Wenchuan Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wenchuan Wu has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
Karla L. Miller
12 shared publications- Karla L. Miller
Oxford University Centre for Integrative Neuroimaging (OxCIN), FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford
7 shared publications - Mark Chiew
Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
6 shared publications - Thomas W. Okell
Oxford Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
6 shared publications - Ziyu Li
Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences University of Oxford Oxford UK
6 shared publications - Joseph Woods
Oxford Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences University of Oxford Oxford UK
5 shared publications
Latest Publications
- Open Access
- 19 September 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 115
CoilDrop-MRI: Self-supervised physics-guided MRI reconstruction with coil dropout
- 19 September 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 115
Open AccessCoilDrop-MRI: Self-supervised physics-guided MRI reconstruction with coil dropout
- Open Access
10.5 Tesla High-Resolution Macaque Brain MRI for Connectivity Studies
Mapping brain connectivity in primates remains a major challenge due to difficulties in resolving microscopic white matter architecture, while maintaining whole-brain coverage. Increasing imaging spatial resolution is key for disambiguating fiber configurations within smaller anatomical volumes. Here, we present developments that allow high-resolution diffusion MRI of the macaque brain, both in vivo and ex vivo, using one of the world’s highest-field human MRI scanners operating at 10.5 Tesla. Our approach achieves data of highest reported resolutions for this field strength and scanner type, (750 μm ) 3 in vivo and (400 μm ) 3 ex vivo , with diffusion weighting up to b = 6000 s/mm 2 . We detail methodological advances in data acquisition, image reconstruction, processing and whole-brain tractography that overcome critical challenges associated with ultra-high-field imaging. This work establishes a new benchmark for high-resolution neuroimaging at 10.5T, paving the way for comparable human studies and enabling analyses of brain connectivity across species and tissue states at unprecedented detail. The dataset, along with all processing pipelines, containerised workflows, and reusable web services, is openly shared to support reproducibility and future integration with microscopy for studying white matter microstructure and connections at the mesoscale.
Open Access10.5 Tesla High-Resolution Macaque Brain MRI for Connectivity Studies
Mapping brain connectivity in primates remains a major challenge due to difficulties in resolving microscopic white matter architecture, while maintaining whole-brain coverage. Increasing imaging spatial resolution is key for disambiguating fiber configurations within smaller anatomical volumes. Here, we present developments that allow high-resolution diffusion MRI of the macaque brain, both in vivo and ex vivo, using one of the world’s highest-field human MRI scanners operating at 10.5 Tesla. Our approach achieves data of highest reported resolutions for this field strength and scanner type, (750 μm ) 3 in vivo and (400 μm ) 3 ex vivo , with diffusion weighting up to b = 6000 s/mm 2 . We detail methodological advances in data acquisition, image reconstruction, processing and whole-brain tractography that overcome critical challenges associated with ultra-high-field imaging. This work establishes a new benchmark for high-resolution neuroimaging at 10.5T, paving the way for comparable human studies and enabling analyses of brain connectivity across species and tissue states at unprecedented detail. The dataset, along with all processing pipelines, containerised workflows, and reusable web services, is openly shared to support reproducibility and future integration with microscopy for studying white matter microstructure and connections at the mesoscale.
- Open Access
Diffusion-weighted steady-state free precession imaging in the ex vivo macaque brain on a 10.5T human MRI scanner
Diffusion MRI provides a non-invasive probe of local fibre bundles and long-range anatomical connections to characterise the structural connectome. One way to achieve very high spatial resolution diffusion MRI data for connectivity investigations is to scan ex-vivo brains over many hours or days, ideally at ultra-high field strength to boost signal levels. However, conventional diffusion MRI acquisition techniques do not generally deliver good data quality for the challenging conditions of ex-vivo tissue, characterised by reduced diffusivities and relaxation times when compared to in vivo. In this work, we investigate the potential of the diffusion-weighted steady-state free precession (DW-SSFP) sequence for ex vivo diffusion imaging of the macaque brain using a 10.5 T human MRI scanner with a conventional (G_max=70 mT/m) gradient set. SNR-efficiency optimisations incorporating experimental relaxation times demonstrate that the DW-SSFP sequence is predicted to achieve improved or similar SNR efficiency compared to a diffusion-weighted spin- and stimulated-echo sequence. Importantly, DW-SSFP can achieve this with the additional benefit of negligible geometric distortions, unlike conventional diffusion MRI using an echo-planar imaging readout. Using optimised DW-SSFP sequence parameters, we propose a protocol at 0.4 mm isotropic resolution using a two-shell multi-orientation protocol (effective b-values of 3200 s/mm^2 and 5600 s/mm^2). We fit the data using Tensor, Ball and 3-Sticks and Constrained Spherical Deconvolution signal representations. The results demonstrate high-quality diffusivity estimates across the entire brain with the ability to resolve multiple fibre populations in challenging crossing-fibre regions. The data will be made fully open source and multimodal as part of the Center for Mesoscale Connectomics, providing a resource for future connectivity investigations.
