Wenhui Zeng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenhui Zeng has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Jiayuan Fan
State Grid Sichuan Economic Research Institute, Chengdu 610041, China
3 shared publications - Junyong Liu
College of Electrical Engineering, Sichuan University, Chengdu 610065, China
3 shared publications - Rongquan Fan
State Grid Sichuan Province Electric Power Company Electric Power Economy Technology Research Institute, Chongqing 610041, China
2 shared publications - Ruirui Huang
College of Electrical Engineering, Sichuan University, Chengdu 610065, China
2 shared publications - Wentao Zhang
State Grid Sichuan Economic Research Institute, Chengdu 610095, China
2 shared publications - Xiao Xu
College of Electrical Engineering, Sichuan University, Chengdu, China
2 shared publications
Latest Publications
- Open Access
Study on the Debris Flow Vulnerability of Mountainous Stilted Frame Structures Based on Progressive Collapse Analysis
To address the progressive collapse of mountainous stilted RC frames induced by debris flows, this study establishes a three-dimensional refined solid model using ABAQUS. The alternate path method (element removal method) is employed to simulate the failure of ground-floor columns under impact, revealing the underlying damage evolution mechanism. The results indicate that the loss of an edge column compromises structural stability significantly more than that of a corner column. Sequential multi-column failure leads to a nonlinear accumulation of damage; specifically, the simultaneous failure of a ‘corner column and its adjacent edge column’ completely severs the outer load-transfer paths, triggering a drastic inward load redistribution. Furthermore, under extreme scenarios, the maximum structural displacement and nodal stress surge to 66.67 mm and 40 MPa, respectively, while the axial force of the core central column jumps by nearly 150% (reaching 2.67 × 106 N). The crushing of internal central columns due to overloading is identified as the critical mechanism triggering global collapse. Based on these findings, design recommendations are proposed, emphasizing the reinforcement of upstream edge columns and the construction of a ‘component-joint-global’ hierarchical defense system.
Open AccessStudy on the Debris Flow Vulnerability of Mountainous Stilted Frame Structures Based on Progressive Collapse Analysis
To address the progressive collapse of mountainous stilted RC frames induced by debris flows, this study establishes a three-dimensional refined solid model using ABAQUS. The alternate path method (element removal method) is employed to simulate the failure of ground-floor columns under impact, revealing the underlying damage evolution mechanism. The results indicate that the loss of an edge column compromises structural stability significantly more than that of a corner column. Sequential multi-column failure leads to a nonlinear accumulation of damage; specifically, the simultaneous failure of a ‘corner column and its adjacent edge column’ completely severs the outer load-transfer paths, triggering a drastic inward load redistribution. Furthermore, under extreme scenarios, the maximum structural displacement and nodal stress surge to 66.67 mm and 40 MPa, respectively, while the axial force of the core central column jumps by nearly 150% (reaching 2.67 × 106 N). The crushing of internal central columns due to overloading is identified as the critical mechanism triggering global collapse. Based on these findings, design recommendations are proposed, emphasizing the reinforcement of upstream edge columns and the construction of a ‘component-joint-global’ hierarchical defense system.
- Open Access
Fault Detection and Classification of Power Lines Based on Bayes–LSTM–Attention
As a critical component of the power system, transmission lines play a significant role in ensuring the safe and stable operation of the power grid. To address the challenge of accurately characterizing complex and diverse fault types, this paper proposes a fault detection and classification method for power lines that integrates Bayesian Reasoning (BR), Long Short-Term Memory (LSTM) networks, and the Attention mechanism. This approach effectively improves the accuracy of fault classification. Bayesian Reasoning is used to adjust the hyperparameters of the LSTM, while the LSTM network processes sequential data efficiently through its gating mechanism. The self-Attention mechanism adaptively assigns weights by focusing on the relationships between information at different positions in the sequence, capturing global dependencies. Test results demonstrate that the proposed Bayes–LSTM–Attention model achieves a fault classification accuracy of 94.5% for transmission lines, a significant improvement compared to the average accuracy of 80% achieved by traditional SVM multi-class classifiers. This indicates that the model has high precision in classifying transmission line faults. Additionally, the evaluation of classification results using the polygon area metric shows that the model exhibits balanced and robust performance in fault classification.
