Davut Özkan
Research Subjects
Research Interests
Davut Özkan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bike Altan
Department of Prosthodontics, Faculty of Dentistry, University of Health Sciences, Istanbul, Türkiye
3 shared publications - Sevki Cinar
SAĞLIK BİLİMLERİ ÜNİVERSİTESİ, HAMİDİYE DİŞ HEKİMLİĞİ FAKÜLTESİ, HAMİDİYE DİŞ HEKİMLİĞİ PR
3 shared publications - Mehmet Ali Fildisi
Department of Restorative Dentistry, Faculty of Dentistry, University of Health Sciences, Istanbul 34668, Turkey
2 shared publications - Beste Burcu Uz
SAĞLIK BİLİMLERİ ÜNİVERSİTESİ, HAMİDİYE DİŞ HEKİMLİĞİ FAKÜLTESİ, HAMİDİYE DİŞ HEKİMLİĞİ PR
1 shared publication - Elifnur Aydemir Aydin
Restorative Dentistry Department, Faculty of Dentistry, İstanbul Medipol University, TEM Avrupa Otoyolu Goztepe Cikisi No:1, 34214, Bagcilar, Istanbul, Turkey
1 shared publication
Latest Publications
- Open Access
- 27 March 2023
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 6 (2) , 307-314
Current treatment approaches of newly graduated, intern dentists and dentists in doctoral and specialty training to teeth with excessive substance loss (cross-sectional study)
Aim: New treatment options have been developed as alternative post-retaining restorations and crowns that preserve remaining tooth tissue in endodontically treated teeth with excessive substance loss. This study, current treatment approaches newly graduated, intern and doctoral or specialist dentists in teeth excessive coronal destruction were evaluated. Material and Method: This cross-sectional study, online questionnaire consisting of 22 questions, 3 parts was applied. First part consists of demographic information participants, second part consists of questions measuring awareness about preferred indirect restorations, last part consists of current treatment approaches newly graduated, intern and doctoral or specialist dentists. Total 234 voluntary participants questionnaires were evaluated. Obtained data were analyzed with IBM SPSS V23. Results: In restoration of endodontically treated buccal mesial walls (least 2 mm thick) molars, participants all 3 groups preferred posterior adhesive indirect restorations according to their titles. Considering level of awareness, participants high group preferred posterior adhesive indirect restorations more in restorations endodontically treated buccal lingual walled molar teeth. Participants all 3 groups preferred use fiber under composite strengthen teeth in the restoration of teeth with excessive substance loss. Conclusion: According to the results, it was determined that awareness and knowledge level of dentists who received specialty or doctoral training about new current treatments was higher than other newly graduated and intern dentists. It was observed that participants group with high level awareness mostly preferred posterior region indirect adhesive restorations such as endocrown and onlay.
- 27 March 2023
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 6 (2) , 307-314
Open AccessCurrent treatment approaches of newly graduated, intern dentists and dentists in doctoral and specialty training to teeth with excessive substance loss (cross-sectional study)
Aim: New treatment options have been developed as alternative post-retaining restorations and crowns that preserve remaining tooth tissue in endodontically treated teeth with excessive substance loss. This study, current treatment approaches newly graduated, intern and doctoral or specialist dentists in teeth excessive coronal destruction were evaluated. Material and Method: This cross-sectional study, online questionnaire consisting of 22 questions, 3 parts was applied. First part consists of demographic information participants, second part consists of questions measuring awareness about preferred indirect restorations, last part consists of current treatment approaches newly graduated, intern and doctoral or specialist dentists. Total 234 voluntary participants questionnaires were evaluated. Obtained data were analyzed with IBM SPSS V23. Results: In restoration of endodontically treated buccal mesial walls (least 2 mm thick) molars, participants all 3 groups preferred posterior adhesive indirect restorations according to their titles. Considering level of awareness, participants high group preferred posterior adhesive indirect restorations more in restorations endodontically treated buccal lingual walled molar teeth. Participants all 3 groups preferred use fiber under composite strengthen teeth in the restoration of teeth with excessive substance loss. Conclusion: According to the results, it was determined that awareness and knowledge level of dentists who received specialty or doctoral training about new current treatments was higher than other newly graduated and intern dentists. It was observed that participants group with high level awareness mostly preferred posterior region indirect adhesive restorations such as endocrown and onlay.
