Rujin Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rujin Huang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Junyu Zhu
College of Science, Kunming University of Science and Technology, Kunming 650504, China
2 shared publications - Mingxing He
College of Science, Kunming University of Science and Technology, Kunming 650504, China
2 shared publications - Wenbin Zhang
Kunming University of Science and Technology, Kunming, China
2 shared publications - Chunguang Suo
Faculty of Science, Kunming University of Science and Technology, Kunming 650504, China
1 shared publication - Chunguang Suo
College of Science, Kunming University of Science and Technology, Kunming 650504, China
1 shared publication - Fangrong Zhou
Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
1 shared publication
Latest Publications
- Open Access
Transmission Line Voltage Measurement Utilizing a Calibrated Suspension Grounding Voltage Sensor
The accurate voltage measurement of distribution networks is of great significance in power dispatching and fault diagnosis. Voltage sensors based on the spatial electric field effect do not require grounding, which provides the possibility for the distributed measurement of transmission line voltages. However, the divider ratio of suspension grounding voltage sensors is affected by the height between the sensor and the ground, as well as the distance between the sensor and the telegraph pole. In this paper, a self-calibration method based on internal capacitance transformation is proposed to realize the on-line calibration of suspension grounding voltage sensors. The calibration is accomplished by switching different parameters in the conditioning circuit, and the calibration process does not require power failure or known input excitation. In addition, the impact of electric fields in the other two phases of three-phase transmission lines on measurement through simulation research is quantified in this paper. In order to reduce the impact of interference electric fields, an equipotential shielding structure is designed. The circuit topology and probe prototype have been developed and testing has been conducted in laboratory conditions; the experimental results show that the maximum relative error of voltage amplitude is 1.65%, and the phase relative error is 0.94%. The measurement accuracy is not limited by the height to ground or the distance to the telegraph pole. In addition, in the application of an equipotential shielding probe, the maximum deviation of measured voltage is 0.7% with and without interference electric fields.
Open AccessTransmission Line Voltage Measurement Utilizing a Calibrated Suspension Grounding Voltage Sensor
The accurate voltage measurement of distribution networks is of great significance in power dispatching and fault diagnosis. Voltage sensors based on the spatial electric field effect do not require grounding, which provides the possibility for the distributed measurement of transmission line voltages. However, the divider ratio of suspension grounding voltage sensors is affected by the height between the sensor and the ground, as well as the distance between the sensor and the telegraph pole. In this paper, a self-calibration method based on internal capacitance transformation is proposed to realize the on-line calibration of suspension grounding voltage sensors. The calibration is accomplished by switching different parameters in the conditioning circuit, and the calibration process does not require power failure or known input excitation. In addition, the impact of electric fields in the other two phases of three-phase transmission lines on measurement through simulation research is quantified in this paper. In order to reduce the impact of interference electric fields, an equipotential shielding structure is designed. The circuit topology and probe prototype have been developed and testing has been conducted in laboratory conditions; the experimental results show that the maximum relative error of voltage amplitude is 1.65%, and the phase relative error is 0.94%. The measurement accuracy is not limited by the height to ground or the distance to the telegraph pole. In addition, in the application of an equipotential shielding probe, the maximum deviation of measured voltage is 0.7% with and without interference electric fields.
- Open Access
Self-Calibration Sensor for Contactless Voltage Measurement Based on Dynamic Capacitance
Noncontact voltage measurement has the advantages of simple handling, high construction safety, and not being affected by line insulation. However, in practical measurement of noncontact voltage, sensor gain is affected by wire diameter, wire insulation material, and relative position deviation. At the same time, it is also subject to interference from interphase or peripheral coupling electric fields. This paper proposes a noncontact voltage measurement self-calibration method based on dynamic capacitance, which realizes self-calibration of sensor gain through unknown line voltage to be measured. Firstly, the basic principle of the self-calibration method for noncontact voltage measurement based on dynamic capacitance is introduced. Subsequently, the sensor model and parameters were optimized through error analysis and simulation research. Based on this, a sensor prototype and remote dynamic capacitance control unit that can shield against interference are developed. Finally, the accuracy test, anti-interference ability test, and line adaptability test of the sensor prototype were conducted. The accuracy test showed that the maximum relative error of voltage amplitude was 0.89%, and the phase relative error was 1.57%. The anti-interference ability test showed that the error offset was 0.25% when there were interference sources. The line adaptability test shows that the maximum relative error in testing different types of lines is 1.01%.
