Ziyu Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ziyu Li has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Karla L. Miller
6 shared publications- Wenchuan Wu
Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
6 shared publications - Qiyuan Tian
School of Biomedical Engineering, Tsinghua University, Beijing, China
4 shared publications - Jonathan R. Polimeni
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States
3 shared publications - Susie Y. Huang
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States
3 shared publications Berkin Bilgic
2 shared publications
Latest Publications
- Open Access
- 3 November 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
SRNR: Deep learning-based MRI super-resolution using noisy high-resolution reference data
Deep learning-based super-resolution (SR) techniques offer a powerful tool to enhance the spatial resolution of magnetic resonance imaging (MRI) without increasing scan time. However, most supervised SR methods rely on high-resolution, high-signal-to-noise ratio (SNR) reference data for training, which are difficult to acquire in many clinical settings, such as in time-constrained pediatric imaging. Inspired by the Noise2Noise principle, we propose SRNR, a new training paradigm that enables supervised SR using noisy high-resolution images as references. SRNR was systematically evaluated on both pediatric and adult simulated data across different noise levels of the reference data. SRNR generated super-resolved image volumes with high similarity to the high-resolution references (PSNR: 32.5–35.2 dB) and improved downstream image analysis performance, including tissue segmentation (white matter Dice coefficient: 0.951–0.960) and cortical surface reconstruction (cortical thickness absolute difference: 0.200–0.255 mm). Furthermore, SRNR was shown to be effective on clinically acquired pediatric brain MRI data, achieving improvements consistent with those observed in the simulated experiments. These results demonstrate that SRNR substantially reduces reliance on clean, high-SNR training data and enables effective SR under clinically realistic acquisition constraints, thereby improving the feasibility of deploying deep learning-based SR in pediatric MRI and related applications.
- 3 November 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Open AccessSRNR: Deep learning-based MRI super-resolution using noisy high-resolution reference data
Deep learning-based super-resolution (SR) techniques offer a powerful tool to enhance the spatial resolution of magnetic resonance imaging (MRI) without increasing scan time. However, most supervised SR methods rely on high-resolution, high-signal-to-noise ratio (SNR) reference data for training, which are difficult to acquire in many clinical settings, such as in time-constrained pediatric imaging. Inspired by the Noise2Noise principle, we propose SRNR, a new training paradigm that enables supervised SR using noisy high-resolution images as references. SRNR was systematically evaluated on both pediatric and adult simulated data across different noise levels of the reference data. SRNR generated super-resolved image volumes with high similarity to the high-resolution references (PSNR: 32.5–35.2 dB) and improved downstream image analysis performance, including tissue segmentation (white matter Dice coefficient: 0.951–0.960) and cortical surface reconstruction (cortical thickness absolute difference: 0.200–0.255 mm). Furthermore, SRNR was shown to be effective on clinically acquired pediatric brain MRI data, achieving improvements consistent with those observed in the simulated experiments. These results demonstrate that SRNR substantially reduces reliance on clean, high-SNR training data and enables effective SR under clinically realistic acquisition constraints, thereby improving the feasibility of deploying deep learning-based SR in pediatric MRI and related applications.
