MKMunawar Nawab Karimi

Munawar Nawab Karimi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Munawar Nawab Karimi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimum insulation thickness for external building walls for different climate zone in India

    by Mohd Shahid, Munawar Nawab Karimi, Atul Kumar Mishra

    The current study used degree-day method to determine the optimum insulation thickness for different insulation materials. Some of the commonly used insulation materials available in the market are considered in the study. Materials used in the study are, fiberglass rigid, urethane rigid, fiberglass urethane, perlite, and extruded polystyrene. The cooling degree days were calculated using the base temperature varies from 18ºC to 26ºC for the four major cities like Mumbai, New Delhi, Kolkata, and Chennai of India. The study aims to analyze the effect of the number of cooling degree days and base temperature on insulation thickness and also determine the variation of annual cooling cost with the insulation thickness. The result shows that the optimum insulation thickness varies with the cooling degree days and is also influenced by the electricity rate and the cost of insulation material. Based on the result, it is found that optimum insulation thickness is affected by the thermal conductivity of the material, base temperature, CDD, material cost, and fuel cost. The result shows best suitable insulation materials for Delhi, Mumbai, Kolkata, and Chennai are urethane rigid, fiberglass urethane, urethane rigid, and fiberglass rigid respectively. The optimum insulation thicknesses vary between 1 and 12 cm for the different base temperatures and cities. Annual cooling cost per m2 is calculated for the base temperature 21 ºC and 24 ºC, and the result shows that fiberglass urethane has the lowest annual cooling cost for different cities. Energy-saving varies with the thickness of the insulating materials apply on the wall. In addition with the help of insulation, energy can be saved up to 80% and achieve energy-efficient buildings.


  • Open Access

    Thermodynamic analysis of two evaporator vapor compression refrigeration system with low GWP refrigerants in automobiles

    by Salma Khatoon, Munawar Nawab Karimi

    Due to the growing demand for refrigerators and air conditioners in automobiles, there is a need for an innovative and efficient design to achieve both refrigeration and air conditioning. To address this, the present work has evaluated a two-evaporator vapor compression system to eliminate the requirement for separate refrigeration and air conditioning units. Theoretical energy and exergy performance assessment of the same is carried out along with the variation in the condenser and evaporators temperature. Various low GWP refrigerants such as R1234yf, HFO1336mzz(Z), R513A, and R450A are compared against high GWP R134a and R452A. The results reveal that maximum exergy efficiency and COP and lowest compressor power of 31.50%, 2.47, and 6.304 kW, respectively, are obtained with HFO1336mzz(Z). After HFO1336mzz(Z), R134a shows the highest exergy efficiency and COP of 30.56% and 2.41, respectively, and the lowest compressor power of 5.61kW. HFO1336mzz(Z) exhibits the optimum performance, whereas R452A shows the worst thermodynamic performance in the system. It is also found that the performance of R450, R513A, R450A, and R1234yf is approximately equivalent to each other. Moreover, component-wise exergy destruction analyses indicate that the efficiency of the compressor needs to be improved as the maximum destruction of 61.84–56.00% occurs in the compressor while the minimum exergy destruction of 0.42–0.54% occurs in the expansion valve. This study proposes the two-evaporator system for both refrigeration and air conditioning in automobiles. It is also found that R450A, R1234yf, R513A, and HFO1336mzz(Z) can be the potential alternative to R134a.


  • Optimization of energy transmittance through building envelope for hot dry climate

    by Mohd Shahid, Munawar Nawab Karimi

    Fenestrations of the buildings are playing an important role in the building’s energy efficiency for the tropical climate. The energy that comes from the glass window into the building can be restricted by providing shading on the windows. So, to provide the shading on the window, the most common way is fixed shade like overhang and fin. Shading devices are very helpful to control the SHGC and light transmittance through the fenestrations of the building. Most of the studies analyze the impact of WWR, shadings, and SHGC on a building’s energy demand but did not consider the combined effect of these parameters. By considering all the parameters of the building envelope in the analysis like WWR, orientation, shading devices, projection factor, and type of glass, the energy demand in the building can be significantly reduced. The goal of this paper is to analyze the variation of residential envelope transmittance value with the window-wall ratio, projection factor, and fixed shading devices and also to optimize the energy from building envelope elements in residential buildings using a statistical method, namely the Taguchi method. The transmittance of energy through the building envelope is calculated in 8 cardinal directions by providing shading with the fin and overhang. Based on the result, the optimum energy saving achieved by selecting the optimum combination of the process parameters for minimizing the energy from the building envelope is A1B1C3D2 i.e. window to wall ratio 7%, triple glazing type of glass used, shading with the overhang fin, and orientation in the west direction. The result shows the most significant factor among the selected parameter is the window to wall ratio. Also, by focusing on the building envelope parameters, an architectural designer may reduce the building energy demand significantly and offer more alternatives to achieve energy-efficient buildings.