Open AccessFault Detection and Classification of Power Lines Based on Bayes–LSTM–Attention
As a critical component of the power system, transmission lines play a significant role in ensuring the safe and stable operation of the power grid. To address the challenge of accurately characterizing complex and diverse fault types, this paper proposes a fault detection and classification method for power lines that integrates Bayesian Reasoning (BR), Long Short-Term Memory (LSTM) networks, and the Attention mechanism. This approach effectively improves the accuracy of fault classification. Bayesian Reasoning is used to adjust the hyperparameters of the LSTM, while the LSTM network processes sequential data efficiently through its gating mechanism. The self-Attention mechanism adaptively assigns weights by focusing on the relationships between information at different positions in the sequence, capturing global dependencies. Test results demonstrate that the proposed Bayes–LSTM–Attention model achieves a fault classification accuracy of 94.5% for transmission lines, a significant improvement compared to the average accuracy of 80% achieved by traditional SVM multi-class classifiers. This indicates that the model has high precision in classifying transmission line faults. Additionally, the evaluation of classification results using the polygon area metric shows that the model exhibits balanced and robust performance in fault classification.
- Open Access
Experimental Study of Electromagnetic Interference from Concentrated Discharge Channels within the Soil to Adjacent Directly Buried Cables during Lightning Current Inflow to the Ground
Independent lightning rods are often installed in substation grounding systems for lightning protection. The concentrated discharge channel formed when a lightning current flows to the ground through a grounding electrode will cause electromagnetic interference to the directly buried secondary cable. And the three-dimensional structure of the discharge channel will affect the transient electromagnetic field distribution, thereby affecting the electromagnetic transients on cable shields. In order to explore the influence of soil discharge phenomena on the electromagnetic interference of the directly buried secondary cable, in this paper, we carried out experiments on cables in two different grounding modes, single-ended and double-ended grounding, and captured image of soil discharge channels. The results show that the cable grounding mode will affect the coupling mode that causes the shielding layer current. The relative spatial position of the soil discharge channel and the cable has a significant impact on the magnitude of the shielding layer current under both grounding modes. The water content and salt content of the soil also have different degrees of influence on the coupling current of the shielding layer in different grounding modes.
Open AccessExperimental Study of Electromagnetic Interference from Concentrated Discharge Channels within the Soil to Adjacent Directly Buried Cables during Lightning Current Inflow to the Ground
Independent lightning rods are often installed in substation grounding systems for lightning protection. The concentrated discharge channel formed when a lightning current flows to the ground through a grounding electrode will cause electromagnetic interference to the directly buried secondary cable. And the three-dimensional structure of the discharge channel will affect the transient electromagnetic field distribution, thereby affecting the electromagnetic transients on cable shields. In order to explore the influence of soil discharge phenomena on the electromagnetic interference of the directly buried secondary cable, in this paper, we carried out experiments on cables in two different grounding modes, single-ended and double-ended grounding, and captured image of soil discharge channels. The results show that the cable grounding mode will affect the coupling mode that causes the shielding layer current. The relative spatial position of the soil discharge channel and the cable has a significant impact on the magnitude of the shielding layer current under both grounding modes. The water content and salt content of the soil also have different degrees of influence on the coupling current of the shielding layer in different grounding modes.
- Open Access
Whole Life Cycle Cost Analysis of Transmission Lines Using the Economic Life Interval Method
With the large-scale construction and commissioning of transmission lines over the past two decades, the grid is facing a large-scale centralized decommissioning of transmission lines. The transmission line’s economic life is crucial to rationalizing its construction and reducing the grid’s development costs. Based on the minimum economic life calculation principle, the static and dynamic transmission line economic life calculation model is established, considering the whole life cycle for transmission line cost. The improved gray GM (1,1) model is applied to forecast cost data during the economic life assessment of transmission lines with fewer samples. Considering the cost uncertainty in life-cycle costing, the interval cost model based on the coefficient of variation wave amplitude is proposed to determine the economic life intervals under different guarantees by using the normal distribution probability density function, which reduces the influence of cost fluctuations on the economic life calculation error. The economic life analysis of a 500 kV transmission line is used as a case study to verify the model’s accuracy and effectiveness. The method shows the economic life intervals under different guarantee degrees based on the most probable economic life determination, which provides theoretical support for calculating the economic life elasticity of transmission lines.