Open AccessDiffusion-weighted steady-state free precession imaging in the ex vivo macaque brain on a 10.5T human MRI scanner
Diffusion MRI provides a non-invasive probe of local fibre bundles and long-range anatomical connections to characterise the structural connectome. One way to achieve very high spatial resolution diffusion MRI data for connectivity investigations is to scan ex-vivo brains over many hours or days, ideally at ultra-high field strength to boost signal levels. However, conventional diffusion MRI acquisition techniques do not generally deliver good data quality for the challenging conditions of ex-vivo tissue, characterised by reduced diffusivities and relaxation times when compared to in vivo. In this work, we investigate the potential of the diffusion-weighted steady-state free precession (DW-SSFP) sequence for ex vivo diffusion imaging of the macaque brain using a 10.5 T human MRI scanner with a conventional (G_max=70 mT/m) gradient set. SNR-efficiency optimisations incorporating experimental relaxation times demonstrate that the DW-SSFP sequence is predicted to achieve improved or similar SNR efficiency compared to a diffusion-weighted spin- and stimulated-echo sequence. Importantly, DW-SSFP can achieve this with the additional benefit of negligible geometric distortions, unlike conventional diffusion MRI using an echo-planar imaging readout. Using optimised DW-SSFP sequence parameters, we propose a protocol at 0.4 mm isotropic resolution using a two-shell multi-orientation protocol (effective b-values of 3200 s/mm^2 and 5600 s/mm^2). We fit the data using Tensor, Ball and 3-Sticks and Constrained Spherical Deconvolution signal representations. The results demonstrate high-quality diffusivity estimates across the entire brain with the ability to resolve multiple fibre populations in challenging crossing-fibre regions. The data will be made fully open source and multimodal as part of the Center for Mesoscale Connectomics, providing a resource for future connectivity investigations.
- Open Access
An RF coil array system for in vivo & ex vivo non-human primate brain studies at 10.5 Tesla
Purpose: We aimed to develop an innovative RF coil toolset for high resolution in vivo and ex vivo non-human primate neuroimaging applications at 10.5T MRI. The main goal was to improve our multimodal neural connectivity pipeline through the improved SNR, CNR, and spatial resolution that result from utilizing high-density RF coil arrays in combination with ultra-high field MRI. Methods: Two RF coil arrays, both comprising 8 transmit and 40 receive channels, were designed and built for in vivo and ex vivo NHP imaging at 10.5 T. Experimental data was collected on multiple in vivo and ex vivo specimens, showing the utility UHF MRI for NHP neuroscience. Results: Experimental results demonstrate uniform whole-brain coverage within both in vivo—which included the cerebellar, and spinal cord regions—and ex vivo specimens. High spatial resolutions (in vivo: 0.1×0.1×0.5 mm, ex vivo: 120 micron isotropic ) were achieved, revealing detailed anatomical structures throughout. High temporal stability allowed for EPI and dMRI applications. Conclusion: An RF coil toolset comprising two 8ch transmit/40ch receive arrays was successfully designed for both in vivo and ex vivo NHP brain applications at 10.5 T. Both high-density RF coil arrays coupled with the SNR and CNR benefits available at UHF supported unmatched anatomical, functional, and diffusion applications at some of the highest spatial resolutions to date. Additionally, the combined capability of both in vivo and ex vivo MRI with the same brain specimen allows for tighter control for experimental-paradigm multistage studies examining translation between in vivo and ex vivo methodologies.
