The Effect of Implant Angle and Ti-Base Abutment Height on Monolithic Zirconia Crown Retention
- 24 June 2026
- journal article
- Published by Adnan Menderes University in Meandros Medical and Dental Journal
- Vol. 27 (2) , 210-218
Abstract
ObjectiveThis study aimed to investigate the effect of using different ti-base heights on retention in implants placed at 0 degrees and 15 degrees. Material and methods Implant analogs were placed in acrylic blocks at two different angles: 0 degrees and 15 degrees. A total of 60 monolithic zirconia crown specimens were produced, with 15 specimens in each group for 30 specimens with a 5.5 mm ti-base support and 30 specimens with a 3.5 mm ti-base support. After the specimens were cemented to the ti-base supports, they were placed in a universal testing machine for a pull-out test. The maximum force used during cementation failure was recorded in newtons (N). Statistical analysis was performed using Welch's ANOVA test to test for a statistically significant difference in Maximum Load (N) between the four different groups, and the Tamhane T2 post-hoc test analysis was used since variance homogeneity was not achieved. Results There was no statistically significant difference between the straight and angled configurations in the abutment groups with a 3.5 mm Ti-base length (p > 0.05). Apart from the comparison of these two groups, the retention force showed a significant difference between the other group pairs. Conclusions In monolithic zirconia restorations supported by Ti-base abutments used with angled or straight implants, groups with longer Ti-base abutment lengths significantly affected crown retention, while groups with shorter Ti-base abutment lengths did not contribute to crown retention. Considering the prosthetic field, selecting the longest Ti-base support height may minimize the risk of restoration dislodgement.Keywords
This publication has 24 references indexed in Scilit:
- Marginal gap of printed, milled, and heat‐pressed two‐piece polyetheretherketone abutments before and after thermal cycling, and their pull‐off bond strength after thermal cyclingJournal of Prosthodontics, 2025
- Long‐term retention and survival of cemented implant‐supported zirconia and metal‐ceramic single crowns: A retrospective studyClinical Oral Implants Research, 2024
- Fracture resistance of hybrid ceramic abutments with different restoration lengths: A pilot studyClinical Implant Dentistry and Related Research, 2024
- Influence of varying titanium base abutment heights on retention of zirconia restorations: An in vitro studyThe Journal of Prosthetic Dentistry, 2023
- Effect of airborne-particle abrasion of a titanium base abutment on the stability of the bonded interface and retention forces of crowns after artificial agingThe Journal of Prosthetic Dentistry, 2021
- Retrospective comparison of posterior fixed dental prostheses supported by two different titanium abutments on tissue level implantsThe Journal of Prosthetic Dentistry, 2021
- Implant Angulation Effect on the Fracture Resistance of Monolithic Zirconia Custom Abutments: An In Vitro StudyJournal of Prosthodontics, 2019
- Effect of CAD/CAM Abutment Height and Cement Type on the Retention of Zirconia CrownsImplant Dentistry, 2018
- The effect of zirconia or titanium as abutment material on soft peri‐implant tissues: a systematic review and meta‐analysisClinical Oral Implants Research, 2015
- Influence of Implant Angulation With Different Crowns on Stress DistributionJournal of Craniofacial Surgery, 2011