Valerie Lankes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Valerie Lankes has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Coldea
Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
3 shared publications - Bogna Stawarczyk
Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
3 shared publications - John Meinen
Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
2 shared publications Anja Liebermann
Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
1 shared publication- Anja Liebermann
Head of the Department of Prosthetic Dentistry, Faculty of Medicine and University Hospital Cologne, 50931 Cologne, Germany
1 shared publication Bogna Stawarczyk
Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
1 shared publication
Latest Publications
- Open Access
- 26 July 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (8) , 358
Influence of Varying Airborne-Particle Abrasion Angles on Surface Properties and Flexural Strength of Feldspar Ceramic
This study investigated the effects of airborne-particle abrasion angle and nozzle geometry on the surface free energy (SFE), surface roughness (Ra), and flexural strength (FS) of a feldspar ceramic. A total of 70 feldspar ceramic substrates were assigned to seven groups (n = 10). Six groups were air-abraded with 50 µm Al2O3 at 0.05 MPa for 10 s using a conventional nozzle at 20°, 45°, 70°, or 90°, or an experimental conical nozzle at 45° or 90°. The control group underwent hydrofluoric acid etching for 60 s. One-way ANOVA with partial eta-squared (ηp2) was performed, followed by Scheffé post hoc tests. Treatment significantly affected SFE and Ra (p < 0.001). The 20° conventional-nozzle group showed the lowest SFE and Ra values (38.3 ± 11.3 mJ/m2 and 0.514 ± 0.033 µm, respectively). At 45°, the conventional nozzle produced higher SFE than the experimental nozzle, whereas at 90°, the experimental nozzle produced higher Ra. Mean FS ranged from 121 ± 8.5 to 131 ± 8.0 MPa, without significant differences among the groups (p = 0.074). Under the investigated low-pressure conditions, abrasion angle and nozzle geometry altered surface properties without a statistically detectable reduction in FS. Bond strength, aging durability, and clinical performance were not assessed. Therefore, the present findings alone do not justify a recommendation for replacing hydrofluoric-acid etching with airborne-particle abrasion.
- 26 July 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (8) , 358
Open AccessInfluence of Varying Airborne-Particle Abrasion Angles on Surface Properties and Flexural Strength of Feldspar Ceramic
This study investigated the effects of airborne-particle abrasion angle and nozzle geometry on the surface free energy (SFE), surface roughness (Ra), and flexural strength (FS) of a feldspar ceramic. A total of 70 feldspar ceramic substrates were assigned to seven groups (n = 10). Six groups were air-abraded with 50 µm Al2O3 at 0.05 MPa for 10 s using a conventional nozzle at 20°, 45°, 70°, or 90°, or an experimental conical nozzle at 45° or 90°. The control group underwent hydrofluoric acid etching for 60 s. One-way ANOVA with partial eta-squared (ηp2) was performed, followed by Scheffé post hoc tests. Treatment significantly affected SFE and Ra (p < 0.001). The 20° conventional-nozzle group showed the lowest SFE and Ra values (38.3 ± 11.3 mJ/m2 and 0.514 ± 0.033 µm, respectively). At 45°, the conventional nozzle produced higher SFE than the experimental nozzle, whereas at 90°, the experimental nozzle produced higher Ra. Mean FS ranged from 121 ± 8.5 to 131 ± 8.0 MPa, without significant differences among the groups (p = 0.074). Under the investigated low-pressure conditions, abrasion angle and nozzle geometry altered surface properties without a statistically detectable reduction in FS. Bond strength, aging durability, and clinical performance were not assessed. Therefore, the present findings alone do not justify a recommendation for replacing hydrofluoric-acid etching with airborne-particle abrasion.
- Open Access
Airborne-Particle Abrasion vs. Hydrofluoric Acid Etching of Dental Ceramics: Impact on the Tensile Bond Strength
This study evaluated whether airborne-particle abrasion could be an alternative to hydrofluoric acid etching as a pretreatment for the adhesive bonding of silicate ceramic restorations. Feldspar (FEL; n = 100), lithium silicate (LiSi; n = 100), and zirconia (ZrO2; (n = 80) substrates were CAD/CAM-fabricated and airborne-particle-abraded with Al2O3 (25 µm or 50 µm of mean particle size) at pressures of 0.05 or 0.1 MPa. The controls included FEL (60 s) and LiSi (20 s) etched with hydrofluoric acid. The surface free energy (SFE) and roughness (Ra) were measured. For the tensile bond strength (TBS), surfaces were conditioned using a primer (Monobond Plus) and luted to a resin composite (Variolink Esthetic). TBS was assessed initially (24 h, 37 °C water storage) and after thermocycling (5/55 °C, 10,000×). Statistical analysis (SPSS, V29) was performed using a one-way ANOVA, post hoc Scheffé, and a two-group t-test (p = 0.05). Abrasion with 50 µm and 0.1 MPa induced the highest Ra values across the materials (62.5 ± 3.88 µm). ZrO2 exhibited a higher TBS (35.4–49.5 MPa) than FEL and LiSi. For aged LiSi, the specimens treated at 0.1 MPa showed a higher TBS (18.7 ± 9.0 MPa) than those treated at 0.05 MPa, regardless of the particle size. The etched and aged FEL showed a higher SFE but a lower TBS compared to abrasion. Al2O3 particle abrasion (25 or 50 µm at 0.1 MPa) may replace etching for silicate-based ceramics, while 50 µm is recommended for ZrO2 at either pressure.
