JSJan Suchánek

Jan Suchánek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan Suchánek has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Towards Reconstructable CF-LIBS Quantification: A Perspective on Reporting, Validation, and Reproducibility

    by Homa Saeidfirozeh, Petr Kubelík, Jan Suchánek, Jakub Buday, Pavel Pořízka, Jozef Kaiser, Martin Ferus

    Calibration free laser induced breakdown spectroscopy (CF-LIBS) estimates elemental composition using a plasma model, offering a practical approach where suitable reference standards are unavailable. This Perspective proposes reconstructability as a reporting objective, distinct from physical validity and fitness for purpose. Five checkpoints organize the calculation, illustrated through constructed examples and selected calculations from three published records. The constructed generator and reconstruction share a model; their agreement tests the reporting record, not physical validity. Under the specified ternary-system and uncertainty assumptions, six of nine convention slips move the light minor constituent outside its propagated 95% interval, and three indicators flag seven of nine slips. These counts are case specific. The two undetected linewidth slips are examined in 43 gated xenon–hydrogen spectra using hydrogen lines as a separate density diagnostic. For two bins with median instrumental-to-observed width ratios of 0.50 and 0.58, retaining the instrumental width gives densities 36–61% above the hydrogen-derived estimates and quadrature subtraction by 16–33%, consistent with the calculated effect. Four pulse-energy cases for one regolith simulant demonstrate reconstruction from measured spectra and comparison with X-ray fluorescence (XRF) on a common elemental mass-ratio basis. We distinguish core from recommended reporting items and supply a copyable template. Three analysts recover specified outputs using the supplied code; broader usability and interlaboratory performance remain to be evaluated.

  • Open Access

    Review on Monitoring and Measurement Strategies for Ammonia Combustion-Related N2O Emissions

    by Hana Chaloupecká, Václav Nevrlý, Jan Suchánek, Milan Mamula, Michal Dostál, Vít Klečka, Jan Wild

    While global decarbonization and low-temperature engines curb nitrogen oxides, they risk significant N2O emissions, which is also one of the greenhouse gases. This review evaluates N2O monitoring strategies across maritime and industrial combustion environments. Furthermore, this paper provides a rigorous comparative assessment of analytical monitoring methodologies. We evaluate the adaptability of established agricultural techniques. In parallel, advanced spectroscopic and non-spectroscopic sensor technologies (DAS, NDIR, TDLAS, PAS, CRDS, CEAS, FTIR, GC, and electrochemical/chemiresistive sensors) are critically analyzed regarding their sensitivity, response time, cross-interference vulnerabilities, and suitability for harsh industrial stacks and maritime settings. Finally, the levels of N2O above background from individual sources are estimated using wind-tunnel modeling studies. Emissions from ships, truck lines, and industrial turbines typically cause urban ambient concentrations ranging from hundreds down to tens of ppb, whereas individual trucks and rural ship levels are significantly lower, from below 1 ppb up to about 70 ppb depending on engine optimization. For industrial and combustion sources, real-time N2O analysis can be performed using FTIR, which allows for multi-gas mixture measurement, or TDLAS for targeted N2O detection. For distributed screening and monitoring around industrial plants, NDIR is a technically viable option under specific conditions. For mobile sources, TDLAS, FTIR, and highly sensitive cavity-enhanced methods (CRDS, CEAS) are suitable, provided they are optimized for harsh conditions. NDIR is applicable here only in dense urban areas. In all scenarios, gas chromatography can be used, though it requires physical sample collection and does not offer real-time analysis. As we will show, electrochemical and chemiresistive sensors cannot currently be used. Similarly, PAS is unsuitable for ambient enhancement detection, despite its applicability to stack sampling.

  • Open Access

    Varying Performance of Low-Cost Sensors During Seasonal Smog Events in Moravian-Silesian Region

    by Václav Nevrlý, Michal Dostál, Petr Bitala, Vít Klečka, Jiří Sléžka, Pavel Polách, Katarína Nevrlá, Melánie Barabášová, Růžena Langová, Šárka Bernatíková, et al.

