Linda Bäcke
Linda Bäcke has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anton Jansson
Swerim AB, 164 40 Stockholm, Sweden
2 shared publications - Bevis Hutchinson
Swerim AB
2 shared publications - Johan Lönnqvist
Swerim AB, 164 40 Stockholm, Sweden
2 shared publications - Mikael Malmström
Swerim AB, Kista, Sweden
2 shared publications - David Lindell
Swerim AB, 164 40 Stockholm, Sweden
1 shared publication - Hans Sollander
SSAB EMEA AB, 781 84 Borlänge, Sweden
1 shared publication
Latest Publications
- Open Access
- 19 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (6) , 3901
Significance of Annealing Twins in Laser Ultrasonic Measurements of Grain Size in High-Strength Low-Alloy Steels
In this study, we demonstrate the significance of austenite annealing twin boundaries when calibrating laser ultrasonic measurements for gauging austenite grain size in situ during the thermomechanical processing of high-strength low-alloy steels. Simple calculations show how differences in twinning density can lead to errors in grain size measurements if twins are disregarded during calibration and the method is used for a broad range of steels. Conversely, when calibration is performed using alloys with a metastable austenite microstructure at room temperature, the same calibration is suitable for a broad range of HSLA steels, provided that annealing twins are taken into account. Since light optical microscopy does not allow the characterization of annealing twins in low-alloy steel, the verification of the laser ultrasonic results was conducted using the novel approach of comparing the twinned grain sizes obtained using the ultrasonic method in low-alloy steels with the austenite grain maps reconstructed from martensite orientation maps measured using electron backscatter diffraction. Finally, we show how differences in twinning density occur even for alloys with a roughly similar stacking fault energy, further highlighting the importance of annealing twins in the calibration of laser ultrasonic measurements for industrial use.
- 19 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (6) , 3901
Open AccessSignificance of Annealing Twins in Laser Ultrasonic Measurements of Grain Size in High-Strength Low-Alloy Steels
In this study, we demonstrate the significance of austenite annealing twin boundaries when calibrating laser ultrasonic measurements for gauging austenite grain size in situ during the thermomechanical processing of high-strength low-alloy steels. Simple calculations show how differences in twinning density can lead to errors in grain size measurements if twins are disregarded during calibration and the method is used for a broad range of steels. Conversely, when calibration is performed using alloys with a metastable austenite microstructure at room temperature, the same calibration is suitable for a broad range of HSLA steels, provided that annealing twins are taken into account. Since light optical microscopy does not allow the characterization of annealing twins in low-alloy steel, the verification of the laser ultrasonic results was conducted using the novel approach of comparing the twinned grain sizes obtained using the ultrasonic method in low-alloy steels with the austenite grain maps reconstructed from martensite orientation maps measured using electron backscatter diffraction. Finally, we show how differences in twinning density occur even for alloys with a roughly similar stacking fault energy, further highlighting the importance of annealing twins in the calibration of laser ultrasonic measurements for industrial use.
- Open Access
- 6 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 10048
Laser-Ultrasound-Based Grain Size Gauge for the Hot Strip Mill
The paper summarizes the creation of a robust online grain size gauge for a hot strip mill. A method and algorithm for calculating the grain size from the measured ultrasonic attenuation is presented. This new method is self-calibrating, does not rely on a geometrical reference sample and can cope with the effects of diffraction on the attenuation. The model is based on 52 quenched samples measured with more than 23,000 laser ultrasonics shots and has a correlation coefficient R2 of 0.8. Typical online laser ultrasonic measurements from the hot strip mill and the calculated grain size versus length are presented for a couple of steel strips.
- 6 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 10048
Open AccessLaser-Ultrasound-Based Grain Size Gauge for the Hot Strip Mill
The paper summarizes the creation of a robust online grain size gauge for a hot strip mill. A method and algorithm for calculating the grain size from the measured ultrasonic attenuation is presented. This new method is self-calibrating, does not rely on a geometrical reference sample and can cope with the effects of diffraction on the attenuation. The model is based on 52 quenched samples measured with more than 23,000 laser ultrasonics shots and has a correlation coefficient R2 of 0.8. Typical online laser ultrasonic measurements from the hot strip mill and the calculated grain size versus length are presented for a couple of steel strips.