions. In dense urban environments, local boundary conditions can deviate substantially from reference-station data due to urban heat island effects, radiative exchange, and altered airflow.This study develops a physics-informed forecasting framework that integrates urban microclimate forcing into long-horizon prediction of hourly total building energy demand to 2050. A hybrid modelling strategy is implemented, combining annual urbanised weather generation with high-resolution microclimate simulations applied to representative periods. These conditions are incorporated into building energy simulations to generate paired datasets (baseline and microclimate-informed) with identical structure, enabling controlled evaluation of forecasting performance.Prediction is formulated as a 24-hour multi-horizon task and evaluated using the Temporal Fusion Transformer (TFT), benchmarked against LSTM, XGBoost, and TimesFM-XReg under shared validation conditions. Results show that microclimate-informed training reduces root mean square error by 44.2% overall, 41.8% during peak-hours, and 24.4% under extreme-load conditions, with improvements sustained across the full forecast horizon. Among the models, TFT achieves the most consistent performance across all regimes.The findings demonstrate that improving boundary-condition realism has a greater impact on forecasting accuracy than increasing model complexity. Incorporating urban microclimate effects is therefore essential for reliable long-term energy prediction and robust assessment of future building performance under climate change.
- Open Access
- 4 September 2025
- Published by Elsevier in Building and Environment
- Vol. 285
Quantifying urban microclimate feedback on building energy use using a coupled simulation workflow
- 4 September 2025
- Published by Elsevier in Building and Environment
- Vol. 285
Open AccessQuantifying urban microclimate feedback on building energy use using a coupled simulation workflow
- Open Access
Comparative Analysis of CIBSE Admittance and ASHRAE Radiant Time Series Cooling Load Models
Due to the impacts of carbon emissions on climate change and the expected dramatic increase in global cooling demand by 2050, it is of a paramount importance that the required energy to cool buildings is accurately predicted. This ensures that equipment is appropriately sized, which ultimately reduces energy consumption and global carbon emissions. CIBSE and ASHRAE standards are both widely adopted for cooling load predictions, but they adopt different calculation methods, with CIBSE adopting admittance and ASHRAE adopting radiant time series (RTS), which produce significantly different results in cooling load. This study comparatively and qualitatively evaluates the CIBSE admittance and ASHRAE RTS cooling load models by analysing their structures and key input parameters for a mock-up building to identify inconsistencies between the two methods. There were flaws within both models that resulted in the CIBSE method underpredicting the cooling load, whereas the ASHRAE method typically overpredicting it. This resulted in a maximal average difference of over 60%. The substantial predicted cooling load difference was mainly caused by the ASHRAE RTS model, which was highly receptive to solar gains, and it consequently led to overprediction in cooling load when compared to the CIBSE admittance model.
Open AccessComparative Analysis of CIBSE Admittance and ASHRAE Radiant Time Series Cooling Load Models
Due to the impacts of carbon emissions on climate change and the expected dramatic increase in global cooling demand by 2050, it is of a paramount importance that the required energy to cool buildings is accurately predicted. This ensures that equipment is appropriately sized, which ultimately reduces energy consumption and global carbon emissions. CIBSE and ASHRAE standards are both widely adopted for cooling load predictions, but they adopt different calculation methods, with CIBSE adopting admittance and ASHRAE adopting radiant time series (RTS), which produce significantly different results in cooling load. This study comparatively and qualitatively evaluates the CIBSE admittance and ASHRAE RTS cooling load models by analysing their structures and key input parameters for a mock-up building to identify inconsistencies between the two methods. There were flaws within both models that resulted in the CIBSE method underpredicting the cooling load, whereas the ASHRAE method typically overpredicting it. This resulted in a maximal average difference of over 60%. The substantial predicted cooling load difference was mainly caused by the ASHRAE RTS model, which was highly receptive to solar gains, and it consequently led to overprediction in cooling load when compared to the CIBSE admittance model.