Haveena Anbananthan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haveena Anbananthan has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Zhiyong Li
School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia
4 shared publications - Jessica Benitez Mendieta
School of Mechanical, Medical and Process Engineering, Queensland University of Technology (QUT), Brisbane, Australia
3 shared publications - Tiago Guerzet Sardenberg Lima
School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia
3 shared publications - Han Yu
School of Mechanical, Medical and Process Engineering, Queensland University of Technology 1 , Brisbane, QLD 4000
2 shared publications - Jiaqiu Wang
School of Computer Science and Digital Technologies, London South Bank University, London SE1 0AA, UK
2 shared publications - Yuqiao Xiang
School Of Mechanical, Medical And Process Engineering, Queensland University Of Technology, Brisbane, QLD 4000, Australia
2 shared publications
Latest Publications
- Open Access
Identifying cytokine-release signatures of flow-driven endothelial remodelling in an intracranial aneurysm cell culture model
Intracranial aneurysm (IA) rupture is catastrophic, yet current models of rupture-risk inadequately capture underlying IA remodelling mechanisms. Endothelial-haemodynamic interactions are central to these processes, but in vitro flow platforms often lack vessel-relevant geometry or long-term perfusion. Here, temporal and spatial endothelial responses to haemodynamic stress were investigated across idealised and patient-specific vascular models. Polydimethylsiloxane models were endothelialised with human aortic endothelial cells then perfused at up to 1.6 Pa wall shear stress for five days. IA models were exposed to steady or cardiovascular flow waveforms, with endothelial phenotype assessed by immunofluorescence and cytokine profiling. Flow initiation induced a transient inflammatory response, with elevated MCP-1 and TNF-α at day two, followed by a resolution of cytokine levels by day five, including a ∼7.5-fold reduction in MCP-1, despite increased haemodynamic loading. Endothelial cells retained a cobblestone-like morphology with eNOS undetected, resembling a partially activated phenotype. Compared with steady flow, cardiovascular flow reduced TGF-β1 and IL-8 secretion and decreased FGF-b consumption (∼2.5 fold), suggesting enhanced phenotypic stability. This study presents the first in vitro IA model incorporating a cardiovascular flow waveform and identifies cytokine signatures with potential utility as biomarkers of IA remodelling, highlighting the importance of long-term perfusion for modelling chronic vascular disease. Table of Contents Figure: An in vitro model of an intracranial aneurysm was developed to investigate how fluid flow dynamics impact endothelial remodelling and inflammation. Pulsatile cardiac flow promoted stabilisation of inflammatory signalling, which was sustained under a steady flow regime. Cytokine signatures emerged with potential utility as biomarkers of IA remodelling, highlighting the importance of long-term perfusion for modelling chronic vascular disease. The schematic of the cytokine release dynamics used in the graphical abstract below was generated with the assistance of AI-based tools including ChatGPT (v5.5) and M365 Copilot to align with key results from this manuscript.
Open AccessIdentifying cytokine-release signatures of flow-driven endothelial remodelling in an intracranial aneurysm cell culture model
Intracranial aneurysm (IA) rupture is catastrophic, yet current models of rupture-risk inadequately capture underlying IA remodelling mechanisms. Endothelial-haemodynamic interactions are central to these processes, but in vitro flow platforms often lack vessel-relevant geometry or long-term perfusion. Here, temporal and spatial endothelial responses to haemodynamic stress were investigated across idealised and patient-specific vascular models. Polydimethylsiloxane models were endothelialised with human aortic endothelial cells then perfused at up to 1.6 Pa wall shear stress for five days. IA models were exposed to steady or cardiovascular flow waveforms, with endothelial phenotype assessed by immunofluorescence and cytokine profiling. Flow initiation induced a transient inflammatory response, with elevated MCP-1 and TNF-α at day two, followed by a resolution of cytokine levels by day five, including a ∼7.5-fold reduction in MCP-1, despite increased haemodynamic loading. Endothelial cells retained a cobblestone-like morphology with eNOS undetected, resembling a partially activated phenotype. Compared with steady flow, cardiovascular flow reduced TGF-β1 and IL-8 secretion and decreased FGF-b consumption (∼2.5 fold), suggesting enhanced phenotypic stability. This study presents the first in vitro IA model incorporating a cardiovascular flow waveform and identifies cytokine signatures with potential utility as biomarkers of IA remodelling, highlighting the importance of long-term perfusion for modelling chronic vascular disease. Table of Contents Figure: An in vitro model of an intracranial aneurysm was developed to investigate how fluid flow dynamics impact endothelial remodelling and inflammation. Pulsatile cardiac flow promoted stabilisation of inflammatory signalling, which was sustained under a steady flow regime. Cytokine signatures emerged with potential utility as biomarkers of IA remodelling, highlighting the importance of long-term perfusion for modelling chronic vascular disease. The schematic of the cytokine release dynamics used in the graphical abstract below was generated with the assistance of AI-based tools including ChatGPT (v5.5) and M365 Copilot to align with key results from this manuscript.