- Open Access
- 20 January 2023
- Published by Wiley in BioMed Research International
- Vol. 2023 (1)
Effects of Two Different Acid Etching and Surface Washing Methods on Bond Strength on Different CAD‐CAM Blocks under Aging Protocols
Aim. The purpose of this study is to investigate the effects of hydrofluoric acid and one‐component ceramic primer and silane (Monobond Etch and Prime (MEP)) applications on lithium disilicate glass ceramics and zirconium‐infiltrated lithium silicate glass ceramics, as well as the effect of ultrasonic and phosphoric acid surface washing methods on bond strength. Materials and Method. A total of 240 ceramic samples were prepared using two different CAD‐CAM material blocks with a thickness of 2 mm made of lithium disilicate glass‐ceramic (IPS e.max CAD) and zirconium‐infiltrated lithium silicate glass ceramic blocks (Celtra Duo). The samples were cemented to the composite discs (Tetric N‐Ceram) after two different acid treatments, and surface washing processes were applied to them. As such, 24 groups were formed, each with two different acid applications, three different washing processes, two different CAD‐CAM blocks, and two different aging procedures (n = 10). Following the application of the acid, different washing processes are used. These were HF acid and washing only (HF + W), HF acid and ultrasonic washing (HF + US), HF acid and phosphoric acid (HF + PA), MEP with washing only (MEP + W), MEP and ultrasonic washing (MEP + US), and MEP and phosphoric acid (MEP + PA). The composite discs were cemented with dual cure adhesive cement (Multilink Automix) after the determined surface treatments were applied to the blocks. After surface applications, SEM analysis was conducted. Following exposure to two different thermal procedures, long‐term (TL) and short‐term (TS), bond strengths were measured using an Instron universal test device. SPSS version 23.0 software was used to perform the statistical analyses. Histogram graphs and the Kolmogorov‐Smirnov/Shapiro‐Wilk test were used to assess the variables’ conformity to the normal distribution. Results. The bond strength values of TS and TL in the Celtra Duo block were significantly higher than those in the e.max CAD block (p < 0.05). The TS‐TL bonding strength value difference in the e.max CAD block was significantly higher than the surface measurements in the Celtra Duo block. While the highest bond strength value HF + US for TS in e.max CAD was 20.07 ± .31, the values of HF + US in Celtra Duo were significantly higher in terms of TL values when compared to other groups. Conclusion. Celtra Duo material demonstrated higher bond strength values after a short and long thermal cycle than e.max CAD material. In general, groups bonded with HF were less affected by the thermal cycle than groups treated with MEP.
- 20 January 2023
- Published by Wiley in BioMed Research International
- Vol. 2023 (1)
Open AccessEffects of Two Different Acid Etching and Surface Washing Methods on Bond Strength on Different CAD‐CAM Blocks under Aging Protocols
Aim. The purpose of this study is to investigate the effects of hydrofluoric acid and one‐component ceramic primer and silane (Monobond Etch and Prime (MEP)) applications on lithium disilicate glass ceramics and zirconium‐infiltrated lithium silicate glass ceramics, as well as the effect of ultrasonic and phosphoric acid surface washing methods on bond strength. Materials and Method. A total of 240 ceramic samples were prepared using two different CAD‐CAM material blocks with a thickness of 2 mm made of lithium disilicate glass‐ceramic (IPS e.max CAD) and zirconium‐infiltrated lithium silicate glass ceramic blocks (Celtra Duo). The samples were cemented to the composite discs (Tetric N‐Ceram) after two different acid treatments, and surface washing processes were applied to them. As such, 24 groups were formed, each with two different acid applications, three different washing processes, two different CAD‐CAM blocks, and two different aging procedures (n = 10). Following the application of the acid, different washing processes are used. These were HF acid and washing only (HF + W), HF acid and ultrasonic washing (HF + US), HF acid and phosphoric acid (HF + PA), MEP with washing only (MEP + W), MEP and ultrasonic washing (MEP + US), and MEP and phosphoric acid (MEP + PA). The composite discs were cemented with dual cure adhesive cement (Multilink Automix) after the determined surface treatments were applied to the blocks. After surface applications, SEM analysis was conducted. Following exposure to two different thermal procedures, long‐term (TL) and short‐term (TS), bond strengths were measured using an Instron universal test device. SPSS version 23.0 software was used to perform the statistical analyses. Histogram graphs and the Kolmogorov‐Smirnov/Shapiro‐Wilk test were used to assess the variables’ conformity to the normal distribution. Results. The bond strength values of TS and TL in the Celtra Duo block were significantly higher than those in the e.max CAD block (p < 0.05). The TS‐TL bonding strength value difference in the e.max CAD block was significantly higher than the surface measurements in the Celtra Duo block. While the highest bond strength value HF + US for TS in e.max CAD was 20.07 ± .31, the values of HF + US in Celtra Duo were significantly higher in terms of TL values when compared to other groups. Conclusion. Celtra Duo material demonstrated higher bond strength values after a short and long thermal cycle than e.max CAD material. In general, groups bonded with HF were less affected by the thermal cycle than groups treated with MEP.
