HYHan-Jia Yang

Han-Jia Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Han-Jia Yang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Bin Yang

    Shanghai Jiao Tong University

    1 shared publication
  • Chunpeng Jiang

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China

    1 shared publication
  • Gen-Cai Shen

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China

    1 shared publication
  • Jingquan Liu

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University 1 , Shanghai 200240

    1 shared publication
  • Nan Zhao

    National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China

    1 shared publication
  • Zhuang-Zhuang Wang

    Department of Micro/Nano Electronics, National Key Lab of MicroNanofabrication Technology and the DCI Joint Team, Collaborative Innovation Center of IFSA, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China

    1 shared publication

Latest Publications

  • A MEMS-Based Wearable, Flexible Embedded High-Density Sensor With Self-Adhesive PEDOT:PSS Gel for HD-sEMG Monitoring

    by Nan Zhao, Han-Jia Yang, Gen-Cai Shen, Zhuang-Zhuang Wang, Chun-Peng Jiang, Bin Yang, Jing-Quan Liu

    The gold standard for dysphagia detection is the videofluoroscopic swallowing study (VFSS), which is expensive equipment, radioactive, and carries the risk of inadvertent aspiration of contrast agents. Surface electromyography (sEMG) provides low-cost, noninvasive access to electrophysiological information and accurate temporal resolution but does not provide good spatial resolution. Five-point and nine-point Laplacian methods (FPM and NPM) can improve spatial resolution. However, metallic interfaces have high impedance and motion artifacts, especially for skin with similar neck curvature, and suffer from modulus mismatch. We designed an embedded high-density sEMG (EWHD-sEMG) sensor and reported a self-adhesive poly(3,4-ethylenedioxythiophene)/poly(styrene-sulfonate) (PEDOT:PSS) gel that can withstand 250 g of adhesion with low modulus, low contact impedance (5 kΩ) and motion artifacts, and high signal-to-noise ratio (SNR, 26 dB). The sensor is made of biocompatible materials and is structured to wear comfortably. FPM and NPM improve the SNR and reduce the correlation from 1 to 0.01. In addition, the sensor can stretch 76.9% of the strain in one thousand repetitions and withstand multiple repetitions and long-term use of numerous sterilization methods. The sensor proposed in this thesis contributes to advancing and developing an sEMG-based clinical assessment of dysphagia.