KHKeiko Hirano

Keiko Hirano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Keiko Hirano has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Arata Ebihara

    Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan

    5 shared publications
  • Keiichiro Maki

    Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan

    5 shared publications
  • Satoshi Omori

    Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan

    5 shared publications
  • Shunsuke Kimura

    Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan

    5 shared publications
  • Takashi Okiji

    Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8549, Japan

    5 shared publications
  • Hayate Unno

    Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan

    2 shared publications

Latest Publications

  • Open Access

    Effect of Different Downward Loads and Rotational Speeds on the Removal of Gutta-Percha and Root Canal Sealer Using a Nickel-Titanium Rotary Gutta-Percha Removal System: An Ex Vivo Study

    by Koki Toyoda, Shunsuke Kimura, Keiichiro Maki, Satoshi Omori, Keiko Hirano, Arata Ebihara, Takashi Okiji

    Effective gutta-percha/sealer removal is essential for predictable nonsurgical endodontic retreatment, but the effects of key operational parameters on nickel–titanium rotary removal instruments remain insufficiently understood. This study aimed to examine how varying downward loads and rotational speeds affect the removal efficiency and torque/force generation of the HyFlex Remover. Sixty transparent straight resin canals filled with gutta-percha and AH Plus sealer were prepared using the HyFlex Remover at two rotational speeds (400 and 800 rpm) and three downward loads (2, 3, and 4 N; n = 10/group). The removal rate, calculated using micro-computed tomography, as well as removal time, maximum force, maximum torque, and cumulative torque were recorded and evaluated using two-way analysis of variance with Bonferroni correction (α = 0.05). The removal rate was consistently higher at 400 rpm than at 800 rpm (p < 0.001), while removal time and cumulative torque were greater at 400 rpm (p < 0.001). Maximum torque differed only between the 800-2 N and 800-4 N groups (p = 0.006). Maximum force increased with higher loads (p < 0.001), and at 3 N and 4 N, it was lower at 400 rpm than at 800 rpm (3 N: p = 0.039, 4 N: p < 0.001). Overall, lower downward loads reduced torque but prolonged working time, whereas higher rotational speeds shortened both working time and torque but decreased the removal rate.

  • Open Access

    Impact of Downward Load and Rotational Kinematics on Root Canal Instrumentation with a Heat-Treated Nickel–Titanium Rotary Instrument

    by Risako Yamamoto, Keiichiro Maki, Shunsuke Kimura, Satoshi Omori, Keiko Hirano, Arata Ebihara, Yoshio Yahata, Takashi Okiji

    This study analyzed how different downward loads and rotational kinematics influence NiTi rotary instrumentation outcomes. Heat-treated NiTi instruments were used to prepare extracted human single-rooted premolars with a moderate canal curvature. Instrumentation was performed using an automated endodontic instrumentation device with controlled downward loading and torque/force sensing, under different downward load settings (1, 2, and 3 N), employing either continuous rotation (CR) or optimum torque reverse (OTR) motion, which is a torque-sensitive reciprocation. Instrumentation was completed without instrument fracture or ledge formation in all six groups. OTR-3N specimens displayed a significantly lower upward force (i.e., screw-in force) than OTR-2N specimens (p < 0.05). OTR-1N specimens required a significantly longer instrumentation time than CR-1N specimens and the other OTR specimens (p < 0.05). At 1 mm from the apex, CR-2N specimens showed a significantly larger canal-centering ratio (i.e., larger deviation) than OTR-2N specimens (p < 0.05). Overall, applying a downward load of 2–3 N in OTR mode provided shaping efficiency similar to CR, but with a reduced screw-in force and enhanced canal-centering in the apical region, supporting the use of OTR as a promising alternative to CR for curved canal preparation using heat-treated NiTi instruments.

