Ahmed Hammami
Research Subjects
Ahmed Hammami has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
Adam Pearson
Department of Mechanical and Industrial Engineering, University of Toronto, 5 Kings College Rd, Toronto, ON, M5S 3G8, Canada
7 shared publications- Anil K. Mehrotra
Department of Chemical and Petroleum Engineering University of Calgary Calgary Alberta Canada
7 shared publications Hani E. Naguib
7 shared publicationsMark Duncan
Flexpipe, Mattr Infrastructure Technologies, 3501 54 Ave SE, Calgary, Alberta T2C 0A9, Canada
7 shared publicationsJoel Runka
Flexpipe, Mattr Infrastructure Technologies, 3501 54 Ave SE, Calgary, Alberta T2C 0A9, Canada
6 shared publicationsJohn Ratulowski
Consultant
6 shared publications
Latest Publications
- Open Access
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
A Multiscale Approach to Reducing Gas Permeation in Reinforced Polymer Composite Pipeline Systems
Maximizing containment of gases and vapors in composite pipelines is critical for long‑term, reliable operation. The selection of polymeric barrier materials for liners therefore requires understanding how polymer chemistry and morphology control gas transport. In practice, commercial liner grades may contain proprietary additives, and qualification demands that permeation rates measured on disc specimens cut from the liner wall be consistent with measurements on full pipe sections with connectors. In addition, estimates are needed for the contribution of reinforcement layers to radial and axial permeation towards venting points in different piping configurations.This work applies a multiscale approach to characterize permeation of CO₂, H₂S and CH₄ mixtures through reinforced polymer composite pipes for oil and gas transportation manufactured with different liner chemistries. The methodology, as shown in Figure 1, integrates coupon‑scale measurements of individual‑gas permeation over a broad temperature range with finite‑element modelling and full‑scale pipe tests, thereby reducing uncertainties in long‑term predictions of pipe integrity, fugitive emissions and in‑service venting requirements. Coupon data are used to calibrate the numerical model, which is then validated against whole‑pipe experiments and extended to quantify the contribution of the reinforcement layer to overall permeation.The approach is demonstrated on unbonded glass‑reinforced thermoplastic composite pipes with polyethylene (PE) and polyphenylene sulfide (PPS) liners. Experiments at 103 barg and 82 °C show that upgrading the liner from PE to PPS markedly decreases gas permeation at pipe level, with approximate reductions of 30‑fold for CH₄, 20‑fold for H₂S and 10‑fold for CO₂, in agreement with numerical predictions.
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Multiscale Approach to Reducing Gas Permeation in Reinforced Polymer Composite Pipeline Systems
Maximizing containment of gases and vapors in composite pipelines is critical for long‑term, reliable operation. The selection of polymeric barrier materials for liners therefore requires understanding how polymer chemistry and morphology control gas transport. In practice, commercial liner grades may contain proprietary additives, and qualification demands that permeation rates measured on disc specimens cut from the liner wall be consistent with measurements on full pipe sections with connectors. In addition, estimates are needed for the contribution of reinforcement layers to radial and axial permeation towards venting points in different piping configurations.This work applies a multiscale approach to characterize permeation of CO₂, H₂S and CH₄ mixtures through reinforced polymer composite pipes for oil and gas transportation manufactured with different liner chemistries. The methodology, as shown in Figure 1, integrates coupon‑scale measurements of individual‑gas permeation over a broad temperature range with finite‑element modelling and full‑scale pipe tests, thereby reducing uncertainties in long‑term predictions of pipe integrity, fugitive emissions and in‑service venting requirements. Coupon data are used to calibrate the numerical model, which is then validated against whole‑pipe experiments and extended to quantify the contribution of the reinforcement layer to overall permeation.The approach is demonstrated on unbonded glass‑reinforced thermoplastic composite pipes with polyethylene (PE) and polyphenylene sulfide (PPS) liners. Experiments at 103 barg and 82 °C show that upgrading the liner from PE to PPS markedly decreases gas permeation at pipe level, with approximate reductions of 30‑fold for CH₄, 20‑fold for H₂S and 10‑fold for CO₂, in agreement with numerical predictions.
