YMYintao Ma

Yintao Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yintao Ma has a total of 28 co-authors. Here are the top co-authors by number of shared publications:

  • Ju Guo

    State Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi'an Jiaotong University 2 , Xi'an 710049

    10 shared publications
  • Yao Chen

    School of Instrument Science and Technology, Xi'an Jiaotong University 1 , Xi'an 710049

    10 shared publications
  • Yanbin Wang

    State Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi'an Jiaotong University 2 , Xi'an 710049

    9 shared publications
  • Libo Zhao

    School of Instrument Science and Technology, Xi’an Jiaotong University, Xi’an, China

    8 shared publications
  • Ping Yang

    State Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi’an Jiaotong University, Xi’an, China

    7 shared publications
  • Mingzhi Yu

    State Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi’an Jiaotong University, Xi’an, China

    6 shared publications

Latest Publications

  • Machine learning-assisted design of zero magnetic temperature-control chips for on-chip quantum sensors

    by Yintao Ma, Di Xiao, Pan Chen, Ju Guo, Yao Chen, Yanbin Wang, Mingzhi Yu, Qijing Lin, Dejiang Lu, Libo Zhao

    Alkali-vapor atom-based quantum sensors are urgently needed in the cutting-edge frontier of extremely weak field measurements. However, the generation and control of atomic vapor currently heavily rely on the flexible heater and the discrete temperature sensor, which severely hinder practical application. Herein, we report on-chip, high-performance temperature-control chips with very low residual magnetic flux density, enabled by the multipole-field suppression microstructure designed by particle swarm optimization algorithms, achieving two to three orders of magnitude reduction compared with conventional structures. The unique structure is formed by multiturn parallel winding arrangement, resulting in a synergistic cancelation of the stray magnetic field. A one-step manufacturing process based on oxygen plasma treatment and metal lift-off facilitated tough adhesion is developed for high-efficiency fabrication. As a result, a low magnetic field coefficient of ∼4.3 pT/mA, a high heating power of ∼1 W, and an exceptional temperature fluctuation of ±10 mK are reached, which represents significant improvement in comprehensive performance compared to previous reports. Furthermore, we configure a chip-scale quantum magnetometer with the optimal sensitivity of 10 fT/Hz1/2. Benefiting from its high-performance capabilities, integrated functionality, and the straightforward microfabrication process, the methods reported here are, in principle, generalizable to all thermal alkali-atom-based quantum sensors, including atomic magnetometers, atomic clocks, atomic gyroscopes, and beyond.

  • Open Access

    Magnetron-Sputtered MEMS Bi-Planar Coils for Chip-Scale SERF Magnetometry and Ultra-Low-Field NMR Relaxometry

    by Yao Chen, Zhipeng Sun, Yintao Ma, Yanjie Zhang, Lun Zou, Mingzhi Yu, Yanbin Wang, Libo Zhao

    Miniaturizing magnetic-field compensation for atomic spin sensors is challenging with conventional 3D wire-wound coils. We report the MEMS design, fabrication and system-level validation of bi-planar coils for a chip-scale spin-exchange relaxation-free (SERF) atomic magnetometer. Confining conductors to two parallel planes preserves full three-axis field control and makes the field accuracy lithography-limited. For an 8 mm × 8 mm footprint with 7.5 mm plane separation, finite-element analysis predicts coil constants of 81.3nT/mA (in-plane) and 438.6nT/mA (normal), with 0.2% and 0.02% non-uniformity over a 2 × 2 × 2 mm³ target volume. Coils were patterned with 40 μm traces and integrated into a 12 × 15 × 43 mm packaged head. Two independent calibrations were performed: reference-coil substitution (giving 68.2 and 396.0 nT/mA; 16.1% and 9.7% below simulation) and in-situ 129Xe free-precession calibration in a ϕ3 × 3 mm cell (yielding 74.3 and 433.6 nT/mA; within 8.6% and 1.1% of simulation). The in-situ approach removes the reference scale factor and directly samples the interrogated volume, validating the numerical model. With 1 kHz modulation, the integrated noise floor reached 38fT/Hz1/2 and enabled ULF-NMR at 100 nT, resolving water-proton precession and linear CuSO4 relaxometry down to 50 μM.

