MSMeng Song

Meng Song

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Meng Song has a total of 142 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • International Round-Robin Test of Critical Current of Superconducting Cable Sample

    by T. Matsushita, M. Kiuchi, T. Masuda, S. Mukoyama, K. Funaki, J. Cho, J. Lu, M. J. Raine, L. Quéval, F. Trillaud, et al.

    Ten institutes from six countries participated in an international round-robin test to evaluate the critical current of a superconducting power cable made of Bi-2223 tapes. The cable design featured a two-layer inner core conductor and a single-layer outer shield conductor. The shield layer measured approximately 40 mm in diameter, and the cable length was 2.0 m. To eliminate the influence of resistive voltage drops from current transfer, voltage taps for measurement were positioned at a sufficient distance from the current terminals. The critical current was determined using the resistive method with the electric field criterion of 1.0 ${\rm{\mu V}}/\text{cm}$ . In addition, the $n$ -value, an optional parameter reflecting the current–voltage ( $I$ – $V$ ) characteristics, was extracted from the $I$ – $V$ curve within an electric field range of 0.1–1.0 ${\rm{\mu V}}/\text{cm}$ . A detailed uncertainty analysis was conducted for both the critical current and the $n$ -value. Finally, this article discusses the potential for standardization of the employed resistive measurement method.


  • AC Loss Calculation on a 10 MJ/5 MW HTS SMES with Hybrid Winding Structure

    by Feiyang Long, Ying Xu, Li Ren, Meng Song, Li Li, Haipeng Zhang, Jiajie Wu

    Larger capacity has become a trend in the development of high-temperature superconducting magnetic energy storage system (HTS-SMES). A 10 MJ/5 MW HTS-SMES is under construction, and the cost of the conductor can be effectively reduced by introducing a hybrid winding structure with low-cost MgB2 cable in the low-field region. In this paper, the AC losses of a 10 MJ/5 MW SMES magnet under different working conditions are investigated and it provides a reference for the design of the cooling system and control strategy.


  • Mechanical Performance Tests of Customized CORC Cable

    by Yajun Xia, Meng Song, Changbin Wang, Lingfeng Lai

    High temperature superconducting (HTS) CORC cable, wound from ReBCO coated superconducting tapes, have good mechanical performance, flexibility, high current carrying capacity and isotropy. Therefore, CORC cables have important potential in magnets and power applications. In application, the cable will inevitably be subjected to mechanical and electromagnetic stresses. And during the operation cables will probably experience electromagnetic and thermal cycles. To investigate these effects on the performance of CORC cables, the changes in critical current under different bending radii, transverse pressure, and electromagnetic and thermal cycling were tested in liquid nitrogen. The results show that the soft-core sample degraded when the pressure achieved 1.2 kN/m, while the hard-core cable shows a reduction in critical current at a pressure of 7.7 kN/m. The bending measurement on the CORC cable with hard core shows that the critical current degradation occurs when the bending radius is below 45 mm. There is a decrease in critical current in a 3-turn coil wound with a 1.2-meter-long CORC cable, which may be due to mechanical damage incurred during the winding process. The electromagnetic and thermal cycle experiments on the CORC cable made coil caused reversible and irreversible critical current degradation. After a series of cycles, the Ic tended to be stabilized at 90% of original critical current of the CORC cable.


  • Impacts of Superconducting Fault Current Limiters on Undervoltage Protection for the Distribution Network

    by Meng Song, Li Li, Qi Wu, Chao Li

    The superconducting fault current limiter (SFCL) is considered as an effective current-limiting option due to its superconducting and quench characteristics. While limiting the short-circuit currents in the distribution network, the SFCLs do not bring extra power losses to the distribution network likewise. This work analyzes the impacts of SFCLs on the undervoltage protection in distribution network and proposes the improvement coordination scheme for the SFCL and the protection. A simulation model of 10 kV distribution network with SFCL is constructed through PSCAD simulation platform to verify the effectiveness of the proposed improved scheme for the undervoltage protection.


  • Optimized Design and Electromagnetic-Thermal- Mechanical Analysis of a Toroidal D-Shaped Superconducting Magnet in 5 MW LIQHY-SMES System

    by Zhixing Yang, Li Ren, Ying Xu, Jing Shi, Yifeng Qiu, Pu Duan, Jiakun Fang, Chuang Wang, Meng Song, Li Li

    Compared with other energy storage devices, LIQHY-SMES (the combination of liquid hydrogen and superconducting magnetic energy storage) systems have obvious advantages in conversion efficiency, response speed, energy storage capacity and have a bright prospect in power systems. Superconducting magnets are the electromagnetic energy storage units and the core components of LIQHY-SMES systems. In this paper, the electromagnetic optimized design of a toroidal D-shaped magnet applied in the 5 MW LIQHY-SMES system is completed by COMSOL and MA-TLAB co-simulation. In addition, the basic cryogenic system and quench protection system of the magnet are studied. Aimed at the difficulty of modeling and calculating the multi-physics field behaviors for toroidal D-shaped SMES magnets due to their complex structure, a method of electromagnetic-thermal-mechanical decoupling analysis is proposed, and the magnetic field distribution, AC loss, temperature rise and stress distribution during the operation of the designed magnet are studied. By this means, the stability of the designed magnet is verified, which provides a reference for toroidal D-shaped magnets to the multi-physics behaviors analyze.


