HEHamiyet Güngör Erdoğan

Hamiyet Güngör Erdoğan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hamiyet Güngör Erdoğan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Burak Yilmaz

    Department of Reconstructive Dentistry and Gerodontology School of Dental Medicine University of Bern Bern Switzerland

    2 shared publications
  • Mert Keleş

    Department of Periodontology Lokman Hekim University Ankara Turkey

    2 shared publications
  • Adriana da Fonte Porto Carreiro

    Professor, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil

    1 shared publication
  • Ahmet Kürsad Çulhaoğlu

    Department of Prosthodontics, Faculty of Dentistry Health Sciences Gülhane University Ankara Turkey

    1 shared publication
  • Burak Yılmaz

    Department of Reconstructive Dentistry and Gerodontology School of Dental Medicine University of Bern Bern Switzerland

    1 shared publication
  • Cecilia Santos Galvao

    Unifacex - Centro Universitário Facex., Brasil

    1 shared publication

Latest Publications

  • Open Access

    The Bibliometric Analysis of Studies on Color in Prosthodontics Indexed in TR Dizin

    by Hamiyet Güngör, Elizan Demirhan

    Objective: The aim of this bibliometric analysis is to evaluate studies related to color in the field of prosthetic dentistry published in dental journals indexed in the TR Dizin database.Methods: The keyword “color” was searched in both Turkish and English in the TR Dizin database, and all publications directly related to the field of prosthodontics between January 2000 and December 2023 were analyzed. Publications not directly related to prosthodontics, but concerning other areas of dentistry, were excluded from the study. The publications were recorded based on criteria such as journal name, publication year, article type, language, and citation count. The Shapiro-Wilk test was used when the normality assumption was met, and the Mann-Whitney U test and Kruskal-Wallis test were used when the normality assumption was not met. Data were evaluated using IBM SPSS 25 software.Results: The search yielded 4253 publications. After filtering for dental journals, 217 publications related to the field of dentistry were identified, of which 93 were in the field of prosthodontics. The majority of the studies were research articles, and most of them were published in Turkish. It was found that the journal with the highest number of publications was Atatürk University Faculty of Dentistry Journal. The analysis revealed statistically significant differences between publication types, publication languages, and journals (P<.05).Conclusion: The findings suggest that color is an important topic in prosthodontics and that research on this subject continues to increase.Keywords: Bibliometric analysis, dentistry, color, prosthodontics

  • The Effect of Implant Angle and Ti-Base Abutment Height on Monolithic Zirconia Crown Retention

    by Ceren Kendirli, Hamiyet Güngör, Mehmet Ali Kılıçarslan, Lale Karaağaçlıoğlu

    ObjectiveThis study aimed to investigate the effect of using different ti-base heights on retention in implants placed at 0 degrees and 15 degrees. Material and methods Implant analogs were placed in acrylic blocks at two different angles: 0 degrees and 15 degrees. A total of 60 monolithic zirconia crown specimens were produced, with 15 specimens in each group for 30 specimens with a 5.5 mm ti-base support and 30 specimens with a 3.5 mm ti-base support. After the specimens were cemented to the ti-base supports, they were placed in a universal testing machine for a pull-out test. The maximum force used during cementation failure was recorded in newtons (N). Statistical analysis was performed using Welch's ANOVA test to test for a statistically significant difference in Maximum Load (N) between the four different groups, and the Tamhane T2 post-hoc test analysis was used since variance homogeneity was not achieved. Results There was no statistically significant difference between the straight and angled configurations in the abutment groups with a 3.5 mm Ti-base length (p > 0.05). Apart from the comparison of these two groups, the retention force showed a significant difference between the other group pairs. Conclusions In monolithic zirconia restorations supported by Ti-base abutments used with angled or straight implants, groups with longer Ti-base abutment lengths significantly affected crown retention, while groups with shorter Ti-base abutment lengths did not contribute to crown retention. Considering the prosthetic field, selecting the longest Ti-base support height may minimize the risk of restoration dislodgement.

