NCNathan Clements

Nathan Clements

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nathan Clements has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Erratum 3: Initial characterization of the ASPIRE 4 He + ion beam using EBT4 radiochromic film and Monte Carlo simulation

    by N. Clements, L. Dufort-Gagnon, A. Irving-Hughes, E. Yuan, M. Michielan, O. Masella, H. Klassen, C.R.J. Charles, M. Bazalova-Carter

  • Open Access

    Initial characterization of the ASPIRE 4 He + ion beam using EBT4 radiochromic film and Monte Carlo simulation

    by N. Clements, L. Dufort-Gagnon, A. Irving-Hughes, E. Yuan, M. Michielan, O. Masella, H. Klassen, C.R.J. Charles, M. Bazalova-Carter

    Experimental radiochromic film dosimetry of a helium-4 ion beam at subclinical energies (0.5–1.5 MeV/u) was performed at the newly commissioned ASPIRE facility at TRIUMF. Peeled GafChromic EBT4 films were irradiated with low-energy 4 He + ions, then scanned and analyzed to assess their suitability for spatial and quantitative dosimetry at these energies. To account for the film under-response caused by the high linear energy transfer (LET) of the beam, a correction factor was applied based on the mean LET calculated across the film's active layer using simulations. Monte Carlo simulations were performed with TOPAS to model dose deposition in the EBT4 film. Agreement between film measurements and Monte Carlo results was variable, largely limited by the lack of accurate delivered beam charge measurements. The experiments also revealed beam asymmetries and smaller-than-expected beam widths, attributed to suboptimal tuning of the accelerator chain. Overall, peeled EBT4 films were shown to be a practical tool for spatial beam characterization of helium-ion beams at subclinical energies. However, large uncertainties in delivered beam charge and measured doses beyond the range of EBT4 and the calibration curve used made accurate dosimetry impossible. This work motivates future studies at higher, more clinically relevant energies, where improved charge measurement and beam stability will be critical.

  • Open Access

    Development of a motorized iris collimator for kilovoltage x-ray radiotherapy

    by Olivia Masella, Will Canthal, Lane Braun, Alec Godfrey, Matthew Winn, Jacob Atkinson, Nathan Clements, Sandhya Rottoo, Joshua Chapman, Rolf Seuster, et al.

    Objective. To design and build a motorized iris collimator suitable for a novel low-cost kilovoltage dual-robot radiotherapy device and test its reliability and dosimetric capabilities. Approach. A 12-leaflet motorized iris collimator was designed and built weighing 4.8 kg, with 1 mm thick tungsten leaflets, a beam size range of 0.1 cm to 16.5 cm, and a leaflet speed up to 20 cm/s. Dosimetric tests were performed with EBT4 Gafchromic film at depths of 0 to 10 cm in a Solid Water phantom at a source to surface distance of 38 cm using a 225 kVp beam with 2 mm of Al filtration. A Monte Carlo (MC) model of the experimental setup was developed. Beam size was determined by full width at half maximum (FWHM) and penumbra values were calculated for both film and MC. The beam size was measured experimentally using digital radiographs acquired for sizes between 5 and 150 mm to evaluate the robustness of the system. Main results. The collimator demonstrated sharp profiles with penumbra values ≤1.2 mm at 2 cm depth. 2D dose distributions from film measurements found dose leakage within the designed 2% as well as a single offset leaflet as a result of machining tolerance. MC matched film measurements with surface central dose differences ≤1.1%, a beam penumbra match within 0.08 mm, and a FWHM match within 1.1 mm. The linearity and repeatability showed that beam sizes can be set with an accuracy of ≤1.25 mm for beams ≥1 cm. Significance. This work showcases a motorized iris collimator designed for a novel low-cost radiotherapy device, capable of delivering sharp dose distributions. An MC model was successfully developed and matched to film measurements, allowing for accurate simulation of radiotherapy delivery.


