Jason Floyd
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jason Floyd has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Dushyant M. Chaudhari
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
3 shared publications - Jonathan L. Hodges
JENSEN HUGHES
3 shared publications - Matthew J. DiDomizio
Fire Safety Research Institute, UL Research Institutes, Columbia, USA
2 shared publications - Anil Kapahi
RDT&E Division, Jensen Hughes, Baltimore, MD, USA
1 shared publication - Brian Y. Lattimer
Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA 24061, USA
1 shared publication Chandan Paul
1 shared publication
Latest Publications
- Open Access
- 14 March 2026
- Published by Elsevier in Fire Safety Journal
- Vol. 162
Modeling sodium bicarbonate powder extinguishment in a cup burner
- 14 March 2026
- Published by Elsevier in Fire Safety Journal
- Vol. 162
Open AccessModeling sodium bicarbonate powder extinguishment in a cup burner
- Open Access
- 12 June 2025
- Published by Springer Nature in Fire Technology
- Vol. 61 (7) , 4897-4935
An Approach for Flux and Thickness Scaling of Cone Calorimeter Data for Predicting the Pyrolysis of Materials
This paper presents an engineering approach to modeling pyrolysis. Instead of attempting to define detailed solid phase reactions, this method dynamically scales data from cone calorimeter tests of a material performed for different cone fluxes and/or sample thicknesses. The method can utilize data from multiple cone exposures and/or multiple sample thicknesses. The method compares the model predicted heat flux to a burning surface to the reference heat flux for a cone calorimeter test. The reference heat flux is the flame heat flux plus that portion of the cone heat flux that reaches the sample. In this method the reference heat flux is determined by table lookup of FDS simulations of a range of fuels and fuel burning rates in a cone geometry. The paper provides verification and validation of the approach. Validation is performed at multiple scales including a large series of 1D simulations for 141 materials, a cone calorimeter geometry for PMMA, a single burning item geometry for PMMA, a stack of wood pallets in a corner, and a room corner test at three length scales using plywood or fiber reinforced polymer. The method performs best for polymer and wood based materials. Specifically, it performed best when data from multiple cone exposures was self similar with a monotonic progression in peak burning rate as a function of exposure. The method showed a high degree of grid independence. The method also showed similar or improved performance to simulations using the detailed solid phase kinetics.
- 12 June 2025
- Published by Springer Nature in Fire Technology
- Vol. 61 (7) , 4897-4935
Open AccessAn Approach for Flux and Thickness Scaling of Cone Calorimeter Data for Predicting the Pyrolysis of Materials
This paper presents an engineering approach to modeling pyrolysis. Instead of attempting to define detailed solid phase reactions, this method dynamically scales data from cone calorimeter tests of a material performed for different cone fluxes and/or sample thicknesses. The method can utilize data from multiple cone exposures and/or multiple sample thicknesses. The method compares the model predicted heat flux to a burning surface to the reference heat flux for a cone calorimeter test. The reference heat flux is the flame heat flux plus that portion of the cone heat flux that reaches the sample. In this method the reference heat flux is determined by table lookup of FDS simulations of a range of fuels and fuel burning rates in a cone geometry. The paper provides verification and validation of the approach. Validation is performed at multiple scales including a large series of 1D simulations for 141 materials, a cone calorimeter geometry for PMMA, a single burning item geometry for PMMA, a stack of wood pallets in a corner, and a room corner test at three length scales using plywood or fiber reinforced polymer. The method performs best for polymer and wood based materials. Specifically, it performed best when data from multiple cone exposures was self similar with a monotonic progression in peak burning rate as a function of exposure. The method showed a high degree of grid independence. The method also showed similar or improved performance to simulations using the detailed solid phase kinetics.
