Otto Kangasmaa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Otto Kangasmaa has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ilkka Laakso
Aalto University
4 shared publications Ilkka Laakso
Department of Electrical Engineering and Automation Aalto University Espoo Finland
2 shared publications- Janita Nissi
Department of Electrical Engineering and Automation and Aalto Neuroimaging, Aalto University, Espoo, Finland
2 shared publications Gernot Schmid
Seibersdorf Labor GmbH Seibersdorf Austria
1 shared publication- Juhani Kataja
Aalto University
1 shared publication - Nicolas Bouisset
Department of Medical Biophysics, University of Western Ontario
1 shared publication
Latest Publications
- Open Access
- 27 July 2026
- Published by Wiley in Bioelectromagnetics
- Vol. 47 (6) , e70066
Evaluating Human Perception Thresholds in Magnetic Stimulation Using Experimental Measurements and Modelling
This preregistered study investigated whether induced electric fields alone could predict human perception thresholds in magnetic stimulation. Using a figure‐of‐eight magnetic coil placed on the forearm, perception thresholds were collected from 24 healthy participants using the method of adjustment in 12 stimulation conditions. Subject‐fitted, anatomically realistic forearm models were constructed from a set of 10 MRI‐based models. Induced electric fields were computed using the finite element method with probabilistic tissue conductivities and post‐processed using spatial averaging and percentiles. Linear mixed‐effects modelling showed that the perception threshold was 32.2 V/m (SD between subjects 5.2 V/m) for a damped sinusoidal magnetic pulse with 83 s phase duration. This threshold value was determined by spatial averaging over a cube with a side length of 2 mm and taking the 99th percentile of the electric field within the modelled forearms. However, the induced electric field did not fully explain the perception threshold (adjusted = 0.48; permutation testing, p 0.001). We also conducted a supplementary modelling study, retrospectively analysing previous literature results to allow for direct comparison with our findings. These results showed that simplified calculations of the threshold electric field, obtained by modelling the forearm as a uniform cylinder, need to be scaled by a factor of 1.4 to align with the 99th percentile electric field calculated with anatomically realistic models. Both our experimental results and the modelling provide data to inform the refinement of safety guidelines.
- 27 July 2026
- Published by Wiley in Bioelectromagnetics
- Vol. 47 (6) , e70066
Open AccessEvaluating Human Perception Thresholds in Magnetic Stimulation Using Experimental Measurements and Modelling
This preregistered study investigated whether induced electric fields alone could predict human perception thresholds in magnetic stimulation. Using a figure‐of‐eight magnetic coil placed on the forearm, perception thresholds were collected from 24 healthy participants using the method of adjustment in 12 stimulation conditions. Subject‐fitted, anatomically realistic forearm models were constructed from a set of 10 MRI‐based models. Induced electric fields were computed using the finite element method with probabilistic tissue conductivities and post‐processed using spatial averaging and percentiles. Linear mixed‐effects modelling showed that the perception threshold was 32.2 V/m (SD between subjects 5.2 V/m) for a damped sinusoidal magnetic pulse with 83 s phase duration. This threshold value was determined by spatial averaging over a cube with a side length of 2 mm and taking the 99th percentile of the electric field within the modelled forearms. However, the induced electric field did not fully explain the perception threshold (adjusted = 0.48; permutation testing, p 0.001). We also conducted a supplementary modelling study, retrospectively analysing previous literature results to allow for direct comparison with our findings. These results showed that simplified calculations of the threshold electric field, obtained by modelling the forearm as a uniform cylinder, need to be scaled by a factor of 1.4 to align with the 99th percentile electric field calculated with anatomically realistic models. Both our experimental results and the modelling provide data to inform the refinement of safety guidelines.
- Open Access
- 24 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (19) , 195003
Alvar whole-body model: impact of muscle anisotropy on computational dosimetry
Objective. Computational electromagnetic dosimetry relies on accurate whole-body models to assess human exposure to electromagnetic fields. However, existing models lack anisotropic properties of tissues. This work addresses these limitations by introducing a whole-body model, Alvar, containing fully anisotropic skeletal muscles. Approach. The Alvar model has been constructed based on an anatomic atlas and developed specifically for computational dosimetry. Anisotropic models of skeletal muscles were created using Laplacian vector field simulations. Computational dosimetry was performed using anisotropic and isotropic versions of Alvar and six existing isotropic body models to estimate the electric fields induced due to exposure to spatially uniform magnetic and electric fields at 50 Hz. Main results. Modelling skeletal muscle anisotropy resulted in small variations in the 99th percentile induced electric field values (±5%) when the Alvar model was exposed to a magnetic field. When exposed to an external electric field, using anisotropic muscles systematically decreased the 99th percentile values by 13%. However, local differences in the induced electric field were larger (26%–29%) and even more significant inside muscle tissue (35%–39%). Significance. The results show that isotropic models are sufficient for calculating 99th percentile values when assessing whole-body exposure at power line frequencies but can lead to errors in local electric fields, especially in muscle tissue. This research contributes to the characterisation of uncertainty in low-frequency electromagnetic dosimetry, which can inform the development of human exposure limits.
