JMJessica Benitez Mendieta

Jessica Benitez Mendieta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jessica Benitez Mendieta has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fidelity of wall tap pressure measurements in steady and pulsatile flow

    by Tiago Guerzet Sardenberg Lima, Navid Freidoonimehr, Jessica Benitez Mendieta, Haveena Anbananthan, Mingyang Yuan, Han Yu, Yasindu Wickrama Surendra, Zhiyong Li

    Accurate wall pressure measurements quantify pressure gradients in internal flows, yet a flush wall tap is not passive: tap geometry can bias static pressure, and the tap, pressure tubing, and sensor pathway can attenuate pulsatile fluctuations. We quantify wall pressure measurement fidelity over Reynolds numbers up to 704 by separating steady tap effects, dynamic transmission, and sensitivity to as-built geometry in experiments and computational fluid dynamics (CFD). Steady tests evaluated tap diameter bias (0.4, 0.8, and 1.0 mm) and compared CFD on computer-aided design and micro-computed tomography reconstructed lumens. A symmetric phantom with mirrored taps was tested at 1 Hz to quantify attenuation for 0.5 and 1.0 mm taps and two tubing lengths (560 and 2240 mm). The workflow was applied to a patient-specific intracranial aneurysm (IA) phantom with ten taps, fabricated by three-dimensional printing. Steady cases and a sinusoidal case were compared with matched rigid-wall CFD driven by the measured inflow waveform. Tap diameter weakly affected steady differential pressure, but 0.5 mm taps attenuated pulsatile amplitude, while tubing length changed amplitude by <1% at 1 Hz. In the IA phantom, the main discrepancies were in pressure magnitude rather than spatial pattern: CFD captured normalized spatial pressure distributions but underpredicted gauge pressure by 22%–28% in steady flow, pulsatile amplitude by 42%, and peak differential pressure by 15%. These results show that agreement in waveform shape or spatial trends can coexist with large magnitude error unless pressure transmission, as-built geometry, and inlet definition are verified and uncertainties are considered.

  • Open Access

    Haemodynamic characteristics of thin-walled regions in intracranial aneurysms: intraoperative imaging and CFD analysis

    by Haveena Anbananthan, Phani Kumari Paritala, Jessica Benitez Mendieta, Han Yu, Tiago Guerzet Sardenberg Lima, Zoe Dettrick, Ee Shern Liang, Alan Coulthard, Zhi-Yong Li, Craig Winter

    Background: Identifying haemodynamic factors associated with thin-walled regions (TWRs) of intracranial aneurysms is critical for improving pre-surgical rupture risk assessment. Intraoperatively, these regions are visually distinguished by a red, translucent appearance and are considered highly rupture prone. However, current imaging modalities lack the resolution to detect such vulnerable areas preoperatively. This study aimed to determine whether thin-walled regions exhibit distinct local haemodynamic profiles compared to adjacent normal-appearing wall regions. Methods: Sixteen patient-specific models of unruptured middle cerebral artery aneurysms were reconstructed from digital subtraction angiography images. Intraoperative TWRs were identified using a colour segmentation method based on Delta E metrics. Computational fluid dynamics (CFD) simulations were used to compute six haemodynamic parameters: wall shear stress (WSS), time-averaged WSS (TaWSS), oscillatory shear index (OSI), relative residence time (RRT), WSS divergence (WSSD), and pressure. Haemodynamic data were extracted from spatially localised surface patches within confirmed thin and normal regions. Linear mixed-effects models were applied to compare parameters while accounting for patient-level and intra-patient variability, using normalised values to improve model fit. Results: Thin regions exhibited significantly higher WSS, TaWSS, WSSD, and pressure, and reduced RRT. WSS and TaWSS were approximately 3.3% and 2.8% higher in TWRs, respectively. WSSD was 5.4% higher and RRT was 0.3% lower, suggesting faster, more divergent flow in thin regions. Pressure was modestly but significantly elevated at + 1.3%. No significant difference was observed in OSI between regions. Conclusions: Thin-walled regions in intracranial aneurysms demonstrate a distinctive haemodynamic profile characterised by stronger, sustained shear forces, greater shear divergence, and reduced residence time, suggesting a dynamic mechanical environment that promotes focal wall thinning. Our findings suggest that persistent shear-driven stress, rather than oscillatory flow, is a key haemodynamic feature of thin-walled regions and may contribute to localised aneurysm wall vulnerability.


  • Impact of cyclic bending on coronary hemodynamics

    by Jiaqiu Wang, Runxin Fang, Hao Wu, Yuqiao Xiang, Jessica Benitez Mendieta, Phani Kumari Paritala, Zhenya Fan, Haveena Anbananthan, Jorge Alberto Amaya Catano, Owen Christopher Raffel, et al.

    It remains unknown that the degree of bias in computational fluid dynamics results without considering coronary cyclic bending. This study aims to investigate the influence of different rates of coronary cyclic bending on coronary hemodynamics. To model coronary bending, a multi-ring-controlled fluid–structural interaction model was designed. A coronary artery was simulated with various cyclic bending rates (0.5, 0.75 and 1 s, corresponding to heart rates of 120, 80 and 60 bpm) and compared against a stable model. The simulated results show that the hemodynamic parameters of vortex Q-criterion, temporal wall shear stress (WSS), time-averaged WSS (TaWSS) and oscillatory shear index (OSI) were sensitive to the changes in cyclic rate. A higher heart rate resulted in higher magnitude and larger variance in the hemodynamic parameters. Whereas, the values and distributions of flow velocity and relative residence time (RRT) did not show significant differences between different bending periods. This study suggests that a stable coronary model is not sufficient to represent the hemodynamics in a bending coronary artery. Different heart rate conditions were found to have significant impact on the hemodynamic parameters. Thus, cyclic bending should be considered to mimic the realistic hemodynamics in future patient-specific coronary hemodynamics studies.