  • Open Access

    Beam collimation and filtration optimization for a novel orthovoltage radiotherapy system

    by Nathan Clements, Olivia Masella, Deae‐Eddine Krim, Lane Braun, Magdalena Bazalova‐Carter

    Background: The inaccessibility of clinical linear accelerators in low‐ and middle‐income countries creates a need for low‐cost alternatives. Kilovoltage (kV) x‐ray tubes have shown promise as a source that could meet this need. However, performing radiotherapy with a kV x‐ray tube has numerous difficulties, including high skin dose, rapid dose fall‐off, and low dose rates. These limitations create a need for highly effective beam collimation and filtration. Purpose: To improve the treatment potential of a novel kV x‐ray system by optimizing an iris collimator and beam filtration using Bayesian techniques and Monte Carlo (MC) simulations. Methods: The Kilovoltage Optimized AcceLerated Adaptive therapy system's current beam configuration consists of a 225 kVp x‐ray tube, a 12‐leaflet tungsten iris collimator, and a 0.1 mm copper filter. A Bayesian optimization was performed for the large and small focal spot sizes of the kV x‐ray tube source at 220 kVp using TopasOpt, an open‐source library for optimization in TOPAS. Collimator thickness, copper filter thickness, source‐to‐collimator distance (SCD), and source‐to‐surface distance (SSD) were the variables considered in the optimization. The objective function was designed to maximize the dose rate and the dose at a depth of 5 cm while minimizing the beam penumbra width and the out‐of‐field dose (OFD), all evaluated in a water phantom. Post‐optimization, the optimal beam configuration was simulated and compared to the existing configuration. Results: The optimal collimation setup consisted of 2.5 mm thick tungsten leaflets for the iris collimator and a 350 mm SSD for both focal spot sizes. The optimal copper filtration was 0.22 mm for the large focal spot and 0.15 mm for the small focal spot, with a SCD of 148.5 mm for the large focal spot and 125.8 mm for the small focal spot. For the large focal spot, the surface dose rate decreased by 9.4%, while the PDD at 5cm depth () increased by 7.7% compared to the existing iris collimator. Additionally, the surface beam penumbra width was reduced by 31.3%, and no significant changes in the OFD were observed. For the small focal spot, the surface dose rate for the new collimator increased by 3.7% and the increased by 5.3%, with no statistically significant changes in the beam penumbra width or OFD. Conclusion: The optimal beam collimation and filtration for both x‐ray tube focal spot sizes of a kV radiotherapy system was determined using Bayesian optimization and MC simulations and resulted in improved dose distributions.


  • Open Access

    Spatially fractionated radiotherapy with very high energy electron pencil beam scanning

    by Jade Fischer, Alexander Hart, Nicole Bedriová, Deae-Eddine Krim, Nathan Clements, Joseph Bateman, Pierre Korysko, Wilfrid Farabolini, Vilde Rieker, Roberto Corsini, et al.

    Objective. To evaluate spatially fractionated radiation therapy (SFRT) for very-high-energy electrons (VHEEs) delivered with pencil beam scanning. Approach. Radiochromic film was irradiated at the CERN linear electron accelerator for research using 194 MeV electrons with a step-and-shoot technique, moving films within a water tank. Peak-to-valley dose ratios (PVDRs), depths of convergence (PVDR ⩽ 1.1), peak doses, and valley doses assessed SFRT dose distribution quality. A Monte Carlo (MC) model of the pencil beams was developed using TOPAS and applied to a five-beam VHEE SFRT treatment for a canine glioma patient, compared to a clinical 6 MV VMAT plan. The plans were evaluated based on dose-volume histograms, mean dose, and maximum dose to the planning target volume (PTV) and organs at risks (OARs). Main results. Experimental PVDR values were maximized at 15.5 ± 0.1 at 12 mm depth for 5 mm spot spacing. A DOC of 76.5, 70.7, and 56.6 mm was found for 5, 4, and 3 mm beamlet spacings, respectively. MC simulations and experiments showed good agreement, with maximum relative dose differences of 2% in percentage depth dose curves and less than 3% in beam profiles. Simulated PVDR values reached 180 ± 4, potentially achievable with reduced leakage dose. VHEE SFRT plans for the canine glioma patient showed a decrease in mean dose (>16%) to OARs while increasing the PTV mean dose by up to 15%. Lowering beam energy enhanced PTV dose homogeneity and reduced OAR maximum doses. Significance. The presented work demonstrates that pencil beam scanning SFRT with VHEEs could treat deep-seated tumors such as head and neck cancer or lung lesions, though small beam size and leakage dose may limit the achievable PVDR.