- Open Access
In Situ Punch–Shear Testing of Polymers
Conventional material aging and testing protocols involve exposing coupon samples to saturation in application fluid(s) at temperature and pressure conditions typically encountered during service, followed by mechanical testing at ambient conditions. This practice can generate misleading results for materials for which fluid ingress is rapidly reversible, most notably at elevated temperatures. A recently developed in situ punch–shear device has been successfully used to establish experimental correlations between the tensile properties (ASTM D638) and shear properties (ASTM D732) of Polyethylene of Raised Temperature (PERT) under dry conditions. It also enabled measurement of shear properties of select polymers while immersed (saturated) in fluids at elevated pressure and temperature. The present work extends the treatment to a suite of commercially available thermoplastic polymers spanning the commodity, engineering, and high-performance polymer grades with varying degrees of hygroscopicity. The objectives of this contribution are three-fold, namely: (i) assess the effect of sample preparation method on measured mechanical properties, (ii) compare the experimentally established correlations between shear and tensile tests for the different class of polymer grades before fluid exposure, and (iii) gauge reversibility of the measured tensile and shear properties after aging in deionized water to saturation at 95 °C. Results indicate that (i) the test coupon preparation method affects the tensile to shear correlation and must be standardized to enable systematic comparison of in situ properties, (ii) individual correlations segregate by polymer family, and (iii) conventional tensile testing after a saturation–dehydration cycle yields optimistic mechanical properties.
Open AccessIn Situ Punch–Shear Testing of Polymers
Conventional material aging and testing protocols involve exposing coupon samples to saturation in application fluid(s) at temperature and pressure conditions typically encountered during service, followed by mechanical testing at ambient conditions. This practice can generate misleading results for materials for which fluid ingress is rapidly reversible, most notably at elevated temperatures. A recently developed in situ punch–shear device has been successfully used to establish experimental correlations between the tensile properties (ASTM D638) and shear properties (ASTM D732) of Polyethylene of Raised Temperature (PERT) under dry conditions. It also enabled measurement of shear properties of select polymers while immersed (saturated) in fluids at elevated pressure and temperature. The present work extends the treatment to a suite of commercially available thermoplastic polymers spanning the commodity, engineering, and high-performance polymer grades with varying degrees of hygroscopicity. The objectives of this contribution are three-fold, namely: (i) assess the effect of sample preparation method on measured mechanical properties, (ii) compare the experimentally established correlations between shear and tensile tests for the different class of polymer grades before fluid exposure, and (iii) gauge reversibility of the measured tensile and shear properties after aging in deionized water to saturation at 95 °C. Results indicate that (i) the test coupon preparation method affects the tensile to shear correlation and must be standardized to enable systematic comparison of in situ properties, (ii) individual correlations segregate by polymer family, and (iii) conventional tensile testing after a saturation–dehydration cycle yields optimistic mechanical properties.