  • 3-D Modeling of AC Loss in D-Shaped HTS Coils Using $H$ and $T$-$A$ Formulation-Based Finite Element Methods

    by Wenxu Liu, Shaotao Dai, Tao Ma, Yangyang Shi, Meng Song, Li Li

    The D -shaped coil is employed in the design of the hybrid toroidal magnet for 10 MJ high-temperature superconducting magnetic energy storage (HTS-SMES) to mitigate the huge bending moment on the coil. During the power compensation process of the SMES system, the time-varying currents induce AC losses within the magnet, leading to heating and temperature rise. Excessive temperature rise can result in the magnet experiencing a quench or even damage. Therefore, accurately calculating the AC losses generated by the magnet for HTS-SMES is crucial for the stable operation of the system. Generally, 2D models cannot accurately simulate the complex geometric shapes of superconducting coils with non-axisymmetric properties. This paper applies the \boldmath $H$ -formulation and $T$ - $A$ formulation and their homogeneous method to the 3D finite element method (FEM) models of a D -shaped double-pancake coil (DPC). The effectiveness of the established 3D FEM models has been verified through AC loss measurement experiments on a D -shaped HTS DPC at 77 K temperature. The application strategies of $T$ - $A$ full, $T$ - $A$ homogenization, and $H$ homogenization in the 3D FEM models have been comprehensively compared under different sizes of D -shaped HTS DPCs. Subsequently, the distribution characteristics of AC losses in a D -shaped DPC have been analyzed. The research findings reveal that the distribution of AC losses exhibits non-uniformity along the arc direction of the coil. The difference between the maximum and minimum values in this coil is approximately 15.1% in the \boldmath $H$ homogeneous model and 14.0% in the $T$ - $A$ homogeneous model. This work holds significant guidance for the computational assessment of AC losses in the hybrid toroidal magnet for 10 MJ HTS-SMES.


  • Analytical Calculation of Mutual Inductance of D-Shaped Coils Applied to High-Temperature Superconducting Magnet

    by Wenxu Liu, Shaotao Dai, Tao Ma, Yangyang Shi, Meng Song, Li Li

    D-shaped coils, which are applied to large toroidal HTS-SMES magnets, can reduce the non-uniform tension and large bending moment caused by the structure of toroidal magnets and decrease the stress of the coil section. It is vital to accurately calculate the self-inductance and mutual inductance parameters for all the turns and coils in analyzing the transient response of HTS-SMES magnets. In this paper, an analytical calculation method for calculating mutual inductance parameters between D-shaped coils is presented, to address the potential challenges of meshing and long time-consuming computations in the 3D finite element method (FEM) model. The calculation results are compared with mutual inductance obtained by the FEM. The results show that the proposed analytical method can calculate the mutual inductance of D-shaped coils quickly and effectively. Moreover, the mutual inductance of the model, which has a large width/height ratio, can also be calculated. Finally, the influences of the width and thickness of tapes and the distance between coils on the mutual inductance between D-shaped coils are studied.


  • Instantaneous AC Loss and Inductance Measurement of HTS Coil With Finite-Data-Window Least Squares

    by Feiyang Long, Ying Xu, Xin Li, Li Ren, Jing Shi, Yuejin Tang, Meng Song, Li Li

    AC loss is a critical concern for the stability of superconducting device. Various experimental methods are available for measuring AC loss in superconductors, with electrical measurement techniques being widely adopted. However, these methods only measure average loss and often disregard variations in superconductor inductance with current, which may lead to inaccuracy. This study introduces a finite-data-window least squares method to measure instantaneous AC loss in coils wound with YBCO tapes. By comparing the results with those obtained through the integral method, it is demonstrated that the proposed approach effectively measures instantaneous AC loss for coils with limited turns. Furthermore, the pattern of superconducting coil inductance in relation to current variations is examined.


  • Effects of Lamination Thickness on Recovery Characteristics of a Variable Resistance SFCL

    by Li Li, Meng Song, Qi Zhang, Bin Xiang, Zhongbin Yuan, Zhengquan Tang, Zhiyuan Liu, Yingsan Geng, Jianhua Wang

    Resistive type superconducting fault current limiter (R-SFCL) can be used to suppress the fault current with low loss in normal conditions and fast response time in fault conditions. To meet the demand of reclosing, the fast recovery is required. However, the requirements of current limiting and recovery are contradictory in superconducting tape. To meet faster recovery in a variable resistance SFCL (VR-SFCL), superconducting tape branches with different layer parameters are used in the flowing branch. The effects of the copper and SS 316L thickness on the current limiting and recovery characteristics of the VR-SFCL are investigated through experiment. Results show that with the same critical current and room temperature resistance, the flowing branch of VR-SFCL with thicker SS 316L and thinner copper can recover faster with close current limiting ratio. The results can be helpful for the superconducting tape selection in VR-SFCL.