Yuqiao Xiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuqiao Xiang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jiaqiu Wang
School of Computer Science and Digital Technologies, London South Bank University, London SE1 0AA, UK
4 shared publications - Zhiyong Li
School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia
4 shared publications Han Yu
Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
2 shared publicationsHao Wu
School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu, China
2 shared publications- Haveena Anbananthan
School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia
2 shared publications Jessica Benitez Mendieta
Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
2 shared publications
Latest Publications
- Open Access
- 9 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 66466-66477
Impact of Speckle Deformability on Digital Imaging Correlation
Digital Image Correlation (DIC) has been widely used as a non-contact deformation measurement technique. Nevertheless, its accuracy is greatly affected by the speckle pattern on the specimen. To systematically evaluate how speckle deformability affects the precision of DIC algorithms. In this study, a test dataset of 2D speckle patterns with various prescribed deformation fields was numerically generated, containing two categories of speckles, i.e., the deformable and the non-deformable (rigid) ones. This dataset was used to evaluate the performance of inverse compositional Gauss-Newton (ICGN)-based DIC algorithms with two types of shape function (first-order and second-order), in the different scenarios of the deformation field. The results showed that imaging noise had a significant influence on the DIC algorithm. The first-order shape function (ICGN-1) performed better when tracking the simple linear deformation field. While the second-order shape function (ICGN-2) was proved to perform better on non-linear deformations. Moreover, the deformability of the speckle was found to have an obvious impact on the performance of the DIC algorithm. ICGN-2 could effectively reduce so-called speckle rigidity induced (SRI) error. Conclusively, ICGN-2 should be chosen as priority, because of its feasibility on non-linear deformation fields and speckle rigidity. While in the linear deformation scenarios, ICGN-1 was still a robust and efficient method.
- 9 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 66466-66477
Open AccessImpact of Speckle Deformability on Digital Imaging Correlation
Digital Image Correlation (DIC) has been widely used as a non-contact deformation measurement technique. Nevertheless, its accuracy is greatly affected by the speckle pattern on the specimen. To systematically evaluate how speckle deformability affects the precision of DIC algorithms. In this study, a test dataset of 2D speckle patterns with various prescribed deformation fields was numerically generated, containing two categories of speckles, i.e., the deformable and the non-deformable (rigid) ones. This dataset was used to evaluate the performance of inverse compositional Gauss-Newton (ICGN)-based DIC algorithms with two types of shape function (first-order and second-order), in the different scenarios of the deformation field. The results showed that imaging noise had a significant influence on the DIC algorithm. The first-order shape function (ICGN-1) performed better when tracking the simple linear deformation field. While the second-order shape function (ICGN-2) was proved to perform better on non-linear deformations. Moreover, the deformability of the speckle was found to have an obvious impact on the performance of the DIC algorithm. ICGN-2 could effectively reduce so-called speckle rigidity induced (SRI) error. Conclusively, ICGN-2 should be chosen as priority, because of its feasibility on non-linear deformation fields and speckle rigidity. While in the linear deformation scenarios, ICGN-1 was still a robust and efficient method.
- Open Access
- 10 December 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 244, 107975
Constrained estimation of intracranial aneurysm surface deformation using 4D-CTA
- 10 December 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 244, 107975
Open AccessConstrained estimation of intracranial aneurysm surface deformation using 4D-CTA
- 5 January 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 22 (2) , 729-738
Impact of cyclic bending on coronary hemodynamics
It remains unknown that the degree of bias in computational fluid dynamics results without considering coronary cyclic bending. This study aims to investigate the influence of different rates of coronary cyclic bending on coronary hemodynamics. To model coronary bending, a multi-ring-controlled fluid–structural interaction model was designed. A coronary artery was simulated with various cyclic bending rates (0.5, 0.75 and 1 s, corresponding to heart rates of 120, 80 and 60 bpm) and compared against a stable model. The simulated results show that the hemodynamic parameters of vortex Q-criterion, temporal wall shear stress (WSS), time-averaged WSS (TaWSS) and oscillatory shear index (OSI) were sensitive to the changes in cyclic rate. A higher heart rate resulted in higher magnitude and larger variance in the hemodynamic parameters. Whereas, the values and distributions of flow velocity and relative residence time (RRT) did not show significant differences between different bending periods. This study suggests that a stable coronary model is not sufficient to represent the hemodynamics in a bending coronary artery. Different heart rate conditions were found to have significant impact on the hemodynamic parameters. Thus, cyclic bending should be considered to mimic the realistic hemodynamics in future patient-specific coronary hemodynamics studies.
