ACAndrea Coldea

Andrea Coldea

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrea Coldea has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of Varying Airborne-Particle Abrasion Angles on Surface Properties and Flexural Strength of Feldspar Ceramic

    by Valerie Lankes, Andrea Coldea, John Meinen, Bogna Stawarczyk

    This study investigated the effects of airborne-particle abrasion angle and nozzle geometry on the surface free energy (SFE), surface roughness (Ra), and flexural strength (FS) of a feldspar ceramic. A total of 70 feldspar ceramic substrates were assigned to seven groups (n = 10). Six groups were air-abraded with 50 µm Al2O3 at 0.05 MPa for 10 s using a conventional nozzle at 20°, 45°, 70°, or 90°, or an experimental conical nozzle at 45° or 90°. The control group underwent hydrofluoric acid etching for 60 s. One-way ANOVA with partial eta-squared (ηp2) was performed, followed by Scheffé post hoc tests. Treatment significantly affected SFE and Ra (p < 0.001). The 20° conventional-nozzle group showed the lowest SFE and Ra values (38.3 ± 11.3 mJ/m2 and 0.514 ± 0.033 µm, respectively). At 45°, the conventional nozzle produced higher SFE than the experimental nozzle, whereas at 90°, the experimental nozzle produced higher Ra. Mean FS ranged from 121 ± 8.5 to 131 ± 8.0 MPa, without significant differences among the groups (p = 0.074). Under the investigated low-pressure conditions, abrasion angle and nozzle geometry altered surface properties without a statistically detectable reduction in FS. Bond strength, aging durability, and clinical performance were not assessed. Therefore, the present findings alone do not justify a recommendation for replacing hydrofluoric-acid etching with airborne-particle abrasion.

  • Open Access

    Mechanical Properties of Novel 3D-Printed Restorative Materials for Definitive Dental Applications

    by Moritz Hoffmann, Andrea Coldea, Bogna Stawarczyk

    The aim of this study is to evaluate the mechanical properties and long-term stability of 3D-printable resins for permanent fixed dental prostheses (FDPs), focusing on whether material performance is influenced by 3D-printer type or by differences in resin formulations. Specimens (N = 621) were printed. CAD/CAM blocks (BRILLIANT Crios) served as control. Flexural strength (FS) with elastic modulus (E_calc), Weibull modulus (m), Martens’ hardness (HM), indentation modulus (EIT), elastic modulus (E_RFDA), shear modulus (G_RFDA), and Poisson’s Ratio (ν) were measured initially, after water storage (24 h, 37 °C), and after thermocycling (5–55 °C, 10,000×). SEM analysis assessed microstructure. Data were analyzed using Kolmogorov–Smirnov, ANOVA with Scheffe post hoc, Kruskal–Wallis with Mann–Whitney U, and Weibull statistics with maximum likelihood (α = 0.05). A ceramic crown printed with Midas showed higher FS, HM, and EIT values after thermocycling than with Pro55s, and higher E_calc scores across all aging regimes. A Varseo Smile Crown Plus printed with VarseoXS and AsigaMax showed a higher FS value than TrixPrint2, while AsigaMax achieved the highest initial E_calc and E_RFDA values, and VarseoXS did so after thermocycling. HM, EIT, and G_RFDA were higher for TrixPrint2 and AsigaMax printed specimens, while ν varied by system and aging. 3Delta Crown, printed with AsigaMax, showed the highest FS, E_calc, HM, EIT, and m values after aging. VarseoSmile triniQ and Bridgetec showed the highest E_RFDA and G_RFDA values depending on aging, and Varseo Smile Crown Plus exhibited higher ν initially and post-aging. Printer system and resin formulation significantly influence the mechanical and aging behaviors of 3D-printed FDP materials, underscoring the importance of informed material and printer selection to ensure long-term clinical success.


