Denys Kataiev
Denys Kataiev has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Artur Zaporozhets
General Energy Institute of National Academy of Sciences of Ukraine, Kyiv, Ukraine; International Institute for Applied Systems Analysis, Laxenburg, Austria, Ukraine
3 shared publications - Anastasiia Shcherban
Igor Sikorsky Kyiv Polytechnic Institute
1 shared publication - Janusz Kacprzyk
Systems Research Institute, Polish Academy of Sciences
1 shared publication - Mariia Kataieva
General Energy Institute of NAS of Ukraine
1 shared publication National Aviation University
1 shared publication- Volodymyr Kvasnikov
State University «Kyiv Aviation Institute», Ukraine
1 shared publication
Latest Publications
- 26 October 2025
- Published by Springer Nature
- p. 69-82
Method of Increasing the Accuracy of Spatial Coordinates Determining Using a Coordinate-Measuring Arm
- 26 October 2025
- Published by Springer Nature
- p. 69-82
Method of Increasing the Accuracy of Spatial Coordinates Determining Using a Coordinate-Measuring Arm
- Open Access
- 27 February 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2025 (1) , 74-84
DEVELOPMENT OF AN ARTIFICIAL NEURAL NETWORK FOR INFORMATION AND MEASUREMENT SYSTEM FOR CONTROLLING THE GEOMETRIC DIMENSIONS OF POWER EQUIPMENT
The paper deals with the development of an artificial neural network for compensating for nonkinematic errors of an information and measurement system (IMS) based on a coordinate measuring arm (CMA). After compensating for kinematic errors using a mathematical model, the proposed back-propagation neural network corrects non-kinematic errors arising from thermal deformations, noise, and element deformation inaccuracies. Experimental studies conducted on synthetic data demonstrated a significant reduction in the mean square error (MSE) of the coordinates of the measured points and a decrease in measurement uncertainty. The model exhibited high accuracy and stability, which confirms its effectiveness for controlling the geometric parameters of energy equipment. Keywords: artificial neural network, error back propagation, error compensation, information and measurement system, coordinate measuring arm, geometric parameters, modeling.
- 27 February 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2025 (1) , 74-84
Open AccessDEVELOPMENT OF AN ARTIFICIAL NEURAL NETWORK FOR INFORMATION AND MEASUREMENT SYSTEM FOR CONTROLLING THE GEOMETRIC DIMENSIONS OF POWER EQUIPMENT
The paper deals with the development of an artificial neural network for compensating for nonkinematic errors of an information and measurement system (IMS) based on a coordinate measuring arm (CMA). After compensating for kinematic errors using a mathematical model, the proposed back-propagation neural network corrects non-kinematic errors arising from thermal deformations, noise, and element deformation inaccuracies. Experimental studies conducted on synthetic data demonstrated a significant reduction in the mean square error (MSE) of the coordinates of the measured points and a decrease in measurement uncertainty. The model exhibited high accuracy and stability, which confirms its effectiveness for controlling the geometric parameters of energy equipment. Keywords: artificial neural network, error back propagation, error compensation, information and measurement system, coordinate measuring arm, geometric parameters, modeling.
- Open Access
- 16 February 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2024 (1) , 45-53
Method of compensating for instrumental uncertainty in measurements using a coordinate measuring ARM
Due to the influence of dynamic factors in various measurement configurations, the degree of uncertainty in measurements using a Coordinate Measuring Arm (CMA) is directly related to the measurement configuration. However, existing models for compensating CMA errors do not account dynamic factors, which impose certain limits for improving the accuracy of CMAs. To solve this issue, a method for residual error correction based on a polynomial model for single-point measurements was proposed. The influence of the CMA configuration on the residual probe error was analyzed. To enhance accuracy, a polynomial model has been developed by studying the relationship between the rotation angles of the CMA's moving elements and the probe coordinates in a cylindrical coordinate system. Experimental results demonstrate that the residual error correction method significantly compensates for instrumental uncertainty, greatly improving the accuracy of measurements using CMAs.
- 16 February 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2024 (1) , 45-53
Open AccessMethod of compensating for instrumental uncertainty in measurements using a coordinate measuring ARM
Due to the influence of dynamic factors in various measurement configurations, the degree of uncertainty in measurements using a Coordinate Measuring Arm (CMA) is directly related to the measurement configuration. However, existing models for compensating CMA errors do not account dynamic factors, which impose certain limits for improving the accuracy of CMAs. To solve this issue, a method for residual error correction based on a polynomial model for single-point measurements was proposed. The influence of the CMA configuration on the residual probe error was analyzed. To enhance accuracy, a polynomial model has been developed by studying the relationship between the rotation angles of the CMA's moving elements and the probe coordinates in a cylindrical coordinate system. Experimental results demonstrate that the residual error correction method significantly compensates for instrumental uncertainty, greatly improving the accuracy of measurements using CMAs.
- 26 September 2022
- Published by Central Ukrainian National Technical University in Central Ukrainian Scientific Bulletin. Technical Sciences
- Vol. 1 (6(37))
Methods of Increasing the Accuracy of Measuring with the Help of a Coordinate-Measuring Hand
The article has developed algorithms for the control of measuring measuring measures of the measuring and measuring hand for remote measurements. Algorithms for assessing the accuracy of remote measurements of parts with complex geometric shape are proposed. The principle of operation of V-shaped probes is described. A critical analysis of the specification of requirements for accuracy for measuring parts with complex geometric shapes was carried out. The main sources of measurement errors are investigated by means of a coordinate-measuring hand.
- 26 September 2022
- Published by Central Ukrainian National Technical University in Central Ukrainian Scientific Bulletin. Technical Sciences
- Vol. 1 (6(37))
Methods of Increasing the Accuracy of Measuring with the Help of a Coordinate-Measuring Hand
The article has developed algorithms for the control of measuring measuring measures of the measuring and measuring hand for remote measurements. Algorithms for assessing the accuracy of remote measurements of parts with complex geometric shape are proposed. The principle of operation of V-shaped probes is described. A critical analysis of the specification of requirements for accuracy for measuring parts with complex geometric shapes was carried out. The main sources of measurement errors are investigated by means of a coordinate-measuring hand.