  • Effect of circular perforated pin fin on heat transfer and fluid flow characteristics of rectangular microchannel heat sink

    by Mohammad Nawaz Khan, Munawwar Nawab Karimi, Mohammad Owais Qidwai

    In the present work, a numerical analysis has been performed to observe the heat transfer and fluid flow characteristics of the perforated pin fin microchannel heat sink. Six equidistant cylindrical pin fins with circular perforation at the center are entrenched at the base wall of the channel. This perforated pin fin can act as an extended surface and enhanced the heat transfer whereas the circular perforation may reduces the pressure drop and also influence the flow characteristics. The analysis has been done for the single-phase flow with Reynolds number ranges between 150 to 350 and the nondimensional diameter(α) of circular perforations considered in this study are 0.33, 0.5, 0.67 and 0.83. It is observed that the Nusslet number improves with the smallest perforation that is α = 0.33 and decreases as the diameter of perforation increases however the maximum value of overall thermal performance is associated with the perforation size of 0.5.


  • Refrigerant progression - an investigation into eco-sustainability with evolution and viability of fourth generation refrigerants

    by Salma Khatoon, Munawar Nawab Karimi

    Global warming is one of the most pressing issues the world is facing today. The refrigeration sector, one of the major contributors to global warming, needs to follow a methodological approach to address this issue. This paper evaluates the overall warming impact along with the thermodynamic performance of the different generations of refrigerants in the cascade refrigeration system. The main aim of this comparative study is to present a comprehensive outlook on the environmental impact of refrigerants. A different perspective on refrigerant selection to reduce global warming is also discussed. R600a, R290, R12, R22, R134a, R152a, R245fa, R1234yf, and R1234ze are used in the high-temperature circuit, while R32 is used in the low-temperature circuit. Exergy and energy analyses are done for thermodynamic performance, and total equivalent warming impact (TEWI) assessment is carried out to show global warming produced. While the refrigerant couple R152a/R32 shows the best thermodynamic performance with maximum COP, minimum exergy destruction, and maximum second law efficiency, R1234yf/R32 displays the worst thermodynamic performance. R12/R32 shows maximum TEWI while R290/R32 shows minimum TEWI. The first-generation refrigerants are found to be most environmentally friendly followed by the third and fourth. Fourth-generation refrigerants have the highest indirect emissions, which make their TEWI comparable to R134a. It is concluded that thermodynamic performance plays a significant role in reducing TEWI as indirect emissions account for the major part of the TEWI, and therefore, the global warming potential cannot be the only basis for refrigerant selection. This study suggests that first-generation refrigerants and R152a can be better alternatives.


  • ANALYSIS AND OPTIMIZATION OF VAPOR ABSORPTION GENERATOR-HEAT EXCHANGER USING KERN METHOD AND CFD

    by Salem Alabd Mohamed, Munawar Nawab Kari̇mİ

    The growing demand for new and eco-friendly energy resources has raised the need of sustainable sources or renewable energy for use in present era. A vapor absorption refrigeration system (VARS or VAS) is a closed loop refrigeration system which requires low heat for its functioning and, it is therefore, considered an eco-friendly solution. Since, generator is the main component of VAS which can significantly influence the efficacy of overall system, the current paper involves modeling and thermal analysis of generator using Computational Fluid Dynamics (CFD). The objective of this study is to optimize the heat transfer by changing baffle spacing of generator heat exchanger, running on a single effect LiBr/ water absorption cycle. For this purpose, hot water driven generator of 1ton capacity is taken. The simulation results of CFD were validated by comparing them with theoretical results. The overall design estimation and design technique that follows Birmingham Wire Gauge (BWG) and Tubular Exchangers Manufacturers Association (TEMA) standard are considered in this study. It was found from the analysis that the design model with smallest baffle spacing has the highest heat transfer coefficient. On reducing the baffle spacing from 137mm to 101mm, an increment of 48% in overall heat transfer coefficient was observed. Likewise, an increase in velocity by 36% and drop in static pressure by 27% were seen. Similar trend was observed in the theoretical results.