A Hand-Held 190+190 Row–Column Addressed CMUT Probe for Volumetric Imaging
Authors:
- Rune Sixten GrassRGRune Sixten Grass
- Mathias EngholmMEMathias Engholm
- Andreas Spandet HavrelandAHAndreas Spandet Havreland
- Christopher BeersCBChristopher Beers
- Martin Lind OmmenMOMartin Lind Ommen
- Stine Lovholt Grue PedersenSPStine Lovholt Grue Pedersen
- Matthias Bo StuartMSMatthias Bo Stuart
- Mudabbir Tufail BhattiMBMudabbir Tufail Bhatti
- Borislav G. TomovBTBorislav G. Tomov
- Jorgen Arendt JensenJJJorgen Arendt Jensen
- Erik Vilain ThomsenETErik Vilain Thomsen
Open Access
- 10 October 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 2, 220-236
Abstract
This paper presents the design, fabrication, and characterization of a 190+190 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array integrated in a custom hand-held probe handle. The array has a designed 4.5 MHz center frequency in immersion and a pitch of $95~\mu $ m which corresponds to $\approx ~\lambda $ /4. The array has a $2.14\times2.14$ cm $^{2}$ footprint including an integrated apodization scheme to reduce ghost echoes when performing ultrasound imaging. The array was fabricated using a combination of fusion and anodic bonding, and a deposit, remove, etch, multistep (DREM) etch to reduce substrate coupling and improve electrode conductivity. The transducer array was wire-bonded to a rigid-flex printed circuit board (PCB), encapsulated in room temperature vulcanizing (RTV) silicone polymer, electromagnetic interference (EMI) shielded, and mounted in a 3D-milled PPSU probe handle. The probe was characterized using the SARUS experimental scanner and 3D volumetric imaging was demonstrated on scatter and wire phantoms. The imaging depth was derived from tissue mimicking phantom measurements (0.5 dB MHz $^{-1} \text{cm}^{-1}$ attenuation) by estimating the SNR at varying depths. For a synthetic aperture imaging sequence with 96+96 emissions the imaging depth was 3.6 cm. The center frequency measured from the impulse response spectra in transmit and pulse-echo was 6.0 ± 0.9 MHz and 5.3 ± 0.4 MHz, and the corresponding relative bandwidths were 62.8 ± 4.5 % and 86.2 ± 10.4 %. The fabrication process showed clear improvement in relative receive sensitivity and transmit pressure uniformity compared to earlier silicon-on-insulator (SOI) based designs. However, at the same time it presented yield problems resulting in only around 55 % elements with a good response.
Keywords
Funding Information
- European Research Council Synergy grant (ERC 854796)
This publication has 70 references indexed in Scilit:
- Top-orthogonal-to-bottom-electrode (TOBE) CMUT arrays for 3-D ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Micromachining techniques in developing high-frequency piezoelectric composite ultrasonic array transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Array Beamforming2013
- SARUS: A synthetic aperture real-time ultrasound systemIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Capacitive micromachined ultrasonic transducers for medical imaging and therapyJournal of Micromechanics and Microengineering, 2011
- Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding technologyJournal of Microelectromechanical Systems, 2003
- FREE VIBRATIONS OF CIRCULAR PLATES COUPLED WITH LIQUIDS: REVISING THE LAMB PROBLEMJournal of Fluids and Structures, 1996
- PZT-epoxy piezoelectric transducers: A simplified fabrication procedureMaterials Research Bulletin, 1981
- Introduction to Solid State PhysicsAmerican Journal of Physics, 1957
- On the vibrations of an elastic plate in contact with waterProceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character, 1920