- Open Access
- 2 June 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 250
Toward grid-independent modeling of natural convection with fire dynamics simulator
- 2 June 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 250
Open AccessToward grid-independent modeling of natural convection with fire dynamics simulator
- Open Access
- 29 April 2025
- Published by Springer Nature in Fire Technology
- p. 1-29
Modelling a Damper-Optimized Demand Control Ventilation System During a Fire
Modern heating, ventilation, and air conditioning (HVAC) systems have evolved from simple on-off, fan-driven systems to highly complex, energy-optimized systems involving sensors monitoring the building whose outputs result in dynamic changes to the HVAC system operation. In some buildings, the HVAC system is intended to aid in smoke and pressure control during the event of a fire. In such a case, the smoke, heat, and pressure from fire growth and spread interact with the HVAC system, while the control logic may react to the fire alarm and increase ventilation rates. A series of tests investigating the performance of modern damper-optimized demand control ventilation (DCV) systems during a fire and its effect on smoke and pressure control was recently performed. This paper examines the ability of Fire Dynamics Simulator (FDS) to model a DCV HVAC system undergoing a dynamic response change due to the presence of fire. Results show that the FDS HVAC model is capable of such simulations. However, there were challenges in the modelling process due to the limitations on the experimental data obtained from the real-world building management system software. A path forward for more complete simulations is identified.
- 29 April 2025
- Published by Springer Nature in Fire Technology
- p. 1-29
Open AccessModelling a Damper-Optimized Demand Control Ventilation System During a Fire
Modern heating, ventilation, and air conditioning (HVAC) systems have evolved from simple on-off, fan-driven systems to highly complex, energy-optimized systems involving sensors monitoring the building whose outputs result in dynamic changes to the HVAC system operation. In some buildings, the HVAC system is intended to aid in smoke and pressure control during the event of a fire. In such a case, the smoke, heat, and pressure from fire growth and spread interact with the HVAC system, while the control logic may react to the fire alarm and increase ventilation rates. A series of tests investigating the performance of modern damper-optimized demand control ventilation (DCV) systems during a fire and its effect on smoke and pressure control was recently performed. This paper examines the ability of Fire Dynamics Simulator (FDS) to model a DCV HVAC system undergoing a dynamic response change due to the presence of fire. Results show that the FDS HVAC model is capable of such simulations. However, there were challenges in the modelling process due to the limitations on the experimental data obtained from the real-world building management system software. A path forward for more complete simulations is identified.
- Open Access
- 26 February 2025
- Published by Elsevier in Fire Safety Journal
- Vol. 153
Separation of heat transfer modes in fire: Review and analysis
- 26 February 2025
- Published by Elsevier in Fire Safety Journal
- Vol. 153
Open AccessSeparation of heat transfer modes in fire: Review and analysis
- Open Access
- 25 April 2024
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 42 (3) , 248-278
Fire dynamics simulator modeling of a line-of-duty death in a firefighting training facility using recent research on materials and firefighter safety
In 2005, a line-of-duty death of an instructor at a firefighter training facility spawned research into both firefighter training and improving firefighter protective gear. Since the incident, there has been additional research into the material properties, firefighter facepiece performance, and the classification of firefighter exposures. This has been in parallel to significant improvements in the ability to model fires and predict, rather than prescribe, fire growth. As this recent body of work was not available at the time of incident investigation, the incident was revisited using the current version of Fire Dynamics Simulator. The full day of training evolutions was modeled in Fire Dynamics Simulator using recent data on wood pyrolysis (the fuel) and facepiece reaction to heat. Fire Dynamics Simulator results were evaluated against the testing done following the incident. Facepiece research was used to develop hole formation criteria that could be evaluated from Fire Dynamics Simulator predictions of facepiece exposure. This was used to compare the performance of facepieces contemporary with the incident to today’s facepieces. In addition, exposure predictions were evaluated in the context of exposure hazard categories developed for firefighter protective gear.
- 25 April 2024
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 42 (3) , 248-278
Open AccessFire dynamics simulator modeling of a line-of-duty death in a firefighting training facility using recent research on materials and firefighter safety
In 2005, a line-of-duty death of an instructor at a firefighter training facility spawned research into both firefighter training and improving firefighter protective gear. Since the incident, there has been additional research into the material properties, firefighter facepiece performance, and the classification of firefighter exposures. This has been in parallel to significant improvements in the ability to model fires and predict, rather than prescribe, fire growth. As this recent body of work was not available at the time of incident investigation, the incident was revisited using the current version of Fire Dynamics Simulator. The full day of training evolutions was modeled in Fire Dynamics Simulator using recent data on wood pyrolysis (the fuel) and facepiece reaction to heat. Fire Dynamics Simulator results were evaluated against the testing done following the incident. Facepiece research was used to develop hole formation criteria that could be evaluated from Fire Dynamics Simulator predictions of facepiece exposure. This was used to compare the performance of facepieces contemporary with the incident to today’s facepieces. In addition, exposure predictions were evaluated in the context of exposure hazard categories developed for firefighter protective gear.
