Wail El Bazi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wail El Bazi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Abderrahim El-Abidi
Laboratory of Materials, Processes, Environment and Quality (LMPEQ), National School of Applied Sciences of Safi, Cadi Ayyad University, Route Sidi Bouzid BP 63, 46000 Safi, Morocco
2 shared publications- Abderrahim El-Abidi
Laboratory of Materials, Processes, Environment, and Quality, the National School of Applied Sciences, Cadi Ayyad University (UCA) , Route Sidi Bouzid, BP 63, 46000 Safi
2 shared publications Mustapha Bideq
Laboratory of Materials, Processes, Environment and Quality (LMPEQ), National School of Applied Sciences of Safi, Cadi Ayyad University, Route Sidi Bouzid BP 63, 46000 Safi, Morocco
2 shared publicationsSaid Yadir
Laboratory of Materials, Processes, Environment and Quality (LMPEQ), National School of Applied Sciences of Safi, Cadi Ayyad University, Route Sidi Bouzid BP 63, 46000 Safi, Morocco
2 shared publications- Said Yadir
Laboratory of Materials, Processes, Environment and Quality (LMPEQ), National School of Applied Sciences of Safi, Cadi Ayyad University, Route Sidi Bouzid BP 63, 46000 Safi, Morocco
2 shared publications - Brahim Messnaoui
Laboratory of Materials, Processes, Environment and Quality (LMPEQ), National School of Applied Sciences of Safi, Cadi Ayyad University, Route Sidi Bouzid BP 63, 46000 Safi, Morocco
1 shared publication
Latest Publications
- Open Access
- 10 July 2025
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 14 (5) , 914-926
Advanced one-dimensional heterogeneous model for high temperature water gas shift membrane reactors
To predict the behavior of small-scale WGS membrane reactors, a new model based on the 1D heterogeneous approach was developed. Unlike most studies, which rely on 1D pseudo-homogeneous models—typically limited to reactors filled with small catalyst particles which are prone to misestimating catalytic effectiveness when larger catalyst grains are used in which mass transfer resistance is usually considered only within the dense membrane layer which a valid assumption only when this layer is thick, the proposed model adapts to a wide range of catalyst sizes and geometries and also accounts for resistance in the porous stainless steel support of the membrane. This makes it suitable when the dense layer is thin.Comparison with experimental data under various conditions validated the model’s ability to predict the behavior of reactors packed with large catalyst particles (Vgrain ≈ 169 mm³). Therefore, the developed 1D heterogeneous model accurately predicts membrane reactor behavior without resorting to more complex 2D models. Simulations highlighted the significant influence of particle geometry on the catalyst effectiveness factor throughout the reactor, while its impact on carbon monoxide conversion, hydrogen partial pressure, and the temperature profile is especially pronounced near the reactor inlet. Additionally, results showed that sweep gas use accelerates the reaction and aids hydrogen permeation. Finally, CO conversion in the membrane reactor reached 1.3 times that of a conventional fixed-bed reactor.
- 10 July 2025
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 14 (5) , 914-926
Open AccessAdvanced one-dimensional heterogeneous model for high temperature water gas shift membrane reactors
To predict the behavior of small-scale WGS membrane reactors, a new model based on the 1D heterogeneous approach was developed. Unlike most studies, which rely on 1D pseudo-homogeneous models—typically limited to reactors filled with small catalyst particles which are prone to misestimating catalytic effectiveness when larger catalyst grains are used in which mass transfer resistance is usually considered only within the dense membrane layer which a valid assumption only when this layer is thick, the proposed model adapts to a wide range of catalyst sizes and geometries and also accounts for resistance in the porous stainless steel support of the membrane. This makes it suitable when the dense layer is thin.Comparison with experimental data under various conditions validated the model’s ability to predict the behavior of reactors packed with large catalyst particles (Vgrain ≈ 169 mm³). Therefore, the developed 1D heterogeneous model accurately predicts membrane reactor behavior without resorting to more complex 2D models. Simulations highlighted the significant influence of particle geometry on the catalyst effectiveness factor throughout the reactor, while its impact on carbon monoxide conversion, hydrogen partial pressure, and the temperature profile is especially pronounced near the reactor inlet. Additionally, results showed that sweep gas use accelerates the reaction and aids hydrogen permeation. Finally, CO conversion in the membrane reactor reached 1.3 times that of a conventional fixed-bed reactor.
