Abderrahim El-Abidi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abderrahim El-Abidi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Said Yadir
Laboratory of Materials, Processes, Environment and Quality (LMPEQ), National School of Applied Sciences of Safi, Cadi Ayyad University, Route Sidi Bouzid BP 63, 46000 Safi, Morocco
3 shared publications - Wail El Bazi
Laboratory of Process Engineering, Computer Science and Mathematics, Department of Process Engineering (LIPIM), National School of Applied Sciences of Khouribga, Sultan Moulay Slimane University, Bd Béni Amir, BP 77, 25000, Khouribga, Morocco
2 shared publications Wail El-Bazi
Laboratory of Process Engineering, Computer Science and Mathematics, the National School of Applied Sciences, Sultan Moulay Slimane University , BP 77, 25000 Khouribga
2 shared publicationsBajil Ouartassi
Laboratory of Process Engineering, Department of Computer Science and Mathematics, National School of Applied Sciences, Sultan Moulay Slimane University, Bd Béni Amir, BP 77, 25000, Khouribga, Morocco
1 shared publication- Brahim Messnaoui
Laboratory of Materials, Processes, Environment and Quality (LMPEQ), National School of Applied Sciences of Safi, Cadi Ayyad University, Route Sidi Bouzid BP 63, 46000 Safi, Morocco
1 shared publication - Elhadi Baghaz
Laboratory of Electronics, Instrumentation and Energetic, Faculty of Sciences Chouaïb Doukkali University El Jadida Morocco
1 shared publication
Latest Publications
- Open Access
- 22 October 2025
- Published by Oxford University Press (OUP) in Clean Energy
- Vol. 10 (1) , 158-172
Comparative numerical analysis of 11 low-cost single-pass photovoltaic/thermal solar collectors for air heating
In the context of a growing demand for sustainable energy, air-based photovoltaic-thermal systems offer a promising solution for the simultaneous production of electricity and heat. This work aims to identify the optimal configuration of a low-cost, single-pass air-based photovoltaic-thermal system capable of producing hot air for certain activities in the Safi region (Morocco), such as drying agricultural or marine products, heating buildings, or air conditioning greenhouses, while ensuring electrical autonomy. The study is distinguished by a systematic investigation of an extended set of candidate air-based photovoltaic-thermal configurations (11 in total). 3D simulations were carried out using COMSOL Multiphysics under identical conditions: solar irradiance of 1000 W/m2, inlet/ambient air temperature of 30°C, wind speed of 1 m/s, a fixed collector tilt of 32°, and air mass flow rates of 30, 60, and 90 kg/h. Under these conditions, the unglazed UG2 and UG4 configurations achieve the highest electrical efficiencies (≈17%), while UG5 yields the highest overall exergy efficiency (≈19%). G6 stands out by delivering the highest thermal efficiency (≈25.6%), the highest overall energy efficiency (31.04–38.35%), and outlet air temperatures above 50°C, while maintaining a satisfactory electrical efficiency (≈13%). G6 also attains the highest Type II overall energy efficiency (50.22–64.00%), indicating greater primary energy savings potential and, consequently, the largest associated CO2 reductions. Aligned with the study objectives, G6 is best suited to autonomous thermal applications, while UG5 is preferable when electricity production is the overriding priority.
- 22 October 2025
- Published by Oxford University Press (OUP) in Clean Energy
- Vol. 10 (1) , 158-172
Open AccessComparative numerical analysis of 11 low-cost single-pass photovoltaic/thermal solar collectors for air heating
In the context of a growing demand for sustainable energy, air-based photovoltaic-thermal systems offer a promising solution for the simultaneous production of electricity and heat. This work aims to identify the optimal configuration of a low-cost, single-pass air-based photovoltaic-thermal system capable of producing hot air for certain activities in the Safi region (Morocco), such as drying agricultural or marine products, heating buildings, or air conditioning greenhouses, while ensuring electrical autonomy. The study is distinguished by a systematic investigation of an extended set of candidate air-based photovoltaic-thermal configurations (11 in total). 3D simulations were carried out using COMSOL Multiphysics under identical conditions: solar irradiance of 1000 W/m2, inlet/ambient air temperature of 30°C, wind speed of 1 m/s, a fixed collector tilt of 32°, and air mass flow rates of 30, 60, and 90 kg/h. Under these conditions, the unglazed UG2 and UG4 configurations achieve the highest electrical efficiencies (≈17%), while UG5 yields the highest overall exergy efficiency (≈19%). G6 stands out by delivering the highest thermal efficiency (≈25.6%), the highest overall energy efficiency (31.04–38.35%), and outlet air temperatures above 50°C, while maintaining a satisfactory electrical efficiency (≈13%). G6 also attains the highest Type II overall energy efficiency (50.22–64.00%), indicating greater primary energy savings potential and, consequently, the largest associated CO2 reductions. Aligned with the study objectives, G6 is best suited to autonomous thermal applications, while UG5 is preferable when electricity production is the overriding priority.