- Open Access
- 9 September 2026
- Published by Elsevier in NeuroImage
- Vol. 341
Improving the accessibility of deep learning-based denoising for accelerated brain MRI using self-supervised learning and/or transfer learning
- 9 September 2026
- Published by Elsevier in NeuroImage
- Vol. 341
Open AccessImproving the accessibility of deep learning-based denoising for accelerated brain MRI using self-supervised learning and/or transfer learning
- Open Access
- 10 October 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 107
Submillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction
- 10 October 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 107
Open AccessSubmillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction
- Open Access
Submillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction
High-resolution diffusion MRI (dMRI) provides valuable insights into brain microstructure, particularly at submillimeter resolutions, where it enables more precise delineations of curved and crossing white matter pathways. However, achieving high-quality submillimeter dMRI in-vivo poses significant challenges due to the intrinsically low signal-to-noise ratio (SNR), along with the long echo spacing, readout time, and TE required for the large matrix size, leading to significant image distortion, T2* blurring, and T2 signal decay. In this study, we propose a novel acquisition and reconstruction framework to overcome these challenges. Based on numerical simulations, we introduce an in-plane segmented 3D multi-slab acquisition that leverages the optimal SNR efficiency of 3D multi-slab imaging while reducing echo spacing, readout times, and TE using in-plane segmentation. This approach minimizes distortion, improves image sharpness, and enhances SNR. Additionally, we develop a denoiser-regularized reconstruction to suppress noise while maintaining data fidelity, which reconstructs high-SNR images without introducing substantial blurring or bias. Comprehensive in-vivo experiments demonstrate that our method consistently produces high-quality dMRI data at 0.65 mm and 0.53 mm isotropic resolutions on a 3T scanner. The submillimeter dMRI datasets reveal richer microstructural details, reduce gyral bias, and improve U-fiber mapping compared to prospectively acquired 1.22 mm diffusion data. Our method demonstrates robustness at 7T and generates high-SNR 0.61 mm diffusion datasets, showing excellent agreement with previous post-mortem studies at the same scanner. Implemented using the open-source, scanner-agnostic framework Pulseq, our approach may facilitate broader adoption across different scanner platforms to benefit a wider range of applications. These results underscore the potential of our method to advance medical image analysis and neuroscientific research on human brain connectivity.
Open AccessSubmillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction
High-resolution diffusion MRI (dMRI) provides valuable insights into brain microstructure, particularly at submillimeter resolutions, where it enables more precise delineations of curved and crossing white matter pathways. However, achieving high-quality submillimeter dMRI in-vivo poses significant challenges due to the intrinsically low signal-to-noise ratio (SNR), along with the long echo spacing, readout time, and TE required for the large matrix size, leading to significant image distortion, T2* blurring, and T2 signal decay. In this study, we propose a novel acquisition and reconstruction framework to overcome these challenges. Based on numerical simulations, we introduce an in-plane segmented 3D multi-slab acquisition that leverages the optimal SNR efficiency of 3D multi-slab imaging while reducing echo spacing, readout times, and TE using in-plane segmentation. This approach minimizes distortion, improves image sharpness, and enhances SNR. Additionally, we develop a denoiser-regularized reconstruction to suppress noise while maintaining data fidelity, which reconstructs high-SNR images without introducing substantial blurring or bias. Comprehensive in-vivo experiments demonstrate that our method consistently produces high-quality dMRI data at 0.65 mm and 0.53 mm isotropic resolutions on a 3T scanner. The submillimeter dMRI datasets reveal richer microstructural details, reduce gyral bias, and improve U-fiber mapping compared to prospectively acquired 1.22 mm diffusion data. Our method demonstrates robustness at 7T and generates high-SNR 0.61 mm diffusion datasets, showing excellent agreement with previous post-mortem studies at the same scanner. Implemented using the open-source, scanner-agnostic framework Pulseq, our approach may facilitate broader adoption across different scanner platforms to benefit a wider range of applications. These results underscore the potential of our method to advance medical image analysis and neuroscientific research on human brain connectivity.
- Open Access
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (2) , 632-644
Self-Navigated 3D Diffusion MRI Using an Optimized CAIPI Sampling and Structured Low-Rank Reconstruction Estimated Navigator
3D multi-slab acquisitions are an appealing approach for diffusion MRI because they are compatible with the imaging regime delivering optimal SNR efficiency. In conventional 3D multi-slab imaging, shot-to-shot phase variations caused by motion pose challenges due to the use of multi-shot k-space acquisition. Navigator acquisition after each imaging echo is typically employed to correct phase variations, which prolongs scan time and increases the specific absorption rate (SAR). The aim of this study is to develop a highly efficient, self-navigated method to correct for phase variations in 3D multi-slab diffusion MRI without explicitly acquiring navigators. The sampling of each shot is carefully designed to intersect with the central kz=0 plane of each slab, and the multi-shot sampling is optimized for self-navigation performance while retaining decent reconstruction quality. The kz=0 intersections from all shots are jointly used to reconstruct a 2D phase map for each shot using a structured low-rank constrained reconstruction that leverages the redundancy in shot and coil dimensions. The phase maps are used to eliminate the shot-to-shot phase inconsistency in the final 3D multi-shot reconstruction. We demonstrate the method’s efficacy using retrospective simulations and prospectively acquired in-vivo experiments at 1.22 mm and 1.09 mm isotropic resolutions. Compared to conventional navigated 3D multi-slab imaging, the proposed self-navigated method achieves comparable image quality while shortening the scan time by 31.7% and improving the SNR efficiency by 15.5%. The proposed method produces comparable quality of DTI and white matter tractography to conventional navigated 3D multi-slab acquisition with a much shorter scan time.
