Laurent Sandrin
Research Subjects
Laurent Sandrin has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Véronique Miette
Echosens, Paris, France
3 shared publications - Mathias Fink
Institut Langevin, ESPCI Paris, PSL University, CNRS, Paris, France
2 shared publications - Mickael Tanter
Physics for Medicine, ESPCI, INSERM, CNRS, PSL University
2 shared publications André Constantinesco
Service de Biophysique et Médecine Nucléaire, CHU Hautepierre, UMR 7507, Strasbourg, France
1 shared publicationArun J. Sanyal
Director, Stravitz-Sanyal Institute of Liver Disease and Metabolic Health, VCU School of Medicine and Chair, Division of Gastroenterology, Hepatology and Nutrition in the Department of Internal medicine at VCU School of Medicine, Richmond, VA, USA
1 shared publicationAymeric Labourdette
Echosens, Paris, France
1 shared publication
Latest Publications
- Open Access
- 5 January 2024
- Published by Georg Thieme Verlag KG in Ultrasound International Open
- Vol. 10 (CP) , a23786926
Ultrasound elastography: a brief clinical history of an evolving technique
The history of the emerging elastographic technique is presented. Ultrasound imaging of elasticity and tissue strain has gained clinical acceptance as an established technique useful in routine daily clinical practice.
- 5 January 2024
- Published by Georg Thieme Verlag KG in Ultrasound International Open
- Vol. 10 (CP) , a23786926
Open AccessUltrasound elastography: a brief clinical history of an evolving technique
The history of the emerging elastographic technique is presented. Ultrasound imaging of elasticity and tissue strain has gained clinical acceptance as an established technique useful in routine daily clinical practice.
- Open Access
- 28 November 2023
- Published by Wiley in Liver International
- Vol. 44 (2) , 344-356
Liver stiffness as a cornerstone in heart disease risk assessment
Metabolic dysfunction‐associated steatotic liver disease (MASLD) typically presents with hepatic fibrosis in advanced disease, resulting in increased liver stiffness. A subset of patients further develops liver cirrhosis and hepatocellular carcinoma. Cardiovascular disease is a common comorbidity in patients with MASLD and its prevalence is increasing in parallel. Recent evidence suggests that especially liver stiffness, whether or not existing against a background of MASLD, is associated with heart diseases. We conducted a narrative review on the role of liver stiffness in the prediction of highly prevalent heart diseases including heart failure, cardiac arrhythmias (in particular atrial fibrillation), coronary heart disease, and aortic valve sclerosis. Research papers were retrieved from major scientific databases (PubMed, Web of Science) until September 2023 using ‘liver stiffness’ and ‘liver fibrosis’ as keywords along with the latter cardiac conditions. Increased liver stiffness, determined by vibration‐controlled transient elastography or hepatic fibrosis as predicted by biomarker panels, are associated with a variety of cardiovascular diseases, including heart failure, atrial fibrillation, and coronary heart disease. Elevated liver stiffness in patients with metabolic liver disease should lead to considerations of cardiac workup including N‐terminal pro–B‐type natriuretic peptide/B‐type natriuretic peptide determination, electrocardiography, and coronary computed tomography angiography. In addition, patients with MASLD would benefit from heart disease case‐finding strategies in which liver stiffness measurements can play a key role. In conclusion, increased liver stiffness should be a trigger to consider a cardiac workup in metabolically compromised patients.
- 28 November 2023
- Published by Wiley in Liver International
- Vol. 44 (2) , 344-356
Open AccessLiver stiffness as a cornerstone in heart disease risk assessment
Metabolic dysfunction‐associated steatotic liver disease (MASLD) typically presents with hepatic fibrosis in advanced disease, resulting in increased liver stiffness. A subset of patients further develops liver cirrhosis and hepatocellular carcinoma. Cardiovascular disease is a common comorbidity in patients with MASLD and its prevalence is increasing in parallel. Recent evidence suggests that especially liver stiffness, whether or not existing against a background of MASLD, is associated with heart diseases. We conducted a narrative review on the role of liver stiffness in the prediction of highly prevalent heart diseases including heart failure, cardiac arrhythmias (in particular atrial fibrillation), coronary heart disease, and aortic valve sclerosis. Research papers were retrieved from major scientific databases (PubMed, Web of Science) until September 2023 using ‘liver stiffness’ and ‘liver fibrosis’ as keywords along with the latter cardiac conditions. Increased liver stiffness, determined by vibration‐controlled transient elastography or hepatic fibrosis as predicted by biomarker panels, are associated with a variety of cardiovascular diseases, including heart failure, atrial fibrillation, and coronary heart disease. Elevated liver stiffness in patients with metabolic liver disease should lead to considerations of cardiac workup including N‐terminal pro–B‐type natriuretic peptide/B‐type natriuretic peptide determination, electrocardiography, and coronary computed tomography angiography. In addition, patients with MASLD would benefit from heart disease case‐finding strategies in which liver stiffness measurements can play a key role. In conclusion, increased liver stiffness should be a trigger to consider a cardiac workup in metabolically compromised patients.