- 26 February 2025
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 64 (10) , 5359-5371
Low-Concentration Graphene Nanoplatelet/HDPE Nanocomposites with Enhanced Dispersion and Interfacial Bonding for Improved CO2 Barrier and Mechanical Performance at Elevated Temperatures
- 26 February 2025
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 64 (10) , 5359-5371
Low-Concentration Graphene Nanoplatelet/HDPE Nanocomposites with Enhanced Dispersion and Interfacial Bonding for Improved CO2 Barrier and Mechanical Performance at Elevated Temperatures
- Open Access
- 29 January 2025
- Published by Elsevier in Journal of Manufacturing Processes
- Vol. 136, 217-227
Adhesion dynamics and interfacial behavior at room and high temperatures of ethylene vinyl alcohol/polyethylene-grafted maleic anhydride composite multilayer films obtained by co-extrusion
- 29 January 2025
- Published by Elsevier in Journal of Manufacturing Processes
- Vol. 136, 217-227
Open AccessAdhesion dynamics and interfacial behavior at room and high temperatures of ethylene vinyl alcohol/polyethylene-grafted maleic anhydride composite multilayer films obtained by co-extrusion
- Open Access
- 15 October 2024
- Published by Royal Society of Chemistry (RSC) in RSC Applied Polymers
- Vol. 2 (6) , 1170-1181
A polyamide and polyethylene multilayer composite with enhanced barrier and mechanical properties at high temperature
An advanced multilayer thermoplastic composite, composed of Polyethylene of Raised Temperature (PERT), Polyamide 12 (PA12), and Maleic Anhydride Grafted Polyethylene (MA), has been developed for high-temperature, high-pressure applications. An adhesive layer consisting of 35–60–5 wt% PERT-PA12-MA (Blend), has been tailored to optimize adhesive strength between PERT and PA12 layers. The developed three-layer composite (Trilayer) demonstrated exceptional water vapor and CO2 barrier properties by incorporating PERT as a water transmission retarder and PA12 as a CO2 diffusion retarder. At 82 °C, the water vapor transmission rate and CO2 permeability of Trilayer samples were 58%, and 31% lower than those of the Blend, respectively. The Trilayer samples exhibited an average Young's modulus that was 17% higher than that of the Blend, while the yield stress was similar to the Blend. In terms of creep resistance, the Trilayer samples showed a 29% and 40% reduction in tensile creep strain and creep rate, respectively, compared to the Blend. Additionally, the Trilayer samples achieved 48% and 39% decreases in flexural creep strain and creep rate, respectively, in the flexural creep test. The Trilayer also exhibited a 56% decrease in deformation under drop-weight impact and a 14% improved impact absorption compared to the Blend. The overall performance of the multi-layer thermoplastic composite made from PERT and PA12 constituents was significantly enhanced, aligning with the carbon footprint reduction initiative to substitute thermoset, metal, and other traditional materials.
- 15 October 2024
- Published by Royal Society of Chemistry (RSC) in RSC Applied Polymers
- Vol. 2 (6) , 1170-1181
Open AccessA polyamide and polyethylene multilayer composite with enhanced barrier and mechanical properties at high temperature
An advanced multilayer thermoplastic composite, composed of Polyethylene of Raised Temperature (PERT), Polyamide 12 (PA12), and Maleic Anhydride Grafted Polyethylene (MA), has been developed for high-temperature, high-pressure applications. An adhesive layer consisting of 35–60–5 wt% PERT-PA12-MA (Blend), has been tailored to optimize adhesive strength between PERT and PA12 layers. The developed three-layer composite (Trilayer) demonstrated exceptional water vapor and CO2 barrier properties by incorporating PERT as a water transmission retarder and PA12 as a CO2 diffusion retarder. At 82 °C, the water vapor transmission rate and CO2 permeability of Trilayer samples were 58%, and 31% lower than those of the Blend, respectively. The Trilayer samples exhibited an average Young's modulus that was 17% higher than that of the Blend, while the yield stress was similar to the Blend. In terms of creep resistance, the Trilayer samples showed a 29% and 40% reduction in tensile creep strain and creep rate, respectively, compared to the Blend. Additionally, the Trilayer samples achieved 48% and 39% decreases in flexural creep strain and creep rate, respectively, in the flexural creep test. The Trilayer also exhibited a 56% decrease in deformation under drop-weight impact and a 14% improved impact absorption compared to the Blend. The overall performance of the multi-layer thermoplastic composite made from PERT and PA12 constituents was significantly enhanced, aligning with the carbon footprint reduction initiative to substitute thermoset, metal, and other traditional materials.