  • Open Access

    Monte Carlo calculated absorbed‐dose energy dependence of EBT3 and EBT4 films for 5–200 MeV electrons and 100 keV–15 MeV photons

    by Nathan Clements, Magdalena Bazalova‐Carter

    Purpose: To use Monte Carlo simulations to study the absorbed‐dose energy dependence of GAFChromic EBT3 and EBT4 films for 5–200 MeV electron beams and 100 keV–15 MeV photon beams considering two film compositions: a previous EBT3 composition (Bekerat et al.) and the final composition of EBT3/current composition of EBT4 (Palmer et al.).Methods: A water phantom was simulated with films at 5–50 mm depth in 5 mm intervals. The water phantom was irradiated with flat, monoenergetic 5–200 MeV electron beams and 100 and 150 keV kilovoltage and 1–15 MeV megavoltage photon beams and the dose to the active layer of the films was scored. Simulations were rerun with the films defined as water to compare the absorbed‐dose response of film to water, .Results: For electrons, the Bekerat et al. composition had variations in of up to from 5 to 200 MeV. Similarly, the Palmer et al. composition had differences in up to from 5 to 200 MeV. For photons, varied up to and from 100 keV to 15 MeV for the Bekerat et al. and Palmer et al. compositions, respectively. The depth of films did not appear to significantly affect for photons at any energy and for electrons at energies 50 MeV. However, for 5 and 10 MeV electrons, decreases of up to in were seen due to stacked films and increased beam attenuation in films compared to water.Conclusions: The up to and variations in for electrons and photons, respectively, across the energies considered in this study indicate the importance of calibrating films with the energy intended for measurement. Additionally, this work emphasizes potential issues with stacking films to measure depth dose curves, particularly for electron beams with energies 10 MeV.


  • Open Access

    Mini-GRID radiotherapy on the CLEAR very-high-energy electron beamline: collimator optimization, film dosimetry, and Monte Carlo simulations

    by Nathan Clements, Nolan Esplen, Joseph Bateman, Cameron Robertson, Manjit Dosanjh, Pierre Korysko, Wilfrid Farabolini, Roberto Corsini, Magdalena Bazalova-Carter

    Objective. Spatially-fractionated radiotherapy (SFRT) delivered with a very-high-energy electron (VHEE) beam and a mini-GRID collimator was investigated to achieve synergistic normal tissue-sparing through spatial fractionation and the FLASH effect. Approach. A tungsten mini-GRID collimator for delivering VHEE SFRT was optimized using Monte Carlo (MC) simulations. Peak-to-valley dose ratios (PVDRs), depths of convergence (DoCs, PVDR ≤ 1.1), and peak and valley doses in a water phantom from a simulated 150 MeV VHEE source were evaluated. Collimator thickness, hole width, and septal width were varied to determine an optimal value for each parameter that maximized PVDR and DoC. The optimized collimator (20 mm thick rectangular prism with a 15 mm × 15 mm face with a 7 × 7 array of 0.5 mm holes separated by 1.1 mm septa) was 3D-printed and used for VHEE irradiations with the CERN linear electron accelerator for research beam. Open beam and mini-GRID irradiations were performed at 140, 175, and 200 MeV and dose was recorded with radiochromic films in a water tank. PVDR, central-axis (CAX) and valley dose rates and DoCs were evaluated. Main results. Films demonstrated peak and valley dose rates on the order of 100 s of MGy/s, which could promote FLASH-sparing effects. Across the three energies, PVDRs of 2–4 at 13 mm depth and DoCs between 39 and 47 mm were achieved. Open beam and mini-GRID MC simulations were run to replicate the film results at 200 MeV. For the mini-GRID irradiations, the film CAX dose was on average 15% higher, the film valley dose was 28% higher, and the film PVDR was 15% lower than calculated by MC. Significance. Ultimately, the PVDRs and DoCs were determined to be too low for a significant potential for SFRT tissue-sparing effects to be present, particularly at depth. Further beam delivery optimization and investigations of new means of spatial fractionation are warranted.