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (2) , 632-644
Open AccessSelf-Navigated 3D Diffusion MRI Using an Optimized CAIPI Sampling and Structured Low-Rank Reconstruction Estimated Navigator
3D multi-slab acquisitions are an appealing approach for diffusion MRI because they are compatible with the imaging regime delivering optimal SNR efficiency. In conventional 3D multi-slab imaging, shot-to-shot phase variations caused by motion pose challenges due to the use of multi-shot k-space acquisition. Navigator acquisition after each imaging echo is typically employed to correct phase variations, which prolongs scan time and increases the specific absorption rate (SAR). The aim of this study is to develop a highly efficient, self-navigated method to correct for phase variations in 3D multi-slab diffusion MRI without explicitly acquiring navigators. The sampling of each shot is carefully designed to intersect with the central kz=0 plane of each slab, and the multi-shot sampling is optimized for self-navigation performance while retaining decent reconstruction quality. The kz=0 intersections from all shots are jointly used to reconstruct a 2D phase map for each shot using a structured low-rank constrained reconstruction that leverages the redundancy in shot and coil dimensions. The phase maps are used to eliminate the shot-to-shot phase inconsistency in the final 3D multi-shot reconstruction. We demonstrate the method’s efficacy using retrospective simulations and prospectively acquired in-vivo experiments at 1.22 mm and 1.09 mm isotropic resolutions. Compared to conventional navigated 3D multi-slab imaging, the proposed self-navigated method achieves comparable image quality while shortening the scan time by 31.7% and improving the SNR efficiency by 15.5%. The proposed method produces comparable quality of DTI and white matter tractography to conventional navigated 3D multi-slab acquisition with a much shorter scan time.
- Open Access
- 18 August 2024
- Published by Wiley in Magnetic Resonance in Medicine
Improved visualization of intracranial distal arteries with multiple 2D slice dynamic ASL‐MRA and super‐resolution convolutional neural network
Purpose: To develop a novel framework to improve the visualization of distal arteries in arterial spin labeling (ASL) dynamic MRA.Methods: The attenuation of ASL blood signal due to the repetitive application of excitation RF pulses was minimized by splitting the acquisition volume into multiple thin 2D (M2D) slices, thereby reducing the exposure of the arterial blood magnetization to RF pulses while it flows within the brain. To improve the degraded vessel visualization in the slice direction due to the limited minimum achievable 2D slice thickness, a super‐resolution (SR) convolutional neural network (CNN) was trained by using 3D time‐of‐flight (TOF)‐MRA images from a large public dataset. And then, we applied domain transfer from 3D TOF‐MRA to M2D ASL‐MRA, while avoiding acquiring a large number of ASL‐MRA data required for CNN training.Results: Compared to the conventional 3D ASL‐MRA, far more distal arteries were visualized with higher signal intensity by using M2D ASL‐MRA. In general, however, the vessel visualization with a conventional interpolation was prone to be blurry and unclear due to the limited spatial resolution in the slice direction, particularly in small vessels. Application of CNN‐based SR transferred from 3D TOF‐MRA to M2D ASL‐MRA successfully addressed such a limitation and achieved clearer visualization of small vessels than conventional interpolation.Conclusion: This study demonstrated that the proposed framework provides improved visualization of distal arteries in later dynamic phases, which will particularly benefit the application of this approach in patients with cerebrovascular disease who have slow blood flow.
