VMVictor Moncada

Victor Moncada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Victor Moncada has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cross‐device and cross‐modal arc detection: transfer learning between EAST visible and WEST infrared diagnostics

    by Zhongfang Guan, Erwan Grelier, Bin Zhang, Sebastien Vives, Baoguo Wang, Victor Moncada, Léo Dubus, Jinping Qian, Kedong Li, Jian Liu, et al.

    This work presents an engineering-oriented data processing and model training pipeline for Experimental Advanced Superconducting Tokamak (EAST) visible and (W) Environment in Steady-state Tokamak (WEST) infrared data, enabling a systematic study of cross-device and cross-modal electric arc detection. A lightweight convolutional neural network is adopted as a cross-device arc detection model, and joint training and transfer learning experiments are conducted on EAST visible (VIS) and WEST infrared (IR) data. Single‐modality baselines are first trained on EAST and WEST, then evaluated zero‐shot on the opposite device, followed by a comparison of frozen‐backbone and fine‐tuned transfer for VIS → IR and IR → VIS. The results show that models trained from scratch on each diagnostic channel already achieve high precision and recall for arc detection, whereas direct zero-shot cross-modal transfer drives the arc recall on the opposite domain almost to zero. In contrast, starting from the single-modality baselines and modestly fine tuning higher convolutional layers and the classification head on the target domain can significantly restore-cross device, cross-modal detection performance, with positive class precision and recall approaching or even surpassing the single-domain baselines. Class activation map analysis further indicates that, under fine-tuned and joint training configurations, the models consistently focus on the antenna, the arc, and its surrounding scattering region, supporting physically meaningful explanations and suggesting that cross-device, cross-modal training can capture arc related structures that generalize across devices while providing a lightweight, scalable route to reusing imaging-based diagnostic knowledge with reduced annotation and retuning effort. Given that machine protection is safety-critical and that imaging diagnostics are never identical across devices, the transferability demonstrated in this work is directly relevant to equipping next-generation tokamaks such as ITER and BEST with a reliable arc-detection capability before a large native training set becomes available. On a newly commissioned device, arc events are rare, sporadic and safety-relevant, so deferring detection until a sufficiently large native training corpus has accumulated would leave the machine unprotected during the early operational phase, when limited operating experience makes the associated risks most difficult to characterize; cross-machine and cross-modal transfer instead enables a new device to inherit a usable detection capability from the outset. Accordingly, the present work is intended not merely as a benchmark of cross-domain accuracy, but as evidence that scalable, transferable arc monitoring can constitute a machine-protection layer of future fusion reactors.

  • Open Access

    WEST advanced wall protection achievements toward long pulse operation

    by R. Mitteau, M.H. Aumeunier, L. Dubus, J. Gerardin, V. Gorse, E. Grelier, V. Moncada, S. Vives, X. Litaudon, M. Jakubowski, et al.

    Long pulse operation in magnetic fusion devices requires well controlled plasma power exhaust to the divertor & wall, and avoidance of wall hot spots that could evolve in wall damage. At WEST, 10 major plasma facing components are monitored using 10 series of temperature/power indicators, based on multiple diagnostic systems, among which the infrared viewing system is especially relevant. These indicators span from the most basic ones (temperatures, power and energy from deterministic models) to advanced processes using artificial intelligence acquired through machine learning. Some advanced processes do operate in real time, and feedback on power actuators through the plasma control system, providing active control toward remaining within the safe operational domain. Other advanced processes intervene as forensic tools post discharge to identify possible dangerous situations regarding the power loading to the wall, so that the discharge run plan is adjusted to avoid running into aggravating wall events. No critical wall power event happened during the campaigns C9 to C11 (2024–2025), totalling about 13 h of plasma, that would have affected the campaign plan. While it cannot be demonstrated that the active & intelligent wall protection enabled the new plasma duration record of 1337 s, the wall protection system as a whole plausibly contributed to obtaining these record durations by preventing wall hot spots to become critical during the campaigns.


  • Open Access

    Protection of the plasma facing components in the WEST tokamak, progress and development in view of ITER

    by M. Houry, M-H. Aumeunier, Y. Corre, X. Courtois, R. Mitteau, Th. Loarer, L. Dubus, E. Gauthier, J. Gerardin, V. Gorse, et al.

    The protection of the inner walls of magnetic confinement fusion research reactors is a crucial issue, particularly in this research context where plasma scenarios are explored to reach high power performance, thus leading to high temperature of the plasma facing components (PFCs), possibly close to their technological limitation. The aim is to protect the PFCs from damage during experimental campaigns, whilst enabling the expansion of the operational domain toward long duration and high power performances. With nearly 35 years of operation of Tore Supra and now WEST, CEA’s magnetic fusion research institute, the IRFM, has deployed a system combining thermal instrumentation, modeling of the heat transfer and photonic emission, signal processing and understanding of the physics of plasma-wall interaction to provide an optimized and controlled protection of the PFCs in metallic environment (with tungsten, bore, copper and stainless steel materials). In this context, the WEST Tokamak is a relevant Fusion facility capable of combining steady-state (Vloop ∼ 0) 1000 s long pulse operation with up to 6 MW m−2 on its divertor together with an advanced first wall protection system that could be deployed on ITER and future Fusion machines. The paper describes the wall protection system installed on WEST, highlighting its particular features and recent results.


