FDFederica Damonte

Federica Damonte

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Federica Damonte has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Continuous volitional control of a bionic leg supports diverse walking patterns in both agonist–antagonist muscle interface and bone-anchored prosthesis users

    by Federica Damonte, Lucas Avanci Gaudio, Jose Gonzalez-Vargas, Guillaume Durandau, Jennifer Ernst, Johan S Rietman, Ruud Leijendekkers, Herman van der Kooij, Massimo Sartori

    Myoelectric control paradigms have the potential to enable continuous volitional control of bionic limbs in various movement conditions. Although individuals with below knee amputations and an agonist–antagonist muscle interface (AMI) were proven to display a greater degree of continuous volitional control in bionic ankle-foot systems with respect to conventional socket-suspended prosthetic users, it remains unclear how myoelectric interfaces could translate to non-AMI prosthetic users with bone-anchored prostheses (BAP). This preliminary study proposes a human–machine interface (HMI) based on a neuromechanical model to enable volitional, continuous myoelectric control of a bionic leg in AMI and BAP users, walking across various speeds and ground inclinations. Differently from state of the art solutions, the proposed HMI is based on a digital twin of the intact leg, synthesizing the user’s phantom limb musculoskeletal function as controlled by muscle activations measured from the residuum. When embedded in a real-time framework, it enabled the participants to achieve volitional modulation of prosthesis peak plantar-dorsiflexion torques timing and amplitude during overground walking at three speeds (between 1.6 and 3.96 km/h), with case studies provided during calf-raises (30, 45, and 60 bpm) and ramp ascent walking (3 and 5% incline). Before prosthesis control tests, the participants underwent a 2-day gait training session. Results showed that all three subjects learned how to alter initial muscle activation patterns so that an average of 87% of peak activation timing fell within target ranges. The proposed neuromechanical modeling technology opens new avenues toward generalizable HMIs for the volitional control of active prostheses beyond set conditions and amputation types.


  • Open Access

    CEINMS-RT: An Open-Source Framework for the Continuous Neuro-Mechanical Model-Based Control of Wearable Robots

    by Massimo Sartori, Mohamed I. Refai, Lucas Avanci Gaudio, Christopher P. Cop, Donatella Simonetti, Federica Damonte, Matthew Hambly, David G. Lloyd, Claudio Pizzolato, Guillaume Durandau

    Human movement emerges from the interplay between nervous, muscular, and skeletal systems, interacting with the environment. Understanding these neuro-mechanical processes is crucial for developing volitional, neural control of wearable robots aimed at restoring mobility after neuromuscular injury. Movement neuro-mechanics is often studied via computer models of the neuromusculoskeletal system, which use static, dynamic optimization or reinforcement learning to estimate muscle activation patterns and resulting motor function. However, such approaches often fail at capturing the variability in multi-muscle recruitment and force generation across movements, anatomies, and conditions i.e., ageing or injury. Electromyography (EMG)-driven musculoskeletal modeling, or neuro-mechanical modeling, uses measured EMGs and joint angles for simulating musculotendon force and joint moment generation dynamics, with no assumptions on how muscles are neurally recruited. EMG-driven models have enabled task-agnostic, myoelectric, model-based controllers for devices ranging from bionic arms and legs to trunk, arm and leg exoskeletons. However, real-time myoelectric model-based controllers still remain largely proprietary, hindering their widespread use, progress and standardization. Here, we introduce CEINMS-RT, an open-source, EMG-driven modeling framework for real-time, myoelectric model-based control. Because CEINMS-RT computation time is well below the muscle electromechanical delay (< 3.1ms on a Raspberry Pi 2), it can estimate EMG-dependent joint moments in advance, an essential requirement for volitional robotic control, while maintaining accuracy comparable to offline models. This provides an open-source, mechanistic alternative to neural networks that directly map EMGs into joint moment or kinematic profiles, without modeling intermediate neuro-mechanical variables that are critical for understanding movement and human-robot interaction (e.g., musculotendon kinematics and impedance).


  • Open Access

    A Bionic Foot Controlled by a Synergy-Driven Neuromechanical Model Enables Walking at Various Speeds in Socket-Suspended and Bone-Anchored Prosthesis Users

    by F. Damonte, J. Gonzalez-Vargas, G. Durandau, J. S. Rietman, R. Leijendekkers, H. van der Kooij, M. Sartori

