- Open Access
- 1 September 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 15 (3) , 1484-1498
Explainable AI for harmonic fingerprinting and voltage sag diagnosis in decentralized power grids: trends, challenges and future directions
The evolution of decentralized power grids has increased the complexity of power-quality monitoring, particularly harmonic fingerprinting and voltage sag diagnosis. Artificial intelligence improves disturbance detection and classification, yet black-box models limit transparency, engineering validation, and operator trust. This review synthesizes 108 selected studies on explainable artificial intelligence (XAI) for power-system diagnostics, focusing on SHapley Additive exPlanations (SHAP), local interpretable model-agnostic explanations (LIME), attention-based interpretability, visual analytics, and physics-informed learning. The review integrates harmonic fingerprinting with voltage sag diagnosis through their shared requirements for source attribution, temporal interpretation, physical consistency, and operator-oriented explanation. Four major deployment gaps are identified: data quality, computational latency, physical grounding, and trustworthiness. Future priorities include real-time embedded XAI, physics-informed neural networks, federated learning, standardized trustworthiness metrics, and adaptive model lifecycle management. The findings indicate that reliable autonomous diagnosis requires explainability to be integrated with predictive performance, electrical-system physics, computational efficiency, and field validation. This integration provides a stronger foundation for transparent, resilient, and trustworthy diagnostic systems in decentralized power grids.
- 1 September 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 15 (3) , 1484-1498
Open AccessExplainable AI for harmonic fingerprinting and voltage sag diagnosis in decentralized power grids: trends, challenges and future directions
The evolution of decentralized power grids has increased the complexity of power-quality monitoring, particularly harmonic fingerprinting and voltage sag diagnosis. Artificial intelligence improves disturbance detection and classification, yet black-box models limit transparency, engineering validation, and operator trust. This review synthesizes 108 selected studies on explainable artificial intelligence (XAI) for power-system diagnostics, focusing on SHapley Additive exPlanations (SHAP), local interpretable model-agnostic explanations (LIME), attention-based interpretability, visual analytics, and physics-informed learning. The review integrates harmonic fingerprinting with voltage sag diagnosis through their shared requirements for source attribution, temporal interpretation, physical consistency, and operator-oriented explanation. Four major deployment gaps are identified: data quality, computational latency, physical grounding, and trustworthiness. Future priorities include real-time embedded XAI, physics-informed neural networks, federated learning, standardized trustworthiness metrics, and adaptive model lifecycle management. The findings indicate that reliable autonomous diagnosis requires explainability to be integrated with predictive performance, electrical-system physics, computational efficiency, and field validation. This integration provides a stronger foundation for transparent, resilient, and trustworthy diagnostic systems in decentralized power grids.
- Open Access
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Identification of harmonic source location in power distribution network
This paper presents the experimental set-up of identification of harmonic source location in the power distribution network using time-frequency analysis, known as S-transform (ST) at the point of common coupling (PCC). S-transform offers high frequency resolution in analyzing the low frequency component and able to represent signal parameters in time-frequency representation (TFR) such as TFR impedance (ZTFR). The proposed method is based on IEEE Std. 1459-2010, ST, and the significant relationship of spectral impedances components (ZS) that been extracted from the ZTFR, consist of the fundamental impedance (Z1) and harmonic impedance (Zh). This experiment was conducted out on an IEEE 4-bus test feeder with a harmonic producing load in numerous different scenarios. The experimental was tested and verified for three consecutive months. The findings of this study reveal that the proposed method provides 100 percent correct identification of harmonic source location.
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Open AccessIdentification of harmonic source location in power distribution network
This paper presents the experimental set-up of identification of harmonic source location in the power distribution network using time-frequency analysis, known as S-transform (ST) at the point of common coupling (PCC). S-transform offers high frequency resolution in analyzing the low frequency component and able to represent signal parameters in time-frequency representation (TFR) such as TFR impedance (ZTFR). The proposed method is based on IEEE Std. 1459-2010, ST, and the significant relationship of spectral impedances components (ZS) that been extracted from the ZTFR, consist of the fundamental impedance (Z1) and harmonic impedance (Zh). This experiment was conducted out on an IEEE 4-bus test feeder with a harmonic producing load in numerous different scenarios. The experimental was tested and verified for three consecutive months. The findings of this study reveal that the proposed method provides 100 percent correct identification of harmonic source location.