Open AccessWhole Life Cycle Cost Analysis of Transmission Lines Using the Economic Life Interval Method
With the large-scale construction and commissioning of transmission lines over the past two decades, the grid is facing a large-scale centralized decommissioning of transmission lines. The transmission line’s economic life is crucial to rationalizing its construction and reducing the grid’s development costs. Based on the minimum economic life calculation principle, the static and dynamic transmission line economic life calculation model is established, considering the whole life cycle for transmission line cost. The improved gray GM (1,1) model is applied to forecast cost data during the economic life assessment of transmission lines with fewer samples. Considering the cost uncertainty in life-cycle costing, the interval cost model based on the coefficient of variation wave amplitude is proposed to determine the economic life intervals under different guarantees by using the normal distribution probability density function, which reduces the influence of cost fluctuations on the economic life calculation error. The economic life analysis of a 500 kV transmission line is used as a case study to verify the model’s accuracy and effectiveness. The method shows the economic life intervals under different guarantee degrees based on the most probable economic life determination, which provides theoretical support for calculating the economic life elasticity of transmission lines.
- Open Access
Economic Evaluation Method of Modern Power Transmission System Based on Improved Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) and Best-Worst Method-Anti-Entropy Weight
As the demand for power supply increases, the investment in the power transmission system constantly increases. An accurate economic evaluation of the power transmission system is essential for future investment decisions and management. Applying a single method in economic evaluation leads to excessive subjective consciousness and unreasonable weight allocation. The Euclidean distance in the traditional TOPSIS method only partially works on the condition that the criteria are linearly correlated. To solve these problems, an economic evaluation method based on improved TOPSIS and BWM-anti-entropy weight is proposed. For the assignment of weights, the method retains the advantages of subjective and objective weighting methods based on the Nash equilibrium, breaks through the limitation of utilizing a single method, which contributes to one-sided results, and enhances the scientific rigor and rationality of the comprehensive weighting process. Furthermore, based on comprehensive weights, the method improves the TOPSIS by introducing the Mahalanobis distance and Pearson correlation coefficients, which can eliminate the influence of linear correlation. Finally, ten 500 kV transmission and transformation projects are analyzed and ranked to verify the method’s feasibility. Empirical analysis shows that the method can effectively evaluate the economic benefits of the power transmission system.
Open AccessEconomic Evaluation Method of Modern Power Transmission System Based on Improved Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) and Best-Worst Method-Anti-Entropy Weight
As the demand for power supply increases, the investment in the power transmission system constantly increases. An accurate economic evaluation of the power transmission system is essential for future investment decisions and management. Applying a single method in economic evaluation leads to excessive subjective consciousness and unreasonable weight allocation. The Euclidean distance in the traditional TOPSIS method only partially works on the condition that the criteria are linearly correlated. To solve these problems, an economic evaluation method based on improved TOPSIS and BWM-anti-entropy weight is proposed. For the assignment of weights, the method retains the advantages of subjective and objective weighting methods based on the Nash equilibrium, breaks through the limitation of utilizing a single method, which contributes to one-sided results, and enhances the scientific rigor and rationality of the comprehensive weighting process. Furthermore, based on comprehensive weights, the method improves the TOPSIS by introducing the Mahalanobis distance and Pearson correlation coefficients, which can eliminate the influence of linear correlation. Finally, ten 500 kV transmission and transformation projects are analyzed and ranked to verify the method’s feasibility. Empirical analysis shows that the method can effectively evaluate the economic benefits of the power transmission system.
- Open Access
Risk Reliability Assessment of Transmission Lines under Multiple Natural Disasters in Modern Power Systems
Climate change has led to more frequent extreme weather events, and various natural disasters have posed risks to the operation of transmission lines. Line failures caused by natural disasters are unpredictable and bring additional maintenance work. Therefore, this paper proposes a transmission line risk reliability assessment method that considers the combined effects of multiple natural disasters. This method establishes a theory of disaster risk quantification that considers the probability of the occurrence of the risk, the degree of the impact of the risk on the line, and the severity of the risk disaster. The risk weights for different natural disasters are calculated by combining a hierarchical analysis and entropy weighting methods. The example of a transmission line risk assessment under the combined effects of multiple natural disasters for a Sichuan region verifies the proposed method’s effectiveness. The results show that the method effectively assesses the operational risk to transmission lines under the combined effects of natural disasters. The assessment results can be used for disaster recovery and line risk prevention.