  • Open Access

    Shrinkage Behavior of Strength-Gradient Multilayered Zirconia Materials

    by Andrea Coldea, John Meinen, Moritz Hoffmann, Adham Elsayed, Bogna Stawarczyk

    To investigate the sintering shrinkage behavior of multigeneration, multilayer zirconia materials using geometrical measurements. Seven zirconia CAD/CAM materials were analyzed, comprising two mono-generation zirconia (HTML: Katana Zr, HTML Plus, 3Y-TZP; UTML: Katana Zr, UTML, 5Y-TZP) and five strength-gradient multilayer zirconia (AIDI: optimill 3D PRO Zir; PRIT: Priti multidisc ZrO2 multicolor; UPCE: Explore Esthetic; ZCPC: IPS e.max ZirCAD Prime; ZYML: Katana YML) materials. Cubes (10 × 10 × 10 mm3) were milled in varying positions within the disks. Geometrical measurements were applied before and after dense sintering using a micrometer screw gauge, light microscopy, as well as surface scans and shrinkages were calculated. Data were analyzed using Kolmogorov–Smirnov, five-way ANOVA followed by the Scheffé post hoc test, and partial eta squared, as well as the Kruskal–Wallis test, including Bonferroni correction (p < 0.05). The highest influence on the shrinkage was exerted by the zirconia material (ηP2 = 0.893, p < 0.001), followed by the test method (ηP2 = 0.175, p < 0.001), while the vertical and horizontal position and measurement point showed no impact on the shrinkage results (p = 0.195–0.763) in the global analysis. Depending on the test method, the pooled shrinkage values of all tested zirconia materials varied between 17.7 and 20.2% for micrometer screw gauge, 17.7 and 20.1% for light microscopy, and 17.8 and 21.1% for surface scan measurements. The shrinkage values measured in the upper, middle, and lower multilayered vertical direction did not differ significantly in the global analysis for the multilayer materials. Therefore, a uniform shrinkage of these strength-gradient multilayer zirconia materials within clinically relevant restorations can be assumed.


  • Open Access

    Mechanical properties of 3D printed denture base polymers

    by Andrea Coldea, Felicitas Mayinger, John Meinen, Moritz Hoffmann, Bogna Stawarczyk


  • Open Access

    Fracture load of feldspar ceramic crowns: effects of surface treatments and aging

    by Andrea Coldea, Bogna Stawarczyk, John Meinen, Valerie Lankes, Michael V. Swain, Malgorzata Roos

    Objectives: To compare the impact of intaglio surface treatments – airborne particle abrasion and hydrofluoric acid (HF) etching – of feldspar ceramic (FEL) crowns on the fracture load (FL) and to investigate the effects of abutment materials and artificial aging. The aim was to assess whether etching could be replaced by an alternative surface roughening method. Materials and methods: FEL crowns had their intaglio surfaces either abraded (25 µm Al2O3, 0.1 MPa), etched (HF, 60 s), or untreated and then bonded to CoCrMo- and polymer-abutments. FL was measured for non-aged and aged (1.2 million mastication cycles) specimens. Data were analyzed using, Weibull modulus, two-/one-way ANOVA with Tukey HSD-post-hoc-test, t-tests, and TOST equivalence (p < 0.05). Results: For crowns bonded to CoCrMo abutments, aging affected the FL and Weibull modulus, but pretreatment methods did not. For initial specimens, airborne abraded and etched crowns were equivalent within a 400N bound, however, for aged specimens, equivalence was inconclusive. For crowns bonded to polymer-abutments, pretreatment and aging influenced the FL. Etching decreased the initial FL by over 420N compared to airborne abraded and untreated specimens. After aging, untreated crowns’ FL decreased by 528N, while airborne abraded and etched specimens showed no aging effect. Conclusions: Airborne particle abrasion of FEL crowns’ intaglio surfaces did not negatively impact FL and was comparable to etched crowns. Conclusions regarding pretreatment methods and aging differed between CoCrMo- and polymer-abutments. Clinical relevance. Airborne particle abrasion may be an alternative procedure for the intaglio surface treatment of FEL crowns prior bonding.


  • Open Access

    Airborne-Particle Abrasion vs. Hydrofluoric Acid Etching of Dental Ceramics: Impact on the Tensile Bond Strength

    by Valerie Lankes, Andrea Coldea, John Meinen, Falk Schwendicke, Bogna Stawarczyk

    This study evaluated whether airborne-particle abrasion could be an alternative to hydrofluoric acid etching as a pretreatment for the adhesive bonding of silicate ceramic restorations. Feldspar (FEL; n = 100), lithium silicate (LiSi; n = 100), and zirconia (ZrO2; (n = 80) substrates were CAD/CAM-fabricated and airborne-particle-abraded with Al2O3 (25 µm or 50 µm of mean particle size) at pressures of 0.05 or 0.1 MPa. The controls included FEL (60 s) and LiSi (20 s) etched with hydrofluoric acid. The surface free energy (SFE) and roughness (Ra) were measured. For the tensile bond strength (TBS), surfaces were conditioned using a primer (Monobond Plus) and luted to a resin composite (Variolink Esthetic). TBS was assessed initially (24 h, 37 °C water storage) and after thermocycling (5/55 °C, 10,000×). Statistical analysis (SPSS, V29) was performed using a one-way ANOVA, post hoc Scheffé, and a two-group t-test (p = 0.05). Abrasion with 50 µm and 0.1 MPa induced the highest Ra values across the materials (62.5 ± 3.88 µm). ZrO2 exhibited a higher TBS (35.4–49.5 MPa) than FEL and LiSi. For aged LiSi, the specimens treated at 0.1 MPa showed a higher TBS (18.7 ± 9.0 MPa) than those treated at 0.05 MPa, regardless of the particle size. The etched and aged FEL showed a higher SFE but a lower TBS compared to abrasion. Al2O3 particle abrasion (25 or 50 µm at 0.1 MPa) may replace etching for silicate-based ceramics, while 50 µm is recommended for ZrO2 at either pressure.