Open AccessAn RF coil array system for in vivo & ex vivo non-human primate brain studies at 10.5 Tesla
Purpose: We aimed to develop an innovative RF coil toolset for high resolution in vivo and ex vivo non-human primate neuroimaging applications at 10.5T MRI. The main goal was to improve our multimodal neural connectivity pipeline through the improved SNR, CNR, and spatial resolution that result from utilizing high-density RF coil arrays in combination with ultra-high field MRI. Methods: Two RF coil arrays, both comprising 8 transmit and 40 receive channels, were designed and built for in vivo and ex vivo NHP imaging at 10.5 T. Experimental data was collected on multiple in vivo and ex vivo specimens, showing the utility UHF MRI for NHP neuroscience. Results: Experimental results demonstrate uniform whole-brain coverage within both in vivo—which included the cerebellar, and spinal cord regions—and ex vivo specimens. High spatial resolutions (in vivo: 0.1×0.1×0.5 mm, ex vivo: 120 micron isotropic ) were achieved, revealing detailed anatomical structures throughout. High temporal stability allowed for EPI and dMRI applications. Conclusion: An RF coil toolset comprising two 8ch transmit/40ch receive arrays was successfully designed for both in vivo and ex vivo NHP brain applications at 10.5 T. Both high-density RF coil arrays coupled with the SNR and CNR benefits available at UHF supported unmatched anatomical, functional, and diffusion applications at some of the highest spatial resolutions to date. Additionally, the combined capability of both in vivo and ex vivo MRI with the same brain specimen allows for tighter control for experimental-paradigm multistage studies examining translation between in vivo and ex vivo methodologies.
- Open Access
- 10 October 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 107
Submillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction
- 10 October 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 107
Open AccessSubmillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction
- Open Access
Modelling motion-induced signal corruption in steady-state diffusion MRI
Purpose: Diffusion-weighted steady-state free precession (DW-SSFP) is a diffusion imaging sequence achieving high SNR efficiency. A key challenge for in vivo DW-SSFP is the sequence’s severe motion sensitivity, currently limiting investigations to low or no motion regimes. Here we establish a framework to both (1) model and (2) correct for the impact of subject motion associated with the underlying magnetisation distribution of DW-SSFP. Theory and Methods: An extended phase graphs (EPG) representation of the 1D DW-SSFP signal was established incorporating a motion operator describing rigid body and pulsatile motion. The representation was validated using Monte Carlo simulations, and subsequently integrated into a data fitting routine for motion estimation and correction. The fitting routine was evaluated using both simulations and a voxelwise correction applied to in vivo experimental 2D low-resolution single-shot timeseries DW-SSFP data acquired in the human brain in three healthy volunteers, with a tensor reconstructed from the motion-corrected experimental DW-SSFP data. Results: The proposed EPG-motion framework gives excellent agreement to complementary Monte Carlo simulations, demonstrating that diffusion coefficient estimation is robust over a range of motion and SNR regimes. Tensor estimates from the motion-corrected experimental DW-SSFP data give good visual agreement to complementary diffusion-weighted spin-echo (DW-SE) data acquired in the same subject, considerably reducing orientation-dependent motion-induced biases. Conclusion: Temporal information capturing the evolution of the DW-SSFP signal can be used to retrospectively (1) estimate subject motion and (2) reconstruct motion-corrected DW-SSFP data. Open-source software is provided, facilitating future investigations into the impact of subject-motion on DW-SSFP acquisitions.
Open AccessModelling motion-induced signal corruption in steady-state diffusion MRI
Purpose: Diffusion-weighted steady-state free precession (DW-SSFP) is a diffusion imaging sequence achieving high SNR efficiency. A key challenge for in vivo DW-SSFP is the sequence’s severe motion sensitivity, currently limiting investigations to low or no motion regimes. Here we establish a framework to both (1) model and (2) correct for the impact of subject motion associated with the underlying magnetisation distribution of DW-SSFP. Theory and Methods: An extended phase graphs (EPG) representation of the 1D DW-SSFP signal was established incorporating a motion operator describing rigid body and pulsatile motion. The representation was validated using Monte Carlo simulations, and subsequently integrated into a data fitting routine for motion estimation and correction. The fitting routine was evaluated using both simulations and a voxelwise correction applied to in vivo experimental 2D low-resolution single-shot timeseries DW-SSFP data acquired in the human brain in three healthy volunteers, with a tensor reconstructed from the motion-corrected experimental DW-SSFP data. Results: The proposed EPG-motion framework gives excellent agreement to complementary Monte Carlo simulations, demonstrating that diffusion coefficient estimation is robust over a range of motion and SNR regimes. Tensor estimates from the motion-corrected experimental DW-SSFP data give good visual agreement to complementary diffusion-weighted spin-echo (DW-SE) data acquired in the same subject, considerably reducing orientation-dependent motion-induced biases. Conclusion: Temporal information capturing the evolution of the DW-SSFP signal can be used to retrospectively (1) estimate subject motion and (2) reconstruct motion-corrected DW-SSFP data. Open-source software is provided, facilitating future investigations into the impact of subject-motion on DW-SSFP acquisitions.