- Open Access
- 23 June 2024
- Published by BCREC Publishing Group in Bulletin of Chemical Reaction Engineering & Catalysis
- Vol. 19 (2) , 300-317
New Modeling Approaches for Ethylene Oxychlorination in Fluidized Bed Reactors: Industrial and Low Flow Rate Conditions
A simple model (Continuous Stirred-Tank Reactor) has been developed to predict the behavior of industrial ethylene oxychlorination fluidized beds operating in a turbulent regime. The approach showed good agreement both with results from industrial reactors and with those corresponding to the (Simple two phases-Plug bubble-Mixed flow emulsion approach) validated in the literature. For low flow rates, the use of the (Simple two phases - Plug bubble - Plug emulsion model) adapted to these conditions enabled us to highlight the location and extent of undesirable thermal hot spots for the process, and to propose actions to control them by acting on the temperature and/or on the feed gas flows. By comparing this model with the plug approach, the significant slowdown in ethylene conversion caused by resistance to mass transfer when feed flow rates are low is highlighted. Copyright © 2024 by Authors, Published by BCREC Publishing Group. This is an open access article under the CC BY-SA License (https://creativecommons.org/licenses/by-sa/4.0).
- 23 June 2024
- Published by BCREC Publishing Group in Bulletin of Chemical Reaction Engineering & Catalysis
- Vol. 19 (2) , 300-317
Open AccessNew Modeling Approaches for Ethylene Oxychlorination in Fluidized Bed Reactors: Industrial and Low Flow Rate Conditions
A simple model (Continuous Stirred-Tank Reactor) has been developed to predict the behavior of industrial ethylene oxychlorination fluidized beds operating in a turbulent regime. The approach showed good agreement both with results from industrial reactors and with those corresponding to the (Simple two phases-Plug bubble-Mixed flow emulsion approach) validated in the literature. For low flow rates, the use of the (Simple two phases - Plug bubble - Plug emulsion model) adapted to these conditions enabled us to highlight the location and extent of undesirable thermal hot spots for the process, and to propose actions to control them by acting on the temperature and/or on the feed gas flows. By comparing this model with the plug approach, the significant slowdown in ethylene conversion caused by resistance to mass transfer when feed flow rates are low is highlighted. Copyright © 2024 by Authors, Published by BCREC Publishing Group. This is an open access article under the CC BY-SA License (https://creativecommons.org/licenses/by-sa/4.0).
- 13 January 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 20 (14) , 1584-1596
Assessment of improved models for predicting PV module temperature and their electrical performance in a semi-arid coastal region
The performance of photovoltaic (PV) modules is affected by the increase in their operating temperature. Accurate and reliable prediction of the PV module operating temperature (TM) is useful for evaluating their electrical performance and productivity and predicting the maximum power point under changing weather conditions. Based on experimental measurements collected during 1 year by a station placed in a semi-arid coastal region, in Morocco, several models are investigated to predict TM of polycrystalline PV modules. Starting from existing models in the literature, models have been developed to improve the accuracy of their prediction in the studied climate. The results show that irradiance (G) and ambient temperature are the most influential parameters for estimating the TM of the studied PV module. The accuracy of the prediction can be improved by introducing the effects of Vw and RH in the proposed models. In addition, using the physical parameter extraction results of the studied modules, equations are established to approximately predict their behavior as a function of TM and G. Taking into account the proposed TM models, these equations describing the physical parameter evolution can constitute an important basis for predicting PV module performance under real operating conditions.
- 13 January 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 20 (14) , 1584-1596
Assessment of improved models for predicting PV module temperature and their electrical performance in a semi-arid coastal region
The performance of photovoltaic (PV) modules is affected by the increase in their operating temperature. Accurate and reliable prediction of the PV module operating temperature (TM) is useful for evaluating their electrical performance and productivity and predicting the maximum power point under changing weather conditions. Based on experimental measurements collected during 1 year by a station placed in a semi-arid coastal region, in Morocco, several models are investigated to predict TM of polycrystalline PV modules. Starting from existing models in the literature, models have been developed to improve the accuracy of their prediction in the studied climate. The results show that irradiance (G) and ambient temperature are the most influential parameters for estimating the TM of the studied PV module. The accuracy of the prediction can be improved by introducing the effects of Vw and RH in the proposed models. In addition, using the physical parameter extraction results of the studied modules, equations are established to approximately predict their behavior as a function of TM and G. Taking into account the proposed TM models, these equations describing the physical parameter evolution can constitute an important basis for predicting PV module performance under real operating conditions.