- 23 September 2023
- Published by Elsevier in Fire Safety Journal
- Vol. 141, 103980
An engineering model for the pyrolysis of materials
- 23 September 2023
- Published by Elsevier in Fire Safety Journal
- Vol. 141, 103980
An engineering model for the pyrolysis of materials
- Open Access
- 17 March 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (4) , 1489-1517
Numerical Simulations of Gas Burner Experiments in a Residential Structure with HVAC System
Controlled fire experiments using a gas burner were previously conducted in a purpose-built, two-story, moderately air-tight residential structure to understand the effect of a heating, ventilating, and air conditioning (HVAC) system and door positions on the fire-induced environment. Temperatures, gas concentrations (oxygen, water vapor, carbon dioxide), and differential pressures were monitored throughout the structure. HVAC status (off vs. on) and stairwell door position of the fire room (open vs. closed) were varied for the experiments analyzed in this paper. In this study, Fire Dynamics Simulator (FDS) v. 6.7.9 was used to simulate these experiments. Experimental data quantifying the air tightness of the building and cold flowrates through HVAC vents were determined to be important to optimize leakages and HVAC loss coefficients for the simulation setup. Pressure development in the structure was predicted correctly to be higher on the first floor and lower in the basement, but the magnitude of steady-state pressure was underpredicted. The measured and predicted steady-state temperature distributions were statistically different for the cases with and without the HVAC on, regardless of the door position. FDS predicted gas transport through the HVAC duct network, and under-predicted temperature rise and water vapor content by about 9% and 10%, respectively, and over-predicted volumetric oxygen and carbon dioxide content by about 21% and 6%, respectively. Temperature rise prediction in the closed room, where the gas transport primarily occurred via the HVAC duct network, improved after including heat loss from the HVAC duct to the ambient.
- 17 March 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (4) , 1489-1517
Open AccessNumerical Simulations of Gas Burner Experiments in a Residential Structure with HVAC System
Controlled fire experiments using a gas burner were previously conducted in a purpose-built, two-story, moderately air-tight residential structure to understand the effect of a heating, ventilating, and air conditioning (HVAC) system and door positions on the fire-induced environment. Temperatures, gas concentrations (oxygen, water vapor, carbon dioxide), and differential pressures were monitored throughout the structure. HVAC status (off vs. on) and stairwell door position of the fire room (open vs. closed) were varied for the experiments analyzed in this paper. In this study, Fire Dynamics Simulator (FDS) v. 6.7.9 was used to simulate these experiments. Experimental data quantifying the air tightness of the building and cold flowrates through HVAC vents were determined to be important to optimize leakages and HVAC loss coefficients for the simulation setup. Pressure development in the structure was predicted correctly to be higher on the first floor and lower in the basement, but the magnitude of steady-state pressure was underpredicted. The measured and predicted steady-state temperature distributions were statistically different for the cases with and without the HVAC on, regardless of the door position. FDS predicted gas transport through the HVAC duct network, and under-predicted temperature rise and water vapor content by about 9% and 10%, respectively, and over-predicted volumetric oxygen and carbon dioxide content by about 21% and 6%, respectively. Temperature rise prediction in the closed room, where the gas transport primarily occurred via the HVAC duct network, improved after including heat loss from the HVAC duct to the ambient.
- 1 March 2023
- Published by ASTM International
- p. 161-169
Current and Future Parameters Used by the Fire Dynamics Simulator
This paper discusses important input parameters used by the Fire Dynamics Simulator, a computational fluid dynamics (CFD) model of fire. Suggestions are made for new or enhanced submodels and measurements specifically for CFD models of fire.