- Open Access
- 6 April 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (2) , 694-712
Accelerated multi‐shell diffusion MRI with Gaussian process estimated reconstruction of multi‐band imaging
Purpose: This work aims to propose a robust reconstruction method exploiting shared information across shells to increase the acquisition speed of multi‐shell diffusion‐weighted MRI (dMRI), enabling rapid tissue microstructure mapping. Theory and Methods: Local q‐space points share similar information. Gaussian Process can exploit the q‐space smoothness in a data‐driven way and provide q‐space signal estimation based on the signals from a q‐space neighborhood. The Diffusion Acceleration with Gaussian process Estimated Reconstruction (DAGER) method uses the signal estimation from Gaussian process as a prior in a joint k‐q reconstruction and improves image quality under high acceleration factors compared to conventional (k‐only) reconstruction. In this work, we extend the DAGER method by introducing a multi‐shell covariance function and correcting for Rician noise distribution in magnitude data when fitting the Gaussian process model. The method was evaluated with both simulation and in vivo data. Results: Simulated and in‐vivo results demonstrate that the proposed method can significantly improve the image quality of reconstructed dMRI data with high acceleration both in‐plane and slice‐wise, achieving a total acceleration factor of 12. The improvement of image quality allows more robust diffusion model fitting compared to conventional reconstruction methods, enabling advanced multi‐shell diffusion analysis within much shorter scan time. Conclusion: The proposed method enables highly accelerated dMRI which can shorten the scan time of multi‐shell dMRI without sacrificing quality compared to conventional practice. This may facilitate a wider application of advanced dMRI models in basic and clinical neuroscience.
- 6 April 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (2) , 694-712
Open AccessAccelerated multi‐shell diffusion MRI with Gaussian process estimated reconstruction of multi‐band imaging
Purpose: This work aims to propose a robust reconstruction method exploiting shared information across shells to increase the acquisition speed of multi‐shell diffusion‐weighted MRI (dMRI), enabling rapid tissue microstructure mapping. Theory and Methods: Local q‐space points share similar information. Gaussian Process can exploit the q‐space smoothness in a data‐driven way and provide q‐space signal estimation based on the signals from a q‐space neighborhood. The Diffusion Acceleration with Gaussian process Estimated Reconstruction (DAGER) method uses the signal estimation from Gaussian process as a prior in a joint k‐q reconstruction and improves image quality under high acceleration factors compared to conventional (k‐only) reconstruction. In this work, we extend the DAGER method by introducing a multi‐shell covariance function and correcting for Rician noise distribution in magnitude data when fitting the Gaussian process model. The method was evaluated with both simulation and in vivo data. Results: Simulated and in‐vivo results demonstrate that the proposed method can significantly improve the image quality of reconstructed dMRI data with high acceleration both in‐plane and slice‐wise, achieving a total acceleration factor of 12. The improvement of image quality allows more robust diffusion model fitting compared to conventional reconstruction methods, enabling advanced multi‐shell diffusion analysis within much shorter scan time. Conclusion: The proposed method enables highly accelerated dMRI which can shorten the scan time of multi‐shell dMRI without sacrificing quality compared to conventional practice. This may facilitate a wider application of advanced dMRI models in basic and clinical neuroscience.
- Open Access
- 29 December 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (5) , 1924-1941
Ultra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction
Purpose: To achieve ultra‐high temporal resolution non‐contrast 4D angiography with improved spatiotemporal fidelity.Methods: Continuous data acquisition using 3D golden‐angle sampling following an arterial spin labeling preparation allows for flexibly reconstructing 4D dynamic angiograms at arbitrary temporal resolutions. However, k‐space data is often temporally “binned” before image reconstruction, negatively affecting spatiotemporal fidelity and limiting temporal resolution. In this work, a subspace was extracted by linearly compressing a dictionary constructed from simulated curves of an angiographic kinetic model. The subspace was used to represent and reconstruct the voxelwise signal timecourse at the same temporal resolution as the data acquisition without temporal binning. Physiological parameters were estimated from the resulting images using a Bayesian fitting approach. A group of eight healthy subjects were scanned and the in vivo results reconstructed by different methods were compared. Because of the difficulty of obtaining ground truth 4D angiograms with ultra‐high temporal resolution, the in vivo results were cross‐validated with numerical simulations.Results: The proposed method enables 4D time‐resolved angiography with much higher temporal resolution (14.7 ms) than previously reported (˜50 ms) while maintaining high spatial resolution (1.1 mm isotropic). Blood flow dynamics were depicted in greater detail, thin vessel visibility was improved, and the estimated physiological parameters also exhibited more realistic spatial patterns with the proposed method.Conclusion: Incorporating a subspace compressed kinetic model into the reconstruction of 4D ASL angiograms notably improved the temporal resolution and spatiotemporal fidelity, which was subsequently beneficial for accurate physiological modeling.
