Catherine L. Cammarata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Catherine L. Cammarata has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Stephanie N. Taylor
Section of Infectious Diseases, Department of Medicine, Louisiana State University Health Sciences Center, New Orleans, LA
2 shared publications - Amanda Montano
Tricore Reference Laboratory
1 shared publication - Cameron Burgard
Tricore Reference Laboratory
1 shared publication - Catherine Fernandez
Becton, Dickinson and Company
1 shared publication - Celine Roger-Dalbert
Becton, Dickinson and Company
1 shared publication - Charles K. Cooper
Becton, Dickinson and Company
1 shared publication
Latest Publications
- Open Access
Incident Chlamydia trachomatis Infection in a High School Population
Prospective cohort studies of sexually transmitted infections (STIs) are logistically impractical owing to time and expenses. In schools, students are readily available for school-related follow-ups and monitoring. Capitalizing on the logistics that society already commits to ensure regular attendance of adolescents in school, a school-based STI screening in New Orleans made it possible to naturally observe the occurrence of chlamydia and to determine its incidence among 14–19-year-old adolescents. Among participants screened repeatedly, we calculated incidence rates, cumulative incidence, and incidence times. Male (n = 3820) and female (n = 3501) students were observed for 6251 and 5143 person-years, respectively, during which 415 boys and 610 girls acquired chlamydia. Incidence rates per 100 person-years were 6.6 cases for boys and 11.9 cases for girls. In multivariable analysis, the adjusted hazard ratio was 5.34 for boys and 3.68 for girls if the student tested positive for gonorrhea during follow-up, and 2.76 for boys and 1.59 for girls if at first participation the student tested positive for chlamydia, and it increased with age among boys but not among girls. In joinpoint trend analysis, the annual percentage change in the incidence rate was 6.6% for boys (95% CI: −1.2%, 15.1%) and 0.1% for girls (95% CI: −5.3%, 5.7%). Annual cumulative incidence was 5.5% among boys and 8.6% among girls. Median incidence time was 9.7 months for boys and 6.9 months for girls. Our findings can be used to refine assumptions in mathematical modeling and in cost analysis studies of C. trachomatis infection, and provide strong evidence in support of annual chlamydia screening for adolescent boys.
Open AccessIncident Chlamydia trachomatis Infection in a High School Population
Prospective cohort studies of sexually transmitted infections (STIs) are logistically impractical owing to time and expenses. In schools, students are readily available for school-related follow-ups and monitoring. Capitalizing on the logistics that society already commits to ensure regular attendance of adolescents in school, a school-based STI screening in New Orleans made it possible to naturally observe the occurrence of chlamydia and to determine its incidence among 14–19-year-old adolescents. Among participants screened repeatedly, we calculated incidence rates, cumulative incidence, and incidence times. Male (n = 3820) and female (n = 3501) students were observed for 6251 and 5143 person-years, respectively, during which 415 boys and 610 girls acquired chlamydia. Incidence rates per 100 person-years were 6.6 cases for boys and 11.9 cases for girls. In multivariable analysis, the adjusted hazard ratio was 5.34 for boys and 3.68 for girls if the student tested positive for gonorrhea during follow-up, and 2.76 for boys and 1.59 for girls if at first participation the student tested positive for chlamydia, and it increased with age among boys but not among girls. In joinpoint trend analysis, the annual percentage change in the incidence rate was 6.6% for boys (95% CI: −1.2%, 15.1%) and 0.1% for girls (95% CI: −5.3%, 5.7%). Annual cumulative incidence was 5.5% among boys and 8.6% among girls. Median incidence time was 9.7 months for boys and 6.9 months for girls. Our findings can be used to refine assumptions in mathematical modeling and in cost analysis studies of C. trachomatis infection, and provide strong evidence in support of annual chlamydia screening for adolescent boys.
