Rune Sixten Grass
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rune Sixten Grass has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Erik Vilain Thomsen
Technical University of Denmark
3 shared publications - Jorgen Arendt Jensen
Center for Fast Ultrasound Imaging, Department of Health Technology, Technical University of Denmark, 2800 Lyngby, Denmark
3 shared publications - Borislav Gueorguiev Tomov
Department of Health Technology, Center for Fast Ultrasound Imaging, Technical University of Denmark, Kongens Lyngby, Denmark
2 shared publications - Kasper Fløng Pedersen
Department of Health Technology, MEMS Applied Sensors Group, Technical University of Denmark, Kongens Lyngby, Denmark
2 shared publications - Lasse Thurmann Jørgensen
Department of Health Technology, Center for Fast Ultrasound Imaging (CFU), Technical University of Denmark (DTU), Lyngby, Denmark
2 shared publications - Ali Salari
Department of Health Technology, Center for Fast Ultrasound Imaging, Technical University of Denmark, Kongens Lyngby, Denmark
1 shared publication
Latest Publications
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (3) , 251-271
512 + 512 Anodically Bonded Row-Column Addressed CMUT Array Fabrication and Characterization
In the pursuit of 3-D super-resolution ultrasound imaging, transducer arrays with apertures on the size of cm and sub 60 μm pitch are required, necessitating many elements and high-frequency operation. This work presents the fabrication process development and characterization of a λ/2 pitch 512+512 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array. The fabrication process was optimized by addressing key challenges in anodic bonding, specifically vertical short circuits, which severely limit the yield. Process optimization was performed to understand these shorts and a low-voltage 150 V anodic bonding solution was implemented to mitigate them. The complete process flow is detailed. Electrical characterization confirmed reliable CMUT operation with a 99% yield. To evaluate the acoustic performance, a 128+128 RCA CMUT array fabricated using the same process flow was integrated into a modular probe and characterized using a Vantage 256 scanner. Imaging performance of the RCA 128+128 CMUT probe was tested using a 3-D hydrogel scatter phantom with a grid of 205×205×80 μm3 targets and a wire phantom, demonstrating an axial and lateral resolution at −6 dB of 1.28λ (0.18 mm) and 1.55λ (0.22 mm).
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (3) , 251-271
512 + 512 Anodically Bonded Row-Column Addressed CMUT Array Fabrication and Characterization
In the pursuit of 3-D super-resolution ultrasound imaging, transducer arrays with apertures on the size of cm and sub 60 μm pitch are required, necessitating many elements and high-frequency operation. This work presents the fabrication process development and characterization of a λ/2 pitch 512+512 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array. The fabrication process was optimized by addressing key challenges in anodic bonding, specifically vertical short circuits, which severely limit the yield. Process optimization was performed to understand these shorts and a low-voltage 150 V anodic bonding solution was implemented to mitigate them. The complete process flow is detailed. Electrical characterization confirmed reliable CMUT operation with a 99% yield. To evaluate the acoustic performance, a 128+128 RCA CMUT array fabricated using the same process flow was integrated into a modular probe and characterized using a Vantage 256 scanner. Imaging performance of the RCA 128+128 CMUT probe was tested using a 3-D hydrogel scatter phantom with a grid of 205×205×80 μm3 targets and a wire phantom, demonstrating an axial and lateral resolution at −6 dB of 1.28λ (0.18 mm) and 1.55λ (0.22 mm).
- 16 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (3) , 367-378
Beamforming Through Encapsulation Layers: Efficient Time-of-Flight Modeling for High-Resolution Ultrasound Imaging
Medical ultrasound probes commonly employ a polymer encapsulation over the transducer for electrical protection and acoustic impedance matching. However, the speed of sound mismatch between the encapsulant and biological tissue can introduce Time Of Flight (TOF) errors that degrade beamforming coherence. This article presents a beamforming method that includes the encapsulating layer in the TOF calculation to improve image quality. Two TOF approximations, Direct Path (DP) and Normal Path (NP), are evaluated in terms of accuracy and computational cost. These are compared against the Homogeneous Direct Path (HDP) model, which neglects the encapsulant, and the exact Snell’s law Path (SP), computed using ray-tracing. Simulations and experiments are performed on a silicone encapsulated Row-Column Addressed (RCA) Capacitive Micromachined Ultrasound Transducer (CMUT) probe as a case study. DP and NP increased the processing time by only 1.2 × compared to HDP, while SP increased it by 46 ×. The measured standard deviation of the TOF error was reduced from 0.10 λ (HDP) to 0.06 λ (DP), and 0.05 λ (SP), ensuring high inter-channel coherence. Lateral resolution increased up to +47%, and contrast was enhanced by ≥ +2.1 dB using DP and SP models compared to HDP. The DP approximation achieved near-SP image quality, while maintaining HDP-level computational efficiency. The validity domain of NP and DP for any transducer was generalized using a critical F-number α. Overall, the proposed approximations provide a computationally efficient means to enhance resolution and contrast, establishing a practical solution for high-resolution realtime imaging.
