Noora Matilainen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Noora Matilainen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ilkka Laakso
Aalto University
4 shared publications - Juhani Kataja
Aalto University
2 shared publications Ern Wong
1 shared publication- Hicret Atılgan1 shared publication
Ilkka Laakso
Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
1 shared publicationJanice Koi Jue Xin
1 shared publication
Latest Publications
- Open Access
- 13 February 2025
- Published by Elsevier in Brain Stimulation
- Vol. 18 (2) , 215-224
Locating activation sites of TMS with opposite current directions using probabilistic modelling and biophysical axon models
- 13 February 2025
- Published by Elsevier in Brain Stimulation
- Vol. 18 (2) , 215-224
Open AccessLocating activation sites of TMS with opposite current directions using probabilistic modelling and biophysical axon models
- Open Access
- 3 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (8) , 085004
Verification of neuronavigated TMS accuracy using structured-light 3D scans
Objective. To investigate the reliability and accuracy of the manual three-point co-registration in neuronavigated transcranial magnetic stimulation (TMS). The effect of the error in landmark pointing on the coil placement and on the induced electric and magnetic fields was examined. Approach. The position of the TMS coil on the head was recorded by the neuronavigation system and by 3D scanning for ten healthy participants. The differences in the coil locations and orientations and the theoretical error values for electric and magnetic fields between the neuronavigated and 3D scanned coil positions were calculated. In addition, the sensitivity of the coil location on landmark accuracy was calculated. Main results. The measured distances between the neuronavigated and 3D scanned coil locations were on average 10.2 mm, ranging from 3.1 to 18.7 mm. The error in angles were on average from two to three degrees. The coil misplacement caused on average a 29% relative error in the electric field with a range from 9% to 51%. In the magnetic field, the same error was on average 33%, ranging from 10% to 58%. The misplacement of landmark points could cause a 1.8-fold error for the coil location. Significance. TMS neuronavigation with three landmark points can cause a significant error in the coil position, hampering research using highly accurate electric field calculations. Including 3D scanning to the process provides an efficient method to achieve a more accurate coil position.
- 3 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (8) , 085004
Open AccessVerification of neuronavigated TMS accuracy using structured-light 3D scans
Objective. To investigate the reliability and accuracy of the manual three-point co-registration in neuronavigated transcranial magnetic stimulation (TMS). The effect of the error in landmark pointing on the coil placement and on the induced electric and magnetic fields was examined. Approach. The position of the TMS coil on the head was recorded by the neuronavigation system and by 3D scanning for ten healthy participants. The differences in the coil locations and orientations and the theoretical error values for electric and magnetic fields between the neuronavigated and 3D scanned coil positions were calculated. In addition, the sensitivity of the coil location on landmark accuracy was calculated. Main results. The measured distances between the neuronavigated and 3D scanned coil locations were on average 10.2 mm, ranging from 3.1 to 18.7 mm. The error in angles were on average from two to three degrees. The coil misplacement caused on average a 29% relative error in the electric field with a range from 9% to 51%. In the magnetic field, the same error was on average 33%, ranging from 10% to 58%. The misplacement of landmark points could cause a 1.8-fold error for the coil location. Significance. TMS neuronavigation with three landmark points can cause a significant error in the coil position, hampering research using highly accurate electric field calculations. Including 3D scanning to the process provides an efficient method to achieve a more accurate coil position.
- Open Access
- 22 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015012
Predicting the hotspot location and motor threshold prior to transcranial magnetic stimulation using electric field modelling
Objective. To investigate whether the motor threshold (MT) and the location of the motor hotspot in transcranial magnetic stimulation (TMS) can be predicted with computational models of the induced electric field. Approach. Individualized computational models were constructed from structural magnetic resonance images of ten healthy participants, and the induced electric fields were determined with the finite element method. The models were used to optimize the location and direction of the TMS coil on the scalp to produce the largest electric field at a predetermined cortical target location. The models were also used to predict how the MT changes as the magnetic coil is moved to various locations over the scalp. To validate the model predictions, the motor evoked potentials were measured from the first dorsal interosseous (FDI) muscle with TMS in the ten participants. Both computational and experimental methods were preregistered prior to the experiments. Main results. Computationally optimized hotspot locations were nearly as accurate as those obtained using manual hotspot search procedures. The mean Euclidean distance between the predicted and the measured hotspot locations was approximately 1.3 cm with a 0.8 cm bias towards the anterior direction. Exploratory analyses showed that the bias could be removed by changing the cortical target location that was used for the prediction. The results also indicated a statistically significant relationship ( p < 0.001) between the calculated electric field and the MT measured at several locations on the scalp. Significance. The results show that the individual TMS hotspot can be located using computational analysis without stimulating the subject or patient even once. Adapting computational modelling would save time and effort in research and clinical use of TMS.
- 22 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015012
Open AccessPredicting the hotspot location and motor threshold prior to transcranial magnetic stimulation using electric field modelling
Objective. To investigate whether the motor threshold (MT) and the location of the motor hotspot in transcranial magnetic stimulation (TMS) can be predicted with computational models of the induced electric field. Approach. Individualized computational models were constructed from structural magnetic resonance images of ten healthy participants, and the induced electric fields were determined with the finite element method. The models were used to optimize the location and direction of the TMS coil on the scalp to produce the largest electric field at a predetermined cortical target location. The models were also used to predict how the MT changes as the magnetic coil is moved to various locations over the scalp. To validate the model predictions, the motor evoked potentials were measured from the first dorsal interosseous (FDI) muscle with TMS in the ten participants. Both computational and experimental methods were preregistered prior to the experiments. Main results. Computationally optimized hotspot locations were nearly as accurate as those obtained using manual hotspot search procedures. The mean Euclidean distance between the predicted and the measured hotspot locations was approximately 1.3 cm with a 0.8 cm bias towards the anterior direction. Exploratory analyses showed that the bias could be removed by changing the cortical target location that was used for the prediction. The results also indicated a statistically significant relationship ( p < 0.001) between the calculated electric field and the MT measured at several locations on the scalp. Significance. The results show that the individual TMS hotspot can be located using computational analysis without stimulating the subject or patient even once. Adapting computational modelling would save time and effort in research and clinical use of TMS.