  • Lossy compression of infrared videos in WEST (W Environment in Steady-state Tokamak)

    by Victor Moncada, Xavier Courtois, Leo Dubus, Raphael Mitteau

    During the 2019 C4 experimental campaign of the WEST (W Environment in Steady-state Tokamak) (France), the infrared diagnostic produced more than seven terabytes of uncompressed video data. Constraints on the computer infrastructure required for storage, backup, and especially offline access to infrared videos made the use of a compression algorithm mandatory. This paper proposes an innovative method to compress infrared videos with controlled temperature precision. This compression method is based on a controlled averaging of the video that maximizes the compression potential of standard lossless video codecs such as H264/AVC or HEVC. The combination of the loss introduction algorithm and the H264/AVC lossless video codec obtains the best compression ratio in the range of 8 to 41 with a maximum temperature error of 2 °C. This method also outperforms the JPEG-LS algorithm in terms of compression ratio and image quality for the same temperature precision.


  • Deep learning and image processing for the automated analysis of thermal events on the first wall and divertor of fusion reactors

    by Erwan Grelier, Raphaël Mitteau, Victor Moncada

    A multi-stage process that detects, tracks and classifies thermal events automatically using thermal imaging of the inside of fusion reactors is presented. The process relies on the Cascade R-CNN algorithm for the detection and classification and on the SORT algorithm for the tracking. The process is trained using a dataset of 325 thermal events distributed in seven classes, manually annotated from 20 infrared movies of the inside of the WEST tokamak. This dataset is created using user-friendly annotation tools, based on simple thresholding. The performance of the process is evaluated using modified indicators that emphasize the importance of the detection of the hottest zones of the hot spots. The modified mean average precision on a test dataset establishes at 27%.


  • Overview of the emissivity measurements performed in WEST: in situ and post-mortem observations

    by J. Gaspar, Y. Corre, F. Rigollet, M.-H. Aumeunier, E. Bernard, S. Brezinsek, X. Courtois, R. Dejarnac, M. Diez, L. Dubus, et al.

    This paper summarizes the emissivity measurements performed on the plasma-facing units (PFU) of the WEST lower divertor during the first phase of WEST running with a mix of actively cooled ITER-like PFUs made of bulk tungsten (W) and inertially cooled PFUs made of graphite with a coating of tungsten. In situ assessments of the emissivity and laboratory measurements after removing the W-coated graphite and ITER-grade PFUs from the WEST device are shown. The measurements exhibit a complex pattern with strong emissivity variation as a function of space and time mainly explained with the variation of magnetic equilibrium (strike point location) as well as the plasma performances during the experimental campaigns. The exposed ITER-grade PFU exhibits sharp spatial variation of the emissivity from 0.05 to 0.85 at a monoblock scale (12 mm) at the transition of the erosion (strike point location) and deposition (next to the strike point location) areas on the high-field side. On the low-field side, the emissivity varies from 0.12 at the strike point location, to 0.2 a few cm away in the low-field-side direction. This emissivity range after exposure is much higher than the emissivity variation of unexposed PFU with emissivity from 0.09 to 0.15. In situ observation performed on the W-coated graphite PFU shows a rapid evolution, typically a few pulses, of the emissivity in the inner and outer strike point location. The whole spatial distribution is discussed as well as its variation due to the plasma operation from the start-up of WEST to the removal of the W-coated graphite components.


  • Open Access

    Real-Time Detection of Overloads on the Plasma-Facing Components of Wendelstein 7-X

    by Aleix Puig Sitjes, Marcin Jakubowski, Dirk Naujoks, Yu Gao, Peter Drewelow, Holger Niemann, Joris Fellinger, Victor Moncada, Fabio Pisano, Chakib Belafdil, et al.

    Wendelstein 7-X (W7-X) is the leading experiment on the path of demonstrating that stellarators are a feasible concept for a future power plant. One of its major goals is to prove quasi-steady-state operation in a reactor-relevant parameter regime. The surveillance and protection of the water-cooled plasma-facing components (PFCs) against overheating is fundamental to guarantee a safe steady-state high-heat-flux operation. The system has to detect thermal events in real-time and timely interrupt operation if it detects a critical event. The fast reaction times required to prevent damage to the device make it imperative to automate fully the image analysis algorithms. During the past operational phases, W7-X was equipped with inertially cooled test divertor units and the system still required manual supervision. With the experience gained, we have designed a new real-time PFC protection system based on image processing techniques. It uses a precise registration of the entire field of view against the CAD model to determine the temperature limits and thermal properties of the different PFCs. Instead of reacting when the temperature limits are breached in certain regions of interest, the system predicts when an overload will occur based on a heat flux estimation, triggering the interlock system in advance to compensate for the system delay. To conclude, we present our research roadmap towards a feedback control system of thermal loads to prevent unnecessary plasma interruptions in long high-performance plasmas.