  • Open Access

    MEMS vapor cells-based Rydberg-atom electrometry toward miniaturization and high sensitivity

    by Yintao Ma, Pan Chen, Mingzhi Yu, Yao Chen, Yanbin Wang, Ju Guo, Man Zhao, Ping Yang, Qijing Lin, Libo Zhao

    Rydberg-atom electrometry, as an emerging cutting-edge technology, features high sensitivity, broad bandwidth, calibration-free operation, and beyond. However, until now the key atomic vapor cells used for confining electric field-sensitive Rydberg atoms nearly made with traditional glass-blown techniques, hindering the miniaturization, integration, and batch manufacturing. Here, we present the wafer-level MEMS atomic vapor cells with glass-silicon-glass sandwiched structure that are batch-manufactured for both frequency stability and electric field measurement. We use specially customized ultra-thick silicon wafers with a resistivity exceeding 10,000 Ω cm, three orders of magnitude higher than that of typical silicon, and a thickness of 6 mm, providing a 4-fold improvement in optical interrogation length. With the as-developed MEMS atomic vapor cell, we configured a high-sensitivity Rydberg-atom electrometry with the minimal detectable microwave field to be 2.8 mV/cm. This combination of miniaturization and sensitivity represents a significant advance in the state-of-the-art field of Rydberg-atom electrometry, paving the way for chip-scale Rydberg-atom electrometry and potentially opening up new applications in a wider variety of fields. The alternative text for this image may have been generated using AI.

  • Open Access

    Tesla-scale magnetic field measurement based on Sideband-overlap Zeeman spectroscopy using a functionalized MEMS vapor cell

    by Ju Guo, Yintao Ma, Dejiang Lu, Mingzhi Yu, Yanbin Wang, Ping Yang, Qijing Lin, Libo Zhao, Yao Chen

    Accurate measurement of strong magnetic fields in the Tesla range remains a persistent challenge due to calibration drift, nonlinearity, and spatial gradient sensitivity. Here, we present a compact magnetometry approach based on sideband-overlap Zeeman spectroscopy, enabled by a functionalized MEMS cesium vapor cell. The vapor cell features a dual-chamber glass–Si–glass structure with integrated microheaters on the optical window. A first-order electro-optic modulator produces optical sidebands aligned with the σ+ and \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{-}$$σ− Zeeman-split components of the Cs D1 line under the hyperfine Paschen–Back regime. Magnetic field scanning from zero to Tesla-scale fields enables extraction of the frequency offset between reference and Zeeman-shifted spectra. This frequency shift is directly converted into magnetic field strength using Zeeman spectroscopy in the hyperfine Paschen–Back regime. The method resolves sixteen Zeeman transitions (eight \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{+}$$σ+ and eight \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{-}$$σ−), allowing measurement of a field strength of 0.6694921 T, with a single-shot resolution of 6.4 μT and a cross-transition repeatability of σB = 8.9 μT (corresponding to 13 ppm at 0.6695 T). In a millimeter-scale sensing volume, the system achieves sub-10 μT repeatability without requiring a uniform bias field. These results indicate that the microfabricated high-field magnetometer can serve as a compact and practical approach for Tesla-range field measurement and pave the way for chip-scale quantum devices.

  • Open Access

    Correction to “Nuclear Spin Relaxation and Electric Quadrupole Frequency Shift of 129 Xe- 131 Xe in Cubic Stemless MEMS Atomic Vapor Cells”

    by Mingzhi Yu, Yanbin Wang, Yintao Ma, Yao Chen, Ju Guo, Liubo Zhang, Ping Yang, Xiangguang Han, Yang Lv, Libo Zhao

    [This corrects the article DOI: 10.1021/acsomega.5c04797.].

  • Open Access

    Nuclear Spin Relaxation and Electric Quadrupole Frequency Shift of 129Xe-131Xe in Cubic Stemless MEMS Atomic Vapor Cells

    by Mingzhi Yu, Yanbin Wang, Yintao Ma, Yao Chen, Ju Guo, Liubo Zhang, Ping Yang, Xiangguang Han, Yang Lv, Libo Zhao

    Research on the electric quadrupole frequency shift mechanism and nuclear spin relaxation of 129Xe-131Xe in alkali metal atomic vapor cells fabricated using microelectromechanical systems (MEMS) technology remains in its early stages. Therefore, an in-depth investigation in this field is crucial for enhancing the performance of miniaturized atomic gyroscopes and other quantum devices. This study provides a comprehensive analysis of the electric quadrupole frequency shift and relaxation of 129Xe-131Xe nuclear spins in a stemless cubic MEMS vapor cell. To elucidate the microscopic characteristics of wall interactions, nuclear spin quadrupole interactions with mixed silicon and glass surfaces in MEMS vapor cells were examined. The influence of the angle between the vapor cell's geometric axis and the applied magnetic field on the electric quadrupole frequency shift was investigated, leading to the determination of the vapor cell's asymmetry parameter η and the average twist angle ⟨θ⟩ of nuclear spin-wall collisions. Furthermore, the temperature dependence of the electric quadrupole frequency shift in 131Xe atoms was characterized, enabling the extraction of the desorption activation energy (E A ) of 131Xe on the MEMS vapor cell surface. By analyzing the free induction decay (FID) signals of 129Xe and 131Xe at varying temperatures, the relationship between their relaxation rates and temperature was established. These findings offer valuable insights for optimizing nuclear spin relaxation times in microatomic gyroscopes.