- 5 January 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 22 (2) , 729-738
Impact of cyclic bending on coronary hemodynamics
It remains unknown that the degree of bias in computational fluid dynamics results without considering coronary cyclic bending. This study aims to investigate the influence of different rates of coronary cyclic bending on coronary hemodynamics. To model coronary bending, a multi-ring-controlled fluid–structural interaction model was designed. A coronary artery was simulated with various cyclic bending rates (0.5, 0.75 and 1 s, corresponding to heart rates of 120, 80 and 60 bpm) and compared against a stable model. The simulated results show that the hemodynamic parameters of vortex Q-criterion, temporal wall shear stress (WSS), time-averaged WSS (TaWSS) and oscillatory shear index (OSI) were sensitive to the changes in cyclic rate. A higher heart rate resulted in higher magnitude and larger variance in the hemodynamic parameters. Whereas, the values and distributions of flow velocity and relative residence time (RRT) did not show significant differences between different bending periods. This study suggests that a stable coronary model is not sufficient to represent the hemodynamics in a bending coronary artery. Different heart rate conditions were found to have significant impact on the hemodynamic parameters. Thus, cyclic bending should be considered to mimic the realistic hemodynamics in future patient-specific coronary hemodynamics studies.
- Open Access
- 24 November 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (12) , 3038
The Need to Shift from Morphological to Structural Assessment for Carotid Plaque Vulnerability
Degree of luminal stenosis is generally considered to be an important indicator for judging the risk of atherosclerosis burden. However, patients with the same or similar degree of stenosis may have significant differences in plaque morphology and biomechanical factors. This study investigated three patients with carotid atherosclerosis within a similar range of stenosis. Using our developed fluid–structure interaction (FSI) modelling method, this study analyzed and compared the morphological and biomechanical parameters of the three patients. Although their degrees of carotid stenosis were similar, the plaque components showed a significant difference. The distribution range of time-averaged wall shear stress (TAWSS) of patient 2 was wider than that of patient 1 and patient 3. Patient 2 also had a much smaller plaque stress compared to the other two patients. There were significant differences in TAWSS and plaque stresses among three patients. This study suggests that plaque vulnerability is not determined by a single morphological factor, but rather by the combined structure. It is necessary to transform the morphological assessment into a structural assessment of the risk of plaque rupture.
- 24 November 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (12) , 3038
Open AccessThe Need to Shift from Morphological to Structural Assessment for Carotid Plaque Vulnerability
Degree of luminal stenosis is generally considered to be an important indicator for judging the risk of atherosclerosis burden. However, patients with the same or similar degree of stenosis may have significant differences in plaque morphology and biomechanical factors. This study investigated three patients with carotid atherosclerosis within a similar range of stenosis. Using our developed fluid–structure interaction (FSI) modelling method, this study analyzed and compared the morphological and biomechanical parameters of the three patients. Although their degrees of carotid stenosis were similar, the plaque components showed a significant difference. The distribution range of time-averaged wall shear stress (TAWSS) of patient 2 was wider than that of patient 1 and patient 3. Patient 2 also had a much smaller plaque stress compared to the other two patients. There were significant differences in TAWSS and plaque stresses among three patients. This study suggests that plaque vulnerability is not determined by a single morphological factor, but rather by the combined structure. It is necessary to transform the morphological assessment into a structural assessment of the risk of plaque rupture.