Impact of cyclic bending on coronary hemodynamics
Authors:
- Jiaqiu WangJiaqiu Wang
- Runxin FangRFRunxin Fang
- Hao WuHWHao Wu
- Yuqiao XiangYXYuqiao Xiang
- Jessica Benitez MendietaJMJessica Benitez Mendieta
- Phani Kumari ParitalaPPPhani Kumari Paritala
- Zhenya FanZFZhenya Fan
- Haveena AnbananthanHAHaveena Anbananthan
- Jorge Alberto Amaya CatanoJCJorge Alberto Amaya Catano
- Owen Christopher RaffelOROwen Christopher Raffel
- Zhiyong LiZLZhiyong Li
- 5 January 2023
- journal article
- research article
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 22 (2) , 729-738
Abstract
It remains unknown that the degree of bias in computational fluid dynamics results without considering coronary cyclic bending. This study aims to investigate the influence of different rates of coronary cyclic bending on coronary hemodynamics. To model coronary bending, a multi-ring-controlled fluid–structural interaction model was designed. A coronary artery was simulated with various cyclic bending rates (0.5, 0.75 and 1 s, corresponding to heart rates of 120, 80 and 60 bpm) and compared against a stable model. The simulated results show that the hemodynamic parameters of vortex Q-criterion, temporal wall shear stress (WSS), time-averaged WSS (TaWSS) and oscillatory shear index (OSI) were sensitive to the changes in cyclic rate. A higher heart rate resulted in higher magnitude and larger variance in the hemodynamic parameters. Whereas, the values and distributions of flow velocity and relative residence time (RRT) did not show significant differences between different bending periods. This study suggests that a stable coronary model is not sufficient to represent the hemodynamics in a bending coronary artery. Different heart rate conditions were found to have significant impact on the hemodynamic parameters. Thus, cyclic bending should be considered to mimic the realistic hemodynamics in future patient-specific coronary hemodynamics studies.Keywords
Funding Information
- Australian Research Council< (DP200103492)
- National Natural Science Foundation of China (12172089)
This publication has 15 references indexed in Scilit:
- Human coronary plaque wall thickness correlated positively with flow shear stress and negatively with plaque wall stress: an IVUS-based fluid-structure interaction multi-patient studyBioMedical Engineering OnLine, 2014
- Effects of Cyclic Motion on Coronary Blood FlowJournal of Biomechanical Engineering, 2013
- Relative residence time and oscillatory shear index of non-Newtonian flow models in aorta2011
- 3D In Vivo IVUS-Based Anisotropic FSI Models With Cyclic Bending for Human Coronary Atherosclerotic Plaque Mechanical Analysis2009
- 3D MRI-Based Anisotropic FSI Models With Cyclic Bending for Human Coronary Atherosclerotic Plaque Mechanical AnalysisJournal of Biomechanical Engineering, 2009
- Fluid–structure interaction analysis of a patient‐specific right coronary artery with physiological velocity and pressure waveformsCommunications in Numerical Methods in Engineering, 2009
- The effect of dynamic vessel motion on haemodynamic parameters in the right coronary artery: a combined MR and CFD studyBritish Journal of Radiology, 2009
- Influence of curvature dynamics on pulsatile coronary artery flow in a realistic bifurcation modelJournal of Biomechanics, 2004
- Spatial comparison between wall shear stress measures and porcine arterial endothelial permeabilityAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- A mesh-updating scheme for hemodynamic simulations in vessels undergoing large deformationsJournal of Engineering Mathematics, 2003