- 18 August 2024
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessImproved visualization of intracranial distal arteries with multiple 2D slice dynamic ASL‐MRA and super‐resolution convolutional neural network
Purpose: To develop a novel framework to improve the visualization of distal arteries in arterial spin labeling (ASL) dynamic MRA.Methods: The attenuation of ASL blood signal due to the repetitive application of excitation RF pulses was minimized by splitting the acquisition volume into multiple thin 2D (M2D) slices, thereby reducing the exposure of the arterial blood magnetization to RF pulses while it flows within the brain. To improve the degraded vessel visualization in the slice direction due to the limited minimum achievable 2D slice thickness, a super‐resolution (SR) convolutional neural network (CNN) was trained by using 3D time‐of‐flight (TOF)‐MRA images from a large public dataset. And then, we applied domain transfer from 3D TOF‐MRA to M2D ASL‐MRA, while avoiding acquiring a large number of ASL‐MRA data required for CNN training.Results: Compared to the conventional 3D ASL‐MRA, far more distal arteries were visualized with higher signal intensity by using M2D ASL‐MRA. In general, however, the vessel visualization with a conventional interpolation was prone to be blurry and unclear due to the limited spatial resolution in the slice direction, particularly in small vessels. Application of CNN‐based SR transferred from 3D TOF‐MRA to M2D ASL‐MRA successfully addressed such a limitation and achieved clearer visualization of small vessels than conventional interpolation.Conclusion: This study demonstrated that the proposed framework provides improved visualization of distal arteries in later dynamic phases, which will particularly benefit the application of this approach in patients with cerebrovascular disease who have slow blood flow.
- Open Access
- 27 September 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 205-220
Structured low‐rank reconstruction for navigator‐free water/fat separated multi‐shot diffusion‐weightedEPI
Purpose: Multi‐shot diffusion‐weighted EPI allows an increase in image resolution and reduced geometric distortions and can be combined with chemical‐shift encoding (Dixon) to separate water/fat signals. However, such approaches suffer from physiological motion‐induced shot‐to‐shot phase variations. In this work, a structured low‐rank‐based navigator‐free algorithm is proposed to address the challenge of simultaneously separating water/fat signals and correcting for physiological motion‐induced shot‐to‐shot phase variations in multi‐shot EPI‐based diffusion‐weighted MRI.Theory and Methods: We propose an iterative, model‐based reconstruction pipeline that applies structured low‐rank regularization to estimate and eliminate the shot‐to‐shot phase variations in a data‐driven way, while separating water/fat images. The algorithm is tested in different anatomies, including head–neck, knee, brain, and prostate. The performance is validated in simulations and in‐vivo experiments in comparison to existing approaches.Results: In‐vivo experiments and simulations demonstrated the effectiveness of the proposed algorithm compared to extra‐navigated and an alternative self‐navigation approach. The proposed algorithm demonstrates the capability to reconstruct in the multi‐shot/Dixon hybrid space domain under‐sampled datasets, using the same number of acquired EPI shots compared to conventional fat‐suppression techniques but eliminating fat signals through chemical‐shift encoding. In addition, partial Fourier reconstruction can also be achieved by using the concept of virtual conjugate coils in conjunction with the proposed algorithm.Conclusion: The proposed algorithm effectively eliminates the shot‐to‐shot phase variations and separates water/fat images, making it a promising solution for future DWI on different anatomies.