- 24 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (19) , 195003
Open AccessAlvar whole-body model: impact of muscle anisotropy on computational dosimetry
Objective. Computational electromagnetic dosimetry relies on accurate whole-body models to assess human exposure to electromagnetic fields. However, existing models lack anisotropic properties of tissues. This work addresses these limitations by introducing a whole-body model, Alvar, containing fully anisotropic skeletal muscles. Approach. The Alvar model has been constructed based on an anatomic atlas and developed specifically for computational dosimetry. Anisotropic models of skeletal muscles were created using Laplacian vector field simulations. Computational dosimetry was performed using anisotropic and isotropic versions of Alvar and six existing isotropic body models to estimate the electric fields induced due to exposure to spatially uniform magnetic and electric fields at 50 Hz. Main results. Modelling skeletal muscle anisotropy resulted in small variations in the 99th percentile induced electric field values (±5%) when the Alvar model was exposed to a magnetic field. When exposed to an external electric field, using anisotropic muscles systematically decreased the 99th percentile values by 13%. However, local differences in the induced electric field were larger (26%–29%) and even more significant inside muscle tissue (35%–39%). Significance. The results show that isotropic models are sufficient for calculating 99th percentile values when assessing whole-body exposure at power line frequencies but can lead to errors in local electric fields, especially in muscle tissue. This research contributes to the characterisation of uncertainty in low-frequency electromagnetic dosimetry, which can inform the development of human exposure limits.
- Open Access
- 25 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1707-1714
Probing Vestibular Function With Frequency- Modulated Electrical Vestibular Stimulation
Electrical vestibular stimulation (EVS) is a non-invasive technique used to affect the vestibular system. It disturbs the sense of balance and evokes false sensations of movement by modulating the firing rate of vestibular afferents. This study used frequency-modulated EVS (FM-EVS) combined with center-of pressure (CoP) measurements to investigate the strength-frequency relationship of the stimulation and the evoked responses. CoP responses to FM-EVS were measured for ten subjects. Stimulus waveforms composed of linear chirps were compared to the evoked CoP responses, producing estimates of the highest frequencies at which EVS affected the CoP for stimulation currents of 0.75, 1.0 and 1.5 mA. Latency was calculated as the delay between the CoP response and stimulus. In situ electric field in the vestibular system was determined using fifteen high-resolution anatomical head models using the finite element method. CoP responses were evoked at up to 5.5 ± 1.1 Hz with 0.75 mA, 8.2 ± 1.1 Hz with 1.0 mA, and 10.5 ± 1.2 Hz with 1.5 mA. The vestibular electric field was 175 ± 23 mVm−1 per 1 mA current. The average latency of the response was 86 ± 17 ms. The results provide insight into the strength-frequency dependency for EVS-evoked motion responses with estimates for the in situ electric field strength, which can be used for the future development of human electromagnetic field exposure guidelines or the design of both EVS and transcranial electrical brain stimulation studies.
- 25 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1707-1714
Open AccessProbing Vestibular Function With Frequency- Modulated Electrical Vestibular Stimulation
Electrical vestibular stimulation (EVS) is a non-invasive technique used to affect the vestibular system. It disturbs the sense of balance and evokes false sensations of movement by modulating the firing rate of vestibular afferents. This study used frequency-modulated EVS (FM-EVS) combined with center-of pressure (CoP) measurements to investigate the strength-frequency relationship of the stimulation and the evoked responses. CoP responses to FM-EVS were measured for ten subjects. Stimulus waveforms composed of linear chirps were compared to the evoked CoP responses, producing estimates of the highest frequencies at which EVS affected the CoP for stimulation currents of 0.75, 1.0 and 1.5 mA. Latency was calculated as the delay between the CoP response and stimulus. In situ electric field in the vestibular system was determined using fifteen high-resolution anatomical head models using the finite element method. CoP responses were evoked at up to 5.5 ± 1.1 Hz with 0.75 mA, 8.2 ± 1.1 Hz with 1.0 mA, and 10.5 ± 1.2 Hz with 1.5 mA. The vestibular electric field was 175 ± 23 mVm−1 per 1 mA current. The average latency of the response was 86 ± 17 ms. The results provide insight into the strength-frequency dependency for EVS-evoked motion responses with estimates for the in situ electric field strength, which can be used for the future development of human electromagnetic field exposure guidelines or the design of both EVS and transcranial electrical brain stimulation studies.