- Top Cited PapersOpen Access
- 11 November 2022
- Published by Elsevier in Journal of Hepatology
- Vol. 78 (2) , 247-259
Enhanced diagnosis of advanced fibrosis and cirrhosis in individuals with NAFLD using FibroScan-based Agile scores
- 11 November 2022
- Published by Elsevier in Journal of Hepatology
- Vol. 78 (2) , 247-259
Top Cited PapersOpen AccessEnhanced diagnosis of advanced fibrosis and cirrhosis in individuals with NAFLD using FibroScan-based Agile scores
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Hybrid Elastography: A New Technique for the Assessment of Tissue Stiffness
Vibration-Controlled Transient Elastography (VCTE) is a clinically well validated method to assess Liver Stiffness (LS) using FibroScan (Echosens, Paris, France). The operator relies on ultrasound (U/S) A-and M-mode images to locate the liver. Finding a good measurement window is key to get a good penetration of the Shear Wave (SW) and therefore a valid LS measurement. However, relying only on U/S may be suboptimal to identify the right measurement position. We developed a new technique called Hybrid Elastography (HE) that combines monochromatic and transient elastography, respectively to assist the operator finding an optimal measurement position and to perform the measurement.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Hybrid Elastography: A New Technique for the Assessment of Tissue Stiffness
Vibration-Controlled Transient Elastography (VCTE) is a clinically well validated method to assess Liver Stiffness (LS) using FibroScan (Echosens, Paris, France). The operator relies on ultrasound (U/S) A-and M-mode images to locate the liver. Finding a good measurement window is key to get a good penetration of the Shear Wave (SW) and therefore a valid LS measurement. However, relying only on U/S may be suboptimal to identify the right measurement position. We developed a new technique called Hybrid Elastography (HE) that combines monochromatic and transient elastography, respectively to assist the operator finding an optimal measurement position and to perform the measurement.
- 4 November 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (22) , 6979-6990
Ultrasound-based transient elastography compared to magnetic resonance elastography in soft tissue-mimicking gels
Ultrasound-based transient elastography (TE) and magnetic resonance elastography (MRE) are increasingly used methods for the clinical evaluation of soft tissue mechanical properties and their alteration under diseased conditions. This study proposes a comparison between magnetic resonance elastography (MRE) and ultrasound-based transient elastography (TE). Both methods were tested on the same soft tissue-mimicking gels in a common frequency range in order to allow for direct quantitative comparison. For the four gels tested, relatively good agreement was found between the shear moduli measured by both methods, with an averaged relative difference of 23%. This study demonstrates that under the assumption of homogeneous media that are significantly more elastic than viscous, quantitative results obtained by both methods are comparable.
- 4 November 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (22) , 6979-6990
Ultrasound-based transient elastography compared to magnetic resonance elastography in soft tissue-mimicking gels
Ultrasound-based transient elastography (TE) and magnetic resonance elastography (MRE) are increasingly used methods for the clinical evaluation of soft tissue mechanical properties and their alteration under diseased conditions. This study proposes a comparison between magnetic resonance elastography (MRE) and ultrasound-based transient elastography (TE). Both methods were tested on the same soft tissue-mimicking gels in a common frequency range in order to allow for direct quantitative comparison. For the four gels tested, relatively good agreement was found between the shear moduli measured by both methods, with an averaged relative difference of 23%. This study demonstrates that under the assumption of homogeneous media that are significantly more elastic than viscous, quantitative results obtained by both methods are comparable.