    Human locomotion adapts to different conditions, resulting in changes in gait parameters like speed, stride time, and length. Bionic limbs strive to mimic natural walking patterns, with speed adaptation being a key feature. Research shows that myoelectric bionic legs allow individuals with agonist-antagonist myoneural interface (AMI) amputations to control speed-adaptive walking. However, those with non-AMI amputations show difficulty generating consistent electromyography (EMG) signals. Therefore, we aim to create a human-machine interface that provides speed-adaptive biomimetic behavior without relying on EMGs. Steady-state locomotion can be modeled as the sequential recruitment of muscle groups during the gait cycle. To replicate this motor control, we created a control framework for a bionic foot using a neuromechanical model driven by synthetic muscle activations, replacing EMG recordings. We tested the controller on two individuals with transtibial amputations—one with a socket-suspended prosthesis and the other with a bone-anchored prosthesis. Muscle activation peaks fell within target ranges, leading to peak plantar-flexion torques at 49% of the gait cycle. The averaged model torques aligned with those from inverse dynamics on the intact side (RMSE = 0.52 ± 0.3 (Nm/Kg), r = 0.52 ± 0.4). The results show that the control system effectively modulates joint torques in timing and amplitude for two subjects across three walking speeds (0.55 to 1.1 m/s). Designed for steady-state walking, it can modulate torque during speed transitions. This first investigation aims to prove the feasibility of a personalized biomimetic control framework for bionic limbs without relying on EMGs, supporting walking at various speeds.


  • Open Access

    A bionic foot controlled by a synergy-driven neuromechanical model enables walking at various speeds in socket-suspended and bone-anchored prosthesis users

    by Federica Damonte, J Gonzalez-Vargas, G Durandau, J S Rietman, R Leijendekkers, H Van Der Kooij, M Sartori

    Human locomotion adapts to different conditions, resulting in changes in gait parameters like speed, stride time, and length. Bionic limbs strive to mimic natural walking patterns, with speed adaptation being a key feature. Research shows that myoelectric bionic legs allow individuals with agonist-antagonist myoneural interface (AMI) amputations to control speed-adaptive walking. However, those with non-AMI amputations show difficulty generating consistent electromyography (EMG) signals. Therefore, we aim to create a human-machine interface that provides speed-adaptive biomimetic behavior without relying on EMGs. Steady-state locomotion can be modeled as the sequential recruitment of muscle groups during the gait cycle. To replicate this motor control, we created a control framework for a bionic foot using a neuromechanical model driven by synthetic muscle activations, replacing EMG recordings. We tested the controller on two individuals with transtibial amputations-one with a socket-suspended prosthesis and the other with a bone-anchored prosthesis. Muscle activation peaks fell within target ranges, leading to peak plantar-flexion torques at 49% of the gait cycle. The averaged model torques aligned with those from inverse dynamics on the intact side (RMSE = 0.52 ± 0.3, r = 0.52 ± 0.4). The results show that the control system effectively modulates joint torques in timing and amplitude for two subjects across three walking speeds (0.55 to 1.1 m/s). Designed for steady-state walking, it can modulate torque during speed transitions. We propose this solution as a personalized biomimetic control framework for bionic limbs, supporting walking at various speeds for both AMI and non-AMI users.

  • Top Cited Papers
    Open Access

    A review of user needs to drive the development of lower limb prostheses

    by Sabina Manz, Romain Valette, Federica Damonte, Lucas Avanci Gaudio, Jose Gonzalez-Vargas, Massimo Sartori, Strahinja Dosen, Johan Rietman

    Background: The development of bionic legs has seen substantial improvements in the past years but people with lower-limb amputation still suffer from impairments in mobility (e.g., altered balance and gait control) due to significant limitations of the contemporary prostheses. Approaching the problem from a human-centered perspective by focusing on user-specific needs can allow identifying critical improvements that can increase the quality of life. While there are several reviews of user needs regarding upper limb prostheses, a comprehensive summary of such needs for those affected by lower limb loss does not exist.Methods: We have conducted a systematic review of the literature to extract important needs of the users of lower-limb prostheses. The review included 56 articles in which a need (desire, wish) was reported explicitly by the recruited people with lower limb amputation (N = 8149).Results: An exhaustive list of user needs was collected and subdivided into functional, psychological, cognitive, ergonomics, and other domain. Where appropriate, we have also briefly discussed the developments in prosthetic devices that are related to or could have an impact on those needs. In summary, the users would like to lead an independent life and reintegrate into society by coming back to work and participating in social and leisure activities. Efficient, versatile, and stable gait, but also support to other activities (e.g., sit to stand), contribute to safety and confidence, while appearance and comfort are important for the body image. However, the relation between specific needs, objective measures of performance, and overall satisfaction and quality of life is still an open question.Conclusions: Identifying user needs is a critical step for the development of new generation lower limb prostheses that aim to improve the quality of life of their users. However, this is not a simple task, as the needs interact with each other and depend on multiple factors (e.g., mobility level, age, gender), while evolving in time with the use of the device. Hence, novel assessment methods are required that can evaluate the impact of the system from a holistic perspective, capturing objective outcomes but also overall user experience and satisfaction in the relevant environment (daily life).