- Open Access
- 12 January 2023
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 6 (1) , 116-121
Evaluation of the marginal fit of finish line designs of novel CAD/CAM restoration materials
Aim: The purpose of this study is to compare the marginal fit of crowns manufactured using different CAD/CAM materials on 2 different types of finish line design.Material and Method: Tooth preparations were made by creating 2 different finish lines (rounded shoulder, chamfer) on an acrylic mandibular second premolar model. Impressions were taken on each preparation using polyvinylsiloxane impression material, and blocks with three different compositions including lithium disilicate (LDS), zirconia-reinforced lithium silicate (ZLS), and monolithic zirconia (MZ) (UP.CAD, Celtra Duo, and VITA YZ HT) were produced using a CAD/CAM (computer-aided-design and computer-aided-manufacturing) milling device (VHF R5) (n=10). The marginal gap values of the crown restorations were measured by the same operator using a stereomicroscope (LEICA DVM6). Histogram plots and the Kolmogorov-Smirnov test were used to test the normality of the distributions of the variables. The non-normally distributed (nonparametric) variables were compared using the Mann-Whitney U test for two groups and the Kruskal-Wallis test for more than two groups.Results: The marginal gap values were compared between finish line designs separately for each material. Accordingly, the marginal gap values of the rounded shoulder finish line were smaller than those of the chamfer finish line in all materials. The marginal gap values were also compared among the materials separately for each finish line type. Accordingly, the marginal gap values of the VITA YZ HT (MZ) material were smaller than those of the Celtra Duo (ZLS) and UP.CAD (LDS) materials for both finish line designs. There was no significant difference between Celtra Duo and UP.CAD.Conclusion: The finish line design is a factor that affects marginal fit. Monolithic zirconia is more appropriate for clinical use as it shows a better marginal fit compared to LDS and ZLS.
- 12 January 2023
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 6 (1) , 116-121
Open AccessEvaluation of the marginal fit of finish line designs of novel CAD/CAM restoration materials
Aim: The purpose of this study is to compare the marginal fit of crowns manufactured using different CAD/CAM materials on 2 different types of finish line design.Material and Method: Tooth preparations were made by creating 2 different finish lines (rounded shoulder, chamfer) on an acrylic mandibular second premolar model. Impressions were taken on each preparation using polyvinylsiloxane impression material, and blocks with three different compositions including lithium disilicate (LDS), zirconia-reinforced lithium silicate (ZLS), and monolithic zirconia (MZ) (UP.CAD, Celtra Duo, and VITA YZ HT) were produced using a CAD/CAM (computer-aided-design and computer-aided-manufacturing) milling device (VHF R5) (n=10). The marginal gap values of the crown restorations were measured by the same operator using a stereomicroscope (LEICA DVM6). Histogram plots and the Kolmogorov-Smirnov test were used to test the normality of the distributions of the variables. The non-normally distributed (nonparametric) variables were compared using the Mann-Whitney U test for two groups and the Kruskal-Wallis test for more than two groups.Results: The marginal gap values were compared between finish line designs separately for each material. Accordingly, the marginal gap values of the rounded shoulder finish line were smaller than those of the chamfer finish line in all materials. The marginal gap values were also compared among the materials separately for each finish line type. Accordingly, the marginal gap values of the VITA YZ HT (MZ) material were smaller than those of the Celtra Duo (ZLS) and UP.CAD (LDS) materials for both finish line designs. There was no significant difference between Celtra Duo and UP.CAD.Conclusion: The finish line design is a factor that affects marginal fit. Monolithic zirconia is more appropriate for clinical use as it shows a better marginal fit compared to LDS and ZLS.