Suham Towfiq Ameen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Suham Towfiq Ameen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Khudhair Hassan
Department of Chemistry, College of Science, Baghdad University, Baghdad, Iraq
2 shared publications - Bahruddin Saad
School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia
2 shared publications - Afidah Abdul Rahim
School of Chemical Sciences, Universiti Sains Malaysia, 11800 USM, P. Pinang, Malaysia
1 shared publication - Marina Mokhtar
School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia
1 shared publication - Norariza Ahmad
School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia
1 shared publication - Rohana Adnan
School of Chemical Sciences Universiti Sains Malaysia Pulau Pinang Malaysia
1 shared publication
Latest Publications
- Open Access
- 1 February 2017
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 10, S1484-S1491
Tetracaine – selective electrodes with polymer membranes and their application in pharmaceutical formulation control
The construction and electrochemical response characteristics of poly(vinyl chloride) (PVC) membrane electrodes for tetracaine hydrochloride (TCH) are described. The sensing membranes incorporating ion-association complexes of tetracaine cation with phosphotungstic acid (PTA) or phosphomolybdic acid (PMA) or Sodium tetraphenyl borate (NaTPB) as electroactive materials and di-n-butyl phthalate (DBPH) or tri-n-butyl phosphate (TBP) as a plasticizer in PVC matrixes were evaluated. The results obtained show the electrodes based on PTA or PMA as electroactive compounds and DBPH as plasticizer with a fast, stable and near-Nernstian response over a wide concentration range (1 × 10−5–5 × 10−2 M), with cationic slopes of 55.02 and 52.05 mV decade−1 over a pH range of (2.5–6.5). The electrodes show good discrimination of tetracaine from several inorganic cations and sugars. The electrodes were successfully applied for the determination of tetracaine in pharmaceutical formulations.
- 1 February 2017
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 10, S1484-S1491
Open AccessTetracaine – selective electrodes with polymer membranes and their application in pharmaceutical formulation control
The construction and electrochemical response characteristics of poly(vinyl chloride) (PVC) membrane electrodes for tetracaine hydrochloride (TCH) are described. The sensing membranes incorporating ion-association complexes of tetracaine cation with phosphotungstic acid (PTA) or phosphomolybdic acid (PMA) or Sodium tetraphenyl borate (NaTPB) as electroactive materials and di-n-butyl phthalate (DBPH) or tri-n-butyl phosphate (TBP) as a plasticizer in PVC matrixes were evaluated. The results obtained show the electrodes based on PTA or PMA as electroactive compounds and DBPH as plasticizer with a fast, stable and near-Nernstian response over a wide concentration range (1 × 10−5–5 × 10−2 M), with cationic slopes of 55.02 and 52.05 mV decade−1 over a pH range of (2.5–6.5). The electrodes show good discrimination of tetracaine from several inorganic cations and sugars. The electrodes were successfully applied for the determination of tetracaine in pharmaceutical formulations.
- Open Access
Ionophore-Based Potentiometric Sensors for the Flow-Injection Determination of Promethazine Hydrochloride in Pharmaceutical Formulations and Human Urine
Plasticised poly(vinyl chloride)-based membranes containing the ionophores (α-, β- and γ-cyclodextrins (CD), dibenzo-18-crown-6 (DB18C6) and dibenzo-30-crown-10 (DB30C10) were evaluated for their potentiometric response towards promethazine (PM) in a flow injection analysis (FIA) set-up. Good responses were obtained when β- and γ-CDs, and DB30C10 were used. The performance characteristics were further improved when tetrakis(4-chlorophenyl) borate (KTPB) was added to the membrane. The sensor based on β-CD, bis(2-ethylhexyl) adipate (BEHA) and KTPB exhibited the best performance among the eighteen sensor compositions that were tested. The response was linear from 1 x 10−5 to 1 x 10−2 M, slope was 61.3 mV decade−1, the pH independent region ranged from 4.5 to 7.0, a limit of detection of 5.3 x 10−6 M was possible and a lifetime of more than a month was observed when used in the FIA system. Other plasticisers such as dioctyl phenylphosphonate and tributyl phosphate do not show significant improvements in the quality of the sensors. The promising sensors were further tested for the effects of foreign ions (Li+, Na+, K+, Mg2+, Ca2+, Co2+, Cu2+, Cr3+, Fe3+, glucose, fructose). FIA conditions (e.g., effects of flow rate, injection volume, pH of the carrier stream) were also studied when the best sensor was used (based on β-CD). The sensor was applied to the determination of PM in four pharmaceutical preparations and human urine that were spiked with different levels of PM. Good agreement between the sensor and the manufacturer’s claimed values (for pharmaceutical preparations) was obtained, while mean recoveries of 98.6% were obtained for spiked urine samples. The molecular recognition features of the sensors as revealed by molecular modelling were rationalised by the nature of the interactions and complexation energies between the host and guest molecules.
Open AccessIonophore-Based Potentiometric Sensors for the Flow-Injection Determination of Promethazine Hydrochloride in Pharmaceutical Formulations and Human Urine
Plasticised poly(vinyl chloride)-based membranes containing the ionophores (α-, β- and γ-cyclodextrins (CD), dibenzo-18-crown-6 (DB18C6) and dibenzo-30-crown-10 (DB30C10) were evaluated for their potentiometric response towards promethazine (PM) in a flow injection analysis (FIA) set-up. Good responses were obtained when β- and γ-CDs, and DB30C10 were used. The performance characteristics were further improved when tetrakis(4-chlorophenyl) borate (KTPB) was added to the membrane. The sensor based on β-CD, bis(2-ethylhexyl) adipate (BEHA) and KTPB exhibited the best performance among the eighteen sensor compositions that were tested. The response was linear from 1 x 10−5 to 1 x 10−2 M, slope was 61.3 mV decade−1, the pH independent region ranged from 4.5 to 7.0, a limit of detection of 5.3 x 10−6 M was possible and a lifetime of more than a month was observed when used in the FIA system. Other plasticisers such as dioctyl phenylphosphonate and tributyl phosphate do not show significant improvements in the quality of the sensors. The promising sensors were further tested for the effects of foreign ions (Li+, Na+, K+, Mg2+, Ca2+, Co2+, Cu2+, Cr3+, Fe3+, glucose, fructose). FIA conditions (e.g., effects of flow rate, injection volume, pH of the carrier stream) were also studied when the best sensor was used (based on β-CD). The sensor was applied to the determination of PM in four pharmaceutical preparations and human urine that were spiked with different levels of PM. Good agreement between the sensor and the manufacturer’s claimed values (for pharmaceutical preparations) was obtained, while mean recoveries of 98.6% were obtained for spiked urine samples. The molecular recognition features of the sensors as revealed by molecular modelling were rationalised by the nature of the interactions and complexation energies between the host and guest molecules.