- 29 December 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (5) , 1924-1941
Open AccessUltra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction
Purpose: To achieve ultra‐high temporal resolution non‐contrast 4D angiography with improved spatiotemporal fidelity.Methods: Continuous data acquisition using 3D golden‐angle sampling following an arterial spin labeling preparation allows for flexibly reconstructing 4D dynamic angiograms at arbitrary temporal resolutions. However, k‐space data is often temporally “binned” before image reconstruction, negatively affecting spatiotemporal fidelity and limiting temporal resolution. In this work, a subspace was extracted by linearly compressing a dictionary constructed from simulated curves of an angiographic kinetic model. The subspace was used to represent and reconstruct the voxelwise signal timecourse at the same temporal resolution as the data acquisition without temporal binning. Physiological parameters were estimated from the resulting images using a Bayesian fitting approach. A group of eight healthy subjects were scanned and the in vivo results reconstructed by different methods were compared. Because of the difficulty of obtaining ground truth 4D angiograms with ultra‐high temporal resolution, the in vivo results were cross‐validated with numerical simulations.Results: The proposed method enables 4D time‐resolved angiography with much higher temporal resolution (14.7 ms) than previously reported (˜50 ms) while maintaining high spatial resolution (1.1 mm isotropic). Blood flow dynamics were depicted in greater detail, thin vessel visibility was improved, and the estimated physiological parameters also exhibited more realistic spatial patterns with the proposed method.Conclusion: Incorporating a subspace compressed kinetic model into the reconstruction of 4D ASL angiograms notably improved the temporal resolution and spatiotemporal fidelity, which was subsequently beneficial for accurate physiological modeling.
- Open Access
Accelerated multi-shell diffusion MRI with Gaussian process estimated reconstruction of multi-band imaging
Purpose This work aims to propose a robust reconstruction method exploiting shared information across shells to increase the acquisition speed of multi-shell diffusion MRI, enabling rapid tissue microstructure mapping. Theory and Methods Local q-space points share similar information. Gaussian Process can exploit the q-space smoothness in a data-driven way and provide q-space signal estimation based on the signals from a q-space neighborhood. The Diffusion Acceleration with Gaussian process Estimated Reconstruction (DAGER) method uses the signal estimation from Gaussian process as a prior in a joint k-q reconstruction and improves image quality under high acceleration factors compared to conventional (k-only) reconstruction. In this work, we extend the DAGER method by introducing a multi-shell covariance function and correcting for Rician noise distribution in magnitude data when fitting the Gaussian process model. The method was evaluated with both simulation and in vivo data. Results Simulated and in-vivo results demonstrate that the proposed method can significantly improve the image quality of reconstructed dMRI data with high acceleration both in-plane and slice-wise, achieving a total acceleration factor of 12. The improvement of image quality allows more robust diffusion model fitting compared to conventional reconstruction methods, enabling advanced multi-shell diffusion analysis within much shorter scan time. Conclusion The proposed method enables highly accelerated dMRI which can shorten the scan time of multi-shell dMRI without sacrificing quality compared to conventional practice. This may facilitate a wider application of advanced dMRI models in basic and clinical neuroscience.