Open AccessAirborne-Particle Abrasion vs. Hydrofluoric Acid Etching of Dental Ceramics: Impact on the Tensile Bond Strength
This study evaluated whether airborne-particle abrasion could be an alternative to hydrofluoric acid etching as a pretreatment for the adhesive bonding of silicate ceramic restorations. Feldspar (FEL; n = 100), lithium silicate (LiSi; n = 100), and zirconia (ZrO2; (n = 80) substrates were CAD/CAM-fabricated and airborne-particle-abraded with Al2O3 (25 µm or 50 µm of mean particle size) at pressures of 0.05 or 0.1 MPa. The controls included FEL (60 s) and LiSi (20 s) etched with hydrofluoric acid. The surface free energy (SFE) and roughness (Ra) were measured. For the tensile bond strength (TBS), surfaces were conditioned using a primer (Monobond Plus) and luted to a resin composite (Variolink Esthetic). TBS was assessed initially (24 h, 37 °C water storage) and after thermocycling (5/55 °C, 10,000×). Statistical analysis (SPSS, V29) was performed using a one-way ANOVA, post hoc Scheffé, and a two-group t-test (p = 0.05). Abrasion with 50 µm and 0.1 MPa induced the highest Ra values across the materials (62.5 ± 3.88 µm). ZrO2 exhibited a higher TBS (35.4–49.5 MPa) than FEL and LiSi. For aged LiSi, the specimens treated at 0.1 MPa showed a higher TBS (18.7 ± 9.0 MPa) than those treated at 0.05 MPa, regardless of the particle size. The etched and aged FEL showed a higher SFE but a lower TBS compared to abrasion. Al2O3 particle abrasion (25 or 50 µm at 0.1 MPa) may replace etching for silicate-based ceramics, while 50 µm is recommended for ZrO2 at either pressure.
- Open Access
Three-Dimensional Printed Resin: Impact of Different Cleaning Protocols on Degree of Conversion and Tensile Bond Strength to a Composite Resin Using Various Adhesive Systems
The present investigation tested the effect of cleaning methods and adhesives on the tensile bond strength (TBS) of a resin-based composite luted to a temporary 3D printed resin. Substrates (n= 360) were printed using a Rapidshape D20II and cleaned with a butyldiglycol-based solution, isopropanol, or by centrifugation. Specimens were air-abraded with Al2O3 (mean particle size 50 µm) at 0.1 MPa followed by pretreatment (n = 30/subgroup) with: (1) Clearfil Ceramic Primer (CCP); (2) Clearfil Universal Bond (CUB); (3) Scotchbond Universal Plus (SUP) or 4. Visio.link (VL) and luted to PanaviaV5. TBS (n = 15/subgroup) was measured initially (24 h at 37 °C water) or after thermal cycling (10,000×, 5/55 °C). The degree of conversion (DC) for each cleaning method was determined prior and after air-abrasion. Univariate ANOVA followed by post-hoc Scheffé test was computed (p < 0.05). Using Ciba-Geigy tables and chi-square, failure types were analyzed. The DC values were >85% after all cleaning methods, with centrifugation showing the lowest. CCP pretreatment exhibited the lowest TBS values, with predominantly adhesive failures. The combination of CCP and centrifugation increased the TBS values (p < 0.001) compared to the chemical cleaning. CUB, SUP, and VL, regardless of cleaning, can increase the bond strength between the 3D printed resin and the conventional luting resin.