- 29 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (3) , 654-664
Real-time Chirp-Coded Imaging With a Programmable Ultrasound Biomicroscope
Ultrasound biomicroscopy (UBM) of mice can provide a testing ground for new imaging strategies. The UBM system presented in this paper facilitates the development of imaging and measurement methods with programmable design, arbitrary waveform coding, broad bandwidth (2-80 MHz), digital filtering, programmable processing, RF data acquisition, multithread/multicore real-time display, and rapid mechanical scanning (¿170 frames/s). To demonstrate the capacities of the UBM system, chirp (1.28, 2.56, and 5.12 ¿s durations) sequences with matched filter analysis are implemented in real time. Chirp and conventional impulse imaging (31 and 46 MHz center frequencies) of a wire phantom at fast sectorial scanning (0.7° ms-1, 20 frames/s one-way image rate) are compared. Axial and lateral resolutions at the focus with chirps approach impulse imaging resolutions. Chirps yield 10-15 dB gain in SNR and a 2-3 mm gain in imaging depth. Real-time impulse and chirp-coded imaging (at 10-5 frames/s) are demonstrated in the mouse, in vivo. The system's open structure favors test and implementation of new sequences.
- 29 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (3) , 654-664
Real-time Chirp-Coded Imaging With a Programmable Ultrasound Biomicroscope
Ultrasound biomicroscopy (UBM) of mice can provide a testing ground for new imaging strategies. The UBM system presented in this paper facilitates the development of imaging and measurement methods with programmable design, arbitrary waveform coding, broad bandwidth (2-80 MHz), digital filtering, programmable processing, RF data acquisition, multithread/multicore real-time display, and rapid mechanical scanning (¿170 frames/s). To demonstrate the capacities of the UBM system, chirp (1.28, 2.56, and 5.12 ¿s durations) sequences with matched filter analysis are implemented in real time. Chirp and conventional impulse imaging (31 and 46 MHz center frequencies) of a wire phantom at fast sectorial scanning (0.7° ms-1, 20 frames/s one-way image rate) are compared. Axial and lateral resolutions at the focus with chirps approach impulse imaging resolutions. Chirps yield 10-15 dB gain in SNR and a 2-3 mm gain in imaging depth. Real-time impulse and chirp-coded imaging (at 10-5 frames/s) are demonstrated in the mouse, in vivo. The system's open structure favors test and implementation of new sequences.
- Open Access
- 22 December 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (10510117) , 1811-1820 vol.2
Ultra high speed imaging of elasticity
Ultrafast ultrasonic imaging seems to have a strong potential for medical imaging applications. During the past five years, it has been applied successfully to quantitative assessment of soft tissues elasticity. An ultrafast ultrasonic scanner was built in our lab for quantitatively mapping the shear elasticity of soft tissues. The ultrafast Scanner provides images of the echogenecity of tissues similar to a standard echographic device but with a 200 times higher a frame rate. It allows to detect fast tissue motion induced by low frequency shear waves inside the body. From these displacements, a shear elasticity map is constructed using inverse problem algorithms. Preliminary in vivo results in breast demonstrate that this technique, known as transient elastography, is very sensitive to the presence of hard tumors. The same technique can also be combined with remote palpation induced par ultrasonic radiation pressure to replace the usual external vibrating system The same probe allows both to generate and detect shear waves propagation by using an unusual emission-reception sequence.
- 22 December 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (10510117) , 1811-1820 vol.2
Open AccessUltra high speed imaging of elasticity
Ultrafast ultrasonic imaging seems to have a strong potential for medical imaging applications. During the past five years, it has been applied successfully to quantitative assessment of soft tissues elasticity. An ultrafast ultrasonic scanner was built in our lab for quantitatively mapping the shear elasticity of soft tissues. The ultrafast Scanner provides images of the echogenecity of tissues similar to a standard echographic device but with a 200 times higher a frame rate. It allows to detect fast tissue motion induced by low frequency shear waves inside the body. From these displacements, a shear elasticity map is constructed using inverse problem algorithms. Preliminary in vivo results in breast demonstrate that this technique, known as transient elastography, is very sensitive to the presence of hard tumors. The same technique can also be combined with remote palpation induced par ultrasonic radiation pressure to replace the usual external vibrating system The same probe allows both to generate and detect shear waves propagation by using an unusual emission-reception sequence.