Jianyuan Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianyuan Xu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Xin Lin
Shenyang University of Technology
3 shared publications - Cheng Jing
College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China
2 shared publications - Enming Bai
Electric Power Research Institute of Jilin Electric Power Co., Ltd. (State Grid), Changchun 130022, China
2 shared publications - Guixi Miao
State Grid, Henan Electric Power Company Anyang Power Supply Company, Henan, China
2 shared publications - Hong Dai
College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China
2 shared publications - Hui Ma
College of Electrical Engineering and New Energy, China Three Gorges University, Yichang, China
2 shared publications
Latest Publications
- 29 September 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (39) , 395502
Motion and adsorption: dynamic characteristics and spatial distribution of metallic particle in dry air DC-GIS
Metallic particles within gas-insulated switchgear (GIS) can distort electric fields, leading to gas discharge. Their adsorption onto insulator surface is particularly hazardous, as it can cause flashover and seriously compromise insulation safety. In this study, a transparent conductive scaled GIS busbar is used combined with an object detection model to investigate the motion and adsorption characteristics of linear metallic particle in dry air. Results show that, compared to SF 6 gas, the metallic particle in dry air exhibits higher velocity and a wider range of movement. However, it shows a lower probability of engaging in firefly motion and adsorbing onto insulator surfaces. Under positive polarity, the primary pattern is reciprocating movement. In contrast, under negative polarity, the particle exhibits prolonged swaying firefly motion on the conductor surface. Furthermore, increasing voltage enhances velocity and reduces the likelihood of firefly motion. Additionally, increasing the particle radius decreases firefly motion probability, whereas increasing length leads to the opposite result. Finally, the lifting position has no significant impact. This study supports suppressing metallic particle contamination and optimizing insulation design in dry air DC-GIS.
- 29 September 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (39) , 395502
Motion and adsorption: dynamic characteristics and spatial distribution of metallic particle in dry air DC-GIS
Metallic particles within gas-insulated switchgear (GIS) can distort electric fields, leading to gas discharge. Their adsorption onto insulator surface is particularly hazardous, as it can cause flashover and seriously compromise insulation safety. In this study, a transparent conductive scaled GIS busbar is used combined with an object detection model to investigate the motion and adsorption characteristics of linear metallic particle in dry air. Results show that, compared to SF 6 gas, the metallic particle in dry air exhibits higher velocity and a wider range of movement. However, it shows a lower probability of engaging in firefly motion and adsorbing onto insulator surfaces. Under positive polarity, the primary pattern is reciprocating movement. In contrast, under negative polarity, the particle exhibits prolonged swaying firefly motion on the conductor surface. Furthermore, increasing voltage enhances velocity and reduces the likelihood of firefly motion. Additionally, increasing the particle radius decreases firefly motion probability, whereas increasing length leads to the opposite result. Finally, the lifting position has no significant impact. This study supports suppressing metallic particle contamination and optimizing insulation design in dry air DC-GIS.
- Open Access
Study on Power Frequency Breakdown and Decomposition Characteristics of SF6/N2 Gas Mixture
The SF6/N2 gas mixture is a key eco-friendly alternative to SF6 in power equipment. However, its insulation and decomposition behaviors under realistic conditions of varying pressure and electric field non-uniformity remain insufficiently studied. This study establishes an experimental platform to systematically investigate the power–frequency breakdown and decomposition characteristics of a 3:7 SF6/N2 mixture. Breakdown tests and critical field strength calculations were conducted under different pressures and electric field uniformities, followed by gas composition analysis. Results demonstrate that the proposed critical breakdown field strength method effectively predicts the mixture’s breakdown voltage. Furthermore, a range of decomposition products, including NF3, SOF2, CO2, and C2F6, were identified, whose concentrations generally decreased with rising pressure. These findings provide valuable experimental data and a predictive tool for optimizing the insulation design and condition monitoring of SF6/N2 gas-insulated equipment.
Open AccessStudy on Power Frequency Breakdown and Decomposition Characteristics of SF6/N2 Gas Mixture
The SF6/N2 gas mixture is a key eco-friendly alternative to SF6 in power equipment. However, its insulation and decomposition behaviors under realistic conditions of varying pressure and electric field non-uniformity remain insufficiently studied. This study establishes an experimental platform to systematically investigate the power–frequency breakdown and decomposition characteristics of a 3:7 SF6/N2 mixture. Breakdown tests and critical field strength calculations were conducted under different pressures and electric field uniformities, followed by gas composition analysis. Results demonstrate that the proposed critical breakdown field strength method effectively predicts the mixture’s breakdown voltage. Furthermore, a range of decomposition products, including NF3, SOF2, CO2, and C2F6, were identified, whose concentrations generally decreased with rising pressure. These findings provide valuable experimental data and a predictive tool for optimizing the insulation design and condition monitoring of SF6/N2 gas-insulated equipment.