- Open Access
- 10 July 2025
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 14 (5) , 914-926
Advanced one-dimensional heterogeneous model for high temperature water gas shift membrane reactors
To predict the behavior of small-scale WGS membrane reactors, a new model based on the 1D heterogeneous approach was developed. Unlike most studies, which rely on 1D pseudo-homogeneous models—typically limited to reactors filled with small catalyst particles which are prone to misestimating catalytic effectiveness when larger catalyst grains are used in which mass transfer resistance is usually considered only within the dense membrane layer which a valid assumption only when this layer is thick, the proposed model adapts to a wide range of catalyst sizes and geometries and also accounts for resistance in the porous stainless steel support of the membrane. This makes it suitable when the dense layer is thin.Comparison with experimental data under various conditions validated the model’s ability to predict the behavior of reactors packed with large catalyst particles (Vgrain ≈ 169 mm³). Therefore, the developed 1D heterogeneous model accurately predicts membrane reactor behavior without resorting to more complex 2D models. Simulations highlighted the significant influence of particle geometry on the catalyst effectiveness factor throughout the reactor, while its impact on carbon monoxide conversion, hydrogen partial pressure, and the temperature profile is especially pronounced near the reactor inlet. Additionally, results showed that sweep gas use accelerates the reaction and aids hydrogen permeation. Finally, CO conversion in the membrane reactor reached 1.3 times that of a conventional fixed-bed reactor.
- 10 July 2025
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 14 (5) , 914-926
Open AccessAdvanced one-dimensional heterogeneous model for high temperature water gas shift membrane reactors
To predict the behavior of small-scale WGS membrane reactors, a new model based on the 1D heterogeneous approach was developed. Unlike most studies, which rely on 1D pseudo-homogeneous models—typically limited to reactors filled with small catalyst particles which are prone to misestimating catalytic effectiveness when larger catalyst grains are used in which mass transfer resistance is usually considered only within the dense membrane layer which a valid assumption only when this layer is thick, the proposed model adapts to a wide range of catalyst sizes and geometries and also accounts for resistance in the porous stainless steel support of the membrane. This makes it suitable when the dense layer is thin.Comparison with experimental data under various conditions validated the model’s ability to predict the behavior of reactors packed with large catalyst particles (Vgrain ≈ 169 mm³). Therefore, the developed 1D heterogeneous model accurately predicts membrane reactor behavior without resorting to more complex 2D models. Simulations highlighted the significant influence of particle geometry on the catalyst effectiveness factor throughout the reactor, while its impact on carbon monoxide conversion, hydrogen partial pressure, and the temperature profile is especially pronounced near the reactor inlet. Additionally, results showed that sweep gas use accelerates the reaction and aids hydrogen permeation. Finally, CO conversion in the membrane reactor reached 1.3 times that of a conventional fixed-bed reactor.
- 13 January 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 20 (14) , 1584-1596
Assessment of improved models for predicting PV module temperature and their electrical performance in a semi-arid coastal region
The performance of photovoltaic (PV) modules is affected by the increase in their operating temperature. Accurate and reliable prediction of the PV module operating temperature (TM) is useful for evaluating their electrical performance and productivity and predicting the maximum power point under changing weather conditions. Based on experimental measurements collected during 1 year by a station placed in a semi-arid coastal region, in Morocco, several models are investigated to predict TM of polycrystalline PV modules. Starting from existing models in the literature, models have been developed to improve the accuracy of their prediction in the studied climate. The results show that irradiance (G) and ambient temperature are the most influential parameters for estimating the TM of the studied PV module. The accuracy of the prediction can be improved by introducing the effects of Vw and RH in the proposed models. In addition, using the physical parameter extraction results of the studied modules, equations are established to approximately predict their behavior as a function of TM and G. Taking into account the proposed TM models, these equations describing the physical parameter evolution can constitute an important basis for predicting PV module performance under real operating conditions.