  • Open Access

    MEMS Vapor Cells-based Rydberg-atom Electrometry Toward Miniaturization and High Sensitivity

    by Yintao Ma, Beibei Sun, Pan Chen, Yao Chen, Yanbin Wang, Ju Guo, Mingzhi Yu, Ping Yang, Qijing Lina, Libo Zhao

    Rydberg-atom electrometry, as an emerging cutting-edge technology, features high sensitivity, broad bandwidth, calibration-free operation, and beyond. However, until now the key atomic vapor cells used for confining electric field-sensitive Rydberg atoms nearly made with traditional glass-blown techniques, hindering the miniaturization, integration, and batch manufacturing. Here, we present the wafer-level MEMS atomic vapor cells with glass-silicon-glass sandwiched structure that are batch-manufactured for both frequency stability and electric field measurement. We use specially customized ultra-thick silicon wafers with a resistivity exceeding 10,000 cm, three orders of magnitude higher than that of typical silicon, and a thickness of 6 mm, providing a 4-fold improvement in optical interrogation length. With the as-developed MEMS atomic vapor cell, we configured a high-sensitivity Rydberg-atom electrometry with the minimal detectable microwave field to be 2.8 mV/cm. This combination of miniaturization and sensitivity represents a significant advance in the state-of-the-art field of Rydberg-atom electrometry, paving the way for chip-scale Rydberg-atom electrometry and potentially opening up new applications in a wider variety of fields.

  • Collision-induced interaction dynamics of hyperpolarized nuclear spins in functionalized microfabricated vapor cells for chip-scale quantum devices

    by Yintao Ma, Yao Chen, Mingzhi Yu, Yanbin Wang, Ju Guo, Liubo Zhang, Ping Yang, Qijing Lin, Dejiang Lu, Libo Zhao

  • High-Sensitivity, Microfabricated Quantum Magnetometers With an Intelligent Solar Heating System

    by Yintao Ma, Yao Chen, Mingzhi Yu, Yanbin Wang, Ju Guo, Man Zhao, Ping Yang, Qijing Lin, Libo Zhao

    Atomic magnetometers, a prominent class of quantum sensors, have become increasingly significant in magnetometry, with extensive applications in cutting-edge physics, biomedical imaging, industrial inspection, and beyond. However, the power consumption of an atomic magnetometer is primarily dominated by that demanded to heat the atomic vapor cell to its operating temperature. This operating temperature determines the alkali-metal atomic density, thereby influencing the magnetic field sensitivity and overall power consumption, which poses a potential obstacle to the large-scale engineering application of atomic magnetometers. In this article, a novel heating method utilizing renewable solar energy is proposed for the first time, which can surpass the limitation of conventional heating methods in thermo-atom-based quantum sensors. By exploiting an intelligent closed-loop control system to adaptively regulate the functionalized sunlight power, this proposed method has the capability of both high heating efficiency and accuracy. The heating properties and laser absorption spectrum at different temperatures up to 180 °C are characterized substantiating the feasibility of utilizing sunlight. Moreover, a sunlight-heated, highly sensitive, microfabricated atomic magnetometer with a magnetic field sensitivity of 18 fT/Hz 1/2 is demonstrated. And the single-chamber microelectromechanical system atomic vapor cell as the key component is fabricated by utilizing deep silicon micromachining and anodic bonding techniques. This proposed technique can be further extended to all quantum sensing systems based on thermal atomic ensembles and open up new possibilities for the development of self-powered, environmentally friendly quantum sensors.


  • Accurate determination of alkali atom density based on zero-field magnetic resonance in a single-beam spin-exchange relaxation-free atomic magnetometer

    by Yintao Ma, Yao Chen, Libo Zhao, Mingzhi Yu, Yanbin Wang, Ju Guo, Ping Yang, Qijing Lin, Zhuangde Jiang

    A single-beam spin-exchange relaxation-free (SERF) atomic magnetometer can extract vector magnetic field information by detecting the transmission intensity of a resonant circularly polarized pumping beam, which depends sensitively on the atomic density of the alkali metal. We present a novel scheme to determine atomic density based on zero-field magnetic resonance. The resonance linewidth under different transverse DC magnetic fields is fitted by means of a quadratic function. The atomic density can be extracted from the quadratic coefficients of the fitted function. The experimental results indicate that the deviation of measured density is less than two times compared with the theoretical values between 378 K and 403 K. Furthermore, the influence of modulation field on resonance linewidth is investigated experimentally and theoretically. A miniature single-beam SERF atomic magnetometer with a sensor head volume of only 16.2 cm 3 and the measuring sensitivity of 40 fT/ Hz 1/2 has been achieved. These results should be beneficial for guiding the development of a chip-scale atomic magnetometer with high sensitivity and spatial resolution for bio-magnetic field imaging applications.