- Open Access
An Additional Damping Control Strategy for Grid-Forming Energy Storage to Address Low-Frequency Oscillation
Grid-forming (GFM) energy storage can be utilized as a backup power source for the power grid to ensure the security of the power grid. GFM energy storage can also enhance the strength of the power grid and improve its stability. However, the GFM energy storage inherits the characteristics of the synchronous generator. Low-frequency oscillations may occur in GFM energy storage, which affect the stable operation of the power system. This paper proposed an additional damping control strategy for GFM energy storage to address the low-frequency oscillation. Firstly, this paper builds the state-space small-signal mathematical model of the GFM energy storage grid-connected system to analyze the participation factors of the low-frequency oscillation mode and clarify the key control parameters affecting the GFM energy storage grid-connected system the low-frequency oscillation. Then, this paper proposed an additional damping control strategy to increase the damping ratio of the low-frequency oscillation mode and improve the stability of the GFM energy storage grid-connected system. Finally, semi-physical experiments verified the effectiveness of the proposed additional damping control strategy.
Open AccessAn Additional Damping Control Strategy for Grid-Forming Energy Storage to Address Low-Frequency Oscillation
Grid-forming (GFM) energy storage can be utilized as a backup power source for the power grid to ensure the security of the power grid. GFM energy storage can also enhance the strength of the power grid and improve its stability. However, the GFM energy storage inherits the characteristics of the synchronous generator. Low-frequency oscillations may occur in GFM energy storage, which affect the stable operation of the power system. This paper proposed an additional damping control strategy for GFM energy storage to address the low-frequency oscillation. Firstly, this paper builds the state-space small-signal mathematical model of the GFM energy storage grid-connected system to analyze the participation factors of the low-frequency oscillation mode and clarify the key control parameters affecting the GFM energy storage grid-connected system the low-frequency oscillation. Then, this paper proposed an additional damping control strategy to increase the damping ratio of the low-frequency oscillation mode and improve the stability of the GFM energy storage grid-connected system. Finally, semi-physical experiments verified the effectiveness of the proposed additional damping control strategy.
- 14 February 2025
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (4) , 2051-2064
Analysis of Dynamic Interaction and Oscillation Characteristics in LCC-VSC Combined System
- 14 February 2025
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 20 (4) , 2051-2064
Analysis of Dynamic Interaction and Oscillation Characteristics in LCC-VSC Combined System
- 7 December 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (4) , 2149-2158
Hierarchical Frequency Modulation Control Strategy for Large-Capacity AC/DC Hybrid Power System
- 7 December 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (4) , 2149-2158
Hierarchical Frequency Modulation Control Strategy for Large-Capacity AC/DC Hybrid Power System
- Open Access
- 3 September 2023
- Published by MDPI AG in Electronics
- Vol. 12 (17) , 3722
A Family of Five-Level Pseudo-Totem Pole Dual Boost Converters
In this paper, based on the pseudo-totem pole (PTP) circuit, a family of five-level PTP dual boost converters (PDBC) is proposed. A dual boost converter has some unique advantages, such as having no risk of bridge arm shoot-through and no problems related to switch body diode reverse recovery; thus, it has a good potential for applications. First, the derivation process, working principle, modulation and strategy of the topology are analyzed. Further, the number of power devices, switch voltages and current stress of the proposed topology is analyzed. Finally, a representative five-level PDBC experimental prototype is designed with AC input 220 V/50 Hz, DC output 400 V/1 kW, and peak efficiency of 98.27%. The experimental results show that the five-level PDBC proposed in this paper has higher efficiency and the correctness of its topology is verified.
- 3 September 2023
- Published by MDPI AG in Electronics
- Vol. 12 (17) , 3722
Open AccessA Family of Five-Level Pseudo-Totem Pole Dual Boost Converters
In this paper, based on the pseudo-totem pole (PTP) circuit, a family of five-level PTP dual boost converters (PDBC) is proposed. A dual boost converter has some unique advantages, such as having no risk of bridge arm shoot-through and no problems related to switch body diode reverse recovery; thus, it has a good potential for applications. First, the derivation process, working principle, modulation and strategy of the topology are analyzed. Further, the number of power devices, switch voltages and current stress of the proposed topology is analyzed. Finally, a representative five-level PDBC experimental prototype is designed with AC input 220 V/50 Hz, DC output 400 V/1 kW, and peak efficiency of 98.27%. The experimental results show that the five-level PDBC proposed in this paper has higher efficiency and the correctness of its topology is verified.