- 13 January 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 20 (14) , 1584-1596
Assessment of improved models for predicting PV module temperature and their electrical performance in a semi-arid coastal region
The performance of photovoltaic (PV) modules is affected by the increase in their operating temperature. Accurate and reliable prediction of the PV module operating temperature (TM) is useful for evaluating their electrical performance and productivity and predicting the maximum power point under changing weather conditions. Based on experimental measurements collected during 1 year by a station placed in a semi-arid coastal region, in Morocco, several models are investigated to predict TM of polycrystalline PV modules. Starting from existing models in the literature, models have been developed to improve the accuracy of their prediction in the studied climate. The results show that irradiance (G) and ambient temperature are the most influential parameters for estimating the TM of the studied PV module. The accuracy of the prediction can be improved by introducing the effects of Vw and RH in the proposed models. In addition, using the physical parameter extraction results of the studied modules, equations are established to approximately predict their behavior as a function of TM and G. Taking into account the proposed TM models, these equations describing the physical parameter evolution can constitute an important basis for predicting PV module performance under real operating conditions.
- Open Access
- 4 March 2022
- Published by BCREC Publishing Group in Bulletin of Chemical Reaction Engineering & Catalysis
- Vol. 17 (2) , 304-321
Numerical Study of a Water Gas Shift Fixed Bed Reactor Operating at Low Pressures
Today, hydrogen has become one of the most promising clean energy. Several processes allow obtaining hydrogen, among them there is the Water Gas Shift (WGS) reaction. On an industrial scale, WGS reaction takes place at high pressure [25–35 bar]. At high pressure, the cost of the process rises due to the energy consumed by compression, and the reduction in the lifetime of the equipment and the catalyst. At low pressures, catalyst lifetime can reach many years and the energy cost is reduced. It is for this reason that we are interested in modelling and simulation of a WGS converter operating at low pressures close to atmospheric pressure. In this work, a numerical study was conducted in order to determine the conditions allowing good rector operating at low pressure. A number of drawbacks of the process were identified. These drawbacks are essentially the non-negligible pressure drops and the strong intraparticle diffusion resistances. The prediction of the concentrations and the reaction rate within the pellet showed that the active zone of the pellet is located near the particle surface. It has also been shown that the resistances to interfacial mass and heat transfer are insignificant. The study of pressure effect showed that the pressure increase reduces the required catalyst mass to achieve equilibrium. Finally, this work revealed that the decrease in temperature and the increase in the concentrations of the reactants by increasing their fluxes, make it possible to increase the effectiveness factor of the catalyst and the conversion of carbon monoxide. Copyright © 2022 by Authors, Published by BCREC Group. This is an open access article under the CC BY-SA License (https://creativecommons.org/licenses/by-sa/4.0).
- 4 March 2022
- Published by BCREC Publishing Group in Bulletin of Chemical Reaction Engineering & Catalysis
- Vol. 17 (2) , 304-321
Open AccessNumerical Study of a Water Gas Shift Fixed Bed Reactor Operating at Low Pressures
Today, hydrogen has become one of the most promising clean energy. Several processes allow obtaining hydrogen, among them there is the Water Gas Shift (WGS) reaction. On an industrial scale, WGS reaction takes place at high pressure [25–35 bar]. At high pressure, the cost of the process rises due to the energy consumed by compression, and the reduction in the lifetime of the equipment and the catalyst. At low pressures, catalyst lifetime can reach many years and the energy cost is reduced. It is for this reason that we are interested in modelling and simulation of a WGS converter operating at low pressures close to atmospheric pressure. In this work, a numerical study was conducted in order to determine the conditions allowing good rector operating at low pressure. A number of drawbacks of the process were identified. These drawbacks are essentially the non-negligible pressure drops and the strong intraparticle diffusion resistances. The prediction of the concentrations and the reaction rate within the pellet showed that the active zone of the pellet is located near the particle surface. It has also been shown that the resistances to interfacial mass and heat transfer are insignificant. The study of pressure effect showed that the pressure increase reduces the required catalyst mass to achieve equilibrium. Finally, this work revealed that the decrease in temperature and the increase in the concentrations of the reactants by increasing their fluxes, make it possible to increase the effectiveness factor of the catalyst and the conversion of carbon monoxide. Copyright © 2022 by Authors, Published by BCREC Group. This is an open access article under the CC BY-SA License (https://creativecommons.org/licenses/by-sa/4.0).