  • Influence of pulp chamber geometry and intraoral scanner on the accuracy of one-piece endodontic crown preparation scans

    by Hamiyet Güngör, Cecilia Santos Galvao, Adriana da Fonte Porto Carreiro, Hyung-In Yoon, Burak Yılmaz

  • Open Access

    Can an increase in abutment screw length enable biomechanical advantages for implants with increased crown height space?

    by Mert Keleş, Hamiyet Güngör Erdoğan, Burak Yılmaz

    Purpose: The purpose of this finite element analysis (FEA) study was to investigate how screw length and crown height affect the stresses generated in the implant‐abutment complex and alveolar bone for anterior single implants and whether the use of longer abutment screw would compensate for increased stresses originated from increased crown height space (CHS). Materials and Methods: A maxillary anterior segment was modeled, and one implant (Straumann bone level implants, 4.1 mm × 12 mm) was placed at the central incisor site. Three different crown heights (11, 13, and 15 mm) with two different abutment screw lengths (regular [R] 7.9 and long [L] 9.9 mm) were modeled, and coded as M 11‐R, M 13‐R, M 15‐R, M 11‐L, M 13‐L, and M 15‐L depending on the height and length, respectively. Horizontal (25.5 N) and 30‐degree oblique forces (178 N) were applied to the crown. The stress magnitude and distribution were evaluated. Results: M 15‐L showed the highest von Mises stress value (869.72 MPa) at the abutment under oblique loads. For both screw lengths, von Mises stress values in the abutment, abutment screw, and inside and outside of the implant walls around the implant platform increased with increased crown height. With the increase in length of the abutment screw, the von Mises stresses decreased in the inside and outside walls of the implant, while the stresses in the abutment increased. Conclusions: Abutment screw length and crown height affected the amount of stress generated on implant components. Increasing the screw length may reduce the stresses on the implant and bone without increasing the stresses in the screw, potentially mitigating the risk of implant platform fractures and bone resorption, both of which are critical failures. Screw related issues may decrease as the area stresses effect has a tendency to reduce when longer screw is used in increased CHS situation (tall crowns).


  • Open Access

    Comparison of stress distribution around splinted and nonsplinted implants with different crown height space in posterior mandible: A finite element analysis study

    by Hamiyet Güngör Erdoğan, Mert Keleş, Burak Yılmaz

    Purpose: The purpose of this finite element analysis (FEA) study was to analyze the stress distribution on prosthetic components of splinted and nonsplinted prostheses, bone, and implants with different crown height space (CHS).Materials and Methods: Mandibular posterior segment was modeled with no resorption at the second premolar site and various amounts of resorption (0, 3, 6, and 9 mm) at the first molar site. Two adjacent implants (Straumann bone level implants, 4.1 mm×8 mm) were placed; at the second premolar site, the crown height was 8 mm and at the first molar site, the crown height varied (8, 11, 14, and 17 mm), depending on the amount of resorption. Both splinted and nonsplinted crowns were designed. Vertical and oblique loads of 400 N were applied to the crowns. von Mises stress was used to evaluate the stress distribution in the implant complex and maximum principal stress was used to evaluate the stress in the bone.Results: When oblique forces were applied, the highest von Mises stresses were observed for nonsplinted crowns in the 17 mm CHS group. The maximum principal and minimum principal stresses observed in bone under oblique loading increased with increased CHS for nonsplinted restorations.Conclusions: Crown height affected the amount of stress in bone and implant components. When the crown height difference between two adjacent implants increases, splinting may be crucial.


