SVSamira Vakili

Samira Vakili

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Samira Vakili has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparing Patellofemoral Kinematics Assessed With a Novel Muscle Actuator System and an Oxford Rig Using Noncadaveric Knees

    by Alexandre Galley, Samira Vakili, Ilya Borukhov, Brent Lanting, Stephen J. Piazza, Ryan Willing

    Total knee replacement (TKR) failure, low patient satisfaction and high revision surgery rates may stem from insufficient preclinical testing. Conventional joint motion simulators for preclinical testing of TKR implants manipulate a knee joint in force, displacement, or simulated muscle control. However, a rig capable of using all three control modes has yet to be described in literature. This study aimed to validate a novel platform, the muscle actuator system (MAS), that can generate gravity-dependent, quadriceps-controlled squatting motions representative of an Oxford rig knee simulator and is mounted onto a force/displacement-control-capable joint motion simulator. Synthetic knee joint phantoms were created that comprised revision TKR implants and key extensor and flexor mechanism analogues, but no ligaments. The combined system implemented a constant force vector acting from simulated hip-to-ankle coordinates, effectively replicating gravity as observed in an Oxford rig. Quadriceps forces and patellofemoral joint kinematics were measured to assess the performance of the MAS and these tests showed high levels of repeatability and reproducibility. Forces and kinematics measured at a nominal patellar tendon length, and with patella alta and baja, were compared against those measured under the same conditions using a conventional Oxford rig, the Pennsylvania State Knee Simulator (PSKS). There was disagreement in absolute kinematics and muscle forces, but similar trends resulting from changing prosthesis design or patellar tendon length.


  • In Vitro Assessment of Knee Joint Biomechanics Using a Virtual Anterior Cruciate Ligament Reconstruction

    by Samira Vakili, Thiago Vivacqua, Alan Getgood, Ryan Willing

    Understanding the biomechanical impact of injuries and reconstruction of the anterior cruciate ligament (ACL) is vital for improving surgical treatments that restore normal knee function. The purpose of this study was to develop a technique that enables parametric analysis of the effect of the ACL reconstruction (ACLR) in cadaver knees, by replacing its contributions with that of a specimen-specific virtual ACLR that can be enabled, disabled, or modified. Twelve ACLR reconstructed knees were mounted onto a motion simulator. In situ ACLR graft forces were measured using superposition, and these data were used to design specimen-specific virtual ACLRs that would yield the same ligament force-elongation behaviors. Tests were then repeated using the virtual ACLR in place of the real ACLR and following that in ACL deficient knee by disabling the virtual ACLR. In comparison to the ACL deficient state, the virtual ACLRs were able to restore knee stability to the same extent as real ACLRs. The average differences between the anterior tibial translation (ATT) of the virtual ACLR versus the real ACLR were +1.6 ± 0.9 mm (p = 0.4), +2.1 ± 0.4 mm (p = 0.4), and +1.0 ± 0.9 mm (p = 0.4) during Anterior drawer, Lachman and Pivot-shift tests, respectively, which is small in comparison to the full ATT range of motion (ROM) of these knees. Therefore, we conclude that a virtual ACLR can be used in place of real ACLR during biomechanical testing of cadaveric knees. This capability opens the door for future studies that can leverage parameterization of the ACLR for surgical design optimization.


  • Comparison of the Kinematics and Laxity of Total Knee Arthroplasty Bearing Designs Stabilized With Specimen-Specific Virtual Ligaments on a Joint Motion Simulator

