Katsumi Kato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Katsumi Kato has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Hitoshi Okubo
Okubo Laboratory, Division of Energy Science, EcoTopia Science Institute, Nagoya University
3 shared publications- Hikaru Okubo
Department of Mechanical Engineering and Materials Science, Yokohama National University
2 shared publications - Masayuki Hikita
Kyushu Institute of Technology
2 shared publications - Naoki Hayakawa
Nagoya University
2 shared publications A. Ohashi
University of Nagoya, Nagoya, Japan
1 shared publication- Atsushi Sawada
Department of Electrical and Electronic Engineering, Tokyo Institute of Technology, 2-12-1, O-okayama, Meguro-ku, Tokyo 152–8552, Japan
1 shared publication
Latest Publications
- 27 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (5) , 1811-1817
Electric Field Grading and Discharge Inception Voltage Improvement on HVDC GIS/GIL Spacer With Permittivity and Conductivity Graded Materials (ε/σ-FGM)
Functionally graded materials (FGM) application with graded permittivity and conductivity is promising as an effective technique for electric field relaxation in SF6 gas around HVDC gas insulated switchgear (GIS)/gas insulated transmission line (GIL) spacers. To approach the practical application of FGM to HVDC GIS/GIL spacers, this article investigates the electric field reduction effect given by permittivity and conductivity graded materials ($\varepsilon /\sigma $ -FGM) based on actual measured permittivity ($\varepsilon $ ) characteristics of SrTiO3-filled epoxy composites and conductivity ($\sigma $ ) characteristics of SiC-filled epoxy composites. In addition, theoretical discharge inception voltage (TDIV) of$\varepsilon /\sigma $ -FGM spacer is calculated under standard lightning impulse (LI) voltage based on the volume–time theory. The results show that the$\varepsilon /\sigma $ -FGM spacer with grading to lower permittivity (GLP) ($\varepsilon _{r}$ from 12.7 to 4) containing 0–26.9-vol% SrTiO3-filled epoxy composite and U-shaped graded conductivity containing 5–10-vol% SiC-filled epoxy composite is effective for electric field relaxation under DC steady state (DC-SS) and LI voltage where both resistive and capacitive fields present. It is attributed to the higher$\varepsilon $ and$\sigma $ of FGM spacer near the HV conductor/spacer interface. TDIV under LI voltage is also estimated to be 26% higher at 0.5 MPa-abs, compared with the conventional spacer without$\varepsilon /\sigma $ grading.- 27 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (5) , 1811-1817
Electric Field Grading and Discharge Inception Voltage Improvement on HVDC GIS/GIL Spacer With Permittivity and Conductivity Graded Materials (ε/σ-FGM)
Functionally graded materials (FGM) application with graded permittivity and conductivity is promising as an effective technique for electric field relaxation in SF6 gas around HVDC gas insulated switchgear (GIS)/gas insulated transmission line (GIL) spacers. To approach the practical application of FGM to HVDC GIS/GIL spacers, this article investigates the electric field reduction effect given by permittivity and conductivity graded materials ($\varepsilon /\sigma $ -FGM) based on actual measured permittivity ($\varepsilon $ ) characteristics of SrTiO3-filled epoxy composites and conductivity ($\sigma $ ) characteristics of SiC-filled epoxy composites. In addition, theoretical discharge inception voltage (TDIV) of$\varepsilon /\sigma $ -FGM spacer is calculated under standard lightning impulse (LI) voltage based on the volume–time theory. The results show that the$\varepsilon /\sigma $ -FGM spacer with grading to lower permittivity (GLP) ($\varepsilon _{r}$ from 12.7 to 4) containing 0–26.9-vol% SrTiO3-filled epoxy composite and U-shaped graded conductivity containing 5–10-vol% SiC-filled epoxy composite is effective for electric field relaxation under DC steady state (DC-SS) and LI voltage where both resistive and capacitive fields present. It is attributed to the higher$\varepsilon $ and$\sigma $ of FGM spacer near the HV conductor/spacer interface. TDIV under LI voltage is also estimated to be 26% higher at 0.5 MPa-abs, compared with the conventional spacer without$\varepsilon /\sigma $ grading.- 11 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 14 (3) , 577-582
Breakdown conditioning characteristics of long gap electrodes in a vacuum