- 27 September 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 205-220
Open AccessStructured low‐rank reconstruction for navigator‐free water/fat separated multi‐shot diffusion‐weightedEPI
Purpose: Multi‐shot diffusion‐weighted EPI allows an increase in image resolution and reduced geometric distortions and can be combined with chemical‐shift encoding (Dixon) to separate water/fat signals. However, such approaches suffer from physiological motion‐induced shot‐to‐shot phase variations. In this work, a structured low‐rank‐based navigator‐free algorithm is proposed to address the challenge of simultaneously separating water/fat signals and correcting for physiological motion‐induced shot‐to‐shot phase variations in multi‐shot EPI‐based diffusion‐weighted MRI.Theory and Methods: We propose an iterative, model‐based reconstruction pipeline that applies structured low‐rank regularization to estimate and eliminate the shot‐to‐shot phase variations in a data‐driven way, while separating water/fat images. The algorithm is tested in different anatomies, including head–neck, knee, brain, and prostate. The performance is validated in simulations and in‐vivo experiments in comparison to existing approaches.Results: In‐vivo experiments and simulations demonstrated the effectiveness of the proposed algorithm compared to extra‐navigated and an alternative self‐navigation approach. The proposed algorithm demonstrates the capability to reconstruct in the multi‐shot/Dixon hybrid space domain under‐sampled datasets, using the same number of acquired EPI shots compared to conventional fat‐suppression techniques but eliminating fat signals through chemical‐shift encoding. In addition, partial Fourier reconstruction can also be achieved by using the concept of virtual conjugate coils in conjunction with the proposed algorithm.Conclusion: The proposed algorithm effectively eliminates the shot‐to‐shot phase variations and separates water/fat images, making it a promising solution for future DWI on different anatomies.
- Open Access
- 15 June 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1484-1501
Sampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high‐resolution 3D diffusion MRI
Purpose: To develop a new method for high‐fidelity, high‐resolution 3D multi‐slab diffusion MRI with minimal distortion and boundary slice aliasing.Methods: Our method modifies 3D multi‐slab imaging to integrate blip‐reversed acquisitions for distortion correction and oversampling in the slice direction (kz) for reducing boundary slice aliasing. Our aim is to achieve robust acceleration to keep the scan time the same as conventional 3D multi‐slab acquisitions, in which data are acquired with a single direction of blip traversal and without kz‐oversampling. We employ a two‐stage reconstruction. In the first stage, the blip‐up/down images are respectively reconstructed and analyzed to produce a field map for each diffusion direction. In the second stage, the blip‐reversed data and the field map are incorporated into a joint reconstruction to produce images that are corrected for distortion and boundary slice aliasing.Results: We conducted experiments at 7T in six healthy subjects. Stage 1 reconstruction produces images from highly under‐sampled data (R = 7.2) with sufficient quality to provide accurate field map estimation. Stage 2 joint reconstruction substantially reduces distortion artifacts with comparable quality to fully‐sampled blip‐reversed results (2.4× scan time). Whole‐brain in‐vivo results acquired at 1.22 mm and 1.05 mm isotropic resolutions demonstrate improved anatomical fidelity compared to conventional 3D multi‐slab imaging. Data demonstrate good reliability and reproducibility of the proposed method over multiple subjects.Conclusion: The proposed acquisition and reconstruction framework provide major reductions in distortion and boundary slice aliasing for 3D multi‐slab diffusion MRI without increasing the scan time, which can potentially produce high‐quality, high‐resolution diffusion MRI.
- 15 June 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1484-1501
Open AccessSampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high‐resolution 3D diffusion MRI
Purpose: To develop a new method for high‐fidelity, high‐resolution 3D multi‐slab diffusion MRI with minimal distortion and boundary slice aliasing.Methods: Our method modifies 3D multi‐slab imaging to integrate blip‐reversed acquisitions for distortion correction and oversampling in the slice direction (kz) for reducing boundary slice aliasing. Our aim is to achieve robust acceleration to keep the scan time the same as conventional 3D multi‐slab acquisitions, in which data are acquired with a single direction of blip traversal and without kz‐oversampling. We employ a two‐stage reconstruction. In the first stage, the blip‐up/down images are respectively reconstructed and analyzed to produce a field map for each diffusion direction. In the second stage, the blip‐reversed data and the field map are incorporated into a joint reconstruction to produce images that are corrected for distortion and boundary slice aliasing.Results: We conducted experiments at 7T in six healthy subjects. Stage 1 reconstruction produces images from highly under‐sampled data (R = 7.2) with sufficient quality to provide accurate field map estimation. Stage 2 joint reconstruction substantially reduces distortion artifacts with comparable quality to fully‐sampled blip‐reversed results (2.4× scan time). Whole‐brain in‐vivo results acquired at 1.22 mm and 1.05 mm isotropic resolutions demonstrate improved anatomical fidelity compared to conventional 3D multi‐slab imaging. Data demonstrate good reliability and reproducibility of the proposed method over multiple subjects.Conclusion: The proposed acquisition and reconstruction framework provide major reductions in distortion and boundary slice aliasing for 3D multi‐slab diffusion MRI without increasing the scan time, which can potentially produce high‐quality, high‐resolution diffusion MRI.