Open AccessRisk Reliability Assessment of Transmission Lines under Multiple Natural Disasters in Modern Power Systems
Climate change has led to more frequent extreme weather events, and various natural disasters have posed risks to the operation of transmission lines. Line failures caused by natural disasters are unpredictable and bring additional maintenance work. Therefore, this paper proposes a transmission line risk reliability assessment method that considers the combined effects of multiple natural disasters. This method establishes a theory of disaster risk quantification that considers the probability of the occurrence of the risk, the degree of the impact of the risk on the line, and the severity of the risk disaster. The risk weights for different natural disasters are calculated by combining a hierarchical analysis and entropy weighting methods. The example of a transmission line risk assessment under the combined effects of multiple natural disasters for a Sichuan region verifies the proposed method’s effectiveness. The results show that the method effectively assesses the operational risk to transmission lines under the combined effects of natural disasters. The assessment results can be used for disaster recovery and line risk prevention.
- Top Cited PapersOpen Access
A Review of Icing and Anti-Icing Technology for Transmission Lines
This paper reviews the application of various advanced anti-icing and de-icing technologies in transmission lines. Introduces the influence of snowing and icing disasters on transmission lines, including a mechanical overload of steel towers, uneven icing or de-icing at different times, Ice-covered conductors galloping and icing flashover of insulators, as well as the icing disasters of transmission lines around the world in recent years. The formation of various icing categories on transmission lines, as well as the effect of meteorological factors, topography, altitude, line direction, suspension height, shape, and electric field on ice-covered transmission lines, are all discussed in this study. The application of various advanced anti/de-icing technologies and their advantages and disadvantages in power transmission lines are summarized. The anti/de-icing of traditional mechanical force, AC/DC short-circuit ice melting, and corona effect is introduced. Torque pendulum and diameter-expanded conductor (DEC) have remarkable anti-icing effects, and the early investment resources are less, the cost is low, and the later maintenance is not needed. In view of some deficiencies of AC and DC ice melting, the current transfer intelligent ice melting device (CTIIMD) can solve the problem well. The gadget has a good effect and high reliability for de-icing conductors in addition to being compact and inexpensive. The application of hydrophobic materials and heating coatings on insulators has a certain anti-icing effect, but the service life needs further research. Optimizing the shed’s construction and arranging several string kinds on the insulators is advisable to prevent icing and the anti-icing flashover effect. In building an insulator, only a different shed layout uses non-consumption energy.
Top Cited PapersOpen AccessA Review of Icing and Anti-Icing Technology for Transmission Lines
This paper reviews the application of various advanced anti-icing and de-icing technologies in transmission lines. Introduces the influence of snowing and icing disasters on transmission lines, including a mechanical overload of steel towers, uneven icing or de-icing at different times, Ice-covered conductors galloping and icing flashover of insulators, as well as the icing disasters of transmission lines around the world in recent years. The formation of various icing categories on transmission lines, as well as the effect of meteorological factors, topography, altitude, line direction, suspension height, shape, and electric field on ice-covered transmission lines, are all discussed in this study. The application of various advanced anti/de-icing technologies and their advantages and disadvantages in power transmission lines are summarized. The anti/de-icing of traditional mechanical force, AC/DC short-circuit ice melting, and corona effect is introduced. Torque pendulum and diameter-expanded conductor (DEC) have remarkable anti-icing effects, and the early investment resources are less, the cost is low, and the later maintenance is not needed. In view of some deficiencies of AC and DC ice melting, the current transfer intelligent ice melting device (CTIIMD) can solve the problem well. The gadget has a good effect and high reliability for de-icing conductors in addition to being compact and inexpensive. The application of hydrophobic materials and heating coatings on insulators has a certain anti-icing effect, but the service life needs further research. Optimizing the shed’s construction and arranging several string kinds on the insulators is advisable to prevent icing and the anti-icing flashover effect. In building an insulator, only a different shed layout uses non-consumption energy.