Tao Wang
Tao Wang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Yu Zhang
4 shared publicationsYe-Jian Qian
3 shared publications- Zhao Yin
Institute of Engineering Thermophysics
3 shared publications Hua-Liang Zhang
2 shared publicationsLiang Qiu
2 shared publications- Peng Ren
School of Energy and Power Engineering, Beihang University, Beijing, China
2 shared publications
Latest Publications
- Open Access
- 24 October 2026
- Published by Elsevier in SSRN Electronic Journal
Optimal design of an aircraft-skin-integrated micro-pin-fin condenser for the water-enhanced turbofan
The water-enhanced turbofan (WET) is an emerging engine concept with the potential to substantially reduce fuel consumption and emissions. Its condenser is a key component that enables water condensation by cooling the core exhaust to induce condensation. Existing designs are constrained by small heat-transfer temperature differences, high mass and large pressure losses, limiting WET development. This study proposes a novel aircraft-skin-integrated micro-pin-fin condenser, with pin fins and hot-side passages located on the inner side of the aircraft skin. The configuration uses the high-speed freestream at cruise altitude to cool exhaust through the skin. Models for heat transfer and hot-side pressure loss are developed and validated against three-dimensional CFD simulations and experimental data. Aircraft transport efficiency is adopted as the ultimate design objective to balance condenser mass and hot-side pressure loss. Multi-objective optimization uses the elitist non-dominated sorting genetic algorithm II (NSGA-II). Three-dimensional simulations provide the air-side convective heat-transfer coefficient distribution over the aircraft skin. A simplified design adopts identical condenser units and neglects spatial non-uniformity in this coefficient. A subsequent zonal design divides the installation into six regions according to local air-side heat-transfer coefficients and optimizes the unit geometry and zonal flow allocation. The design result achieves a relative water condensation rate of 100.0%. The selected condenser attains a heat flux of 8.044 kW/m² and a heat transfer per unit mass of 13.683 kW/kg, with a maximum hot-side pressure-loss ratio of 1.708% and a total condenser of 302.154 kg per engine.
- 24 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimal design of an aircraft-skin-integrated micro-pin-fin condenser for the water-enhanced turbofan
The water-enhanced turbofan (WET) is an emerging engine concept with the potential to substantially reduce fuel consumption and emissions. Its condenser is a key component that enables water condensation by cooling the core exhaust to induce condensation. Existing designs are constrained by small heat-transfer temperature differences, high mass and large pressure losses, limiting WET development. This study proposes a novel aircraft-skin-integrated micro-pin-fin condenser, with pin fins and hot-side passages located on the inner side of the aircraft skin. The configuration uses the high-speed freestream at cruise altitude to cool exhaust through the skin. Models for heat transfer and hot-side pressure loss are developed and validated against three-dimensional CFD simulations and experimental data. Aircraft transport efficiency is adopted as the ultimate design objective to balance condenser mass and hot-side pressure loss. Multi-objective optimization uses the elitist non-dominated sorting genetic algorithm II (NSGA-II). Three-dimensional simulations provide the air-side convective heat-transfer coefficient distribution over the aircraft skin. A simplified design adopts identical condenser units and neglects spatial non-uniformity in this coefficient. A subsequent zonal design divides the installation into six regions according to local air-side heat-transfer coefficients and optimizes the unit geometry and zonal flow allocation. The design result achieves a relative water condensation rate of 100.0%. The selected condenser attains a heat flux of 8.044 kW/m² and a heat transfer per unit mass of 13.683 kW/kg, with a maximum hot-side pressure-loss ratio of 1.708% and a total condenser of 302.154 kg per engine.
- Open Access
- 11 October 2026
- Published by Elsevier in SSRN Electronic Journal
Optimization Design of an Exhaust-Duct-Integrated Helical-Coil Steam Generator
Water-enhanced turbofan (WET) engines have attracted increasing attention as a promising route for reducing fuel consumption and emissions. The steam generator is a key component of the WET, where exhaust waste heat is recovered to generate high-temperature and high-pressure steam. Its design must simultaneously improve compactness and reduce flow losses, heat-transfer temperature difference, and structural mass, which remains a critical challenge for WET engine implementation. In this study, an exhaust-duct-integrated helical-coil steam generator (EDI-HCSG) is proposed, and a one-dimensional thermal-hydraulic model is developed for its performance predictions and optimized designs. The model is validated by publicly available steam-generator data and CFD results, with errors in heat duty and outlet temperature within ±2.3% and ±3.91%, respectively. Based on the validated model, response surface methodology (RSM) and NSGA-II are combined to quantify the trade-off between steam-generator mass and hot-side flow loss under heat-duty and total-pressure-recovery constraints. The final design is selected from the Pareto front by further considering aircraft transport efficiency. The average heat-transfer temperature difference is 52.93 K, indicating relatively low heat-transfer irreversibility during exhaust heat recovery. The optimized EDI-HCSG achieves hot- and cold-side total pressure recovery coefficients of 0.91 and 0.931, respectively, and a mass-specific heat duty of 18.05 kW/kg. Compared with representative steam-generator designs from various application fields, the proposed EDI-HCSG demonstrates favorable performance in terms of compactness, mass-specific heat-transfer capacity, and other key metrics. These results indicate that the EDI-HCSG provides a feasible lightweight steam-generator configuration for WET engine exhaust heat recovery.
- 11 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimization Design of an Exhaust-Duct-Integrated Helical-Coil Steam Generator
Water-enhanced turbofan (WET) engines have attracted increasing attention as a promising route for reducing fuel consumption and emissions. The steam generator is a key component of the WET, where exhaust waste heat is recovered to generate high-temperature and high-pressure steam. Its design must simultaneously improve compactness and reduce flow losses, heat-transfer temperature difference, and structural mass, which remains a critical challenge for WET engine implementation. In this study, an exhaust-duct-integrated helical-coil steam generator (EDI-HCSG) is proposed, and a one-dimensional thermal-hydraulic model is developed for its performance predictions and optimized designs. The model is validated by publicly available steam-generator data and CFD results, with errors in heat duty and outlet temperature within ±2.3% and ±3.91%, respectively. Based on the validated model, response surface methodology (RSM) and NSGA-II are combined to quantify the trade-off between steam-generator mass and hot-side flow loss under heat-duty and total-pressure-recovery constraints. The final design is selected from the Pareto front by further considering aircraft transport efficiency. The average heat-transfer temperature difference is 52.93 K, indicating relatively low heat-transfer irreversibility during exhaust heat recovery. The optimized EDI-HCSG achieves hot- and cold-side total pressure recovery coefficients of 0.91 and 0.931, respectively, and a mass-specific heat duty of 18.05 kW/kg. Compared with representative steam-generator designs from various application fields, the proposed EDI-HCSG demonstrates favorable performance in terms of compactness, mass-specific heat-transfer capacity, and other key metrics. These results indicate that the EDI-HCSG provides a feasible lightweight steam-generator configuration for WET engine exhaust heat recovery.
The interaction between evaporation and chemistry on two-stage auto-ignition of an n-heptane droplet