An improvement in dielectric strength is required in vacuum circuit breakers (VCBs) intended for use in higher voltage systems. In order to develop higher voltage VCBs, it is important to improve the dielectric strength in a vacuum based on consideration of the vacuum breakdown mechanism. Particularly for gaps longer than 10 mm, little is known about the breakdown mechanisms and their quantitative analyses in a vacuum. This paper discusses the breakdown conditioning characteristics of long gap electrodes, under a non-uniform electric field in a vacuum. We treat gap lengths of up to 50 mm in this paper. The conditioning characteristics are investigated under impulse voltage applications. A negative standard lightning impulse voltage was applied to rod-plane electrodes made of Cu-Cr and SUS304 for different tip radii and gap distances until the conditioning effect was completed. We observed illumination spots on electrodes at each breakdown during the conditioning process and calculated the corresponding breakdown field strengths. Experimental results revealed that the tendency of breakdowns associated with long gaps is different from that for the short gaps. As a result, we clarified that the breakdown field strengths are nearly constant at 110-120 kV/mm at the distances longer than 10 mm, and the breakdown field strength is at its maximum when the gap distance is about 5 mm.
- 11 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 14 (3) , 577-582
Breakdown conditioning characteristics of long gap electrodes in a vacuum
An improvement in dielectric strength is required in vacuum circuit breakers (VCBs) intended for use in higher voltage systems. In order to develop higher voltage VCBs, it is important to improve the dielectric strength in a vacuum based on consideration of the vacuum breakdown mechanism. Particularly for gaps longer than 10 mm, little is known about the breakdown mechanisms and their quantitative analyses in a vacuum. This paper discusses the breakdown conditioning characteristics of long gap electrodes, under a non-uniform electric field in a vacuum. We treat gap lengths of up to 50 mm in this paper. The conditioning characteristics are investigated under impulse voltage applications. A negative standard lightning impulse voltage was applied to rod-plane electrodes made of Cu-Cr and SUS304 for different tip radii and gap distances until the conditioning effect was completed. We observed illumination spots on electrodes at each breakdown during the conditioning process and calculated the corresponding breakdown field strengths. Experimental results revealed that the tendency of breakdowns associated with long gaps is different from that for the short gaps. As a result, we clarified that the breakdown field strengths are nearly constant at 110-120 kV/mm at the distances longer than 10 mm, and the breakdown field strength is at its maximum when the gap distance is about 5 mm.
- Open Access
- 1 January 2005
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 125 (12) , 1245-1251
Experimental Verification and Estimation for Insulation Performance in SF6 Gas around Triple Junctions Applied FGM (Functionally Graded Materials) under Lightning Impulse Conditions
- 1 January 2005
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 125 (12) , 1245-1251
Open AccessExperimental Verification and Estimation for Insulation Performance in SF6 Gas around Triple Junctions Applied FGM (Functionally Graded Materials) under Lightning Impulse Conditions
- 1 January 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 6 (4) , 464-468
Charging characteristics on dielectric surface by different charging processes in vacuum
- 1 January 1999
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 6 (4) , 464-468
Charging characteristics on dielectric surface by different charging processes in vacuum
- Open Access
- 1 January 1998
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 118 (9) , 1022-1027
Study on Temperature Dependence of electric Field Distribution in Transformer Oil/Pressboard Composite Insulation System by Optical Measurement of Electric Field
- 1 January 1998
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 118 (9) , 1022-1027
Open AccessStudy on Temperature Dependence of electric Field Distribution in Transformer Oil/Pressboard Composite Insulation System by Optical Measurement of Electric Field
- Open Access
- 1 January 1995
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 115 (11) , 1387-1392
Development of Electric Field Optimization Technique Using Neural Network
- 1 January 1995
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 115 (11) , 1387-1392
Open AccessDevelopment of Electric Field Optimization Technique Using Neural Network