- Open Access
- 18 January 2025
- Published by Wiley in Bioelectromagnetics
- Vol. 46 (1) , e22541
Estimating Human Fat and Muscle Conductivity From 100 Hz to 1 MHz Using Measurements and Modelling
The electrical conductivity of human tissues is a major source of uncertainty when modelling the interactions between electromagnetic fields and the human body. The aim of this study is to estimate human tissue conductivities in vivo over the low‐frequency range, from 30 Hz to 1 MHz. Noninvasive impedance measurements, medical imaging, and 3D surface scanning were performed on the forearms of ten volunteer test subjects. This data set was used to create subject‐specific forearm models, numerically solve an electrostatic forward problem, after which the tissue conductivities could be estimated by solving a probabilistic inverse problem. The electrical conductivity of skeletal muscle was found to be highly anisotropic at frequencies below 10 kHz, with conductivities of 0.13 (95% credible interval (CrI): 0.10–0.16) S/m perpendicular and 0.56 (CrI: 0.52–0.60) S/m parallel to the muscle fibre direction. This anisotropy decreased with increasing frequency with these values being 0.65 (CrI: 0.48–1.00) S/m and 0.78 (CrI: 0.72–0.85) S/m at 1 MHz. The conductivity of subcutaneous fat was found to be almost constant across the considered frequency range, with values of 0.21 (CrI: 0.12–0.31) S/m and 0.22 (CrI: 0.07–0.37) S/m at 10 kHz and 1 MHz, respectively. Our study provides robust uncertainty bounds for human tissue conductivity values, which are crucial in the computational assessment of human electromagnetic field exposure. Additionally, our findings are applicable to other fields of modelling such as medical stimulation or measurement technologies.
- 18 January 2025
- Published by Wiley in Bioelectromagnetics
- Vol. 46 (1) , e22541
Open AccessEstimating Human Fat and Muscle Conductivity From 100 Hz to 1 MHz Using Measurements and Modelling
The electrical conductivity of human tissues is a major source of uncertainty when modelling the interactions between electromagnetic fields and the human body. The aim of this study is to estimate human tissue conductivities in vivo over the low‐frequency range, from 30 Hz to 1 MHz. Noninvasive impedance measurements, medical imaging, and 3D surface scanning were performed on the forearms of ten volunteer test subjects. This data set was used to create subject‐specific forearm models, numerically solve an electrostatic forward problem, after which the tissue conductivities could be estimated by solving a probabilistic inverse problem. The electrical conductivity of skeletal muscle was found to be highly anisotropic at frequencies below 10 kHz, with conductivities of 0.13 (95% credible interval (CrI): 0.10–0.16) S/m perpendicular and 0.56 (CrI: 0.52–0.60) S/m parallel to the muscle fibre direction. This anisotropy decreased with increasing frequency with these values being 0.65 (CrI: 0.48–1.00) S/m and 0.78 (CrI: 0.72–0.85) S/m at 1 MHz. The conductivity of subcutaneous fat was found to be almost constant across the considered frequency range, with values of 0.21 (CrI: 0.12–0.31) S/m and 0.22 (CrI: 0.07–0.37) S/m at 10 kHz and 1 MHz, respectively. Our study provides robust uncertainty bounds for human tissue conductivity values, which are crucial in the computational assessment of human electromagnetic field exposure. Additionally, our findings are applicable to other fields of modelling such as medical stimulation or measurement technologies.
- Open Access
- 1 August 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 046038
In vivo and dosimetric investigation on electrical vestibular stimulation with frequency- and amplitude-modulated currents
Objective. Normal function of the vestibular system can be disturbed using a noninvasive technique called electrical vestibular stimulation (EVS), which alters a person’s sense of balance and causes false sensations of movement. EVS has been widely used to study the function of the vestibular system, and it has recently gained interest as a therapeutic tool to improve postural stability and help those suffering from vestibular dysfunction. Yet, understanding of how EVS stimulates the vestibular system, the current intensity needed to produce an effect and the frequencies at which it occurs have remained unclear. Approach. The effect of EVS on postural sway was examined in five participants using sinusoidal alternating current with time-varying amplitude from 0 to 1.5 mA and frequency from 0.1 to 10 Hz for three electrode configurations. Dosimetry of the current flow inside the head was conducted using anatomically realistic computational models created individually for each subject based on magnetic resonance imaging data. An estimate for the minimal field strength capable of affecting the vestibular system was calculated with the finite element method. Main results. Bipolar EVS at frequencies up to 10 Hz caused harmonic full-body swaying, and the frequency of the sway was the same as that of the stimulation current. The size of the sway was amplified by increasing the current intensity. Dosimetry modeling indicated that, for 0.2 mA current, the average electric field strength in the vestibular system was approximately 10–30 mV m−1, depending on the electrode montage. The size of the measured postural sway was proportional to the montage-specific electric field strength in the vestibular system. Significance. The results provide insight to EVS’s working mechanisms and improve its potential as a tool to study the sense of balance.