    Air pollution monitoring in industrial regions like Moravia-Silesia faces challenges due to complex environmental conditions. Low-cost sensors offer a promising, cost-effective alternative for supplementing data from regulatory-grade air quality monitoring stations. This study evaluates the accuracy and reliability of a prototype node containing low-cost sensors for carbon monoxide (CO) and particulate matter (PM), specifically tailored for the local conditions of the Moravian-Silesian Region during winter and spring periods. An analysis of the reference data observed during the winter evaluation period showed a strong positive correlation between PM, CO, and NO2 concentrations, attributable to common pollution sources under low ambient temperature conditions and increased local heating activity. The Sensirion SPS30 sensor exhibited high linearity during the winter period but showed a systematic positive bias in PM10 readings during Polish smog episodes, likely due to fine particles from domestic heating. Conversely, during Saharan dust storm episodes, the sensor showed a negative bias, underestimating PM10 levels due to the prevalence of coarse particles. Calibration adjustments, based on the PM1/PM10 ratio derived from Alphasense OPC-N3 data, were initially explored to reduce these biases. For the first time, this study quantifies the influence of particle size distribution on the SPS30 sensor’s response during smog episodes of varying origin, under the given local and seasonal conditions. In addition to sensor evaluation, we analyzed the potential use of data from the Copernicus Atmospheric Monitoring Service (CAMS) as an alternative to increasing sensor complexity. Our findings suggest that, with appropriate calibration, selected low-cost sensors can provide reliable data for monitoring air pollution episodes in the Moravian-Silesian Region and may also be used for future adjustments of CAMS model predictions.


  • Open Access

    Varying Performance of Low-Cost Sensors During Seasonal Smog Events in Moravian-Silesian Region

    by Václav Nevrlý, Michal Dostál, Petr Bitala, Vit Klecka, Jiří Sléžka, Pavel Polach, Katarína Nevrlá, Melánie Barabášová, Růžena Langová, Sarka Bernatikova, et al.

    This study examines the varying performance of low-cost sensors during seasonal smog events, particularly those resulting from solid fuel combustion linked to residential or industrial heating and other pollution sources. A prototype low-cost sensor node developed within this work was collocated for several months with reference equipment at an air quality monitoring station in the city of Ostrava (Moravian-Silesian region, Czech Republic). Deterioration of air quality during a pair of smog alert events, namely wintertime "Polish smog" episode and springtime "Saharan dust storm", which occurred through the extended period of co-location, was characterized quantitatively based on particulate matter and carbon monoxide concentrations measured by the low-cost sensors. These datasets were compared with reference data and model predictions provided by the Copernicus Atmospheric Monitoring Service. Selected low-cost sensors demonstrated linear response during Polish smog episode with highly correlated time series of carbon monoxide and particulate matter concentrations. However, when compared to reference data, the Sensirion SPS30 sensor is found to overestimate coarse particle (PM10) concentrations by the factor of two during winter evaluation period. On the other hand, oppositely biased PM10 response (underestimation by the factor of five) was determined from co-location measurement during Saharan dust storm event. This observation was attributed to combination of specific detection efficiency of the given low-cost sensor and shifts in particle size distribution due to seasonal change of ambient conditions.


  • Open Access

    Methodology for Simultaneous Analysis of Photocatalytic deNOx Products

    by Jan Suchanek, Eva Vaneckova, Michal Dostal, Eliska Mikyskova, Libor Brabec, Radek Zouzelka, Jiri Rathousky

    The ISO standard 22197-1:2016 used for the evaluation of the photocatalytic nitric oxide removal has a main drawback, which allows only the decrease of nitric oxide to be determined specifically. The remaining amount, expressed as “NO2”, is considered as a sum of HNO3, HONO NO2, and other nitrogen-containing species, which can be potentially formed during the photocatalytic reaction. Therefore, we developed a new methodology combining our custom-made analyzers, which can accurately determine the true NO2 and HONO species, with the conventional NO one. Their function was validated via a photocatalytic experiment in which 100 ppbv of either NO or NO2 dispersed in air passed over (3 L min−1) an Aeroxide© TiO2 P25 surface. The gas-phase analysis was complemented with the spectrophotometric determination of nitrates (NO3−) and/or nitrites (NO2−) deposited on the P25 layer. Importantly, an almost perfect mass balance (94%) of the photocatalytic NOx abatement was achieved. The use of custom-made analyzers enables to obtain (i) no interference, (ii) high sensitivity, (iii) good linearity in the relevant concentration range, (iv) rapid response, and (v) long-term stability. Therefore, our approach enables to reveal the reaction complexity and is highly recommended for the photocatalytic NOx testing.