- Open Access
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Fidelity of wall tap pressure measurements in steady and pulsatile flow
Accurate wall pressure measurements quantify pressure gradients in internal flows, yet a flush wall tap is not passive: tap geometry can bias static pressure, and the tap, pressure tubing, and sensor pathway can attenuate pulsatile fluctuations. We quantify wall pressure measurement fidelity over Reynolds numbers up to 704 by separating steady tap effects, dynamic transmission, and sensitivity to as-built geometry in experiments and computational fluid dynamics (CFD). Steady tests evaluated tap diameter bias (0.4, 0.8, and 1.0 mm) and compared CFD on computer-aided design and micro-computed tomography reconstructed lumens. A symmetric phantom with mirrored taps was tested at 1 Hz to quantify attenuation for 0.5 and 1.0 mm taps and two tubing lengths (560 and 2240 mm). The workflow was applied to a patient-specific intracranial aneurysm (IA) phantom with ten taps, fabricated by three-dimensional printing. Steady cases and a sinusoidal case were compared with matched rigid-wall CFD driven by the measured inflow waveform. Tap diameter weakly affected steady differential pressure, but 0.5 mm taps attenuated pulsatile amplitude, while tubing length changed amplitude by <1% at 1 Hz. In the IA phantom, the main discrepancies were in pressure magnitude rather than spatial pattern: CFD captured normalized spatial pressure distributions but underpredicted gauge pressure by 22%–28% in steady flow, pulsatile amplitude by 42%, and peak differential pressure by 15%. These results show that agreement in waveform shape or spatial trends can coexist with large magnitude error unless pressure transmission, as-built geometry, and inlet definition are verified and uncertainties are considered.
- 1 May 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (5)
Open AccessFidelity of wall tap pressure measurements in steady and pulsatile flow
Accurate wall pressure measurements quantify pressure gradients in internal flows, yet a flush wall tap is not passive: tap geometry can bias static pressure, and the tap, pressure tubing, and sensor pathway can attenuate pulsatile fluctuations. We quantify wall pressure measurement fidelity over Reynolds numbers up to 704 by separating steady tap effects, dynamic transmission, and sensitivity to as-built geometry in experiments and computational fluid dynamics (CFD). Steady tests evaluated tap diameter bias (0.4, 0.8, and 1.0 mm) and compared CFD on computer-aided design and micro-computed tomography reconstructed lumens. A symmetric phantom with mirrored taps was tested at 1 Hz to quantify attenuation for 0.5 and 1.0 mm taps and two tubing lengths (560 and 2240 mm). The workflow was applied to a patient-specific intracranial aneurysm (IA) phantom with ten taps, fabricated by three-dimensional printing. Steady cases and a sinusoidal case were compared with matched rigid-wall CFD driven by the measured inflow waveform. Tap diameter weakly affected steady differential pressure, but 0.5 mm taps attenuated pulsatile amplitude, while tubing length changed amplitude by <1% at 1 Hz. In the IA phantom, the main discrepancies were in pressure magnitude rather than spatial pattern: CFD captured normalized spatial pressure distributions but underpredicted gauge pressure by 22%–28% in steady flow, pulsatile amplitude by 42%, and peak differential pressure by 15%. These results show that agreement in waveform shape or spatial trends can coexist with large magnitude error unless pressure transmission, as-built geometry, and inlet definition are verified and uncertainties are considered.
- Open Access
- 6 September 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1) , 1-11
Haemodynamic characteristics of thin-walled regions in intracranial aneurysms: intraoperative imaging and CFD analysis
Background: Identifying haemodynamic factors associated with thin-walled regions (TWRs) of intracranial aneurysms is critical for improving pre-surgical rupture risk assessment. Intraoperatively, these regions are visually distinguished by a red, translucent appearance and are considered highly rupture prone. However, current imaging modalities lack the resolution to detect such vulnerable areas preoperatively. This study aimed to determine whether thin-walled regions exhibit distinct local haemodynamic profiles compared to adjacent normal-appearing wall regions. Methods: Sixteen patient-specific models of unruptured middle cerebral artery aneurysms were reconstructed from digital subtraction angiography images. Intraoperative TWRs were identified using a colour segmentation method based on Delta E metrics. Computational fluid dynamics (CFD) simulations were used to compute six haemodynamic parameters: wall shear stress (WSS), time-averaged WSS (TaWSS), oscillatory shear index (OSI), relative residence time (RRT), WSS divergence (WSSD), and pressure. Haemodynamic data were extracted from spatially localised surface patches within confirmed thin and normal regions. Linear mixed-effects models were applied to compare parameters while accounting for patient-level and intra-patient variability, using normalised values to improve model fit. Results: Thin regions exhibited significantly higher WSS, TaWSS, WSSD, and pressure, and reduced RRT. WSS and TaWSS were approximately 3.3% and 2.8% higher in TWRs, respectively. WSSD was 5.4% higher and RRT was 0.3% lower, suggesting faster, more divergent flow in thin regions. Pressure was modestly but significantly elevated at + 1.3%. No significant difference was observed in OSI between regions. Conclusions: Thin-walled regions in intracranial aneurysms demonstrate a distinctive haemodynamic profile characterised by stronger, sustained shear forces, greater shear divergence, and reduced residence time, suggesting a dynamic mechanical environment that promotes focal wall thinning. Our findings suggest that persistent shear-driven stress, rather than oscillatory flow, is a key haemodynamic feature of thin-walled regions and may contribute to localised aneurysm wall vulnerability.