    by Samira Vakili, Brent Lanting, Alan Getgood, Ryan Willing

    A variety of total knee arthroplasty (TKA) designs offer increased congruency bearing options, primarily to compensate for a loss of posterior cruciate ligament (PCL) function. However, their efficacy in providing sufficient stability under different circumstances requires further investigation. The preclinical testing of prosthesis components on joint motion simulators is useful for quantifying how design changes affect joint stability. However, this type of testing may not be clinically relevant because surrounding ligaments are either ignored or greatly simplified. This study aimed to assess the kinematics and stability of TKA joints during various motions using condylar-stabilized (CS) bearings without a PCL versus cruciate-retaining (CR) bearings with an intact PCL. TKA prosthetic components were tested on a joint motion simulator while being stabilized with five different sets of specimen-specific virtual ligament envelopes. In comparison to CR knees, CS knees without a PCL exhibited a greater amount of posterior tibial displacement laxity, with a mean increase of 2.7±2.1 mm (p = 0.03). Additionally, significant differences were observed in the anterior–posterior kinematics of the knee joint during activities of daily living (ADL) between the two designs. These results were consistent with previous cadaveric investigations, which indicated that CS knees without a PCL are less resistant to posterior tibial displacement than CR knees with one. This study employing virtual ligaments confirms previous findings that the raised anterior lip of some CS bearings may not completely compensate for the absence of the PCL; however, as both studies used reduced joint contact forces, the contributions of this design feature may be attenuated.


  • Development of Multibundle Virtual Ligaments to Simulate Knee Mechanics After Total Knee Arthroplasty

    by Samira Vakili, Brent Lanting, Alan Getgood, Ryan Willing

    Preclinical evaluation of total knee arthroplasty (TKA) components is essential to understanding their mechanical behavior and developing strategies for improving joint stability. While preclinical testing of TKA components has been useful in quantifying their effectiveness, such testing can be criticized for lacking clinical relevance, as the important contributions of surrounding soft tissues are either neglected or greatly simplified. The purpose of our study was to develop and determine if subject-specific virtual ligaments reproduce a similar behavior as native ligaments surrounding TKA joints. Six TKA knees were mounted to a motion simulator. Each was subjected to tests of anterior–posterior (AP), internal–external (IE), and varus–valgus (VV) laxity. The forces transmitted through major ligaments were measured using a sequential resection technique. By tuning the measured ligament forces and elongations to a generic nonlinear elastic ligament model, virtual ligaments were designed and used to simulate the soft tissue envelope around isolated TKA components. The average root-mean-square error (RMSE) between the laxity results of TKA joints with native versus virtual ligaments was 3.5 ± 1.8 mm during AP translation, 7.5 ± 4.2 deg during IE rotations, and 2.0 ± 1.2 deg during VV rotations. Interclass correlation coefficients (ICCs) indicated a good level of reliability for AP and IE laxity (0.85 and 0.84). To conclude, the advancement of virtual ligament envelopes as a more realistic representation of soft tissue constraint around TKA joints is a valuable approach for obtaining clinically relevant kinematics when testing TKA components on joint motion simulators.


  • Open Access

    Development of Multi-Bundle Virtual Ligaments to Simulate Knee Mechanics after Total Knee Arthroplasty

    by Samira Vakili, Brent Lanting, Alan Getgood, Ryan Willing

    Preclinical evaluation of total knee arthroplasty (TKA) components is essential to understanding their mechanical behavior and developing strategies for improving joint stability. While preclinical testing of TKA components has been useful in quantifying their effectiveness, such testing can be criticized for lacking clinical relevance, as the important contributions of surrounding soft tissues are either neglected or greatly simplified. The purpose of our study was to develop and determine if subject-specific virtual ligaments reproduce the same kinematics as native ligaments surrounding TKA joints. Five TKA knees were mounted to a motion simulator. Each was subjected to tests of anterior-posterior (AP), internal-external (IE), and varus-valgus (VV) laxity. The forces transmitted through major ligaments were measured using a sequential resection technique. By tuning the measured ligament forces and elongations to a generic non-linear elastic ligament model, virtual ligaments were designed and used to simulate the soft tissue envelope around isolated TKA components. The average root mean square error (RMSE) between the laxity results of TKA joints with native versus virtual ligaments was 2.9 mm during AP translation, 6.5° during IE rotations, and 2.0° during VV rotations, and there was no statistically significant difference between the results of both methods. Interclass correlation coefficients (ICCs) indicated a good level of reliability for AP and IE laxity (0.85 and 0.84). To conclude, a virtual ligament envelope around TKA joints can mimic natural knee behavior and is an effective method for the preclinical testing of TKA components.