  • Open Access

    Effect of Various Beverages on Adhesion of Repaired CAD/CAM Restorative Materials

    by Elif Yiğit, Hamiyet Güngör Erdoğan, Tan Fırat Eyüboğlu, Mutlu Özcan

    (1) Background: The purpose of this study was to determine the effect of commonly consumed beverages on the bond strength of three different computer-aided design-computer-aided manufacturing (CAD/CAM) resin–ceramic hybrid materials repaired with resin-based composite (RBC) materials. (2) Materials and Methods: Rectangular prism specimens (N = 138) measuring 6 mm × 5 mm × 2 mm were obtained from GC Cerasmart (GC), Lava Ultimate (LU), and Vita Enamic (VE) blocks. These blocks were polished and then subjected to thermal cycling (10,000 cycles, 5 °C to 55 °C). After the surface treatment was applied, the average surface roughness value was measured. All the surfaces were repaired with RBC. Thermal cycling was performed for the second time. Each group was then distributed into three subgroups according to the beverage used: tea (t), cola (c), and distilled water (0) (n = 15). The specimens were stored in these solutions for 28 days and then subjected to the shear bond strength (SBS) test. Statistical analysis was performed using a two-way ANOVA test with Bonferroni adjustment. (3) Results: The surface roughness of the materials presented no significant difference after different surface treatments (p > 0.05). No significant difference was observed among the materials (p > 0.05). Tea and cola presented similar SBS values (p > 0.05). Both were significantly lower than distilled water (p < 0.001, p < 0.001, respectively). (4) Conclusions: Consumption of beverages reduces the bond strength in surfaces repaired with RBC to CAD/CAM resin–ceramic hybrid materials. (5) Clinical Significance: Repairing damaged resin matrix dental restorations with RBC is advantageous in terms of time and cost by achieving adequate bond strengths. Frequently consumed beverages reduce the bond strength of repaired CAD/CAM resin–ceramic hybrid materials.


  • Effect of Er:YAG laser on removal of fibre posts from root canal

    by Nihal Özcan, Merve Utar, Ahmet Kürsad Çulhaoğlu, Hamiyet Güngör Erdoğan

    The aim of this study was to evaluate the efficiency of Er:YAG laser in translucent fibre post removal. 60 human single-rooted anterior teeth were divided into three groups (n = 20) according to post diameters (Exacto1-E1, Exacto2-E2, Exacto3-E3) and subdivided according to laser application. Fibre posts were cemented to endodontically treated teeth, and the specimens were sliced with a thickness of 1.0 & PLUSMN; 0.2 mm. Er:YAG laser was applied and the push out bond strength test was performed. Two-way analysis of variance was used to perform the statistical analysis. Push out bond strengths at apical area were significantly lower in all test groups (p < 0.05). Laser application caused increase in all radicular thirds, but it was significant for E1 and E3 groups. Laser application to the post-dentine interface enhances the connection between post and dentine.


  • Open Access

    Effect of different framework materials of resin-bonded bridges on load to fracture values and stress distribution

    by Hamiyet Gungor, Ilgi Baran, Merve Arslan

    Lary canine teeth were used for in vitro part of this study as two groups; metal-reinforced framework (n = 20) [(metal-supported resin-bonded bridge (MR-RB)] and fiber-reinforced frameworks (n = 20) [fiber-reinforced resin-bonded bridge (FR-RB) were prepared for three unit resin-bonded bridges. All bridges were loaded from lateral pontic at 1 mm/min crosshead speed and fracture values were recorded. Mann–Whitney U-test was used for statistical analysis, and fracture patterns were evaluated visually. FEA was carried out in the second part of the study, and stress distribution of MR-RB and FR-RB structures was analyzed using one of the models from in vitro specimens as main model. Results: The mean FSs of MR-RB and FR-RB were 637.47 ± 151.91 N and 224.86 ± 80.97 N, respectively. Fiber-reinforced specimens were found to distribute stress more homogeneous and connectors in each framework were the regions where stress concentrated mostly. Conclusion: In vitro FSs of MR-RB and the stress concentration of the point that the forces were applied were higher as compared to other parts of the restoration. Furthermore, in contrast to FR-RB specimens, retainer tooth fractures were observed in MR-RB specimens....