- 16 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (3) , 367-378
Beamforming Through Encapsulation Layers: Efficient Time-of-Flight Modeling for High-Resolution Ultrasound Imaging
Medical ultrasound probes commonly employ a polymer encapsulation over the transducer for electrical protection and acoustic impedance matching. However, the speed of sound mismatch between the encapsulant and biological tissue can introduce Time Of Flight (TOF) errors that degrade beamforming coherence. This article presents a beamforming method that includes the encapsulating layer in the TOF calculation to improve image quality. Two TOF approximations, Direct Path (DP) and Normal Path (NP), are evaluated in terms of accuracy and computational cost. These are compared against the Homogeneous Direct Path (HDP) model, which neglects the encapsulant, and the exact Snell’s law Path (SP), computed using ray-tracing. Simulations and experiments are performed on a silicone encapsulated Row-Column Addressed (RCA) Capacitive Micromachined Ultrasound Transducer (CMUT) probe as a case study. DP and NP increased the processing time by only 1.2 × compared to HDP, while SP increased it by 46 ×. The measured standard deviation of the TOF error was reduced from 0.10 λ (HDP) to 0.06 λ (DP), and 0.05 λ (SP), ensuring high inter-channel coherence. Lateral resolution increased up to +47%, and contrast was enhanced by ≥ +2.1 dB using DP and SP models compared to HDP. The DP approximation achieved near-SP image quality, while maintaining HDP-level computational efficiency. The validity domain of NP and DP for any transducer was generalized using a critical F-number α. Overall, the proposed approximations provide a computationally efficient means to enhance resolution and contrast, establishing a practical solution for high-resolution realtime imaging.
- Open Access
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 2, 220-236
A Hand-Held 190+190 Row–Column Addressed CMUT Probe for Volumetric Imaging
This paper presents the design, fabrication, and characterization of a 190+190 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array integrated in a custom hand-held probe handle. The array has a designed 4.5 MHz center frequency in immersion and a pitch of$95~\mu $ m which corresponds to$\approx ~\lambda $ /4. The array has a$2.14\times2.14$ cm$^{2}$ footprint including an integrated apodization scheme to reduce ghost echoes when performing ultrasound imaging. The array was fabricated using a combination of fusion and anodic bonding, and a deposit, remove, etch, multistep (DREM) etch to reduce substrate coupling and improve electrode conductivity. The transducer array was wire-bonded to a rigid-flex printed circuit board (PCB), encapsulated in room temperature vulcanizing (RTV) silicone polymer, electromagnetic interference (EMI) shielded, and mounted in a 3D-milled PPSU probe handle. The probe was characterized using the SARUS experimental scanner and 3D volumetric imaging was demonstrated on scatter and wire phantoms. The imaging depth was derived from tissue mimicking phantom measurements (0.5 dB MHz$^{-1} \text{cm}^{-1}$ attenuation) by estimating the SNR at varying depths. For a synthetic aperture imaging sequence with 96+96 emissions the imaging depth was 3.6 cm. The center frequency measured from the impulse response spectra in transmit and pulse-echo was 6.0 ± 0.9 MHz and 5.3 ± 0.4 MHz, and the corresponding relative bandwidths were 62.8 ± 4.5 % and 86.2 ± 10.4 %. The fabrication process showed clear improvement in relative receive sensitivity and transmit pressure uniformity compared to earlier silicon-on-insulator (SOI) based designs. However, at the same time it presented yield problems resulting in only around 55 % elements with a good response.- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 2, 220-236
Open AccessA Hand-Held 190+190 Row–Column Addressed CMUT Probe for Volumetric Imaging
This paper presents the design, fabrication, and characterization of a 190+190 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array integrated in a custom hand-held probe handle. The array has a designed 4.5 MHz center frequency in immersion and a pitch of$95~\mu $ m which corresponds to$\approx ~\lambda $ /4. The array has a$2.14\times2.14$ cm$^{2}$ footprint including an integrated apodization scheme to reduce ghost echoes when performing ultrasound imaging. The array was fabricated using a combination of fusion and anodic bonding, and a deposit, remove, etch, multistep (DREM) etch to reduce substrate coupling and improve electrode conductivity. The transducer array was wire-bonded to a rigid-flex printed circuit board (PCB), encapsulated in room temperature vulcanizing (RTV) silicone polymer, electromagnetic interference (EMI) shielded, and mounted in a 3D-milled PPSU probe handle. The probe was characterized using the SARUS experimental scanner and 3D volumetric imaging was demonstrated on scatter and wire phantoms. The imaging depth was derived from tissue mimicking phantom measurements (0.5 dB MHz$^{-1} \text{cm}^{-1}$ attenuation) by estimating the SNR at varying depths. For a synthetic aperture imaging sequence with 96+96 emissions the imaging depth was 3.6 cm. The center frequency measured from the impulse response spectra in transmit and pulse-echo was 6.0 ± 0.9 MHz and 5.3 ± 0.4 MHz, and the corresponding relative bandwidths were 62.8 ± 4.5 % and 86.2 ± 10.4 %. The fabrication process showed clear improvement in relative receive sensitivity and transmit pressure uniformity compared to earlier silicon-on-insulator (SOI) based designs. However, at the same time it presented yield problems resulting in only around 55 % elements with a good response.