Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hamidreza Rezaee-Dehsorkh has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Ultra-Low Power Fixed-Window Level Crossing ADC for ECG Recording

    by Mahdi Ghasemi, Nassim Ravanshad, Hamidreza Rezaee-Dehsorkh

    In this paper, a novel fixed-window level-crossing analog-to-digital converter (LCADC) is proposed for the ECG monitoring application. The proposed circuit is implemented using fewer comparators and reference levels compared to the conventional structure, which results in a decrease in complexity and occupied silicon area. Also, the power consumption is reduced considerably by decreasing the activity of the comparator. Simulation results show a 5-fold reduction in activity by applying the standard ECG signals to the proposed structure. The proposed circuit is implemented in 0.18 μm CMOS technology using a 0.9 V supply voltage. Measurement results show a 5.9 nW power consumption and a 7.4-bit resolution. The circuit occupies a 0.05846 mm 2 silicon area. A typical level-crossing-based R-peak-detection algorithm is applied to the output samples of the LCADC, which shows the effectiveness of using this type of sampling.


  • Open Access

    Ultra-Low-Power Voice Activity Detection System Using Level-Crossing Sampling

    by Maral Faghani, Hamidreza Rezaee-Dehsorkh, Nassim Ravanshad, Hamed Aminzadeh

    This paper presents an ultra-low-power voice activity detection (VAD) system to discriminate speech from non-speech parts of audio signals. The proposed VAD system uses level-crossing sampling for voice activity detection. The useless samples in the non-speech parts of the signal are eliminated due to the activity-dependent nature of this sampling scheme. A 40 ms moving window with a 30 ms overlap is exploited as a feature extraction block, within which the output samples of the level-crossing analog-to-digital converter (LC-ADC) are counted as the feature. The only variable used to distinguish speech and non-speech segments in the audio input signal is the number of LC-ADC output samples within a time window. The proposed system achieves an average of 91.02% speech hit rate and 82.64% non-speech hit rate over 12 noise types at −5, 0, 5, and 10 dB signal-to-noise ratios (SNR) over the TIMIT database. The proposed system including LC-ADC, feature extraction, and classification circuits was designed in 0.18 µm CMOS technology. Post-layout simulation results show a power consumption of 394.6 nW with a silicon area of 0.044 mm2, which makes it suitable as an always-on device in an automatic speech recognition system.


  • A Low-Power Single-Path Bio-Impedance Measurement System Using an Analog-to-Digital Converter for I/Q Demodulation

    by Hamidreza Rezaee-Dehsorkh, Nassim Ravanshad, Ali Shamsaki, Maryam Rouhbakhsh Fakour, Peiman Aliparast

    In this paper, a low power single-path bio-impedance (Bio-Z) measurement system for early detection of acute myocardial ischemia is presented. The fully integrated system consists of a current source, an amplifier, and an analog-to-digital converter (ADC). The system utilizes the in-phase and quadrature (I/Q) components to obtain the real and imaginary parts of the tissue impedance. To achieve this goal, the ADC has been used to separate the I/Q components in addition to digitizing the samples. This can lead to power and silicon area reduction. The proposed circuit exploits the benefits of capacitively-coupled instrumentation amplifier, including inherent DC cancellation, low power, low noise, and high linearity and is implemented in 0.18 µm CMOS technology with a 1 V power supply. This system is designed and tested using a pseudo-sine 2 µA P-P current with a frequency of 1 kHz. The system can measure an input impedance that varies over a range from 0.03-7.5 kΩ with a resolution of 0.766 Ω rms while consuming 2 µW power from the supply. The operation of the system is also shown in the recording of impedance variation with respiration and heartbeat.


  • Calibration of SAR analog-to-digital converters for expanding the sampling rate range

    by Abbas Naghibzadeh, Hamidreza Rezaee-Dehsorkh, Nassim Ravanshad

    Successive approximation analog to digital converters (SARs) are widely used in electronic circuits because of good performance from the power consumption, resolution and speed points of view. Leakage currents and DAC incomplete settling limits the performance of these ADCs in low and high sampling rates respectively. This limits the range of the sampling rate in which a SAR ADC can be used and so the usage of this ADC in multi-purpose SoCs. In this paper a background calibration technique is used in order to improve the range of the SAR ADC sampling rate. It is shown that by utilizing this technique, the sampling rate can be improved in a range of from 50 kHz to 1 MHz for a 10-bit SAR ADC with ENOB > 9 bit which is designed and simulated in 90 nm CMOS technology with a 1.2 V supply voltage.

  • A fully-synchronous offset-insensitive level-crossing analog-to-digital converter

    by Nassim Ravanshad, Hamidreza Rezaee-Dehsorkh, Reza Lotfi

    A fully-synchronous offset-insensitive structure is proposed for implementing level-crossing analog-to-digital converters (LC-ADCs). The proposed structure is designed and implemented for high-precision compressed electrocardiogram (ECG) monitoring applications. Synchronous implementation leads to less implementation complexity compared to the conventional asynchronous implementations. Also the major source of error, viz. the difference in comparators offsets is eliminated which additionally leads to considerable saving in silicon area. Designing and simulating in a 0.18 μm CMOS technology, the LC-ADC achieves an ENOB of 8.45 bits and occupies 0.038 mm2 silicon area. The average sampling rate is about 120 S/s when applied to the whole MIT/BIH arrhythmia database. Simulation results show a power consumption of 81 nW with a 1.8 V supply voltage, by testing the ADC using Tape 100 of the MIT/BIH arrhythmia database.