- 6 September 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1) , 1-11
Open AccessHaemodynamic characteristics of thin-walled regions in intracranial aneurysms: intraoperative imaging and CFD analysis
Background: Identifying haemodynamic factors associated with thin-walled regions (TWRs) of intracranial aneurysms is critical for improving pre-surgical rupture risk assessment. Intraoperatively, these regions are visually distinguished by a red, translucent appearance and are considered highly rupture prone. However, current imaging modalities lack the resolution to detect such vulnerable areas preoperatively. This study aimed to determine whether thin-walled regions exhibit distinct local haemodynamic profiles compared to adjacent normal-appearing wall regions. Methods: Sixteen patient-specific models of unruptured middle cerebral artery aneurysms were reconstructed from digital subtraction angiography images. Intraoperative TWRs were identified using a colour segmentation method based on Delta E metrics. Computational fluid dynamics (CFD) simulations were used to compute six haemodynamic parameters: wall shear stress (WSS), time-averaged WSS (TaWSS), oscillatory shear index (OSI), relative residence time (RRT), WSS divergence (WSSD), and pressure. Haemodynamic data were extracted from spatially localised surface patches within confirmed thin and normal regions. Linear mixed-effects models were applied to compare parameters while accounting for patient-level and intra-patient variability, using normalised values to improve model fit. Results: Thin regions exhibited significantly higher WSS, TaWSS, WSSD, and pressure, and reduced RRT. WSS and TaWSS were approximately 3.3% and 2.8% higher in TWRs, respectively. WSSD was 5.4% higher and RRT was 0.3% lower, suggesting faster, more divergent flow in thin regions. Pressure was modestly but significantly elevated at + 1.3%. No significant difference was observed in OSI between regions. Conclusions: Thin-walled regions in intracranial aneurysms demonstrate a distinctive haemodynamic profile characterised by stronger, sustained shear forces, greater shear divergence, and reduced residence time, suggesting a dynamic mechanical environment that promotes focal wall thinning. Our findings suggest that persistent shear-driven stress, rather than oscillatory flow, is a key haemodynamic feature of thin-walled regions and may contribute to localised aneurysm wall vulnerability.
- Open Access
- 10 December 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 244, 107975
Constrained estimation of intracranial aneurysm surface deformation using 4D-CTA
- 10 December 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 244, 107975
Open AccessConstrained estimation of intracranial aneurysm surface deformation using 4D-CTA
- 5 January 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 22 (2) , 729-738
Impact of cyclic bending on coronary hemodynamics
It remains unknown that the degree of bias in computational fluid dynamics results without considering coronary cyclic bending. This study aims to investigate the influence of different rates of coronary cyclic bending on coronary hemodynamics. To model coronary bending, a multi-ring-controlled fluid–structural interaction model was designed. A coronary artery was simulated with various cyclic bending rates (0.5, 0.75 and 1 s, corresponding to heart rates of 120, 80 and 60 bpm) and compared against a stable model. The simulated results show that the hemodynamic parameters of vortex Q-criterion, temporal wall shear stress (WSS), time-averaged WSS (TaWSS) and oscillatory shear index (OSI) were sensitive to the changes in cyclic rate. A higher heart rate resulted in higher magnitude and larger variance in the hemodynamic parameters. Whereas, the values and distributions of flow velocity and relative residence time (RRT) did not show significant differences between different bending periods. This study suggests that a stable coronary model is not sufficient to represent the hemodynamics in a bending coronary artery. Different heart rate conditions were found to have significant impact on the hemodynamic parameters. Thus, cyclic bending should be considered to mimic the realistic hemodynamics in future patient-specific coronary hemodynamics studies.
- 5 January 2023
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 22 (2) , 729-738
Impact of cyclic bending on coronary hemodynamics
It remains unknown that the degree of bias in computational fluid dynamics results without considering coronary cyclic bending. This study aims to investigate the influence of different rates of coronary cyclic bending on coronary hemodynamics. To model coronary bending, a multi-ring-controlled fluid–structural interaction model was designed. A coronary artery was simulated with various cyclic bending rates (0.5, 0.75 and 1 s, corresponding to heart rates of 120, 80 and 60 bpm) and compared against a stable model. The simulated results show that the hemodynamic parameters of vortex Q-criterion, temporal wall shear stress (WSS), time-averaged WSS (TaWSS) and oscillatory shear index (OSI) were sensitive to the changes in cyclic rate. A higher heart rate resulted in higher magnitude and larger variance in the hemodynamic parameters. Whereas, the values and distributions of flow velocity and relative residence time (RRT) did not show significant differences between different bending periods. This study suggests that a stable coronary model is not sufficient to represent the hemodynamics in a bending coronary artery. Different heart rate conditions were found to have significant impact on the hemodynamic parameters. Thus, cyclic bending should be considered to mimic the realistic hemodynamics in future patient-specific coronary hemodynamics studies.