  • Open Access

    Mechanical and physical properties of splint materials for oral appliances produced by additive, subtractive and conventional manufacturing

    by Tina Maleki, John Meinen, Andrea Coldea, Marcel Reymus, Daniel Edelhoff, Bogna Stawarczyk


  • Open Access

    Mechanical Properties of High- and Low-Fusing Zirconia Veneering Ceramics Fired on Different Trays and Substrates

    by Moritz Hoffmann, Andrea Coldea, Mustafa Borga Dönmez, John Meinen, Bogna Stawarczyk

    This study aimed to evaluate the effect of ceramic type, firing tray, and firing substrate on the density, shrinkage, biaxial flexural strength, Martens’ hardness, and elastic indentation modulus of zirconia veneering ceramics. Disk-shaped specimens were fabricated from a high-fusing (HFZ) and a low-fusing (STR) zirconia veneering ceramic. These specimens were then divided into 10 groups according to firing trays (round, small honeycomb-shaped, cordierite [RSC]; round, large honeycomb-shaped, aluminum oxide [RLA]; rectangular, plane, silicon nitride [RCPS]; round, plane, silicon nitride [RPS]; and rectangular, plane, calcium silicate [RCPC]) and firing substrates (firing cotton and platinum foil) used (n = 12). The density, shrinkage, biaxial flexural strength, Martens’ hardness, and indentation modulus were measured, and analyzed with generalized linear model analysis (α = 0.05). The interaction between the ceramic type and firing substrate affected density (p < 0.001), and the other outcomes were affected by the interaction among all main factors (p ≤ 0.045). Higher density was observed with HFZ or platinum foil (p ≤ 0.007). RSC and RLA led to a higher density than RCPS within HFZ and led to the lowest density within STR (p ≤ 0.046). STR had a higher shrinkage (p < 0.001). RSC mostly led to a lower shrinkage of HFZ (p ≤ 0.045). The effect of ceramic type and firing substrates on the biaxial flexural strength, Martens’ hardness, and indentation modulus was minimal while there was no clear trend on the effect of firing tray on these properties. Ceramic type, firing tray, and firing substrate affected the mechanical properties of the tested zirconia veneering ceramics. Firing the tested zirconia veneering ceramics over a round and small honeycomb-shaped cordierite firing tray with firing cotton mostly led to improved mechanical properties.


  • Open Access

    Three-Dimensional Printed Resin: Impact of Different Cleaning Protocols on Degree of Conversion and Tensile Bond Strength to a Composite Resin Using Various Adhesive Systems

    by Valerie Lankes, Marcel Reymus, Felicitas Mayinger, Andrea Coldea, Anja Liebermann, Moritz Hoffmann, Bogna Stawarczyk

    The present investigation tested the effect of cleaning methods and adhesives on the tensile bond strength (TBS) of a resin-based composite luted to a temporary 3D printed resin. Substrates (n= 360) were printed using a Rapidshape D20II and cleaned with a butyldiglycol-based solution, isopropanol, or by centrifugation. Specimens were air-abraded with Al2O3 (mean particle size 50 µm) at 0.1 MPa followed by pretreatment (n = 30/subgroup) with: (1) Clearfil Ceramic Primer (CCP); (2) Clearfil Universal Bond (CUB); (3) Scotchbond Universal Plus (SUP) or 4. Visio.link (VL) and luted to PanaviaV5. TBS (n = 15/subgroup) was measured initially (24 h at 37 °C water) or after thermal cycling (10,000×, 5/55 °C). The degree of conversion (DC) for each cleaning method was determined prior and after air-abrasion. Univariate ANOVA followed by post-hoc Scheffé test was computed (p < 0.05). Using Ciba-Geigy tables and chi-square, failure types were analyzed. The DC values were >85% after all cleaning methods, with centrifugation showing the lowest. CCP pretreatment exhibited the lowest TBS values, with predominantly adhesive failures. The combination of CCP and centrifugation increased the TBS values (p < 0.001) compared to the chemical cleaning. CUB, SUP, and VL, regardless of cleaning, can increase the bond strength between the 3D printed resin and the conventional luting resin.