- 1 March 2023
- Published by ASTM International
- p. 161-169
Current and Future Parameters Used by the Fire Dynamics Simulator
This paper discusses important input parameters used by the Fire Dynamics Simulator, a computational fluid dynamics (CFD) model of fire. Suggestions are made for new or enhanced submodels and measurements specifically for CFD models of fire.
- 3 October 2022
- Published by Underwriters Laboratories Inc.
Analysis of a Near Miss in a Garden Apartment Fire – Georgia 2022
On February 9, 2022, Cobb County Fire and Emergency Services responded to a fire in a ground floor unit in a garden apartment building. At arrival, the fire was a post-flashover fire in a bedroom. Initial fire control was attempted by an interior fire attack team which was unable to quickly locate the fire. Exterior suppression through the bedroom window was started prior to discovery of the fire by the interior team. Shortly after fire discovery by the internal team, a mayday was called. Four firefighters from the interior fire attack team received first and second degree burns. This report analyzes photographic, video, and written documentation from the incident to evaluate the timeline of the incident and to assess the fire conditions present. Computer modeling using the Fire Dynamics Simulator (FDS) was performed to provide further insight into the fire conditions and the impact of decisions and actions on the fire ground. Additionally, data from a full scale fire test of a similar fire in a similar structure was used to provide additional insight. Four FDS simulations were performed in support of the analysis. These included a simulation of the event as it unfolded and three simulations looking at the impact of alternate tactics which included: initial exterior attack prior to entry, the use of a smoke curtain to protect the building exit path, and interior only attack. FDS simulations provided insight on the heat present in the apartment during the fire and the impact of the interior and exterior suppression on conditions inside the apartment. Full scale test data of a similar fire showed similar behavior to the FDS predictions and gives credence to the FDS results. Results of the analysis suggest that injuries resulted from the length of time the interior attack team was present inside the apartment before actions were taken to reduce the severity of the fire. Six contributing factors were identified including size-up, communication and accountability, delayed exterior attack, lack of entry hall protection, the apartment layout and construction, thermal imager use, and mayday procedures and training. The last contributing factor was a positive contribution that helped avoid more serious injuries. Based on the contributing factors, five recommendations were made that include improved size-up, exterior fire control to prevent exterior spread, protection of exit pathways, basing fire ground tactics on known information, and recognizing when a change in tactics is needed.
- 3 October 2022
- Published by Underwriters Laboratories Inc.
Analysis of a Near Miss in a Garden Apartment Fire – Georgia 2022
On February 9, 2022, Cobb County Fire and Emergency Services responded to a fire in a ground floor unit in a garden apartment building. At arrival, the fire was a post-flashover fire in a bedroom. Initial fire control was attempted by an interior fire attack team which was unable to quickly locate the fire. Exterior suppression through the bedroom window was started prior to discovery of the fire by the interior team. Shortly after fire discovery by the internal team, a mayday was called. Four firefighters from the interior fire attack team received first and second degree burns. This report analyzes photographic, video, and written documentation from the incident to evaluate the timeline of the incident and to assess the fire conditions present. Computer modeling using the Fire Dynamics Simulator (FDS) was performed to provide further insight into the fire conditions and the impact of decisions and actions on the fire ground. Additionally, data from a full scale fire test of a similar fire in a similar structure was used to provide additional insight. Four FDS simulations were performed in support of the analysis. These included a simulation of the event as it unfolded and three simulations looking at the impact of alternate tactics which included: initial exterior attack prior to entry, the use of a smoke curtain to protect the building exit path, and interior only attack. FDS simulations provided insight on the heat present in the apartment during the fire and the impact of the interior and exterior suppression on conditions inside the apartment. Full scale test data of a similar fire showed similar behavior to the FDS predictions and gives credence to the FDS results. Results of the analysis suggest that injuries resulted from the length of time the interior attack team was present inside the apartment before actions were taken to reduce the severity of the fire. Six contributing factors were identified including size-up, communication and accountability, delayed exterior attack, lack of entry hall protection, the apartment layout and construction, thermal imager use, and mayday procedures and training. The last contributing factor was a positive contribution that helped avoid more serious injuries. Based on the contributing factors, five recommendations were made that include improved size-up, exterior fire control to prevent exterior spread, protection of exit pathways, basing fire ground tactics on known information, and recognizing when a change in tactics is needed.