- 6 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (16) , 9817-9828
High-Temperature Multilayer Composite Films of Polyethylene/Ethylene Vinyl Alcohol with Enhanced Flexural Moduli and Gas Barrier Properties
- 6 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (16) , 9817-9828
High-Temperature Multilayer Composite Films of Polyethylene/Ethylene Vinyl Alcohol with Enhanced Flexural Moduli and Gas Barrier Properties
- 28 July 2024
- Published by ASME International
Peel Strength of Multilayer Polymer-Based Pipes
Multilayer polymer composite piping typically comprises a primarily load-bearing structural layer and one or two inner and outer protective layers. The latter aims to protect the structural layer from damage caused during installation and operation. Multilayer pipes are an attractive alternative to conventional single-layer composite piping and are sought for elevated temperatures and pressure operation for oil and gas transportation. Concerns associated with multilayer pipes are fluid permeation, lack of barrier performance, and inadequate adhesion between layers. Rapid gas decompression (RGD) testing replicates the rapid decrease in pressure that may occur in operation. It helps identify defects in the pipe design, materials, and/or fabrication, leading to layer separation and even pipe collapse. However, RGD testing is expensive, requires complex equipment, and may pose safety risks. Therefore, an alternative safe, expedient, and cost-effective procedure is sought. In response to this need, peel testing is investigated according to the DIN 53357 standard, also known as German wheel peel testing. A peel test apparatus has been adapted based on the DIN 53357 standard in the present work. Results from testing five-layer polymer-based pipes are reported in the present study. Baseline tests were performed at room temperature at a 10 mm/minute peel rate on a 10 mm wide and 2.5 mm thick peel strip. The influence of peel rate, peel strip width and thickness, and temperatures were investigated in this work. This contribution concludes with a discussion about the effects of these parameters and the suitability of peel testing for multilayer pipes.
- 28 July 2024
- Published by ASME International
Peel Strength of Multilayer Polymer-Based Pipes
Multilayer polymer composite piping typically comprises a primarily load-bearing structural layer and one or two inner and outer protective layers. The latter aims to protect the structural layer from damage caused during installation and operation. Multilayer pipes are an attractive alternative to conventional single-layer composite piping and are sought for elevated temperatures and pressure operation for oil and gas transportation. Concerns associated with multilayer pipes are fluid permeation, lack of barrier performance, and inadequate adhesion between layers. Rapid gas decompression (RGD) testing replicates the rapid decrease in pressure that may occur in operation. It helps identify defects in the pipe design, materials, and/or fabrication, leading to layer separation and even pipe collapse. However, RGD testing is expensive, requires complex equipment, and may pose safety risks. Therefore, an alternative safe, expedient, and cost-effective procedure is sought. In response to this need, peel testing is investigated according to the DIN 53357 standard, also known as German wheel peel testing. A peel test apparatus has been adapted based on the DIN 53357 standard in the present work. Results from testing five-layer polymer-based pipes are reported in the present study. Baseline tests were performed at room temperature at a 10 mm/minute peel rate on a 10 mm wide and 2.5 mm thick peel strip. The influence of peel rate, peel strip width and thickness, and temperatures were investigated in this work. This contribution concludes with a discussion about the effects of these parameters and the suitability of peel testing for multilayer pipes.
- 28 September 2023
- Published by Elsevier in Composites Science and Technology
- Vol. 244
Carbon fiber reinforced polyethylene composite adhesive at elevated temperatures
- 28 September 2023
- Published by Elsevier in Composites Science and Technology
- Vol. 244
Carbon fiber reinforced polyethylene composite adhesive at elevated temperatures
- Open Access
- 10 February 2023
- Published by Elsevier in Materials & Design
- Vol. 227
Supercritical CO2 permeation in polymeric films: Design, characterization, and modeling
- 10 February 2023
- Published by Elsevier in Materials & Design
- Vol. 227
Open AccessSupercritical CO2 permeation in polymeric films: Design, characterization, and modeling
- 13 October 2022
- Published by Elsevier in Composites Science and Technology
- Vol. 230
Effect of temperature on the fiber-matrix adhesion in glass fiber reinforced thermoplastics
- 13 October 2022
- Published by Elsevier in Composites Science and Technology
- Vol. 230
Effect of temperature on the fiber-matrix adhesion in glass fiber reinforced thermoplastics