  • Open Access

    The Need to Shift from Morphological to Structural Assessment for Carotid Plaque Vulnerability

    by Yuqiao Xiang, Xianjue Huang, Jessica Benitez Mendieta, Jiaqiu Wang, Phani Kumari Paritala, Thomas Lloyd, Zhiyong Li

    Degree of luminal stenosis is generally considered to be an important indicator for judging the risk of atherosclerosis burden. However, patients with the same or similar degree of stenosis may have significant differences in plaque morphology and biomechanical factors. This study investigated three patients with carotid atherosclerosis within a similar range of stenosis. Using our developed fluid–structure interaction (FSI) modelling method, this study analyzed and compared the morphological and biomechanical parameters of the three patients. Although their degrees of carotid stenosis were similar, the plaque components showed a significant difference. The distribution range of time-averaged wall shear stress (TAWSS) of patient 2 was wider than that of patient 1 and patient 3. Patient 2 also had a much smaller plaque stress compared to the other two patients. There were significant differences in TAWSS and plaque stresses among three patients. This study suggests that plaque vulnerability is not determined by a single morphological factor, but rather by the combined structure. It is necessary to transform the morphological assessment into a structural assessment of the risk of plaque rupture.


  • Evaluating the Impact of Calcification on Plaque Vulnerability from the Aspect of Mechanical Interaction Between Blood Flow and Artery Based on MRI

    by Jessica Benitez, Davide Fontanarosa, Jiaqiu Wang, Phani Kumari Paritala, Tim McGahan, Thomas Lloyd, Zhiyong Li

    Acute cerebral ischemic events and thrombosis are associated with the rupture/erosion of carotid atherosclerotic plaques. The aim of the present study was to determine the impact of calcification deposition on the wall shear stress (WSS) and stresses within the plaques using 3D fluid–structure interaction (FSI) models. Six patients with calcified carotid atherosclerosis underwent multisequence magnetic resonance imaging (MRI) and were divided into three groups according to the calcification volume. To evaluate the role of the calcification deposition on the stresses, the calcification content was replaced by lipids and arterial tissue, respectively. By comparing the results from the simulation with calcification, and when changing it to lipids there was a significant increment in the stresses at the fibrous cap (p = 0.004). Instead, by changing it to arterial tissue, there was no significant difference (p = 0.07). The calcification shapes that presented the highest stresses were thin concave arc-shaped (AS1) and thin convex arc-shaped (AS3), with mean stress values of 107 ± 54.2 and 99.6 ± 23.4 kPa, respectively. It was also observed that, the calcification shape has more influence on the level of stress than its distance to the lumen. Higher WSS values were associated with the presence of calcification. Calcification shape plays an important role in producing high stresses in the plaque. This work further clarifies the impact of calcification on plaque vulnerability.


  • Optical coherence tomography-based patient-specific coronary artery reconstruction and fluid–structure interaction simulation

    by Jiaqiu Wang, Phani Kumari Paritala, Jessica Benitez Mendieta, Yo Komori, Owen Christopher Raffel, Yuantong Gu, Zhiyong Li

    Plaque rupture is related to the mechanical stress it suffered. The value and distribution of the mechanical stress in plaque could help on assessing plaque vulnerability. To look into the stress conditions in the coronary artery, a patient-specific coronary model was created by using optical coherence tomography (OCT) and angiography imaging data. The reconstructed coronary model consisted of the structure of the lumen, the arterial wall and plaque components. Benefited by the high resolution of OCT, detailed structures such as the thin fibrous cap could be observed and built into the geometry. On this reconstructed coronary model, a fully coupled fluid–structure interaction (FSI) simulation was performed. The principle stress in coronary plaque and the wall shear stress (WSS) were analyzed. The FSI simulation results show that the cap thickness had a significant effect on the stress, and the principle stress at the thin cap area was more than double of those at the locations with a larger thickness. WSS is thought as an important parameter to assess the potentially dangerous areas of the atherosclerosis-prone (caused by low WSS) and the plaque rupture (high WSS). From the WSS plots of our FSI model, the area with abnormal WSS value was detected around the position where a lipid core existed. The FSI simulation results were compared with the results from the conventional structure-only and the computational fluid dynamics (CFD)-only computational models to quantify the difference between the three models. We found little difference in the principle stress results between the FSI and the structure-only model, but a significant difference between the FSI and the CFD-only model when looking into the WSS. The WSS values at the two observation spots from the CFD-only model were higher than the values from the FSI model by 17.95% and 22.66% in average, respectively. Furthermore, the FSI model detected more areas of low WSS, because the fluid domain could expand circumferentially when pressure loaded on the flexible arterial. This study suggests that OCT-based FSI model may be useful for plaque vulnerability assessment and it may be critical to perform the FSI simulation if an accurate WSS value is required.