Wei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wei Wang has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Guoming Ma
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
6 shared publications - Houxian Du
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources and Beijing Key Laboratory of High Voltage and EMC, North China Electric Power University, Beijing, China
3 shared publications - Biqian Xu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
2 shared publications - Hao Liu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
2 shared publications - Sihan Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
2 shared publications - Weiqi Qin
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
2 shared publications
Latest Publications
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (7) , 10350-10357
Design and Laboratory Evaluation of a Distributed Vibration Detection Method for Power Transformers Using COTDR and Mandrel-Type Fiber Optic Sensors
The vibration signal analysis method can detect transformer vibration signals and diagnose mechanical faults non-invasively. A high-sensitivity mandrel-type fiber optic sensor for distributed detection of vibration signals on transformer surfaces was presented in this paper, based on coherent optical time domain reflectometry (COTDR). Firstly, the influence of the mandrel structure, dimensions, and materials on sensitivity was investigated through finite element simulation and experiments. The sensitivity enhancement method for the mandrel sensor was derived, which led to the determination of the most sensitive sensor manufacturing scheme. Then, through experimental verification, sensor achieved a sensitivity of 20.50 rad/g, with a detectable vibration frequency range of 100 Hz to 1 kHz and a minimum detectable acceleration of 0.01 g, which is the possible minimum value of the transformer vibration signal. Experimental verification confirmed that the sensor array enables distributed detection over 5 km of sensing optical fiber, supporting simultaneous monitoring at 100 measurement points. Additionally, a differential-unwrapping-integration (DUI) algorithm was introduced to address the issue of high-frequency, large-amplitude vibration signal wrapping in the digital domain.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (7) , 10350-10357
Design and Laboratory Evaluation of a Distributed Vibration Detection Method for Power Transformers Using COTDR and Mandrel-Type Fiber Optic Sensors
The vibration signal analysis method can detect transformer vibration signals and diagnose mechanical faults non-invasively. A high-sensitivity mandrel-type fiber optic sensor for distributed detection of vibration signals on transformer surfaces was presented in this paper, based on coherent optical time domain reflectometry (COTDR). Firstly, the influence of the mandrel structure, dimensions, and materials on sensitivity was investigated through finite element simulation and experiments. The sensitivity enhancement method for the mandrel sensor was derived, which led to the determination of the most sensitive sensor manufacturing scheme. Then, through experimental verification, sensor achieved a sensitivity of 20.50 rad/g, with a detectable vibration frequency range of 100 Hz to 1 kHz and a minimum detectable acceleration of 0.01 g, which is the possible minimum value of the transformer vibration signal. Experimental verification confirmed that the sensor array enables distributed detection over 5 km of sensing optical fiber, supporting simultaneous monitoring at 100 measurement points. Additionally, a differential-unwrapping-integration (DUI) algorithm was introduced to address the issue of high-frequency, large-amplitude vibration signal wrapping in the digital domain.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Ultrasonic Fiber-Optic Sensor With Graphene-Silver Composite Diaphragm for Transformer Monitoring
In the field of optical ultrasonic sensing for transformers, probe-type sensors face challenges such as limited sensitivity. In this study, we proposed a fiber optic ultrasonic sensor with a composite diaphragm structure. Based on the design of the sensing membrane and cavity structure, the system achieved highly sensitive ultrasonic sensing suitable for transformer tank applications. A graphene-silver composite film (20 nm/200 nm) served as the sensing diaphragm, while insulating materials formed a compact ultrasonic probe. The cavity length of the probe was meticulously optimized to ensure optimal performance. The transducer’s performance was experimentally evaluated in transformer oil. Results showed that it maintained stable performance, achieving a minimum detectable pressure of 3.8 mPa and an ultrasonic sensitivity of 802.2 nm/kPa. The proposed device exhibited superior average sensitivity and frequency response compared with conventional piezoelectric transducers over a broad frequency range of 20-300 kHz. Its compact structure, immunity to electromagnetic interference, and real-time demodulation capability offered an innovative solution for ultrasonic inspection of power transformers.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Ultrasonic Fiber-Optic Sensor With Graphene-Silver Composite Diaphragm for Transformer Monitoring
In the field of optical ultrasonic sensing for transformers, probe-type sensors face challenges such as limited sensitivity. In this study, we proposed a fiber optic ultrasonic sensor with a composite diaphragm structure. Based on the design of the sensing membrane and cavity structure, the system achieved highly sensitive ultrasonic sensing suitable for transformer tank applications. A graphene-silver composite film (20 nm/200 nm) served as the sensing diaphragm, while insulating materials formed a compact ultrasonic probe. The cavity length of the probe was meticulously optimized to ensure optimal performance. The transducer’s performance was experimentally evaluated in transformer oil. Results showed that it maintained stable performance, achieving a minimum detectable pressure of 3.8 mPa and an ultrasonic sensitivity of 802.2 nm/kPa. The proposed device exhibited superior average sensitivity and frequency response compared with conventional piezoelectric transducers over a broad frequency range of 20-300 kHz. Its compact structure, immunity to electromagnetic interference, and real-time demodulation capability offered an innovative solution for ultrasonic inspection of power transformers.