  • Open Access

    Monte Carlo optimization of a GRID collimator for preclinical megavoltage ultra-high dose rate spatially-fractionated radiation therapy

    by Nathan Clements, Magdalena Bazalova-Carter, Nolan Esplen

    Objective . A 2-dimensional pre-clinical SFRT (GRID) collimator was designed for use on the ultra-high dose rate (UHDR) 10 MV ARIEL beamline at TRIUMF. TOPAS Monte Carlo simulations were used to determine optimal collimator geometry with respect to various dosimetric quantities. Approach . The GRID-averaged peak-to-valley dose ratio (PVDR) and mean dose rate of the peaks were investigated with the intent of maximizing both values in a given design. The effects of collimator thickness, focus position, septal width, and hole width on these metrics were found by testing a range of values for each parameter on a cylindrical GRID collimator. For each tested collimator geometry, photon beams with energies of 10, 5, and 1 MV were transported through the collimator and dose rates were calculated at various depths in a water phantom located 1.0 cm from the collimator exit. Main results . In our optimization, hole width proved to be the only collimator parameter which increased both PVDR and peak dose rates. From the optimization results, it was determined that our optimized design would be one which achieves the maximum dose rate for a PVDR ≥ 5 at 10 MV. Ultimately, this was achieved using a collimator with a thickness of 75 mm, 0.8 mm septal and hole widths, and a focus position matched to the beam divergence. This optimized collimator maintained the PVDR of 5 in the phantom between water depths of 0–10 cm at 10 MV and had a mean peak dose rate of 3.06 ± 0.02 Gy s − 1 at 0–1 cm depth. Significance . We have investigated the impact of various GRID-collimator design parameters on the dose rate and spatial fractionation of 10, 5, and 1 MV photon beams. The optimized collimator design for the 10 MV ultra-high dose rate photon beam could become a useful tool for radiobiology studies synergizing the effects of ultra-high dose rate (FLASH) delivery and spatial fractionation.


  • Multi-contrast CT imaging using a high energy resolution CdTe detector and a CZT photon-counting detector

    by N. Clements, D. Richtsmeier, A. Hart, M. Bazalova-Carter

    Computed tomography (CT) imaging with high energy resolution detectors shows great promise in material decomposition and multi-contrast imaging. Multi-contrast imaging was studied by imaging a phantom with iodine (I), gadolinium (Gd), and gold (Au) solutions, and mixtures of the three using a cadmium telluride (CdTe) spectrometer with an energy resolution of 1% as well as with a cadmium zinc telluride (CZT) detector with an energy resolution of 13%. The phantom was imaged at 120 kVp and 1.1 mA with 7 mm of aluminum filtration. For the CdTe data collection, the phantom was imaged using a 0.2 mm diameter x-ray beam with 96 ten-second data acquisitions across the phantom at 45 rotation angles. For the CZT detector, we had 720 projections using a cone beam, and the six detector energy thresholds were set to 23, 33, 50, 64, 81, and 120 keV so that three thresholds corresponded to the K-edges of the contrast agents. Contrast agent isolation methods were then examined. K-edge subtraction and novel spectrometric algebraic image reconstruction (SAIR) were used for the CdTe data. K-edge subtraction alone was used for the CZT data. Linearity plots produced similar R 2 values and slopes for all three reconstruction methods. Comparing CdTe methods, SAIR offered less noise than CdTe K-edge subtraction and better geometric accuracy at low contrast concentrations. CdTe contrast agent images of I, Gd, and Au offered less noise and greater contrast than the CZT images, highlighting the benefits of high energy resolution CdTe detectors for possible use in pre-clinical or clinical CT imaging.