- 1 August 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 046038
Open AccessIn vivo and dosimetric investigation on electrical vestibular stimulation with frequency- and amplitude-modulated currents
Objective. Normal function of the vestibular system can be disturbed using a noninvasive technique called electrical vestibular stimulation (EVS), which alters a person’s sense of balance and causes false sensations of movement. EVS has been widely used to study the function of the vestibular system, and it has recently gained interest as a therapeutic tool to improve postural stability and help those suffering from vestibular dysfunction. Yet, understanding of how EVS stimulates the vestibular system, the current intensity needed to produce an effect and the frequencies at which it occurs have remained unclear. Approach. The effect of EVS on postural sway was examined in five participants using sinusoidal alternating current with time-varying amplitude from 0 to 1.5 mA and frequency from 0.1 to 10 Hz for three electrode configurations. Dosimetry of the current flow inside the head was conducted using anatomically realistic computational models created individually for each subject based on magnetic resonance imaging data. An estimate for the minimal field strength capable of affecting the vestibular system was calculated with the finite element method. Main results. Bipolar EVS at frequencies up to 10 Hz caused harmonic full-body swaying, and the frequency of the sway was the same as that of the stimulation current. The size of the sway was amplified by increasing the current intensity. Dosimetry modeling indicated that, for 0.2 mA current, the average electric field strength in the vestibular system was approximately 10–30 mV m−1, depending on the electrode montage. The size of the measured postural sway was proportional to the montage-specific electric field strength in the vestibular system. Significance. The results provide insight to EVS’s working mechanisms and improve its potential as a tool to study the sense of balance.
- Open Access
- 4 November 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (22) , 225002
Estimation method for the anisotropic electrical conductivity of in vivo human muscles and fat between 10 kHz and 1 MHz
Objective. In low frequency dosimetry the variability in the electrical conductivity values assigned to body model tissues represents a major source of uncertainty. The aim of this study is to propose a method for estimating the conductivity of human anisotropic skeletal muscle and fat in vivo in the frequency range from 10 kHz to 1 MHz. Approach. A method based on bounded electrical impedance tomography was used. Bioimpedance measurements were performed on the legs of ten subjects. Anatomically realistic models of the legs were then created using magnetic resonance images. The inverse problem of the tissue conductivities was solved using the finite element method. The results were validated using resampling techniques. These findings were also used to study the effects of muscle anisotropy on magnetic field exposure. Main results. The estimated conductivities for anisotropic muscle were found to be in good agreement with values found in existing literature and the anisotropy was shown to decrease with increasing frequency, with the ratio of lateral to longitudinal conductivity increasing from 37% to 64%. The conductivity of fat was found to be almost a constant 0.07 S m −1 in the frequency range considered. Significance. The proposed method was shown to be a viable option when estimating in vivo conductivity of human tissue. The results can be used in numerical dosimetry calculations or as limits in future investigations studying conductivity with bioimpedance measurements.
- 4 November 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (22) , 225002
Open AccessEstimation method for the anisotropic electrical conductivity of in vivo human muscles and fat between 10 kHz and 1 MHz
Objective. In low frequency dosimetry the variability in the electrical conductivity values assigned to body model tissues represents a major source of uncertainty. The aim of this study is to propose a method for estimating the conductivity of human anisotropic skeletal muscle and fat in vivo in the frequency range from 10 kHz to 1 MHz. Approach. A method based on bounded electrical impedance tomography was used. Bioimpedance measurements were performed on the legs of ten subjects. Anatomically realistic models of the legs were then created using magnetic resonance images. The inverse problem of the tissue conductivities was solved using the finite element method. The results were validated using resampling techniques. These findings were also used to study the effects of muscle anisotropy on magnetic field exposure. Main results. The estimated conductivities for anisotropic muscle were found to be in good agreement with values found in existing literature and the anisotropy was shown to decrease with increasing frequency, with the ratio of lateral to longitudinal conductivity increasing from 37% to 64%. The conductivity of fat was found to be almost a constant 0.07 S m −1 in the frequency range considered. Significance. The proposed method was shown to be a viable option when estimating in vivo conductivity of human tissue. The results can be used in numerical dosimetry calculations or as limits in future investigations studying conductivity with bioimpedance measurements.