- 13 October 2023
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 52 (3) , 1518-1530
Cut‐set matrix methods for frequency response analysis curves of lumped parameter equivalent circuit model of three‐winding power transformer
- 13 October 2023
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 52 (3) , 1518-1530
Cut‐set matrix methods for frequency response analysis curves of lumped parameter equivalent circuit model of three‐winding power transformer
- 27 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 159-163
Method for Measuring Dynamic Resistance of Reactive Switch Circuit Breakers On - line
Reactive power switch circuit breaker is more likely to be ablated than other circuit breakers because of inrush current and punch through voltage when it is on and off capacitive current, as well as closure and overvoltage when it is on and off inductive current and frequent operation. As a result, the switching performance is reduced and the breaking failure occurs. Therefore, this paper designs the main circuit of reactive power switching circuit breaker under laboratory conditions according to the voltage waveform changes in the actual breaking process of reactive power switching circuit breaker, establishes the simulation platform of reactive power switching circuit breaker breaking test, and uses the non-contact measurement dynamic resistance curve of reactive power switching circuit breaker breaking process to carry out a refined evaluation of the status of the arc extinguishing chamber of reactive power switching circuit breaker.
- 27 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 159-163
Method for Measuring Dynamic Resistance of Reactive Switch Circuit Breakers On - line
Reactive power switch circuit breaker is more likely to be ablated than other circuit breakers because of inrush current and punch through voltage when it is on and off capacitive current, as well as closure and overvoltage when it is on and off inductive current and frequent operation. As a result, the switching performance is reduced and the breaking failure occurs. Therefore, this paper designs the main circuit of reactive power switching circuit breaker under laboratory conditions according to the voltage waveform changes in the actual breaking process of reactive power switching circuit breaker, establishes the simulation platform of reactive power switching circuit breaker breaking test, and uses the non-contact measurement dynamic resistance curve of reactive power switching circuit breaker breaking process to carry out a refined evaluation of the status of the arc extinguishing chamber of reactive power switching circuit breaker.
- Open Access
- 2 December 2022
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (2) , 412-420
A low‐cost and high‐performance self‐trigger method for high‐voltage transient measurement
Stable triggering of acquisition devices is critical to accurately measure electromagnetic transients, especially for very fast transient overvoltages (VFTOs). A highly stable and low‐cos t self‐trigger method for transient measurement is proposed. An integrated low‐voltage arm module was developed to synchronously realise the triggering and VFTO measurement. The trigger branch was developed using a high‐pass filter. This component obtained the high‐frequency component of the VFTO to trigger the oscilloscope. The trigger branch was integrated with the measurement branch through an impedance converter. An attenuator was implemented before the impedance converter to avoid overvoltage damage to the chip. The circuit parameters of the attenuator were optimised to alleviate the disturbance of the measurement branch. The calibration results demonstrated that the ±1 dB bandwidth of the measurement branch in this system ranged from 11.8 Hz to 105 MHz. The low cutoff frequency of the trigger branch was 710 Hz. The VFTO waveforms generated by the operation of a disconnector in a real 252 kV gas insulated switchgear were measured using the proposed system. The test results verified that the self‐trigger measurement system can provide stable trigger signals and accurately measure the VFTO waveforms.