  • Open Access

    Impact of Varying Amplitudes of Upward and Downward Motion on the Torque/Force Generation, Canal-Centering Ability, and Cyclic Fatigue Resistance of Nickel–Titanium Reciprocating Instrument

    by Keiko Hirano, Shunsuke Kimura, Keiichiro Maki, Satoshi Omori, Arata Ebihara, Takashi Okiji

    The optimal amplitude of pecking motion during nickel–titanium rotary root canal instrumentation remains unclear. This study evaluated how different pecking amplitudes influence the force/torque generation, canal-centering ability, and cyclic fatigue resistance of the Reciproc Blue R25 instrument. Thirty J-shaped resin canals were instrumented with Reciproc Blue using automated instrumentation and a torque/force sensing device with an up-and-down speed of 50 mm/min and varying pecking amplitudes: Group S (1 s apically, 0.5 s coronally), Group M (2 s apically, 1 s coronally), and Group L (4 s apically, 2 s coronally) (n = 10 each). Force/torque were recorded, and canal-centering ratios were determined. In a dynamic cyclic fatigue test, the Reciproc Blue instruments were rotated in a curved metal canal with 1 mm or 3 mm back-and-forth motions (n = 10 each). Group L exhibited significantly greater maximum downward force and cumulative upward (screw-in) force than Group S (p < 0.05), but torque was not significantly different across groups. Groups M and L exhibited a significantly smaller canal-centering ratio than Group S (p < 0.05). Pecking at 3 mm led to a significantly longer time to fracture and shorter fragment lengths than 1 mm pecking (p < 0.05). In the Reciproc Blue instrumentation, higher pecking amplitude improved canal-centering ability and cyclic fatigue resistance while increasing upward and downward forces.


  • Open Access

    Mechanical Properties and Root Canal Shaping Ability of a Nickel–Titanium Rotary System for Minimally Invasive Endodontic Treatment: A Comparative In Vitro Study

    by Hayate Unno, Arata Ebihara, Keiko Hirano, Yuka Kasuga, Satoshi Omori, Taro Nakatsukasa, Shunsuke Kimura, Keiichiro Maki, Takashi Okiji

    Selection of an appropriate nickel–titanium (NiTi) rotary system is important for minimally invasive endodontic treatment, which aims to preserve as much root canal dentin as possible. This study aimed to evaluate selected mechanical properties and the root canal shaping ability of TruNatomy (TRN), a NiTi rotary system designed for minimally invasive endodontic shaping, in comparison with existing instruments: HyFlex EDM (HEDM), ProTaper Next (PTN), and WaveOne Gold (WOG). Load values measured with a cantilever bending test were ranked as TRN < HEDM < WOG < PTN (p < 0.05). A dynamic cyclic fatigue test revealed that the number of cycles to fracture was ranked as HEDM > WOG > TRN > PTN (p < 0.05). Torque and vertical force generated during instrumentation of J-shaped artificial resin canals were measured using an automated instrumentation device connected to a torque and vertical force measuring system; TRN exhibited smaller torque and vertical force values in most comparisons with the other instruments. The canal centering ratio for TRN was smaller than or comparable to that for the other instruments except for WOG at the apex level. Under the present experimental conditions, TRN showed higher flexibility and lower torque and vertical force values than the other instruments.


  • Open Access

    Effect of Rotational Modes on Torque/Force Generation and Canal Centering Ability during Rotary Root Canal Instrumentation with Differently Heat-Treated Nickel–Titanium Instruments

    by Satoshi Omori, Arata Ebihara, Keiko Hirano, Yuka Kasuga, Hayate Unno, Taro Nakatsukasa, Shunsuke Kimura, Keiichiro Maki, Takao Hanawa, Takashi Okiji

    This study aimed to evaluate how various rotational modes influence the torque/force production and shaping ability of ProTaper Universal (PTU; non-heat-treated) and ProTaper Gold (PTG; heat-treated) nickel–titanium instruments. J-shaped resin canals were instrumented with PTU or PTG using an automated instrumentation device operated with reciprocating rotation [150° clockwise and 30° counterclockwise (R150/30) or 240° clockwise and 120° counterclockwise (R240/120)], optimum torque reverse motion (OTR), or continuous rotation (CR) (n = 10 each). Maximum force and torque were recorded, and canal centering ratios were calculated. Statistical analysis was performed with two-way ANOVA and a Bonferroni test (α = 0.05). The results were considered with reference to previous studies on the microstructure of the instruments. The upward force generated by R240/120 and OTR was smaller than that generated by R150/30 and CR in PTG (p < 0.05). The clockwise torque produced by OTR was lower than that produced by R150/30 in PTU and R240/120 and CR in PTG (p < 0.05). R240/120 and OTR induced less canal deviation compared to CR in PTU at 0 mm from the apex (p < 0.05). In conclusion, R240/120 and OTR reduced the screw-in force in PTG and improved the canal centering ability in PTU, which may be associated with the heat treatment-induced microstructural difference of the two instruments.