- Open Access
Clinical evaluation of BD Veritor ™ SARS-CoV-2 point-of-care test performance compared to PCR-based testing and versus the Sofia ® 2 SARS Antigen point-of-care test
Objectives: The clinical performance of the BD Veritor™ System for Rapid Detection of SARS-CoV-2 antigen (Veritor), a chromatographic immunoassay that detects the SARS-CoV-2 nucleocapsid antigen as a point-of-care test, was evaluated on nasal specimens from individuals with COVID-19 symptoms. Methods and Materials: Two studies were completed to determine clinical performance. In the first study, nasal specimens and either nasopharyngeal or oropharyngeal specimens from 251 participants with COVID-19 symptoms (≤7 days from symptom onset [DSO]), ≥18 years of age, were utilized to compare Veritor with the Lyra ® SARS-CoV-2 PCR Assay (Lyra). In the second study, nasal specimens from 361 participants with COVID-19 symptoms (≤5 DSO), ≥18 years of age, were utilized to compare performance of Veritor to that of the Sofia ® 2 SARS Antigen FIA test (Sofia 2). Positive, negative, and overall percent agreement (PPA, NPA, and OPA, respectively) were the primary outcomes. Results: In study 1, PPA for Veritor, compared to Lyra, ranged from 81.8%-87.5% for 0-1 through 0-6 DSO ranges. In study 2, Veritor had a PPA, NPA, and OPA of 97.4%, 98.1%, and 98.1%, respectively, with Sofia 2. Discordant analysis showed one Lyra positive missed by Veritor and five Lyra positives missed by Sofia 2; one Veritor positive result was negative by Lyra. Conclusions: Veritor met FDA-EUA acceptance criteria for SARS-CoV-2 antigen testing (≥80% PPA point estimate) for the 0-5 and 0-6 DSO ranges. Veritor and Sofia 2 showed a high degree of agreement for SARS-CoV-2 detection. The Veritor test should facilitate rapid and reliable results for COVID-19 diagnosis utilizing easy-to-collect nasal swabs. Summary: The BD Veritor SARS-CoV-2 antigen test met FDA-EUA acceptance criteria for SARS-CoV-2 antigen testing for subjects with COVID-19 symptoms (0-5 days post-onset). BD Veritor and Quidel Sofia 2 antigen tests had good agreement for SARS-CoV-2 detection; discordant analysis favored Veritor.
Open AccessClinical evaluation of BD Veritor ™ SARS-CoV-2 point-of-care test performance compared to PCR-based testing and versus the Sofia ® 2 SARS Antigen point-of-care test
Objectives: The clinical performance of the BD Veritor™ System for Rapid Detection of SARS-CoV-2 antigen (Veritor), a chromatographic immunoassay that detects the SARS-CoV-2 nucleocapsid antigen as a point-of-care test, was evaluated on nasal specimens from individuals with COVID-19 symptoms. Methods and Materials: Two studies were completed to determine clinical performance. In the first study, nasal specimens and either nasopharyngeal or oropharyngeal specimens from 251 participants with COVID-19 symptoms (≤7 days from symptom onset [DSO]), ≥18 years of age, were utilized to compare Veritor with the Lyra ® SARS-CoV-2 PCR Assay (Lyra). In the second study, nasal specimens from 361 participants with COVID-19 symptoms (≤5 DSO), ≥18 years of age, were utilized to compare performance of Veritor to that of the Sofia ® 2 SARS Antigen FIA test (Sofia 2). Positive, negative, and overall percent agreement (PPA, NPA, and OPA, respectively) were the primary outcomes. Results: In study 1, PPA for Veritor, compared to Lyra, ranged from 81.8%-87.5% for 0-1 through 0-6 DSO ranges. In study 2, Veritor had a PPA, NPA, and OPA of 97.4%, 98.1%, and 98.1%, respectively, with Sofia 2. Discordant analysis showed one Lyra positive missed by Veritor and five Lyra positives missed by Sofia 2; one Veritor positive result was negative by Lyra. Conclusions: Veritor met FDA-EUA acceptance criteria for SARS-CoV-2 antigen testing (≥80% PPA point estimate) for the 0-5 and 0-6 DSO ranges. Veritor and Sofia 2 showed a high degree of agreement for SARS-CoV-2 detection. The Veritor test should facilitate rapid and reliable results for COVID-19 diagnosis utilizing easy-to-collect nasal swabs. Summary: The BD Veritor SARS-CoV-2 antigen test met FDA-EUA acceptance criteria for SARS-CoV-2 antigen testing for subjects with COVID-19 symptoms (0-5 days post-onset). BD Veritor and Quidel Sofia 2 antigen tests had good agreement for SARS-CoV-2 detection; discordant analysis favored Veritor.