Open AccessThree-Dimensional Printed Resin: Impact of Different Cleaning Protocols on Degree of Conversion and Tensile Bond Strength to a Composite Resin Using Various Adhesive Systems
The present investigation tested the effect of cleaning methods and adhesives on the tensile bond strength (TBS) of a resin-based composite luted to a temporary 3D printed resin. Substrates (n= 360) were printed using a Rapidshape D20II and cleaned with a butyldiglycol-based solution, isopropanol, or by centrifugation. Specimens were air-abraded with Al2O3 (mean particle size 50 µm) at 0.1 MPa followed by pretreatment (n = 30/subgroup) with: (1) Clearfil Ceramic Primer (CCP); (2) Clearfil Universal Bond (CUB); (3) Scotchbond Universal Plus (SUP) or 4. Visio.link (VL) and luted to PanaviaV5. TBS (n = 15/subgroup) was measured initially (24 h at 37 °C water) or after thermal cycling (10,000×, 5/55 °C). The degree of conversion (DC) for each cleaning method was determined prior and after air-abrasion. Univariate ANOVA followed by post-hoc Scheffé test was computed (p < 0.05). Using Ciba-Geigy tables and chi-square, failure types were analyzed. The DC values were >85% after all cleaning methods, with centrifugation showing the lowest. CCP pretreatment exhibited the lowest TBS values, with predominantly adhesive failures. The combination of CCP and centrifugation increased the TBS values (p < 0.001) compared to the chemical cleaning. CUB, SUP, and VL, regardless of cleaning, can increase the bond strength between the 3D printed resin and the conventional luting resin.
- Open Access
- 28 November 2022
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 27 (1) , 31-43
Bond strength between temporary 3D printable resin and conventional resin composite: influence of cleaning methods and air-abrasion parameters
Objectives: The influence of different cleaning methods, air-abrasion parameters, and aging on shear bond strength (SBS) and tensile bond strength (TBS) of 3D resin luted to composite resin. Materials and methods: Nine hundred resin substrates were 3D printed (D20II, Rapid Shape) and cleaned with either isopropanol (ISO), butyldiglycol-based solution (BUT), or centrifugation (CEN). After 24-h storage in 37 °C water, specimens were air-abraded (mean particle size 50 µm; n = 60) with either alumina at 0.1 MPa (AL0.1) or 0.4 MPa (AL0.4) and glass pearls at 0.1 MPa (GP0.1) and 0.4 MPa (GP0.4) or conditioned with visio.link (control) and luted with PanaviaV5. Initially (24 h, 37 °C water storage) or after aging (10,000 thermal cycles), SBS and TBS were measured, and fracture types were examined. Surface free energy (SFE) and roughness (Ra) were determined after air-abrasion. Kolmogorov–Smirnov, Kruskal–Wallis H, Mann–Whitney U, chi-square, and partial eta-squared were computed. Results: SBS measurements presented higher values than TBS (p < 0.001–0.033). Within the pretreatment groups, CEN showed the highest SBS and TBS values compared to cleaning with ISO or BUT (p < 0.001–0.040). Pretreatment with GP0.1 displayed the lowest bond strength values (p < 0.001–0.049), and mostly adhesive fractures occurred. The highest Ra values (p < 0.001) were observed for AL0.4 pretreatment. Conclusions: Pretreatment with AL0.4 and the control group mainly presented the highest bond strength values. Thermocycling had a positive effect on the bond strength. Clinical relevance: According to this study, 3D-printed restorations should be pretreated with AL0.4 or with visio.link before adhesive luting, regardless of their cleaning.
- 28 November 2022
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 27 (1) , 31-43
Open AccessBond strength between temporary 3D printable resin and conventional resin composite: influence of cleaning methods and air-abrasion parameters
Objectives: The influence of different cleaning methods, air-abrasion parameters, and aging on shear bond strength (SBS) and tensile bond strength (TBS) of 3D resin luted to composite resin. Materials and methods: Nine hundred resin substrates were 3D printed (D20II, Rapid Shape) and cleaned with either isopropanol (ISO), butyldiglycol-based solution (BUT), or centrifugation (CEN). After 24-h storage in 37 °C water, specimens were air-abraded (mean particle size 50 µm; n = 60) with either alumina at 0.1 MPa (AL0.1) or 0.4 MPa (AL0.4) and glass pearls at 0.1 MPa (GP0.1) and 0.4 MPa (GP0.4) or conditioned with visio.link (control) and luted with PanaviaV5. Initially (24 h, 37 °C water storage) or after aging (10,000 thermal cycles), SBS and TBS were measured, and fracture types were examined. Surface free energy (SFE) and roughness (Ra) were determined after air-abrasion. Kolmogorov–Smirnov, Kruskal–Wallis H, Mann–Whitney U, chi-square, and partial eta-squared were computed. Results: SBS measurements presented higher values than TBS (p < 0.001–0.033). Within the pretreatment groups, CEN showed the highest SBS and TBS values compared to cleaning with ISO or BUT (p < 0.001–0.040). Pretreatment with GP0.1 displayed the lowest bond strength values (p < 0.001–0.049), and mostly adhesive fractures occurred. The highest Ra values (p < 0.001) were observed for AL0.4 pretreatment. Conclusions: Pretreatment with AL0.4 and the control group mainly presented the highest bond strength values. Thermocycling had a positive effect on the bond strength. Clinical relevance: According to this study, 3D-printed restorations should be pretreated with AL0.4 or with visio.link before adhesive luting, regardless of their cleaning.