- Open Access
- 19 January 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 86, 102744
Diffusion MRI data analysis assisted by deep learning synthesized anatomical images (DeepAnat)
- 19 January 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 86, 102744
Open AccessDiffusion MRI data analysis assisted by deep learning synthesized anatomical images (DeepAnat)
- Open Access
Sampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high-resolution 3D diffusion MRI
Purpose: To develop a new method for high-fidelity, high-resolution 3D multi-slab diffusion MRI with minimal distortion and boundary slice aliasing. Methods: Our method modifies 3D multi-slab imaging to integrate blip-reversed acquisitions for distortion correction and oversampling in the slice direction (kz) for reducing boundary slice aliasing. Our aim is to achieve robust acceleration to keep the scan time the same as conventional 3D multi-slab acquisitions, in which data are acquired with a single direction of blip traversal and without kz-oversampling. We employ a two-stage reconstruction. In the first stage, the blip-up/down images are respectively reconstructed and analyzed to produce a field map for each diffusion direction. In the second stage, the blip-reversed data and the field map are incorporated into a joint reconstruction to produce images that are corrected for distortion and boundary slice aliasing. Results: We conducted experiments at 7T in six healthy subjects. Stage 1 reconstruction produces images from highly under-sampled data (R=7.2) with sufficient quality to provide accurate field map estimation. Stage 2 joint reconstruction substantially reduces distortion artifacts with comparable quality to fully-sampled blip-reversed results (2.4× scan time). Whole-brain in-vivo results acquired at 1.05mm isotropic resolution demonstrate improved anatomical fidelity compared to conventional 3D multi-slab imaging. Data demonstrate good reliability and reproducibility of the proposed method over multiple subjects. Conclusion: The proposed acquisition and reconstruction framework provide major reductions in distortion and boundary slice aliasing for 3D multi-slab diffusion MRI without increasing the scan time. This method has the potential to provide high-quality, high-resolution diffusion MRI.
Open AccessSampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high-resolution 3D diffusion MRI
Purpose: To develop a new method for high-fidelity, high-resolution 3D multi-slab diffusion MRI with minimal distortion and boundary slice aliasing. Methods: Our method modifies 3D multi-slab imaging to integrate blip-reversed acquisitions for distortion correction and oversampling in the slice direction (kz) for reducing boundary slice aliasing. Our aim is to achieve robust acceleration to keep the scan time the same as conventional 3D multi-slab acquisitions, in which data are acquired with a single direction of blip traversal and without kz-oversampling. We employ a two-stage reconstruction. In the first stage, the blip-up/down images are respectively reconstructed and analyzed to produce a field map for each diffusion direction. In the second stage, the blip-reversed data and the field map are incorporated into a joint reconstruction to produce images that are corrected for distortion and boundary slice aliasing. Results: We conducted experiments at 7T in six healthy subjects. Stage 1 reconstruction produces images from highly under-sampled data (R=7.2) with sufficient quality to provide accurate field map estimation. Stage 2 joint reconstruction substantially reduces distortion artifacts with comparable quality to fully-sampled blip-reversed results (2.4× scan time). Whole-brain in-vivo results acquired at 1.05mm isotropic resolution demonstrate improved anatomical fidelity compared to conventional 3D multi-slab imaging. Data demonstrate good reliability and reproducibility of the proposed method over multiple subjects. Conclusion: The proposed acquisition and reconstruction framework provide major reductions in distortion and boundary slice aliasing for 3D multi-slab diffusion MRI without increasing the scan time. This method has the potential to provide high-quality, high-resolution diffusion MRI.