- Open Access
- 2 December 2022
- Published by Center for Open Science in PsyArXiv
Functional relevance of the extrastriate body area for visual and haptic object recognition: a preregistered fMRI-guided TMS study
Neuroimaging studies have shown that the lateral occipito-temporal cortex is involved in multisensory object processing. However, how essential this region is for non-visual object processing remains a matter of controversy. In this preregistered fMRI-guided repetitive transcranial magnetic stimulation (rTMS) study, we examined the causal involvement of the extrastriate body area (EBA) in multisensory object recognition. Participants used either vision or haptics to identify three object categories: hands, teapots (tools), and cars (control objects). Continuous theta-burst stimulation (cTBS) was applied over the left EBA, right EBA, or vertex (control site). Performance for visually perceived hands and teapots (relative to cars) was more strongly disrupted by cTBS over the left EBA than over the vertex, whereas no such object-specific effect was observed in haptics. Instead, exploratory analyses showed that the effect of impaired recognition for all object categories was greater when cTBS was applied over the right EBA compared to the vertex. The simulation of the induced electric fields confirmed that the cTBS affected not only EBA but also the adjacent object-sensitive region. These results indicate that the lateral occipito-temporal cortex is functionally relevant for haptic and visual object processing, though the rTMS differently affected object recognition between the two sensory modalities.
- 2 December 2022
- Published by Center for Open Science in PsyArXiv
Open AccessFunctional relevance of the extrastriate body area for visual and haptic object recognition: a preregistered fMRI-guided TMS study
Neuroimaging studies have shown that the lateral occipito-temporal cortex is involved in multisensory object processing. However, how essential this region is for non-visual object processing remains a matter of controversy. In this preregistered fMRI-guided repetitive transcranial magnetic stimulation (rTMS) study, we examined the causal involvement of the extrastriate body area (EBA) in multisensory object recognition. Participants used either vision or haptics to identify three object categories: hands, teapots (tools), and cars (control objects). Continuous theta-burst stimulation (cTBS) was applied over the left EBA, right EBA, or vertex (control site). Performance for visually perceived hands and teapots (relative to cars) was more strongly disrupted by cTBS over the left EBA than over the vertex, whereas no such object-specific effect was observed in haptics. Instead, exploratory analyses showed that the effect of impaired recognition for all object categories was greater when cTBS was applied over the right EBA compared to the vertex. The simulation of the induced electric fields confirmed that the cTBS affected not only EBA but also the adjacent object-sensitive region. These results indicate that the lateral occipito-temporal cortex is functionally relevant for haptic and visual object processing, though the rTMS differently affected object recognition between the two sensory modalities.
- Open Access
- 22 March 2022
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 16, 845476
The Effect of Inter-pulse Interval on TMS Motor Evoked Potentials in Active Muscles
Objective: The time interval between transcranial magnetic stimulation (TMS) pulses affects evoked muscle responses when the targeted muscle is resting. This necessitates using sufficiently long inter-pulse intervals (IPIs). However, there is some evidence that the IPI has no effect on the responses evoked in active muscles. Thus, we tested whether voluntary contraction could remove the effect of the IPI on TMS motor evoked potentials (MEPs).Methods: In our study, we delivered sets of 30 TMS pulses with three different IPIs (2, 5, and 10 s) to the left primary motor cortex. These measurements were performed with the resting and active right hand first dorsal interosseous muscle in healthy participants (N = 9 and N = 10). MEP amplitudes were recorded through electromyography.Results: We found that the IPI had no significant effect on the MEP amplitudes in the active muscle (p = 0.36), whereas in the resting muscle, the IPI significantly affected the MEP amplitudes (p < 0.001), decreasing the MEP amplitude of the 2 s IPI.Conclusions: These results show that active muscle contraction removes the effect of the IPI on the MEP amplitude. Therefore, using active muscles in TMS motor mapping enables faster delivery of TMS pulses, reducing measurement time in novel TMS motor mapping studies.
- 22 March 2022
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 16, 845476
Open AccessThe Effect of Inter-pulse Interval on TMS Motor Evoked Potentials in Active Muscles
Objective: The time interval between transcranial magnetic stimulation (TMS) pulses affects evoked muscle responses when the targeted muscle is resting. This necessitates using sufficiently long inter-pulse intervals (IPIs). However, there is some evidence that the IPI has no effect on the responses evoked in active muscles. Thus, we tested whether voluntary contraction could remove the effect of the IPI on TMS motor evoked potentials (MEPs).Methods: In our study, we delivered sets of 30 TMS pulses with three different IPIs (2, 5, and 10 s) to the left primary motor cortex. These measurements were performed with the resting and active right hand first dorsal interosseous muscle in healthy participants (N = 9 and N = 10). MEP amplitudes were recorded through electromyography.Results: We found that the IPI had no significant effect on the MEP amplitudes in the active muscle (p = 0.36), whereas in the resting muscle, the IPI significantly affected the MEP amplitudes (p < 0.001), decreasing the MEP amplitude of the 2 s IPI.Conclusions: These results show that active muscle contraction removes the effect of the IPI on the MEP amplitude. Therefore, using active muscles in TMS motor mapping enables faster delivery of TMS pulses, reducing measurement time in novel TMS motor mapping studies.