Open AccessAccelerated multi-shell diffusion MRI with Gaussian process estimated reconstruction of multi-band imaging
Purpose This work aims to propose a robust reconstruction method exploiting shared information across shells to increase the acquisition speed of multi-shell diffusion MRI, enabling rapid tissue microstructure mapping. Theory and Methods Local q-space points share similar information. Gaussian Process can exploit the q-space smoothness in a data-driven way and provide q-space signal estimation based on the signals from a q-space neighborhood. The Diffusion Acceleration with Gaussian process Estimated Reconstruction (DAGER) method uses the signal estimation from Gaussian process as a prior in a joint k-q reconstruction and improves image quality under high acceleration factors compared to conventional (k-only) reconstruction. In this work, we extend the DAGER method by introducing a multi-shell covariance function and correcting for Rician noise distribution in magnitude data when fitting the Gaussian process model. The method was evaluated with both simulation and in vivo data. Results Simulated and in-vivo results demonstrate that the proposed method can significantly improve the image quality of reconstructed dMRI data with high acceleration both in-plane and slice-wise, achieving a total acceleration factor of 12. The improvement of image quality allows more robust diffusion model fitting compared to conventional reconstruction methods, enabling advanced multi-shell diffusion analysis within much shorter scan time. Conclusion The proposed method enables highly accelerated dMRI which can shorten the scan time of multi-shell dMRI without sacrificing quality compared to conventional practice. This may facilitate a wider application of advanced dMRI models in basic and clinical neuroscience.
- Open Access
Submillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction
High-resolution diffusion MRI (dMRI) provides valuable insights into brain microstructure, particularly at submillimeter resolutions, where it enables more precise delineations of curved and crossing white matter pathways. However, achieving high-quality submillimeter dMRI in-vivo poses significant challenges due to the intrinsically low signal-to-noise ratio (SNR), along with the long echo spacing, readout time, and TE required for the large matrix size, leading to significant image distortion, T2* blurring, and T2 signal decay. In this study, we propose a novel acquisition and reconstruction framework to overcome these challenges. Based on numerical simulations, we introduce an in-plane segmented 3D multi-slab acquisition that leverages the optimal SNR efficiency of 3D multi-slab imaging while reducing echo spacing, readout times, and TE using in-plane segmentation. This approach minimizes distortion, improves image sharpness, and enhances SNR. Additionally, we develop a denoiser-regularized reconstruction to suppress noise while maintaining data fidelity, which reconstructs high-SNR images without introducing substantial blurring or bias. Comprehensive in-vivo experiments demonstrate that our method consistently produces high-quality dMRI data at 0.65 mm and 0.53 mm isotropic resolutions on a 3T scanner. The submillimeter dMRI datasets reveal richer microstructural details, reduce gyral bias, and improve U-fiber mapping compared to prospectively acquired 1.22 mm diffusion data. Our method demonstrates robustness at 7T and generates high-SNR 0.61 mm diffusion datasets, showing excellent agreement with previous post-mortem studies at the same scanner. Implemented using the open-source, scanner-agnostic framework Pulseq, our approach may facilitate broader adoption across different scanner platforms to benefit a wider range of applications. These results underscore the potential of our method to advance medical image analysis and neuroscientific research on human brain connectivity.
Open AccessSubmillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction
High-resolution diffusion MRI (dMRI) provides valuable insights into brain microstructure, particularly at submillimeter resolutions, where it enables more precise delineations of curved and crossing white matter pathways. However, achieving high-quality submillimeter dMRI in-vivo poses significant challenges due to the intrinsically low signal-to-noise ratio (SNR), along with the long echo spacing, readout time, and TE required for the large matrix size, leading to significant image distortion, T2* blurring, and T2 signal decay. In this study, we propose a novel acquisition and reconstruction framework to overcome these challenges. Based on numerical simulations, we introduce an in-plane segmented 3D multi-slab acquisition that leverages the optimal SNR efficiency of 3D multi-slab imaging while reducing echo spacing, readout times, and TE using in-plane segmentation. This approach minimizes distortion, improves image sharpness, and enhances SNR. Additionally, we develop a denoiser-regularized reconstruction to suppress noise while maintaining data fidelity, which reconstructs high-SNR images without introducing substantial blurring or bias. Comprehensive in-vivo experiments demonstrate that our method consistently produces high-quality dMRI data at 0.65 mm and 0.53 mm isotropic resolutions on a 3T scanner. The submillimeter dMRI datasets reveal richer microstructural details, reduce gyral bias, and improve U-fiber mapping compared to prospectively acquired 1.22 mm diffusion data. Our method demonstrates robustness at 7T and generates high-SNR 0.61 mm diffusion datasets, showing excellent agreement with previous post-mortem studies at the same scanner. Implemented using the open-source, scanner-agnostic framework Pulseq, our approach may facilitate broader adoption across different scanner platforms to benefit a wider range of applications. These results underscore the potential of our method to advance medical image analysis and neuroscientific research on human brain connectivity.