- Open Access
Time Estimation Algorithm of Single-Phase-to-Ground Fault Based on Two-Step Dimensionality Reduction
The fault detection time identified by relying on the over-voltage criterion of zero-sequence voltage often lags behind the actual occurrence time of ground faults, which may cause fault protection methods based on transient quantity principles to miss fault characteristics and lose their protection capability. To accurately estimate the time of occurrence of a single-phase-to-ground fault, this paper proposes a two-step dimensionality reduction algorithm for estimating the time of occurrence of a single-phase-to-ground fault in a distribution network. This algorithm constructs a filter based on Empirical Mode Decomposition (EMD) to establish a high-dimensional feature dataset based on the zero-sequence current of all feeders. After Principal Component Analysis and Hilbert Mapping Algorithm, the high-dimensional data are reduced to two dimensions to construct a two-dimensional feature dataset. The density-based clustering method is used to adaptively divide the data into two categories, fault data and non-fault data, so as to estimate the time of occurrence of the fault. The paper designs 11 sets of experiments including 7 common high-resistance grounding mediums to verify the accuracy of the fault time recognition of this algorithm. The accuracy of this algorithm is within 7.3 ms and it exhibits better detection performance compared to the threshold detection method.
Open AccessTime Estimation Algorithm of Single-Phase-to-Ground Fault Based on Two-Step Dimensionality Reduction
The fault detection time identified by relying on the over-voltage criterion of zero-sequence voltage often lags behind the actual occurrence time of ground faults, which may cause fault protection methods based on transient quantity principles to miss fault characteristics and lose their protection capability. To accurately estimate the time of occurrence of a single-phase-to-ground fault, this paper proposes a two-step dimensionality reduction algorithm for estimating the time of occurrence of a single-phase-to-ground fault in a distribution network. This algorithm constructs a filter based on Empirical Mode Decomposition (EMD) to establish a high-dimensional feature dataset based on the zero-sequence current of all feeders. After Principal Component Analysis and Hilbert Mapping Algorithm, the high-dimensional data are reduced to two dimensions to construct a two-dimensional feature dataset. The density-based clustering method is used to adaptively divide the data into two categories, fault data and non-fault data, so as to estimate the time of occurrence of the fault. The paper designs 11 sets of experiments including 7 common high-resistance grounding mediums to verify the accuracy of the fault time recognition of this algorithm. The accuracy of this algorithm is within 7.3 ms and it exhibits better detection performance compared to the threshold detection method.
- Open Access
- 26 May 2023
- Published by MDPI AG in Preprints.org
A Family of Five-Level Pseudo-Totem Pole Dual Boost Converters
In this paper, based on the pseudo-totem pole (PTP) circuit, a family of five-level PTP dual boost converters (PDBC) is proposed. Dual boost converter has some unique advantages such as no bridge arm shoot-through risk and no switch body diode reverse recovery problem, so that it has a good application prospect. Compared with conventional three-level PTP converters, PDBCs has higher power density, higher efficiency, and low voltage and current stress. The topological derivation process, working principle, modulation and strategy of the topology are analyzed firstly. Further, the number of power devices, the switches voltage and current stress of the proposed topology is analyzed. Finally, a representative five-level PDBC experimental prototype is designed with AC input 220V/50Hz, DC output 400V/1kW, and peak efficiency of 98.27%. The experimental results show that the five-level PDBC proposed in this paper has higher efficiency and verify the correctness of the topology.
- 26 May 2023
- Published by MDPI AG in Preprints.org
Open AccessA Family of Five-Level Pseudo-Totem Pole Dual Boost Converters
In this paper, based on the pseudo-totem pole (PTP) circuit, a family of five-level PTP dual boost converters (PDBC) is proposed. Dual boost converter has some unique advantages such as no bridge arm shoot-through risk and no switch body diode reverse recovery problem, so that it has a good application prospect. Compared with conventional three-level PTP converters, PDBCs has higher power density, higher efficiency, and low voltage and current stress. The topological derivation process, working principle, modulation and strategy of the topology are analyzed firstly. Further, the number of power devices, the switches voltage and current stress of the proposed topology is analyzed. Finally, a representative five-level PDBC experimental prototype is designed with AC input 220V/50Hz, DC output 400V/1kW, and peak efficiency of 98.27%. The experimental results show that the five-level PDBC proposed in this paper has higher efficiency and verify the correctness of the topology.