Open AccessSelf-Calibration Sensor for Contactless Voltage Measurement Based on Dynamic Capacitance
Noncontact voltage measurement has the advantages of simple handling, high construction safety, and not being affected by line insulation. However, in practical measurement of noncontact voltage, sensor gain is affected by wire diameter, wire insulation material, and relative position deviation. At the same time, it is also subject to interference from interphase or peripheral coupling electric fields. This paper proposes a noncontact voltage measurement self-calibration method based on dynamic capacitance, which realizes self-calibration of sensor gain through unknown line voltage to be measured. Firstly, the basic principle of the self-calibration method for noncontact voltage measurement based on dynamic capacitance is introduced. Subsequently, the sensor model and parameters were optimized through error analysis and simulation research. Based on this, a sensor prototype and remote dynamic capacitance control unit that can shield against interference are developed. Finally, the accuracy test, anti-interference ability test, and line adaptability test of the sensor prototype were conducted. The accuracy test showed that the maximum relative error of voltage amplitude was 0.89%, and the phase relative error was 1.57%. The anti-interference ability test showed that the error offset was 0.25% when there were interference sources. The line adaptability test shows that the maximum relative error in testing different types of lines is 1.01%.
- Open Access
Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a method for obtaining the magnetic field strength distribution in the tangential direction around the cable, finally enabling online self-calibration. The simulation and experimental results show that this method can self-calibrate the sensor arrays and reconstruct the phase current waveforms in three-phase four-wire power cables without calibration currents, and this method is not affected by disturbances such as wire diameter, current amplitudes, and high-frequency harmonics. This study reduces the time and equipment costs required to calibrate the sensing module compared to related studies using calibration currents. This research offers the possibility of fusing sensing modules directly with running primary equipment, and the development of hand-held measurement devices.
Open AccessOnline Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a method for obtaining the magnetic field strength distribution in the tangential direction around the cable, finally enabling online self-calibration. The simulation and experimental results show that this method can self-calibrate the sensor arrays and reconstruct the phase current waveforms in three-phase four-wire power cables without calibration currents, and this method is not affected by disturbances such as wire diameter, current amplitudes, and high-frequency harmonics. This study reduces the time and equipment costs required to calibrate the sensing module compared to related studies using calibration currents. This research offers the possibility of fusing sensing modules directly with running primary equipment, and the development of hand-held measurement devices.
- Open Access
Research on a Non-Contact Multi-Electrode Voltage Sensor and Signal Processing Algorithm
Traditional contact voltage measurement requires a direct electrical connection to the system, which is not easy to install and maintain. The voltage measurement based on the electric field coupling plate capacitance structure does not need to be in contact with the measured object or the ground, which can avoid the above problems. However, most of the existing flat-plate structure voltage measurement sensors are not only expensive to manufacture, but also bulky, and when the relative position between the wire under test and the sensor changes, it will bring great measurement errors, making it difficult to meet actual needs. Aiming to address the above problems, this paper proposes a multi-electrode array structure non-contact voltage sensor and signal processing algorithm. The sensor is manufactured by the PCB process, which effectively reduces the manufacturing cost and process difficulty. The experimental and simulation results show that, when the relative position of the wire and the sensor is offset by 10 mm in the 45° direction, the relative error of the traditional single-electrode voltage sensor is 17.62%, while the relative error of the multi-electrode voltage sensor designed in this paper is only 0.38%. In addition, the ratio error of the sensor under the condition of power frequency of 50 Hz is less than ±1% and the phase difference is less than 4°. The experimental results show that the sensor has good accuracy and linearity.
Open AccessResearch on a Non-Contact Multi-Electrode Voltage Sensor and Signal Processing Algorithm
Traditional contact voltage measurement requires a direct electrical connection to the system, which is not easy to install and maintain. The voltage measurement based on the electric field coupling plate capacitance structure does not need to be in contact with the measured object or the ground, which can avoid the above problems. However, most of the existing flat-plate structure voltage measurement sensors are not only expensive to manufacture, but also bulky, and when the relative position between the wire under test and the sensor changes, it will bring great measurement errors, making it difficult to meet actual needs. Aiming to address the above problems, this paper proposes a multi-electrode array structure non-contact voltage sensor and signal processing algorithm. The sensor is manufactured by the PCB process, which effectively reduces the manufacturing cost and process difficulty. The experimental and simulation results show that, when the relative position of the wire and the sensor is offset by 10 mm in the 45° direction, the relative error of the traditional single-electrode voltage sensor is 17.62%, while the relative error of the multi-electrode voltage sensor designed in this paper is only 0.38%. In addition, the ratio error of the sensor under the condition of power frequency of 50 Hz is less than ±1% and the phase difference is less than 4°. The experimental results show that the sensor has good accuracy and linearity.