- 2 December 2022
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 8 (2) , 412-420
Open AccessA low‐cost and high‐performance self‐trigger method for high‐voltage transient measurement
Stable triggering of acquisition devices is critical to accurately measure electromagnetic transients, especially for very fast transient overvoltages (VFTOs). A highly stable and low‐cos t self‐trigger method for transient measurement is proposed. An integrated low‐voltage arm module was developed to synchronously realise the triggering and VFTO measurement. The trigger branch was developed using a high‐pass filter. This component obtained the high‐frequency component of the VFTO to trigger the oscilloscope. The trigger branch was integrated with the measurement branch through an impedance converter. An attenuator was implemented before the impedance converter to avoid overvoltage damage to the chip. The circuit parameters of the attenuator were optimised to alleviate the disturbance of the measurement branch. The calibration results demonstrated that the ±1 dB bandwidth of the measurement branch in this system ranged from 11.8 Hz to 105 MHz. The low cutoff frequency of the trigger branch was 710 Hz. The VFTO waveforms generated by the operation of a disconnector in a real 252 kV gas insulated switchgear were measured using the proposed system. The test results verified that the self‐trigger measurement system can provide stable trigger signals and accurately measure the VFTO waveforms.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fire Ignition Mechanism and Extinguishing Method of Cable in High Voltage Switchgear
In recent years, several serious fire disasters have occurred in high-voltage switchgear. The fire ignition mechanism and extinguishing method is not obtained. Because it is difficult to carry out the cable combustion test in full-size high-voltage switchgear. In this paper, a full-size test platform was built, and the temperature distribution of a switchgear during the electrical induced fire ignition was recorded. Secondly, the simulation model of the switchgear was constructed and the law of fire spread was mastered. Then, the process of cable material decomposition and the effect of material decomposition on cable combustion were analyzed. Finally, the start threshold of a fire extinguishing device was determined based on the temperature field distribution in the test. The results provide a reference for the design of fire extinguishing devices in high voltage switchgear.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fire Ignition Mechanism and Extinguishing Method of Cable in High Voltage Switchgear
In recent years, several serious fire disasters have occurred in high-voltage switchgear. The fire ignition mechanism and extinguishing method is not obtained. Because it is difficult to carry out the cable combustion test in full-size high-voltage switchgear. In this paper, a full-size test platform was built, and the temperature distribution of a switchgear during the electrical induced fire ignition was recorded. Secondly, the simulation model of the switchgear was constructed and the law of fire spread was mastered. Then, the process of cable material decomposition and the effect of material decomposition on cable combustion were analyzed. Finally, the start threshold of a fire extinguishing device was determined based on the temperature field distribution in the test. The results provide a reference for the design of fire extinguishing devices in high voltage switchgear.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1179-1185
Study of the Fitting Method in the Sensitivity Calibration of a HEMP Measuring System
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 62 (4) , 1179-1185
Study of the Fitting Method in the Sensitivity Calibration of a HEMP Measuring System
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 514-516
Detection of arc extinguishing performance of circuit breaker based on radiated electromagnetic waves
The arc extinguishing performance of the circuit breaker make it one of the most important properties. However, there is currently no effective onsite detection method. This paper introduces a detection method based on radiated electromagnetic waves. A simulation platform for the breaking process of the circuit breaker was established. By changing the concentration of SF6, the opening speed and other parameters, the opening process of circuit breakers with different arc extinguishing performance was simulated. The shape of the breaking arc was taken using a high-speed camera, and the electromagnetic wave radiated during the opening process was measured. The test results show that the duration of the radiated electromagnetic wave can well characterize the burning time of the arc in the circuit breaker, and then characterize the arc extinguishing performance of the circuit breaker.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 514-516
Detection of arc extinguishing performance of circuit breaker based on radiated electromagnetic waves
The arc extinguishing performance of the circuit breaker make it one of the most important properties. However, there is currently no effective onsite detection method. This paper introduces a detection method based on radiated electromagnetic waves. A simulation platform for the breaking process of the circuit breaker was established. By changing the concentration of SF6, the opening speed and other parameters, the opening process of circuit breakers with different arc extinguishing performance was simulated. The shape of the breaking arc was taken using a high-speed camera, and the electromagnetic wave radiated during the opening process was measured. The test results show that the duration of the radiated electromagnetic wave can well characterize the burning time of the arc in the circuit breaker, and then characterize the arc extinguishing performance of the circuit breaker.